Positive DC corona discharge is formed with needle-plate electrode configuration, in which the water vapor is ejected though the needle points. The purpose is to increase the numbers of the water-based radicals, ioniz...Positive DC corona discharge is formed with needle-plate electrode configuration, in which the water vapor is ejected though the needle points. The purpose is to increase the numbers of the water-based radicals, ionize the water molecule and improve the desulfuration efficiency of pulsed corona reactor. The water ions were determined by four stages molecular beam mass spectrometer and diagnose the water-based radicals by emission spectrograph. A conclusion on formation of ions and radicals with DC corona discharges can be drawn.展开更多
In order to improve the anaerobic digestion efficiency of waste activated sludge(WAS),a pretreatment procedure should be carried out so as to disrupt the microbial cell structure,thus releasing intracellular organic...In order to improve the anaerobic digestion efficiency of waste activated sludge(WAS),a pretreatment procedure should be carried out so as to disrupt the microbial cell structure,thus releasing intracellular organic matters.In this paper,a corona discharge triggered by a DC voltage was employed to pre-treat WAS for various time periods under different temperatures.The magnitude of the DC voltage was 4 k V at both negative and positive polarities.The changes in the soluble chemical oxygen demand,phosphorus and nitrogen content,and p H value within the WAS were utilized to estimate the pretreatment performance of the DC corona.It was found that with increasing treatment time,the pretreatment efficiency tends to be reduced.With increased temperature,the pretreatment efficiency appears to be better.It is suggested that the oxidative species and the active particles generated in the corona discharge play an important role in disrupting the microbial cell structure,which is dependent upon the treatment time and the temperature.展开更多
In the development of hybrid HVDC and HVAC transmission lines,the study of radio interference is an important issue.Positive corona current pulses from high voltage transmission lines are the main source of radio inte...In the development of hybrid HVDC and HVAC transmission lines,the study of radio interference is an important issue.Positive corona current pulses from high voltage transmission lines are the main source of radio interference.In this paper,the design of a wire-cylinder gap electrode system is presented to study the influence of AC voltage on the characteristics of positive corona current pulses.The study shows that the mode of the current pulses is different from that of either DC or AC corona discharge.Waveform parameters of the pulses,such as rise time,half wave time,duration time,repetition rates,average amplitude,and time intervals of secondary pulses are all statistically analyzed in this study.The empirical formulas for the repetition rates with different AC voltages are presented.A theoretical explanation based on an ion cloud model is given to reveal the mechanism behind the influence of AC voltage on positive corona discharge.The experimental results could provide some references for the prediction of radio interference from hybrid AC/DC transmission lines.展开更多
The present work is devoted to the 2D simulation of a point-to-plane Atmospheric Corona Discharge Reactor (ACDR) powered by a DC high voltage supply. The corona reactor is periodically crossed by thin mono filamenta...The present work is devoted to the 2D simulation of a point-to-plane Atmospheric Corona Discharge Reactor (ACDR) powered by a DC high voltage supply. The corona reactor is periodically crossed by thin mono filamentary streamers with a natural repetition frequency of some tens of kHz. The study compares the results obtained in dry air and in air mixed with a small amount of water vapour (humid air). The simulation involves the electro-dynamics~ chemical kinetics and neutral gas hydrodynamics phenomena that influence the kinetics of the chemical species transformation. Each discharge lasts about one hundred of a nanosecond while the post- discharge occurring between two successive discharges lasts one hundred of a microsecond. The ACDR is crossed by a lateral dry or humid air flow initially polluted with 400 ppm of NO. After 5 ms, the time corresponding to the occurrence of 50 successive discharge/post-discharge phases, a higher NO removal rate and a lower ozone production rate are found in humid air. This change is due to the presence of the HO2 species formed from the H primary radical in the discharge zone.展开更多
The paper presents a simulation model of the negative corona discharge in N2 under various pressures. The simulated discharge is of a negative point-to-plane mass type, with an inter-electrode separation distance of 2...The paper presents a simulation model of the negative corona discharge in N2 under various pressures. The simulated discharge is of a negative point-to-plane mass type, with an inter-electrode separation distance of 20 mm and a symmetry about the axis of discharge. This simulation investigates the behavior of the neutral density and temperature for different pressures in the range of 0.1-10.0 bar. The spatial and temporal evolution of the neutral gas is analyzed based upon the equations of continuity, momentum and energy in a two-dimensional cylindrical geometry model. For that geometry of the system, the FCT (Flux Corrected Transport) technique was adopted. The results show that the pressure plays a significant role of the neutrals dynamics.展开更多
Research interests have recently been directed towards electrical discharges in multi-phase environments.Natural electrical discharges,such as lightning and coronas,occur in the Earth's atmosphere,which is actually a...Research interests have recently been directed towards electrical discharges in multi-phase environments.Natural electrical discharges,such as lightning and coronas,occur in the Earth's atmosphere,which is actually a mixture of gaseous phase(air) and suspended solid and liquid particulate matters(PMs).An example of an anthropogenic gaseous multi-phase environment is the flow of flue gas through electrostatic precipitators(ESPs),which are generally regarded as a mixture of a post-combustion gas with solid PM and microdroplets suspended in it.Electrical discharges in multi-phase environments,the knowledge of which is scarce,are becoming an attractive research subject,offering a wide variety of possible discharges and multi-phase environments to be studied.This paper is an introduction to electrical discharges in multi-phase environments.It is focused on DC negative coronas and accompanying electrohydrodynamic(EHD) flows in a gaseous two-phase fluid formed by air(a gaseous phase) and solid PM(a solid phase),run under laboratory conditions.The introduction is based on a review of the relevant literature.Two cases will be considered:the first case is of a gaseous two-phase fluid,initially motionless in a closed chamber before being subjected to a negative corona(with the needle-toplate electrode arrangement),which afterwards induces an EHD flow in the chamber,and the second,of a gaseous two-phase fluid flowing transversely with respect to the needle-to-plate electrode axis along a chamber with a corona discharge running between the electrodes.This review-based introductory paper should be of interest to theoretical researchers and modellers in the field of negative corona discharges in single-or two-phase fluids,and for engineers who work on designing EHD devices(such as ESPs,EHD pumps,and smoke detectors).展开更多
该文使用国际大电网会议CIGRE WG D1.14推荐的多针电极系统研究了交直流电晕对高温硫化硅橡胶性能的影响。通过分析试验中的放电功率、电晕前后硅橡胶的憎水性状态、表面电阻率、拉伸强度、拉断伸长率等性能,讨论了交直流电晕、直流正...该文使用国际大电网会议CIGRE WG D1.14推荐的多针电极系统研究了交直流电晕对高温硫化硅橡胶性能的影响。通过分析试验中的放电功率、电晕前后硅橡胶的憎水性状态、表面电阻率、拉伸强度、拉断伸长率等性能,讨论了交直流电晕、直流正负极性电晕对硅橡胶性能影响的异同。结果表明:经过电晕处理,硅橡胶的上述性能均有所下降。就硅橡胶的憎水性状态和表面电阻率而言,交流电晕对硅橡胶的影响程度大于直流电晕的影响程度,直流负极性电晕的影响程度略大于直流正极性电晕的影响程度。硅橡胶的机械强度在电晕处理后有所下降,但交直流电晕处理后的硅橡胶的机械性能差异不明显。电晕场的空间电荷效应以及硅橡胶表面的电荷积累效应是导致不同电压类型的电晕对硅橡胶性能影响不同的原因;使用傅里叶变换红外光谱(Fourier transform infrared spectroscopy,FTIR)和X射线光电子能谱(X-ray photoelectron spectroscopy,XPS)分析方法研究了硅橡胶表面化学结构在电晕前后的变化,认为硅橡胶在电晕处理前后化学结构的变化,是造成硅橡胶性能的变化的直接原因。展开更多
文摘Positive DC corona discharge is formed with needle-plate electrode configuration, in which the water vapor is ejected though the needle points. The purpose is to increase the numbers of the water-based radicals, ionize the water molecule and improve the desulfuration efficiency of pulsed corona reactor. The water ions were determined by four stages molecular beam mass spectrometer and diagnose the water-based radicals by emission spectrograph. A conclusion on formation of ions and radicals with DC corona discharges can be drawn.
基金financially supported by National Natural Science Foundation of China(Grant No.51677127)
文摘In order to improve the anaerobic digestion efficiency of waste activated sludge(WAS),a pretreatment procedure should be carried out so as to disrupt the microbial cell structure,thus releasing intracellular organic matters.In this paper,a corona discharge triggered by a DC voltage was employed to pre-treat WAS for various time periods under different temperatures.The magnitude of the DC voltage was 4 k V at both negative and positive polarities.The changes in the soluble chemical oxygen demand,phosphorus and nitrogen content,and p H value within the WAS were utilized to estimate the pretreatment performance of the DC corona.It was found that with increasing treatment time,the pretreatment efficiency tends to be reduced.With increased temperature,the pretreatment efficiency appears to be better.It is suggested that the oxidative species and the active particles generated in the corona discharge play an important role in disrupting the microbial cell structure,which is dependent upon the treatment time and the temperature.
基金supported by National Basic Research Program of China(973 Program)under Grant 2011CB209402.
文摘In the development of hybrid HVDC and HVAC transmission lines,the study of radio interference is an important issue.Positive corona current pulses from high voltage transmission lines are the main source of radio interference.In this paper,the design of a wire-cylinder gap electrode system is presented to study the influence of AC voltage on the characteristics of positive corona current pulses.The study shows that the mode of the current pulses is different from that of either DC or AC corona discharge.Waveform parameters of the pulses,such as rise time,half wave time,duration time,repetition rates,average amplitude,and time intervals of secondary pulses are all statistically analyzed in this study.The empirical formulas for the repetition rates with different AC voltages are presented.A theoretical explanation based on an ion cloud model is given to reveal the mechanism behind the influence of AC voltage on positive corona discharge.The experimental results could provide some references for the prediction of radio interference from hybrid AC/DC transmission lines.
基金performed using HPC resources from CALMIP(Grant 2011-[P1053])supported by the French Agence Nationale de la Recherche under Project ANR-12-BS09-0019-1 through REMOVAL
文摘The present work is devoted to the 2D simulation of a point-to-plane Atmospheric Corona Discharge Reactor (ACDR) powered by a DC high voltage supply. The corona reactor is periodically crossed by thin mono filamentary streamers with a natural repetition frequency of some tens of kHz. The study compares the results obtained in dry air and in air mixed with a small amount of water vapour (humid air). The simulation involves the electro-dynamics~ chemical kinetics and neutral gas hydrodynamics phenomena that influence the kinetics of the chemical species transformation. Each discharge lasts about one hundred of a nanosecond while the post- discharge occurring between two successive discharges lasts one hundred of a microsecond. The ACDR is crossed by a lateral dry or humid air flow initially polluted with 400 ppm of NO. After 5 ms, the time corresponding to the occurrence of 50 successive discharge/post-discharge phases, a higher NO removal rate and a lower ozone production rate are found in humid air. This change is due to the presence of the HO2 species formed from the H primary radical in the discharge zone.
基金support from DGRSDT,Algerian Ministry of Higher Education and Research(PNR:2011-2013)
文摘The paper presents a simulation model of the negative corona discharge in N2 under various pressures. The simulated discharge is of a negative point-to-plane mass type, with an inter-electrode separation distance of 20 mm and a symmetry about the axis of discharge. This simulation investigates the behavior of the neutral density and temperature for different pressures in the range of 0.1-10.0 bar. The spatial and temporal evolution of the neutral gas is analyzed based upon the equations of continuity, momentum and energy in a two-dimensional cylindrical geometry model. For that geometry of the system, the FCT (Flux Corrected Transport) technique was adopted. The results show that the pressure plays a significant role of the neutrals dynamics.
基金supported by the National Science Centre(Grant No.UMO-2013/09/B/ST8/02054)
文摘Research interests have recently been directed towards electrical discharges in multi-phase environments.Natural electrical discharges,such as lightning and coronas,occur in the Earth's atmosphere,which is actually a mixture of gaseous phase(air) and suspended solid and liquid particulate matters(PMs).An example of an anthropogenic gaseous multi-phase environment is the flow of flue gas through electrostatic precipitators(ESPs),which are generally regarded as a mixture of a post-combustion gas with solid PM and microdroplets suspended in it.Electrical discharges in multi-phase environments,the knowledge of which is scarce,are becoming an attractive research subject,offering a wide variety of possible discharges and multi-phase environments to be studied.This paper is an introduction to electrical discharges in multi-phase environments.It is focused on DC negative coronas and accompanying electrohydrodynamic(EHD) flows in a gaseous two-phase fluid formed by air(a gaseous phase) and solid PM(a solid phase),run under laboratory conditions.The introduction is based on a review of the relevant literature.Two cases will be considered:the first case is of a gaseous two-phase fluid,initially motionless in a closed chamber before being subjected to a negative corona(with the needle-toplate electrode arrangement),which afterwards induces an EHD flow in the chamber,and the second,of a gaseous two-phase fluid flowing transversely with respect to the needle-to-plate electrode axis along a chamber with a corona discharge running between the electrodes.This review-based introductory paper should be of interest to theoretical researchers and modellers in the field of negative corona discharges in single-or two-phase fluids,and for engineers who work on designing EHD devices(such as ESPs,EHD pumps,and smoke detectors).