Global energy and environmental issues are becoming increasingly problematic,and the vibration and noise problem of 110 kV transformers,which are the most widely distributed,have attracted widespread attention from bo...Global energy and environmental issues are becoming increasingly problematic,and the vibration and noise problem of 110 kV transformers,which are the most widely distributed,have attracted widespread attention from both inside and outside the industry.DC bias is one of the main contributing factors to vibration noise during the normal operation of transformers.To clarify the vibration and noise mechanism of a 110 kV transformer under a DC bias,a multi-field coupling model of a 110 kV transformer was established using the finite element method.The electromagnetic,vibration,and noise characteristics during the DC bias process were compared and quantified through field circuit coupling in parallel with the power frequency of AC,harmonic,and DC power sources.It was found that a DC bias can cause significant distortions in the magnetic flux density,force,and displacement distributions of the core and winding.The contributions of the DC bias effect to the core and winding are different at Kdc=0.85.At this point,the core approached saturation,and the increase in the core force and displacement slowed.However,the saturation of the core increased the leakage flux,and the stress and displacement of the winding increased faster.The sound field distribution characteristics of the 110 kV transformer under a DC bias are related to the force characteristics.When the DC bias coefficient was 1.25,the noise sound pressure level reached 73.6 dB.展开更多
由于DCS控制器中电表传感器在计量检测过程中,传统的B-MAC-DCS协议能耗和丢包率较高,无法缓解汇聚节点的漏斗效应,导致在远程抄表过程中传感器计量误差增大。提出一种机械电表接触传感器计量误差检测方法。采用小波基函数对DCS控制器中...由于DCS控制器中电表传感器在计量检测过程中,传统的B-MAC-DCS协议能耗和丢包率较高,无法缓解汇聚节点的漏斗效应,导致在远程抄表过程中传感器计量误差增大。提出一种机械电表接触传感器计量误差检测方法。采用小波基函数对DCS控制器中的接触传感器计量数据抗干扰处理,并通过动态选取阈值的方法,对经过小波变换后的数据去除噪声。使用低功耗自适应集簇分层型(low energy adaptive clustering hierarchy,LEACH)协议分簇代替传统的B-MAC协议;根据簇内监测值,引入阈值分析方法获取传感器计量指标,并将其作为判定依据进行误差检测,根据计量指标的变化情况判断是否存在计量误差。实验结果表明,所提方法可以准确且有效检测出机械电表接触传感器计量误差,解决DCS中机械电表的运行隐患问题。展开更多
基于移相加占空比控制策略的三有源桥TAB(triple active bridge)DC-DC变换器具有效率高和软开关范围可扩展等优点,但其小信号建模过程复杂、闭环控制环路参数整定困难。针对该问题,提出1种TAB工作在移相加占空比控制下的全阶连续广义状...基于移相加占空比控制策略的三有源桥TAB(triple active bridge)DC-DC变换器具有效率高和软开关范围可扩展等优点,但其小信号建模过程复杂、闭环控制环路参数整定困难。针对该问题,提出1种TAB工作在移相加占空比控制下的全阶连续广义状态平均建模和PI控制器设计方法。首先,分析TAB的运行原理和Y型等效结构;然后,结合移相加占空比控制的特点和交流方波源等效方法,推导出TAB的广义状态空间平均模型;接着,在推得模型的基础上求得输入到输出的传递函数,设计出PI控制器参数。最后,结合数字仿真及样机实验验证了所提方法的正确性及有效性。展开更多
基金supported by the Key R&D Program of Shandong Province(2021CXGC010210).
文摘Global energy and environmental issues are becoming increasingly problematic,and the vibration and noise problem of 110 kV transformers,which are the most widely distributed,have attracted widespread attention from both inside and outside the industry.DC bias is one of the main contributing factors to vibration noise during the normal operation of transformers.To clarify the vibration and noise mechanism of a 110 kV transformer under a DC bias,a multi-field coupling model of a 110 kV transformer was established using the finite element method.The electromagnetic,vibration,and noise characteristics during the DC bias process were compared and quantified through field circuit coupling in parallel with the power frequency of AC,harmonic,and DC power sources.It was found that a DC bias can cause significant distortions in the magnetic flux density,force,and displacement distributions of the core and winding.The contributions of the DC bias effect to the core and winding are different at Kdc=0.85.At this point,the core approached saturation,and the increase in the core force and displacement slowed.However,the saturation of the core increased the leakage flux,and the stress and displacement of the winding increased faster.The sound field distribution characteristics of the 110 kV transformer under a DC bias are related to the force characteristics.When the DC bias coefficient was 1.25,the noise sound pressure level reached 73.6 dB.
文摘由于DCS控制器中电表传感器在计量检测过程中,传统的B-MAC-DCS协议能耗和丢包率较高,无法缓解汇聚节点的漏斗效应,导致在远程抄表过程中传感器计量误差增大。提出一种机械电表接触传感器计量误差检测方法。采用小波基函数对DCS控制器中的接触传感器计量数据抗干扰处理,并通过动态选取阈值的方法,对经过小波变换后的数据去除噪声。使用低功耗自适应集簇分层型(low energy adaptive clustering hierarchy,LEACH)协议分簇代替传统的B-MAC协议;根据簇内监测值,引入阈值分析方法获取传感器计量指标,并将其作为判定依据进行误差检测,根据计量指标的变化情况判断是否存在计量误差。实验结果表明,所提方法可以准确且有效检测出机械电表接触传感器计量误差,解决DCS中机械电表的运行隐患问题。
文摘基于移相加占空比控制策略的三有源桥TAB(triple active bridge)DC-DC变换器具有效率高和软开关范围可扩展等优点,但其小信号建模过程复杂、闭环控制环路参数整定困难。针对该问题,提出1种TAB工作在移相加占空比控制下的全阶连续广义状态平均建模和PI控制器设计方法。首先,分析TAB的运行原理和Y型等效结构;然后,结合移相加占空比控制的特点和交流方波源等效方法,推导出TAB的广义状态空间平均模型;接着,在推得模型的基础上求得输入到输出的传递函数,设计出PI控制器参数。最后,结合数字仿真及样机实验验证了所提方法的正确性及有效性。