Frequency droop control is widely used in permanent magnet synchronous generators(PMSGs)based wind turbines(WTs)for grid frequency support.However,under frequency deviations,significant DC-link voltage fluctuations ma...Frequency droop control is widely used in permanent magnet synchronous generators(PMSGs)based wind turbines(WTs)for grid frequency support.However,under frequency deviations,significant DC-link voltage fluctuations may occur during the transient process due to sudden changes in real power of such WTs.To address this issue,a current feedforward control strategy is proposed for PMSG-based WTs to reduce DC-link voltage fluctuations when the WTs are providing frequency support under grid frequency deviations.Meanwhile,the desired frequency support capability of the PMSG-based WTs can be ensured.Simulation results verify the rationality of the analysis and the effectiveness of the proposed control method.展开更多
An equivalent source-load MTDC system including DC voltage control units,power control units and interconnected DC lines is considered in this paper,which can be regarded as a generic structure of low-voltage DC micro...An equivalent source-load MTDC system including DC voltage control units,power control units and interconnected DC lines is considered in this paper,which can be regarded as a generic structure of low-voltage DC microgrids,mediumvoltage DC distribution systems or HVDC transmission systems with a common DC bus.A reduced-order model is proposed with a circuit structure of a resistor,inductor and capacitor in parallel for dynamic stability analysis of the system in DC voltage control timescale.The relationship between control parameters and physical parameters of the equivalent circuit can be found,which provides an intuitive insight into the physical meaning of control parameters.Employing this model,a second-order characteristic equation is further derived to investigate system dynamic stability mechanisms in an analytical approach.As a result,the system oscillation frequency and damping are characterized in a straight forward manner,and the role of electrical and control parameters and different system-level control strategies in system dynamic stability in DC voltage control timescale is defined.The effectiveness of the proposed reduced-order model and the correctness of the theoretical analysis are verified by simulation based on PSCAD/EMTDC and an experiment based on a hardware low-voltage MTDC system platform.展开更多
Stability of grid-connected VSCs in DC voltage control(DVC)timescales(i.e.,the frequency range of dynamics covering converter outer controls)has recently caught increased attention,while the existing approaches,such a...Stability of grid-connected VSCs in DC voltage control(DVC)timescales(i.e.,the frequency range of dynamics covering converter outer controls)has recently caught increased attention,while the existing approaches,such as eigenvalue analysis and dq-domain impedance analysis,have respective limitations on addressing these types of stability issues.This paper proposes an alternative net damping criterion dedicated for analyzing the DVC timescale stability in a multi-VSC system.This criterion is strictly mapped from the Nyquist stability criterion utilizing the gain margin concept,which preserves the advantages of the classical positive net damping criterion suggested by Canay[20]–allowing for decomposition analysis of a subsystem’s contribution to the closed-loop stability in a single-input single-output(SISO)framework,but overcomes its deficiency of possibly erroneous prediction of system dynamic behaviors.Case studies show that the proposed criterion can correctly predict some unstable conditions(e.g.,monotonic divergence)which cannot be identified by the classical net damping criterion.Additionally,the condition for when the classical criterion is available is also pointed out,the proposed criterion can also act as a complement of the classical criterion for stability examination.展开更多
This paper proposes an indirect power control of doubly fed induction generator (DFIG) with the rotor connected to the electric grid through a back-to-back pulse width modulation (PWM) converter for variable speed...This paper proposes an indirect power control of doubly fed induction generator (DFIG) with the rotor connected to the electric grid through a back-to-back pulse width modulation (PWM) converter for variable speed wind power generation. Appropriate state space model of the DFIG is deduced. An original control strategy based on a variable structure control theory, also called sliding mode control, is applied to achieve the control of the active and reactive power exchanged between the stator of the DFIG and the grid. A proportional-integral-(P1) controller is used to keep the DC-link voltage constant for a back-to-back PWM converter. Simulations are conducted for validation of the digital controller operation using Matlab/Simulink software.展开更多
With most countries paying attention to the environment protection, hybrid electric vehicles have become a focus of automobile research and development due to the characteristics of energy saving and low emission. Pow...With most countries paying attention to the environment protection, hybrid electric vehicles have become a focus of automobile research and development due to the characteristics of energy saving and low emission. Power follower control strategy(PFCS) and DC-link voltage control strategy are two sorts of control strategies for series hybrid electric vehicles(HEVs). Combining those two control strategies is a new idea for control strategy of series hybrid electric vehicles. By tuning essential parameters which are the defined constants under DClink voltage control and under PFCS, the points of minimum mass of equivalent fuel consumption(EFC) corresponding to a series of variables are marked for worldwide harmonized light vehicles test procedure(WLTP). The fuel economy of series HEVs with the combination control schemes performs better compared with individual control scheme. The results show the effects of the combination control schemes for series HEVs driving in an urban environment.展开更多
The prominence of Renewable Energy Sources(RES)in the process of power generation is exponentially increased in the recent days since these sources assist in minimizing the environmental contamination.A grid-tied DFIG...The prominence of Renewable Energy Sources(RES)in the process of power generation is exponentially increased in the recent days since these sources assist in minimizing the environmental contamination.A grid-tied DFIG(Doubly Fed Induction Generator)based WECS(Wind Energy Conversion System)is introduced in this work,in which a Landsman converter is implemented to impro-vise the output voltage of PV without anyfluctuations.A novel GA(Genetic Algorithm)assisted ANN(Artificial Neural Network)is employed for tracking the Maximum power from PV.Among the rotor and grid side controllers,the for-mer is implemented by combining the statorflux with d-q reference frame and the latter is realized by the PI controller.The proposed approach delivers better per-formance in the compensation of real and reactive power along with the DC link voltage control.The controlling mechanism is verified in both MATLAB and experimental bench setupby using an emulated wind turbine for the concurrent control of DC link potential,active and reactive powers.The source current THD is observed as 1.93%and 2.4%for simulation and hardware implementation respectively.展开更多
随着配电网中光伏(photovoltaic,PV)发电渗透率增大,由于源/荷分布不均衡引起的馈线功率急剧波动、电压越限问题时有发生。提出一种考虑储能-智能软开关(soft open point,SOP)、光伏逆变器及无功电压控制(var/voltage control,VVC)设备...随着配电网中光伏(photovoltaic,PV)发电渗透率增大,由于源/荷分布不均衡引起的馈线功率急剧波动、电压越限问题时有发生。提出一种考虑储能-智能软开关(soft open point,SOP)、光伏逆变器及无功电压控制(var/voltage control,VVC)设备的主动配电网混合时间尺度鲁棒优化方法,以提高配网运行的经济性和稳定性。首先,通过在配电网线路末端间引入储能元件与SOP相结合(E-SOP)的柔性互联装置,建立计及多种调压设备的配电网日前-日内鲁棒优化模型;其次,建立基于鲁棒条件下的时序电压灵敏度逆变器下垂控制模型,以应对PV发电随机性强所带来的风险,达到维持系统电压稳定性、平衡配电网源/荷分布的目的;最后,以改进的IEEE 33节点系统为例进行仿真算例分析,验证了所提方法的有效性。展开更多
基金This work is jointly supported by the National Key R&D Programme of China(No.2017YFB0902000)the National Natural Science Foundation of China(No.U1766206)the Science and Technology Programme of the State Grid Corporation(No.52110418000P).
文摘Frequency droop control is widely used in permanent magnet synchronous generators(PMSGs)based wind turbines(WTs)for grid frequency support.However,under frequency deviations,significant DC-link voltage fluctuations may occur during the transient process due to sudden changes in real power of such WTs.To address this issue,a current feedforward control strategy is proposed for PMSG-based WTs to reduce DC-link voltage fluctuations when the WTs are providing frequency support under grid frequency deviations.Meanwhile,the desired frequency support capability of the PMSG-based WTs can be ensured.Simulation results verify the rationality of the analysis and the effectiveness of the proposed control method.
基金This work was supported in part by the National Natural Science Foundation of China under Grant No.51977142.
文摘An equivalent source-load MTDC system including DC voltage control units,power control units and interconnected DC lines is considered in this paper,which can be regarded as a generic structure of low-voltage DC microgrids,mediumvoltage DC distribution systems or HVDC transmission systems with a common DC bus.A reduced-order model is proposed with a circuit structure of a resistor,inductor and capacitor in parallel for dynamic stability analysis of the system in DC voltage control timescale.The relationship between control parameters and physical parameters of the equivalent circuit can be found,which provides an intuitive insight into the physical meaning of control parameters.Employing this model,a second-order characteristic equation is further derived to investigate system dynamic stability mechanisms in an analytical approach.As a result,the system oscillation frequency and damping are characterized in a straight forward manner,and the role of electrical and control parameters and different system-level control strategies in system dynamic stability in DC voltage control timescale is defined.The effectiveness of the proposed reduced-order model and the correctness of the theoretical analysis are verified by simulation based on PSCAD/EMTDC and an experiment based on a hardware low-voltage MTDC system platform.
基金This work was supported in part by the Research Grants Council of Hong Kong under Grant GRF 17207818the National Natural Science Foundation of China under Grant 51677160the Themebased Research Scheme(TRS)under T23-701/14-N.
文摘Stability of grid-connected VSCs in DC voltage control(DVC)timescales(i.e.,the frequency range of dynamics covering converter outer controls)has recently caught increased attention,while the existing approaches,such as eigenvalue analysis and dq-domain impedance analysis,have respective limitations on addressing these types of stability issues.This paper proposes an alternative net damping criterion dedicated for analyzing the DVC timescale stability in a multi-VSC system.This criterion is strictly mapped from the Nyquist stability criterion utilizing the gain margin concept,which preserves the advantages of the classical positive net damping criterion suggested by Canay[20]–allowing for decomposition analysis of a subsystem’s contribution to the closed-loop stability in a single-input single-output(SISO)framework,but overcomes its deficiency of possibly erroneous prediction of system dynamic behaviors.Case studies show that the proposed criterion can correctly predict some unstable conditions(e.g.,monotonic divergence)which cannot be identified by the classical net damping criterion.Additionally,the condition for when the classical criterion is available is also pointed out,the proposed criterion can also act as a complement of the classical criterion for stability examination.
文摘This paper proposes an indirect power control of doubly fed induction generator (DFIG) with the rotor connected to the electric grid through a back-to-back pulse width modulation (PWM) converter for variable speed wind power generation. Appropriate state space model of the DFIG is deduced. An original control strategy based on a variable structure control theory, also called sliding mode control, is applied to achieve the control of the active and reactive power exchanged between the stator of the DFIG and the grid. A proportional-integral-(P1) controller is used to keep the DC-link voltage constant for a back-to-back PWM converter. Simulations are conducted for validation of the digital controller operation using Matlab/Simulink software.
基金supported in part by the National Natural Science Foundation of China(61773382,61773381,61533019)Chinese Guangdongs S&T projects(2016B090910001,2017B090912001)+1 种基金2016 S&T Benefiting Special Project(16-6-2-62-nsh)of Qingdao Achievements Transformation ProgramDongguan Innovation Talents Project(Gang Xiong)
文摘With most countries paying attention to the environment protection, hybrid electric vehicles have become a focus of automobile research and development due to the characteristics of energy saving and low emission. Power follower control strategy(PFCS) and DC-link voltage control strategy are two sorts of control strategies for series hybrid electric vehicles(HEVs). Combining those two control strategies is a new idea for control strategy of series hybrid electric vehicles. By tuning essential parameters which are the defined constants under DClink voltage control and under PFCS, the points of minimum mass of equivalent fuel consumption(EFC) corresponding to a series of variables are marked for worldwide harmonized light vehicles test procedure(WLTP). The fuel economy of series HEVs with the combination control schemes performs better compared with individual control scheme. The results show the effects of the combination control schemes for series HEVs driving in an urban environment.
文摘The prominence of Renewable Energy Sources(RES)in the process of power generation is exponentially increased in the recent days since these sources assist in minimizing the environmental contamination.A grid-tied DFIG(Doubly Fed Induction Generator)based WECS(Wind Energy Conversion System)is introduced in this work,in which a Landsman converter is implemented to impro-vise the output voltage of PV without anyfluctuations.A novel GA(Genetic Algorithm)assisted ANN(Artificial Neural Network)is employed for tracking the Maximum power from PV.Among the rotor and grid side controllers,the for-mer is implemented by combining the statorflux with d-q reference frame and the latter is realized by the PI controller.The proposed approach delivers better per-formance in the compensation of real and reactive power along with the DC link voltage control.The controlling mechanism is verified in both MATLAB and experimental bench setupby using an emulated wind turbine for the concurrent control of DC link potential,active and reactive powers.The source current THD is observed as 1.93%and 2.4%for simulation and hardware implementation respectively.
文摘随着配电网中光伏(photovoltaic,PV)发电渗透率增大,由于源/荷分布不均衡引起的馈线功率急剧波动、电压越限问题时有发生。提出一种考虑储能-智能软开关(soft open point,SOP)、光伏逆变器及无功电压控制(var/voltage control,VVC)设备的主动配电网混合时间尺度鲁棒优化方法,以提高配网运行的经济性和稳定性。首先,通过在配电网线路末端间引入储能元件与SOP相结合(E-SOP)的柔性互联装置,建立计及多种调压设备的配电网日前-日内鲁棒优化模型;其次,建立基于鲁棒条件下的时序电压灵敏度逆变器下垂控制模型,以应对PV发电随机性强所带来的风险,达到维持系统电压稳定性、平衡配电网源/荷分布的目的;最后,以改进的IEEE 33节点系统为例进行仿真算例分析,验证了所提方法的有效性。