期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
High Frequency Resonance in DFIG-Based Wind Farm with Variable Power Capacity 被引量:1
1
作者 Yipeng Song Heng Nian Frede Blaabjerg 《Chinese Journal of Electrical Engineering》 CSCD 2017年第3期52-58,共7页
As wind power penetration has been gaining in the power grid for decades,a large number of the doubly fed induction generator(DFIG)based wind farms are being established around the globe.The power capacities of these ... As wind power penetration has been gaining in the power grid for decades,a large number of the doubly fed induction generator(DFIG)based wind farms are being established around the globe.The power capacities of these wind farms may vary around hundreds of MW,and most of the wind farms are connected to long transmission cables whose impedances can not be ignored and require careful attention.Several works have investigated the impedance interaction between the DFIG based wind farm and long transmission cables which may unfortunately cause high frequency resonance(HFR).The main contribution of this paper is to investigate the influence of the variable wind farm capacity on the behavior of the HFR when certain transmission cables are provided.It is found out that the potential HFR may happen in certain wind farms,and the larger wind farm capacity causes more severe HFR due to the relatively weaker grid transmission capability.Simulation results based on Matlab/Simulink are given to validate the analysis of HFR. 展开更多
关键词 dfig based wind farm variable power capacity long transmission cable high frequency resonance
原文传递
Multiple Random Forests Based Intelligent Location of Single-phase Grounding Fault in Power Lines of DFIG-based Wind Farm 被引量:2
2
作者 Yongli Zhu Hua Peng 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第5期1152-1163,共12页
To address the problems of wind power abandonment and the stoppage of electricity transmission caused by a short circuit in a power line of a doubly-fed induction generator(DFIG) based wind farm, this paper proposes a... To address the problems of wind power abandonment and the stoppage of electricity transmission caused by a short circuit in a power line of a doubly-fed induction generator(DFIG) based wind farm, this paper proposes an intelligent location method for a single-phase grounding fault based on a multiple random forests(multi-RF) algorithm. First, the simulation model is built, and the fundamental amplitudes of the zerosequence currents are extracted by a fast Fourier transform(FFT) to construct the feature set. Then, the random forest classification algorithm is applied to establish the fault section locator. The model is resampled on the basis of the bootstrap method to generate multiple sample subsets, which are used to establish multiple classification and regression tree(CART) classifiers. The CART classifiers use the mean decrease in the node impurity as the feature importance,which is used to mine the relationship between features and fault sections. Subsequently, a fault section is identified by voting on the test results for each classifier. Finally, a multi-RF regression fault locator is built to output the predicted fault distance. Experimental results with PSCAD/EMTDC software show that the proposed method can overcome the shortcomings of a single RF and has the advantage of locating a short hybrid overhead/cable line with multiple branches. Compared with support vector machines(SVMs)and previously reported methods, the proposed method can meet the location accuracy and efficiency requirements of a DFIG-based wind farm better. 展开更多
关键词 Doubly-fed induction generator(dfig)based wind farm power line multiple random forests(multi-RF) single-phase grounding fault fault location
原文传递
上一页 1 下一页 到第