The application areas of conventional push pull converters are limited because of high voltage stress of switches (twice of input voltage). This paper presents a novel zero voltage and zero current switching (ZCS)...The application areas of conventional push pull converters are limited because of high voltage stress of switches (twice of input voltage). This paper presents a novel zero voltage and zero current switching (ZCS) PWM push pull three level converter in which the voltage stress of switches is input voltage. With phase shifted modulation strategy, the leading switches can only realize zero voltage switching (ZVS), and the lagging switches can realize ZCS when block capacitor and block diodes are added. Using the strategy, the converter overcomes the drawbacks presented by the conventional push pull converter, such as magnetic aberration, large switch loss, and voltage spike on switches, so it can get higher efficiency, and a wider application area. The operating principle of the new converter is analyzed and verified on a 600 W, 50 kHz experimental prototype. Several zero voltage and zero current switching PWM push pull three level converters are proposed.展开更多
Multilevel inverter has played a vital role in medium and high power applications in the recent years. In this paper, Reduced Switch Count Multi Level Inverter structure (RSCMLI) topology is presented with different p...Multilevel inverter has played a vital role in medium and high power applications in the recent years. In this paper, Reduced Switch Count Multi Level Inverter structure (RSCMLI) topology is presented with different pulse width modulation techniques. The harmonic level analysis is carried out for the reduced switch count multilevel inverter with the different PWM technique such as with Alternate Phase Opposition Disposition (APOD) method, In Phase Disposition (IPD) method and multi reference pulse width modulation method for five level, seven level , nine level and eleven level inverter. The simulation results are compared with the cascaded H Bridge Multi Level Inverter (CHBMLI). The nine level RSCMLI inverter with APOD method is used for the Distribution Static Synchronous Compensator (DSTATCOM) application in the nonlinear load connected system for power factor improvement. The result shows that the harmonic level and the number of switches required for RSCMLI is reduced compared to CHBMLI. RSCMLI employed in DSTATCOM improves the power factor and harmonic level of the system when it is connected to the nonlinear load.展开更多
The paper proposes a new method of equal switching distribution that can be applied to cascaded multi-level inverters. This method is based on the fact that in the cascaded multilevel inverters, the output phase volta...The paper proposes a new method of equal switching distribution that can be applied to cascaded multi-level inverters. This method is based on the fact that in the cascaded multilevel inverters, the output phase voltage is the sum of voltage waveforms produced by all cascaded cells. By periodically exchanging cells’ voltage waveforms, the proposed method ensures equal average switchings distribution between all cascaded cells. This method is applied to the 13-level inverter, which consists of three cascaded 5-level H-bridge cells per phase. However, the proposed method can be extended to any desired number of voltage levels and applied to any type of cascaded multi-level inverter. Extensive simulation results of the tested 13-level inverter with the equal switching distribution are presented. Moreover, the proposed method is compared to the standard control approaches and its advantages are shown.展开更多
In recent years,the use of first language(L1)in teaching of second and foreign languages(L2/FL)has been a highly con⁃troversial issue in language teaching and learning studies.This qualitative case study of four Ameri...In recent years,the use of first language(L1)in teaching of second and foreign languages(L2/FL)has been a highly con⁃troversial issue in language teaching and learning studies.This qualitative case study of four American instructors use of codeswitching in their FL teaching explores in what occasion,in what ways,and for what reasons the instructors switched between stu⁃dents’native language and target languages.The results indicate that instructors’choices are to a great extent influenced by vari⁃ous factors,including their personal preferences,class subjects,and communicative purposes.Discussions about new discoveries have also been conducted.展开更多
The peculiar photoconduction in semi insulating GaAs photoconductive switch being triggered by 1064nm laser pulse is reported.The gap between two electrodes of the switch is 4mm.When it is triggered by laser pulse wi...The peculiar photoconduction in semi insulating GaAs photoconductive switch being triggered by 1064nm laser pulse is reported.The gap between two electrodes of the switch is 4mm.When it is triggered by laser pulse with energy of 0 8mJ and the pulse width of 5ns,and operated at biased electric field of 2 0 and 6 0kV/cm,both linear and nonlinear modes of the switch are observed respectively.Whereas the biased electric field adds to 9 5kV/cm,and the triggered laser is in range of 0 5~1 0mJ,the peculiar performed characteristic is observed:the switch gives a linear waveform firstly,and then after a delay time of about 20~250ns,it outputs a nonlinear waveform again.The physical mechanism of this specific phenomenon is associated with the anti site defects of semi insulating GaAs and two step single photon absorption.The delay time between linear waveform and nonlinear waveform is calculated,and the result matches the experiments.展开更多
Gallium arsenide (GaAs) photoconductive semiconductor switches (PCSS's) with a 1.55mm gap spacing trigged by 1553nm femtosecond fiber laser pulse is presented.The switches are biased with 3.33~10.3kV/cm and irrad...Gallium arsenide (GaAs) photoconductive semiconductor switches (PCSS's) with a 1.55mm gap spacing trigged by 1553nm femtosecond fiber laser pulse is presented.The switches are biased with 3.33~10.3kV/cm and irradiated by femtosecond fiber laser operated at a wavelength of 1553nm with pulse width of 200fs and pulse energy of 0.2nJ.The experiments show that,even if the semi-insulating GaAs photoconductive switch operates under the electrical field of 10.3kV/cm,it will be still linear response,and a clear corresponding output electric pulse with the peak voltage of 0.8mV is captured.From the weak photoconductivity on laser intensity,photoabsorption mediated by EL2 deep level defects is suggested,as the primary process for the photoconductivity.展开更多
Due to the large number of submodules(SMs),and modular multilevel converters(MMCs)in high-voltage applications,they are usually regulated by the nearest level modulation(NLM).Moreover,the large number of SMs causes a ...Due to the large number of submodules(SMs),and modular multilevel converters(MMCs)in high-voltage applications,they are usually regulated by the nearest level modulation(NLM).Moreover,the large number of SMs causes a challenge for the fault diagnosis strategy(FDS).This paper proposes a currentless FDS for MMC with NLM.In FDS,the voltage sensor is relocated to measure the output voltage of the SM.To acquire the capacitor voltage and avoid increasing extra sensors,a capacitor voltage calculation method is proposed.Based on the measurement of output voltages,the faults can be detected and the number of different-type switch open-circuit faults can be confirmed from the numerous SMs in an arm,which narrows the scope of fault localization.Then,the faulty SMs and faulty switches in these SMs are further located without arm current according to the sorting of capacitor voltages in the voltage balancing algorithm.The FDS is independent of the arm current,which can reduce the communication cost in the hierarchical control system of MMC.Furthermore,the proposed FDS not only simplifies the identification of switch open-circuit faults by confirming the scope of faults,but also detects and locates multiple different-type faults in an arm.The effectiveness of the proposed strategy is verified by the simulation results.展开更多
文摘The application areas of conventional push pull converters are limited because of high voltage stress of switches (twice of input voltage). This paper presents a novel zero voltage and zero current switching (ZCS) PWM push pull three level converter in which the voltage stress of switches is input voltage. With phase shifted modulation strategy, the leading switches can only realize zero voltage switching (ZVS), and the lagging switches can realize ZCS when block capacitor and block diodes are added. Using the strategy, the converter overcomes the drawbacks presented by the conventional push pull converter, such as magnetic aberration, large switch loss, and voltage spike on switches, so it can get higher efficiency, and a wider application area. The operating principle of the new converter is analyzed and verified on a 600 W, 50 kHz experimental prototype. Several zero voltage and zero current switching PWM push pull three level converters are proposed.
文摘Multilevel inverter has played a vital role in medium and high power applications in the recent years. In this paper, Reduced Switch Count Multi Level Inverter structure (RSCMLI) topology is presented with different pulse width modulation techniques. The harmonic level analysis is carried out for the reduced switch count multilevel inverter with the different PWM technique such as with Alternate Phase Opposition Disposition (APOD) method, In Phase Disposition (IPD) method and multi reference pulse width modulation method for five level, seven level , nine level and eleven level inverter. The simulation results are compared with the cascaded H Bridge Multi Level Inverter (CHBMLI). The nine level RSCMLI inverter with APOD method is used for the Distribution Static Synchronous Compensator (DSTATCOM) application in the nonlinear load connected system for power factor improvement. The result shows that the harmonic level and the number of switches required for RSCMLI is reduced compared to CHBMLI. RSCMLI employed in DSTATCOM improves the power factor and harmonic level of the system when it is connected to the nonlinear load.
文摘The paper proposes a new method of equal switching distribution that can be applied to cascaded multi-level inverters. This method is based on the fact that in the cascaded multilevel inverters, the output phase voltage is the sum of voltage waveforms produced by all cascaded cells. By periodically exchanging cells’ voltage waveforms, the proposed method ensures equal average switchings distribution between all cascaded cells. This method is applied to the 13-level inverter, which consists of three cascaded 5-level H-bridge cells per phase. However, the proposed method can be extended to any desired number of voltage levels and applied to any type of cascaded multi-level inverter. Extensive simulation results of the tested 13-level inverter with the equal switching distribution are presented. Moreover, the proposed method is compared to the standard control approaches and its advantages are shown.
文摘In recent years,the use of first language(L1)in teaching of second and foreign languages(L2/FL)has been a highly con⁃troversial issue in language teaching and learning studies.This qualitative case study of four American instructors use of codeswitching in their FL teaching explores in what occasion,in what ways,and for what reasons the instructors switched between stu⁃dents’native language and target languages.The results indicate that instructors’choices are to a great extent influenced by vari⁃ous factors,including their personal preferences,class subjects,and communicative purposes.Discussions about new discoveries have also been conducted.
文摘The peculiar photoconduction in semi insulating GaAs photoconductive switch being triggered by 1064nm laser pulse is reported.The gap between two electrodes of the switch is 4mm.When it is triggered by laser pulse with energy of 0 8mJ and the pulse width of 5ns,and operated at biased electric field of 2 0 and 6 0kV/cm,both linear and nonlinear modes of the switch are observed respectively.Whereas the biased electric field adds to 9 5kV/cm,and the triggered laser is in range of 0 5~1 0mJ,the peculiar performed characteristic is observed:the switch gives a linear waveform firstly,and then after a delay time of about 20~250ns,it outputs a nonlinear waveform again.The physical mechanism of this specific phenomenon is associated with the anti site defects of semi insulating GaAs and two step single photon absorption.The delay time between linear waveform and nonlinear waveform is calculated,and the result matches the experiments.
文摘Gallium arsenide (GaAs) photoconductive semiconductor switches (PCSS's) with a 1.55mm gap spacing trigged by 1553nm femtosecond fiber laser pulse is presented.The switches are biased with 3.33~10.3kV/cm and irradiated by femtosecond fiber laser operated at a wavelength of 1553nm with pulse width of 200fs and pulse energy of 0.2nJ.The experiments show that,even if the semi-insulating GaAs photoconductive switch operates under the electrical field of 10.3kV/cm,it will be still linear response,and a clear corresponding output electric pulse with the peak voltage of 0.8mV is captured.From the weak photoconductivity on laser intensity,photoabsorption mediated by EL2 deep level defects is suggested,as the primary process for the photoconductivity.
基金supported by the State Key Laboratory of Advanced Power Transmission Technology(GEIRI-SKL-2020-011)。
文摘Due to the large number of submodules(SMs),and modular multilevel converters(MMCs)in high-voltage applications,they are usually regulated by the nearest level modulation(NLM).Moreover,the large number of SMs causes a challenge for the fault diagnosis strategy(FDS).This paper proposes a currentless FDS for MMC with NLM.In FDS,the voltage sensor is relocated to measure the output voltage of the SM.To acquire the capacitor voltage and avoid increasing extra sensors,a capacitor voltage calculation method is proposed.Based on the measurement of output voltages,the faults can be detected and the number of different-type switch open-circuit faults can be confirmed from the numerous SMs in an arm,which narrows the scope of fault localization.Then,the faulty SMs and faulty switches in these SMs are further located without arm current according to the sorting of capacitor voltages in the voltage balancing algorithm.The FDS is independent of the arm current,which can reduce the communication cost in the hierarchical control system of MMC.Furthermore,the proposed FDS not only simplifies the identification of switch open-circuit faults by confirming the scope of faults,but also detects and locates multiple different-type faults in an arm.The effectiveness of the proposed strategy is verified by the simulation results.