Parasympathetic function can be assessed by the deep breathing test (DB) as a simple and reproducible cardiovascular reflex. The aim of this study is to use this test to compare the vagal response of a young footballe...Parasympathetic function can be assessed by the deep breathing test (DB) as a simple and reproducible cardiovascular reflex. The aim of this study is to use this test to compare the vagal response of a young footballers group to of age-matched untrained normal subjects. Deep breathing test was performed in 2 groups: one of 20 adult young footballers (average age of 19.3 ± 0.6 years), and a second age-matched group of 20 untrained subjects (average age of 19.6 ± 0.6 years). Subjects underwent the DB test after 30 min resting in supine position, and responses were expressed as a percentage of variation of heart rate during the stimulation. Student’s t-test was used to evaluate statistical differences among the two groups for all parameters (vagal response, heart rate, VO2max….) and considering p < 0.05 as a significant difference. The results showed that vagal response to deep breathing test was significantly higher in the young footballers when compared to the untrained controls (72.6% ± 16.2% vs 55.0% ± 12.8%, respectively, p = 0.03). The basal heart rate was significantly lower in footballers than in the controls group (52.1 ± 7.4 bat/min vs 69.8 ± 14.3 bat/min, p < 0.01). The use of the simple test of deep breathing allowed us to demonstrate that adult young footballers have a significantly lower basal HR and higher parasympathetic response in comparison to untrained subjects.展开更多
The aim of this study was to investigate the inter-fraction variations, patient comfort and knowledge at Charlotte Maxeke Johannesburg Academic Hospital (CMJAH). The differences in set-up that occurred between treatme...The aim of this study was to investigate the inter-fraction variations, patient comfort and knowledge at Charlotte Maxeke Johannesburg Academic Hospital (CMJAH). The differences in set-up that occurred between treatment sessions for the left sided breast patients were observed and recorded. Measurements of routine set-up variation for 24 patients were performed by matching the cone beam computed tomography (CBCT) and the planning computed tomography (CT). Scans of all five fractions per patient were used to quantify the setup variations with standard deviation (SD) in all the three directions (anterior posterior, left right, and superior inferior). The patients DIBH comfort and knowledge was also evaluated. The average translational errors for the anterior posterior (AP, z), left-right (LR, x), and Superior-inferior (SI, y) directions were 0.40 cm, 0.40 cm, and 0.40 cm, respectively. The translation variation of the three directions showed statistical significance (P < 0.05). On comfort and knowledge investigation, among all participants, 80% moderately agreed that the therapist’s instructions for operating the deep inspiration breath hold (DIBH) technique were easy to understand, and 63.33% indicated that their comfort with the DIBH technique was neutral or average. The inter-fraction variations in patients with left-sided breast cancer were qualitatively analyzed. Significant shifts between CBCT and planning CT images were observed. The daily treatment verification could assist accurate dose delivery.展开更多
Objective:To analyze the application of deep inspiration breath hold technique in radiotherapy after breast-conserving surgery for left breast cancer and the improvement of cardiac dose.Methods:A total of 45 patients ...Objective:To analyze the application of deep inspiration breath hold technique in radiotherapy after breast-conserving surgery for left breast cancer and the improvement of cardiac dose.Methods:A total of 45 patients with left breast cancer treated in our hospital after breast-conserving surgery were selected,and the selection time was set from January 2020 to August 2022.All patients received radiotherapy.The right breast,heart,and lung volumes,and dose parameters of the heart,lungs,right breast,and left anterior descending coronary artery were compared under free breathing(FB)and deep inspiration breath hold(DIBH)technical modes.Results:The heart volume of the DIBH group was smaller than that of the FB group,and the left and right lung volumes were significantly larger than those of the FB group.In the DIBH group,the heart dose parameters V5,proper lung dose parameters,and left anterior descending coronary artery dose parameters were found lower than that of the FB group,and the differences were statistically significant(P<0.05).Conclusion:Compared with FB,the DIBH technique can reduce the heart’s size and increase the lung volume when used for radiotherapy after breast-conserving surgery for left breast cancer.It also reduces the dose to the heart,right lung,and left anterior descending coronary artery,thus protecting the heart and lungs.展开更多
Everyone involved in Beijing’s Olympic Games held their breath last week, not because of the city’s famously polluted air , but in anticipation of the results of an experiment that could help to clean it up.
A technique for multiple deep-inspiration breath-hold (DIBH) volumetric modulated arc therapy (VMAT) for a lung tumor has been proposed with 10 MV flattening-filter-free beams and an image sensor measuring a distance ...A technique for multiple deep-inspiration breath-hold (DIBH) volumetric modulated arc therapy (VMAT) for a lung tumor has been proposed with 10 MV flattening-filter-free beams and an image sensor measuring a distance map to thorax surface. Planning CT images were acquired under a DIBH condition and a clinical target volume (CTV) was contoured. This procedure was repeated five times and an internal target volume (ITV) among the multiple DIBHs was created by integrating the five CTVs. A planning target volume (PTV) was defined by adding an isotropic margin of 5 mm to the ITV. Immediately before treatment, a 30-second half-arc cone-beam computer tomography (CBCT) imaging was performed under another DIBH condition, and the couch was repositioned so that tumor may be located inside the PTV contours. An infrared distance measurement device having laser diodes and an image sensor was attached to the couch, and a distance map to the patient thorax surface was recorded as a reference during still another DIBH condition. A half-arc segmented VMAT beams with two beam interrupts were delivered to the patient under multiple DIBHs, where the delivery time of each of the three segmented beams was 30 seconds. During the beam delivery, the distance map was monitored in real time to confirm that the distance to the thorax surface remained unchanged. In-treatment CBCT images suggested that the tumor position at the time of tumor registration was accurately reproduced during the DIBH VMAT delivery.展开更多
The purpose of this study was to analyze motion of the left anterior descending coronary artery (LAD) and left ventricle during normal breathing and deep inspiration breath hold (DIBH). This is a dosimetric study util...The purpose of this study was to analyze motion of the left anterior descending coronary artery (LAD) and left ventricle during normal breathing and deep inspiration breath hold (DIBH). This is a dosimetric study utilizing free-breathing and static DIBH scans from eleven patients treated with radiotherapy for breast cancer. The anterior-posterior displacement along the length of the LAD was measured in each respiratory phase. Standard treatment plans targeting the whole breast without treatment of the internal mammary lymph nodes were generated and dose to the LAD and LV calculated. Non-uniform movement of the LAD during respiratory maneuvers with the proximal third exhibiting the greatest displacement was observed. In DIBH compared to end-expiration (EP), the mean posterior displacement of the proximal 1/3 of the LAD was 8.99 mm, the middle 1/3 of the artery was 6.37 mm, and the distal 1/3 was 3.27 mm. In end-inspiration (IP) compared to end-expiration the mean posterior displacements of the proximal 1/3 of the LAD was 2.08 mm, the middle 1/3 of the artery was 0.91 mm, and the distal 1/3 was 0.97 mm. Mean doses to the LAD using tangential treatment fields and a prescribed dose of 50.4 Gy were 11.32 Gy in EP, 8.98 Gy in IP, and 3.50 Gy in DIBH. Mean doses to the LV were 2.38 Gy in EP, 2.31 Gy in IP, and 1.24 Gy in DIBH. In conclusion, inspiration and especially DIBH, cause a displacement of the origin and proximal 2/3 of the LAD away from the chest wall, resulting in sparing of the most critical segment of the artery during tangential radiotherapy.展开更多
125 μm-breath sensor with high sensitivity and rapid response was prepared by using n-type Si: Au material. Its sensitivity coefficient and time constant were 4 V.sec / L and 38 msec, respec-tively. Its working princ...125 μm-breath sensor with high sensitivity and rapid response was prepared by using n-type Si: Au material. Its sensitivity coefficient and time constant were 4 V.sec / L and 38 msec, respec-tively. Its working principle was based on ano- malous resistance effect, which not only increa- sed the sensitivity, but also reduced its time con-stant greatly. Its signal processing system can select the breath signals and work stably. Therefore, the small changes of breath system can be measured and, especially, patient’s breath rate can be monitored at a distance.展开更多
文摘Parasympathetic function can be assessed by the deep breathing test (DB) as a simple and reproducible cardiovascular reflex. The aim of this study is to use this test to compare the vagal response of a young footballers group to of age-matched untrained normal subjects. Deep breathing test was performed in 2 groups: one of 20 adult young footballers (average age of 19.3 ± 0.6 years), and a second age-matched group of 20 untrained subjects (average age of 19.6 ± 0.6 years). Subjects underwent the DB test after 30 min resting in supine position, and responses were expressed as a percentage of variation of heart rate during the stimulation. Student’s t-test was used to evaluate statistical differences among the two groups for all parameters (vagal response, heart rate, VO2max….) and considering p < 0.05 as a significant difference. The results showed that vagal response to deep breathing test was significantly higher in the young footballers when compared to the untrained controls (72.6% ± 16.2% vs 55.0% ± 12.8%, respectively, p = 0.03). The basal heart rate was significantly lower in footballers than in the controls group (52.1 ± 7.4 bat/min vs 69.8 ± 14.3 bat/min, p < 0.01). The use of the simple test of deep breathing allowed us to demonstrate that adult young footballers have a significantly lower basal HR and higher parasympathetic response in comparison to untrained subjects.
文摘The aim of this study was to investigate the inter-fraction variations, patient comfort and knowledge at Charlotte Maxeke Johannesburg Academic Hospital (CMJAH). The differences in set-up that occurred between treatment sessions for the left sided breast patients were observed and recorded. Measurements of routine set-up variation for 24 patients were performed by matching the cone beam computed tomography (CBCT) and the planning computed tomography (CT). Scans of all five fractions per patient were used to quantify the setup variations with standard deviation (SD) in all the three directions (anterior posterior, left right, and superior inferior). The patients DIBH comfort and knowledge was also evaluated. The average translational errors for the anterior posterior (AP, z), left-right (LR, x), and Superior-inferior (SI, y) directions were 0.40 cm, 0.40 cm, and 0.40 cm, respectively. The translation variation of the three directions showed statistical significance (P < 0.05). On comfort and knowledge investigation, among all participants, 80% moderately agreed that the therapist’s instructions for operating the deep inspiration breath hold (DIBH) technique were easy to understand, and 63.33% indicated that their comfort with the DIBH technique was neutral or average. The inter-fraction variations in patients with left-sided breast cancer were qualitatively analyzed. Significant shifts between CBCT and planning CT images were observed. The daily treatment verification could assist accurate dose delivery.
文摘Objective:To analyze the application of deep inspiration breath hold technique in radiotherapy after breast-conserving surgery for left breast cancer and the improvement of cardiac dose.Methods:A total of 45 patients with left breast cancer treated in our hospital after breast-conserving surgery were selected,and the selection time was set from January 2020 to August 2022.All patients received radiotherapy.The right breast,heart,and lung volumes,and dose parameters of the heart,lungs,right breast,and left anterior descending coronary artery were compared under free breathing(FB)and deep inspiration breath hold(DIBH)technical modes.Results:The heart volume of the DIBH group was smaller than that of the FB group,and the left and right lung volumes were significantly larger than those of the FB group.In the DIBH group,the heart dose parameters V5,proper lung dose parameters,and left anterior descending coronary artery dose parameters were found lower than that of the FB group,and the differences were statistically significant(P<0.05).Conclusion:Compared with FB,the DIBH technique can reduce the heart’s size and increase the lung volume when used for radiotherapy after breast-conserving surgery for left breast cancer.It also reduces the dose to the heart,right lung,and left anterior descending coronary artery,thus protecting the heart and lungs.
文摘Everyone involved in Beijing’s Olympic Games held their breath last week, not because of the city’s famously polluted air , but in anticipation of the results of an experiment that could help to clean it up.
文摘A technique for multiple deep-inspiration breath-hold (DIBH) volumetric modulated arc therapy (VMAT) for a lung tumor has been proposed with 10 MV flattening-filter-free beams and an image sensor measuring a distance map to thorax surface. Planning CT images were acquired under a DIBH condition and a clinical target volume (CTV) was contoured. This procedure was repeated five times and an internal target volume (ITV) among the multiple DIBHs was created by integrating the five CTVs. A planning target volume (PTV) was defined by adding an isotropic margin of 5 mm to the ITV. Immediately before treatment, a 30-second half-arc cone-beam computer tomography (CBCT) imaging was performed under another DIBH condition, and the couch was repositioned so that tumor may be located inside the PTV contours. An infrared distance measurement device having laser diodes and an image sensor was attached to the couch, and a distance map to the patient thorax surface was recorded as a reference during still another DIBH condition. A half-arc segmented VMAT beams with two beam interrupts were delivered to the patient under multiple DIBHs, where the delivery time of each of the three segmented beams was 30 seconds. During the beam delivery, the distance map was monitored in real time to confirm that the distance to the thorax surface remained unchanged. In-treatment CBCT images suggested that the tumor position at the time of tumor registration was accurately reproduced during the DIBH VMAT delivery.
文摘The purpose of this study was to analyze motion of the left anterior descending coronary artery (LAD) and left ventricle during normal breathing and deep inspiration breath hold (DIBH). This is a dosimetric study utilizing free-breathing and static DIBH scans from eleven patients treated with radiotherapy for breast cancer. The anterior-posterior displacement along the length of the LAD was measured in each respiratory phase. Standard treatment plans targeting the whole breast without treatment of the internal mammary lymph nodes were generated and dose to the LAD and LV calculated. Non-uniform movement of the LAD during respiratory maneuvers with the proximal third exhibiting the greatest displacement was observed. In DIBH compared to end-expiration (EP), the mean posterior displacement of the proximal 1/3 of the LAD was 8.99 mm, the middle 1/3 of the artery was 6.37 mm, and the distal 1/3 was 3.27 mm. In end-inspiration (IP) compared to end-expiration the mean posterior displacements of the proximal 1/3 of the LAD was 2.08 mm, the middle 1/3 of the artery was 0.91 mm, and the distal 1/3 was 0.97 mm. Mean doses to the LAD using tangential treatment fields and a prescribed dose of 50.4 Gy were 11.32 Gy in EP, 8.98 Gy in IP, and 3.50 Gy in DIBH. Mean doses to the LV were 2.38 Gy in EP, 2.31 Gy in IP, and 1.24 Gy in DIBH. In conclusion, inspiration and especially DIBH, cause a displacement of the origin and proximal 2/3 of the LAD away from the chest wall, resulting in sparing of the most critical segment of the artery during tangential radiotherapy.
文摘125 μm-breath sensor with high sensitivity and rapid response was prepared by using n-type Si: Au material. Its sensitivity coefficient and time constant were 4 V.sec / L and 38 msec, respec-tively. Its working principle was based on ano- malous resistance effect, which not only increa- sed the sensitivity, but also reduced its time con-stant greatly. Its signal processing system can select the breath signals and work stably. Therefore, the small changes of breath system can be measured and, especially, patient’s breath rate can be monitored at a distance.