期刊文献+
共找到10,344篇文章
< 1 2 250 >
每页显示 20 50 100
Repeatability,interocular correlation and agreement of optic nerve head vessel density in healthy eyes:a sweptsource optical coherence tomographic angiography study
1
作者 Dan-Qi Fang Da-Wei Yang +2 位作者 Xiao-Ting Mai Carol Y Cheung Hao-Yu Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第5期896-903,共8页
AIM:To assess the repeatability,interocular correlation,and agreement of quantitative swept-source optical coherence tomography angiography(OCTA)optic nerve head(ONH)parameters in healthy subjects.METHODS:Thir ty-thre... AIM:To assess the repeatability,interocular correlation,and agreement of quantitative swept-source optical coherence tomography angiography(OCTA)optic nerve head(ONH)parameters in healthy subjects.METHODS:Thir ty-three healthy subjects were enrolled.The ONH of both eyes were imaged four times by a swept-source-OCTA using a 3 mm×3 mm scanning protocol.Images of the radial peripapillary capillary were analyzed by a customized Matlab program,and the vessel density,fractal dimension,and vessel diameter index were measured.The repeatability of the four scans was determined by the intraclass correlation coefficient(ICC).The most well-centered optic disc from the four repeated scans was then selected for the interocular correlation and agreement analysis using the Pearson correlation coefficient,ICC and Bland-Altman plots.RESULTS:All swept-source-OCTA ONH parameters exhibited certain repeatability,with ICC>0.760 and coefficient of variation(CoV)≤7.301%.The obvious interocular correlation was observed for papillary vessel density(ICC=0.857),vessel diameter index(ICC=0.857)and fractal dimension(ICC=0.906),while circumpapillary vessel density exhibited moderate interocular correlation(ICC=0.687).Bland-Altman plots revealed an agreement range of-5.26%to 6.21%for circumpapillary vessel density.CONCLUSION:OCTA ONH parameters demonstrate good repeatability in healthy subjects.The interocular correlations of papillary vessel density,fractal dimension and vessel diameter index are high,but the correlation for circumpapillary vessel density is moderate. 展开更多
关键词 interocular correlation REPEATABILITY optic nerve head optical coherence tomography angiography vessel density
下载PDF
Finesse measurement for high-power optical enhancement cavity
2
作者 陆心怡 柳兴 +3 位作者 田其立 王焕 汪嘉俊 颜立新 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期414-421,共8页
Finesse is a critical parameter for describing the characteristics of an optical enhancement cavity(OEC). This paper first presents a review of finesse measurement techniques, including a comparative analysis of the a... Finesse is a critical parameter for describing the characteristics of an optical enhancement cavity(OEC). This paper first presents a review of finesse measurement techniques, including a comparative analysis of the advantages, disadvantages, and potential limitations of several main methods from both theoretical and practical perspectives. A variant of the existing method called the free spectral range(FSR) modulation method is proposed and compared with three other finesse measurement methods, i.e., the fast-switching cavity ring-down(CRD) method, the rapidly swept-frequency(SF) CRD method, and the ringing effect method. A high-power OEC platform with a high finesse of approximately 16000 is built and measured with the four methods. The performance of these methods is compared, and the results show that the FSR modulation method and the fast-switching CRD method are more suitable and accurate than the other two methods for high-finesse OEC measurements. The CRD method and the ringing effect method can be implemented in open loop using simple equipment and are easy to perform. Additionally, recommendations for selecting finesse measurement methods under different conditions are proposed, which benefit the development of OEC and its applications. 展开更多
关键词 optical enhancement cavity finesse measurement cavity ring-down ringing effect
下载PDF
A novel indirect optical method for rock stress measurement using microdeformation field analysis
3
作者 Yujie Feng Peng-Zhi Pan +2 位作者 Zhaofeng Wang Xufeng Liu Shuting Miao 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第9期3616-3628,共13页
Stress measurement plays a crucial role in geomechanics and rock engineering,especially for the design and construction of large-scale rock projects.This paper presents a novel method,based on the traditional stress r... Stress measurement plays a crucial role in geomechanics and rock engineering,especially for the design and construction of large-scale rock projects.This paper presents a novel method,based on the traditional stress relief approach,for indirectly measuring rock stress using optical techniques.The proposed method allows for the acquisition of full-field strain evolution on the borehole’s inner wall before and after disturbance,facilitating the determination of three-dimensional(3D)stress information at multiple points within a single borehole.The study focuses on presenting the method’s theoretical framework,laboratory validation results,and equipment design conception.The theoretical framework comprises three key components:the optical imaging method of the borehole wall,the digital image correlation(DIC)method,and the stress calculation procedure.Laboratory validation tests investigate strain field distribution on the borehole wall under varying stress conditions,with stress results derived from DIC strain data.Remarkably,the optical method demonstrates better measurement accuracy during the unloading stage compared to conventional strain gauge methods.At relatively high stress levels,the optical method demonstrates a relative error of less than 7%and an absolute error within 0.5 MPa.Furthermore,a comparative analysis between the optical method and the conventional contact resistance strain gauge method highlights the optical method’s enhanced accuracy and stability,particularly during the unloading stage.The proposed optical stress measurement device represents a pioneering effort in the application of DIC technology to rock engineering,highlighting its potential to advance stress measurement techniques in the field. 展开更多
关键词 Rock stress measurement optical technology Digital image correlation(DIC)technology Micro-deformation field
下载PDF
Phase-Based Optical Flow Method with Optimized Parameter Settings for Enhancing Displacement Measurement Adaptability
4
作者 Zhaoxin Peng Menglian Liu +2 位作者 Zhiliang Wang Wei Liu Xian Wang 《Open Journal of Applied Sciences》 2024年第5期1165-1184,共20页
To enhance the applicability and measurement accuracy of phase-based optical flow method using complex steerable pyramids in structural displacement measurement engineering applications, an improved method of optimizi... To enhance the applicability and measurement accuracy of phase-based optical flow method using complex steerable pyramids in structural displacement measurement engineering applications, an improved method of optimizing parameter settings is proposed. The optimized parameters include the best measurement points of the Region of Interest (ROI) and the levels of pyramid filters. Additionally, to address the issue of updating reference frames in practical applications due to the difficulty in estimating the maximum effective measurement value, a mechanism for dynamically updating reference frames is introduced. Experimental results demonstrate that compared to representative image gradient-based displacement measurement methods, the proposed method exhibits higher measurement accuracy in engineering applications. This provides reliable data support for structural damage identification research based on vibration signals and is expected to broaden the engineering application prospects for structural health monitoring. 展开更多
关键词 Displacement measurement Phase-Based optical Flow Optimized Parameter Setting
下载PDF
Structural measurements and vessel density of spectraldomain optic coherence tomography in early,moderate,and severe primary angle-closure glaucoma 被引量:2
5
作者 Wei Jiang Nan Jiang +3 位作者 Gui-Bo Liu Jing Lin Cui Li Gui-Qiu Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第7期1100-1109,共10页
AIM:To compare the macular ganglion cell-inner plexiform layer(GCIPL)thickness,retinal nerve fiber layer(RNFL)thickness,optic nerve head(ONH)parameters,and retinal vessel density(VD)measured by spectral-domain optical... AIM:To compare the macular ganglion cell-inner plexiform layer(GCIPL)thickness,retinal nerve fiber layer(RNFL)thickness,optic nerve head(ONH)parameters,and retinal vessel density(VD)measured by spectral-domain optical coherence tomography(SD-OCT)and analyze the correlations between them in the early,moderate,severe primary angle-closure glaucoma(PACG)and normal eyes.METHODS:Totally 70 PACG eyes and 20 normal eyes were recruited for this retrospective analysis.PACG eyes were further separated into early,moderate,or severe PACG eyes using the Enhanced Glaucoma Staging System(GSS2).The GCIPL thickness,RNFL thickness,ONH parameters,and retinal VD were measured by SD-OCT,differences among the groups and correlations within the same group were calculated.RESULTS:The inferior and superotemporal sectors of the GCIPL thickness,rim area of ONH,average and inferior sector of the retinal VD were significantly reduced(all P<0.05)in the early PACG eyes compared to the normal and the optic disc area,cup to disc ratio(C/D),and cup volume were significantly higher(all P<0.05);but the RNFL was not significant changes in early and moderate PACG.In severe group,the GCIPL and RNFL thickness were obvious thinning with retinal VD were decreasing as well as C/D and cup volume increasing than other three groups(all P<0.01).In the early PACG subgroup,there were significant positive correlations between retinal VD and GCIPL thickness(except superonasal and inferonasal sectors,r=0.573 to 0.641,all P<0.05),superior sectors of RNFL thickness(r=0.055,P=0.049).More obvious significant positive correlations were existed in moderate PACG eyes between retinal VD and superior sectors of RNFL thickness(r=0.650,P=0.022),and temporal sectors of RNFL thickness(r=0.740,P=0.006).In the severe PACG eyes,neither GCIPL nor RNFL thickness was associated with retinal VD.CONCLUSION:The ONH damage and retinal VD loss appears earlier than RNFL thickness loss in PACG eyes.As the PACG disease progressed from the early to the moderate stage,the correlations between the retinal VD and RNFL thickness increases. 展开更多
关键词 optic coherence tomography primary angle-closure glaucoma ganglion cell-inner plexiform layer retinal nerve fiber layer optic nerve head retinal vessel density
下载PDF
Evaluation of optic nerve head vessels density changes after phacoemulsification cataract surgery using optical coherence tomography angiography 被引量:1
6
作者 Ze-Hui Zhu Yin-Ying Zhao +4 位作者 Rui Zou Han Zou Jia-Yan Fang Ping-Jun Chang Yun-E Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第6期884-890,共7页
·AIM:To evaluate optic nerve head(ONH)vessel density(VD)changes after cataract surgery using optical coherence tomography angiography(OCTA).·METHODS:This was a prospective observational study.Thirty-four eye... ·AIM:To evaluate optic nerve head(ONH)vessel density(VD)changes after cataract surgery using optical coherence tomography angiography(OCTA).·METHODS:This was a prospective observational study.Thirty-four eyes with mild/moderate cataracts were included.ONH scans were obtained before and 3mo after cataract surgery using OCTA.Radial peripapillary capillary(RPC)density,all VD,large VD and retinal nerve fiber layer thickness(RNFLT)in total disc,inside disc,and different peripapillary sectors were assessed and analyzed.Image quality score(QS),fundus photography grading and bestcorrected visual acuity(BCVA)were also collected,and correlation analyses were performed between VD change and these parameters.·RESULTS:Compared with baseline,both RPC and all VD increased in inside disc area 3mo postoperatively(from 47.5%±5.3%to 50.2%±3.7%,and from 57.87%±4.30%to 60.47%±3.10%,all P<0.001),but no differences were observed in peripapillary area.However,large VD increased from 5.63%±0.77%to 6.47%±0.72%in peripapillary ONH region(P<0.001).RPC decreased in inferior and superior peripapillary ONH parts(P=0.019,<0.001 respectively).There were obvious negative correlations between RPC change and large VD change in inside disc,superior-hemi,and inferior-hemi(r=-0.419,-0.370,and-0.439,P=0.017,0.044,and 0.015,respectively).No correlations were found between VD change and other parameters including QS change,fundus photography grading,postoperative BCVA,and postoperative peripapillary RNFLT.·CONCLUSION:RPC density and all VD in the inside disc ONH region increase 3mo after surgery in patients with mild to moderate cataract.No obvious VD changes are found in peripapillary area postoperatively. 展开更多
关键词 PHACOEMULSIFICATION CATARACT optical coherence tomography angiography vessel density optic nerve head
下载PDF
Laboratory demonstration of geopotential measurement using transportable optical clocks 被引量:1
7
作者 刘道信 曹健 +6 位作者 袁金波 崔凯枫 袁易 张平 晁思嘉 舒华林 黄学人 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第1期272-277,共6页
We report an experimental demonstration of geopotential difference measurement using a pair of transportable ^(40)Ca^(+) optical clocks(TOC-729-1 and TOC-729-3)in the laboratory,each of them has an uncertainty of 1.3&... We report an experimental demonstration of geopotential difference measurement using a pair of transportable ^(40)Ca^(+) optical clocks(TOC-729-1 and TOC-729-3)in the laboratory,each of them has an uncertainty of 1.3×10^(−17) and an instability of 4.8×10^(−15)/√τ.Referenced to a stationary clock of TOC-729-1,the geopotential difference measurements are realized by moving TOC-729-3 to three different locations and the relevant altitude differences are measured with uncertainties at the level of 20 cm.After correcting the systematic shifts(including gravitational red shift),the two-clock frequency difference is measured to be–0.7(2.2)×10^(−17),considering both the statistic(1.0×10^(−17))and the systematic(1.9×10^(−17))uncertainties.The frequency difference between these two clocks is within their respective uncertainties,verifying the reliability of transportable ^(40)Ca^(+) optical clocks at the low level of 10^(−17). 展开更多
关键词 geopotential difference measurement transportable optical clock repeatability evaluation of clocks
下载PDF
Measurement of electron density and electron temperature of a cascaded arc plasma using laser Thomson scattering compared to an optical emission spectroscopic approach 被引量:2
8
作者 Yong WANG Cong LI +2 位作者 Jielin SHI Xingwei WU Hongbin DING 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第11期23-30,共8页
As advanced linear plasma sources, cascaded arc plasma devices have been used to generate steady plasma with high electron density, high particle flux and low electron temperature. To measure electron density and elec... As advanced linear plasma sources, cascaded arc plasma devices have been used to generate steady plasma with high electron density, high particle flux and low electron temperature. To measure electron density and electron temperature of the plasma device accurately, a laser Thomson scattering(LTS) system, which is generally recognized as the most precise plasma diagnostic method, has been established in our lab in Dalian University of Technology. The electron density has been measured successfully in the region of 4.5?×10^19m^-3 to7.1?×10^20m^-3 and electron temperature in the region of 0.18 eV to 0.58 eV. For comparison,an optical emission spectroscopy(OES) system was established as well. The results showed that the electron excitation temperature(configuration temperature) measured by OES is significantly higher than the electron temperature(kinetic electron temperature) measured by LTS by up to 40% in the given discharge conditions. The results indicate that the cascaded arc plasma is recombining plasma and it is not in local thermodynamic equilibrium(LTE). This leads to significant error using OES when characterizing the electron temperature in a non-LTE plasma. 展开更多
关键词 laser Thomson scattering optical emission spectroscopy cascaded arc plasma electron density electron temperature electron excitation temperature
下载PDF
A New Method for In-Situ Measurement of Internal Solitary Waves Based on the Stimulated Raman Scattering in Optical Fibers
9
作者 WANG Jing ZHANG Meng +4 位作者 MIAO Xiangying YANG Zhonghao LI Zhixin HUO Dianheng MIAO Hongli 《Journal of Ocean University of China》 SCIE CAS CSCD 2023年第3期658-664,共7页
In-situ measurement of internal solitary waves(ISWs)is complicated in the ocean due to their randomness.At present,the ISWs are mainly detected by the chain structure of conductivity-temperature-depth systems(CTDs)or ... In-situ measurement of internal solitary waves(ISWs)is complicated in the ocean due to their randomness.At present,the ISWs are mainly detected by the chain structure of conductivity-temperature-depth systems(CTDs)or temperature sensors.The high cost limits the spatial resolution,which ultimately affects the measuring accuracy of the ISW amplitude.In this paper,we developed an experimental measurement system for detecting ISWs based on the stimulated Raman scattering in distributed optical fibers.This system has the advantages of high precision,low cost,and easy operation.The experimental results show that the system is consistent with CTDs in the measurement of vertical ocean temperature variation.The spatial resolution of the system can reach 1.0 m and the measuring accuracy of temperature is 0.2℃.We successfully detected 3 ISWs by the system in the South China Sea and two optical remote sensing images collected on May 18,2021,the same day of two detected ISWs,verify the occurrence of the measured ISWs.We used the image pairs method to calculate the phase velocity of ISW and the result is 1.71 ms^(-1).By extracting the distances between wave packets,it can be found that the semi-diurnal tide generates the detected ISWs.The impact of the tidal current velocity on the ISW in amplitude is undeniable.Undoubtedly,the system has a great application prospect for detecting ISWs and other dynamic phenomena in the ocean. 展开更多
关键词 internal solitary wave optical fiber stimulated Raman scattering in-situ measurement
下载PDF
Local density of optical states calculated by the mode spectrum in stratified media
10
作者 傅廷 陈静瑄 +5 位作者 王学友 戴迎秋 周旭彦 王宇飞 王明金 郑婉华 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第4期135-141,共7页
The local density of optical states(LDOS)is an important physical concept,which can characterize the spontaneous emission of microcavities.In order to calculate the LDOS,the relationship between the mode spectrum and ... The local density of optical states(LDOS)is an important physical concept,which can characterize the spontaneous emission of microcavities.In order to calculate the LDOS,the relationship between the mode spectrum and the LDOS is established.Then,based on the transfer matrix method and the effective resonator model,the leaky loss of the leaky mode and the mode spectrum in the one-dimensional photonic bandgap crystal waveguide are calculated,results of which indicate that the mode spectrum can characterize the leaky loss of the leaky mode.At last,the density of optical states(DOS),and the LDOS in each layer are calculated.The partial DOS and the partial LDOS in the quantum well,related to the fundamental leaky mode,can be used to find out the optimal location of the quantum well in the defect layer to couple more useful photons into the lasing mode for lasers. 展开更多
关键词 local density of optical states mode spectrum transfer matrix method
下载PDF
Changes of retinal vessel density in low to moderate myopic eyes with orthokeratology evaluated by optical coherence tomography angiography
11
作者 Jia-Hui Shi Yi-Ping Zhao +4 位作者 Gang Liu Xin-Yi Huang Li-Li Lang Wan-Cheng Jia Ji-Li Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第9期1512-1520,共9页
AIM:To explore the effect of orthokeratology(OK)fitting on retinal vessel density in low to moderate myopia adolescents by using optical coherence tomography angiography.METHODS:Children aged 10 to 14y with a cyclople... AIM:To explore the effect of orthokeratology(OK)fitting on retinal vessel density in low to moderate myopia adolescents by using optical coherence tomography angiography.METHODS:Children aged 10 to 14y with a cycloplegic spherical equivalent refraction of−0.50 diopter(D)to−5.00 D and astigmatism with more than−1.50 D were recruited.The enrolled adolescents were divided into OK group and spectacle group.During regular followup,adolescents were measured respectively at pre-wear,1,3,and 6mo after treatment.The follow-up included uncorrected distance visual acuity(UDVA),axial length(AL),superficial capillary plexus density(SCPD),deep capillary plexus density(DCPD),central retinal thickness(CRT),foveal avascular zone area(FAZ-A),foveal avascular zone perimeter(FAZ-P)and foveal vessel density in a 300-μmwide region around foveal avascular zone(FD-300).The collected data were analyzed using statistical methods.RESULTS:By one month,SCPD significantly increased in the fovea and superior retina,and DCPD significantly increased inferiorly in OK group compared to spectacle group(P<0.05).By three months,there were significant increases in SCPD in the fovea and inferior retina,and DCPD in the parafovea,superior,and inferior retina in OK group(P<0.05),while the increase in SCPD and DCPD in the fovea were observed by six months(P<0.05).The FD-300 significantly increased at every follow-up in OK group compared to spectacle group(P<0.05).No significant differences in the CRT,FAZ-A and FAZ-P and FD-300 were observed between two groups(P>0.05).OK group showed a significant improvement in UDVA after wearing OK,compared to spectacle group(P<0.01),while the AL did not show a significant difference between two groups(P>0.05).CONCLUSION:Short-term OK worn can increase local retinal vessel density in adolescents with low-to-moderate myopia. 展开更多
关键词 optical coherence tomography angiography ORTHOKERATOLOGY MYOPIA axial length retinal capillary plexus density
下载PDF
Quantum-enhanced optical precision measurement assisted by low-frequency squeezed vacuum states
12
作者 康国辉 冯晋霞 +2 位作者 程琳 李渊骥 张宽收 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第10期438-442,共5页
Stable low-frequency squeezed vacuum states at a wavelength of 1550 nm were generated.By controlling the squeezing angle of the squeezed vacuum states,two types of low-frequency quadrature-phase squeezed vacuum states... Stable low-frequency squeezed vacuum states at a wavelength of 1550 nm were generated.By controlling the squeezing angle of the squeezed vacuum states,two types of low-frequency quadrature-phase squeezed vacuum states and quadrature-amplitude squeezed vacuum states were obtained using one setup respectively.A quantum-enhanced fiber Mach–Zehnder interferometer(FMZI)was demonstrated for low-frequency phase measurement using the generated quadrature-phase squeezed vacuum states that were injected.When phase modulation was measured with the quantumenhanced FMZI,there were above 3 dB quantum improvements beyond the shot-noise limit(SNL)from 40 kHz to 200 kHz,and 2.3 dB quantum improvement beyond the SNL at 20 kHz was obtained.The generated quadrature-amplitude squeezed vacuum state was applied to perform low-frequency amplitude modulation measurement for sensitivity beyond the SNL based on optical fiber construction.There were about 2 dB quantum improvements beyond the SNL from 60 kHz to 200 kHz.The current scheme proves that quantum-enhanced fiber-based sensors are feasible and have potential applications in high-precision measurements based on fiber,particularly in the low-frequency range. 展开更多
关键词 squeezed vacuum states fiber Mach–Zehnder interferometer optical precision measurement
下载PDF
Measurement of macular pigment optical density among healthy Chinese people and patients with early-stage age-related macular degeneration 被引量:1
13
作者 Xue-Tao Ren Hong Gu +8 位作者 Xu Han Jun-Yan Zhang Xue Li Xiu-Fen Yang Jun Xu Torkel Snellingen Xi-Pu Liu Ning-Li Wang Ning-Pu Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第6期1190-1195,共6页
AIMTo measure the macular pigment optical density (MPOD) in healthy Chinese people and patients with early age-related macular degeneration (AMD).METHODSCross-sectional population based study. Demographic and lifestyl... AIMTo measure the macular pigment optical density (MPOD) in healthy Chinese people and patients with early age-related macular degeneration (AMD).METHODSCross-sectional population based study. Demographic and lifestyle characteristics were ascertained by questionnaire. A food frequency questionnaire was completed for all participants. Participants underwent general physical and ophthalmic examinations and MPOD was measured by heterochromatic flicker photometry. Foveal architecture was measured by optical coherence tomography.RESULTSMPOD of 225 participants (122 healthy and 103 early AMD) was 0.48&#x000b1;0.18. Patients with early AMD (0.52&#x000b1;0.19) tended to have higher MPOD levels than healthy people (0.47&#x000b1;0.17), but the difference was not statistically significant (P=0.06). Participants with carrot or corn oil intake every week tended to have higher levels of MPOD (P=0.002 and 0.008 respectively) while those with corn intake had relatively lower level of MPOD (P=0.01). MPOD increased with the center foveal thickness (P=0.01).CONCLUSIONOur findings show that there is no statistically significant association between MPOD and early AMD in the studied population. MPOD is related to center foveal thickness and diets would influence MPOD levels. 展开更多
关键词 age-related macular degeneration DIETS foveal architecture macular pigment optical density
下载PDF
Measuring small longitudinal phase shifts via weak measurement amplification
14
作者 徐凯 胡晓敏 +7 位作者 胡孟军 王宁宁 张超 黄运锋 柳必恒 李传锋 郭光灿 张永生 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期105-111,共7页
Weak measurement amplification,which is considered as a very promising scheme in precision measurement,has been applied to various small physical quantities estimations.Since many physical quantities can be converted ... Weak measurement amplification,which is considered as a very promising scheme in precision measurement,has been applied to various small physical quantities estimations.Since many physical quantities can be converted into phase signals,it is interesting and important to consider measuring small longitudinal phase shifts by using weak measurement.Here,we propose and experimentally demonstrate a novel weak measurement amplification-based small longitudinal phase estimation,which is suitable for polarization interferometry.We realize one order of magnitude amplification measurement of a small phase signal directly introduced by a liquid crystal variable retarder and show that it is robust to the imperfection of interference.Besides,we analyze the effect of magnification error which is never considered in the previous works,and find the constraint on the magnification.Our results may find important applications in high-precision measurements,e.g.,gravitational wave detection. 展开更多
关键词 weak measurement phase estimation quantum optics
下载PDF
Inter-comparison of field snow measurements using different instruments in Türkiye
15
作者 M.Cansaran ERTAŞ A.Arda ŞORMAN 《Journal of Mountain Science》 SCIE CSCD 2024年第10期3368-3379,共12页
Snow is important in Türkiye especially in the mountainous eastern areas where it may stay on the ground for more than half of the year.This region plays a vital role in feeding the water resources of the trans-b... Snow is important in Türkiye especially in the mountainous eastern areas where it may stay on the ground for more than half of the year.This region plays a vital role in feeding the water resources of the trans-boundary Euphrates-Tigris Basin,supporting crucial dams for water supply,irrigation and energy production.Thus,easy,frequent,correct and economical ways of measuring the snowpack is crucial.The snow properties at specific locations in the mountainous eastern regions over the two snow seasons(2018 and 2019)were studied by using different instruments and techniques,snow pit(box/cylinder/wedge cutter types),snow tube(Federal Sampler)and SnoTel(Snowpack Analyzer).The results point out a 1.7%-7.1%variation between different cutter type snow density measurements within snow pit analysis and the long-term utilized snow tube observations show a closer relation to box/cylinder type cutters.As for the continuous SnoTel observations,a variation of 2.4%-9.8%with various cutter types and a 5.9%difference regarding the snow tube density results are detected.These findings indicate a close range among different instruments,but it is the best when all three systems complement each other to characterize the snowpack effectively in the complex terrain since each has its own advantages. 展开更多
关键词 Snow measurements Snow Pit Snow Tube SnoTel Snow density Upper Euphrates Basin
下载PDF
Quantifying peripapillary vessel density and retinal nerve fibre layer in type 1 diabetic children without clinically detectable retinopathy using OCTA
16
作者 Ling Chen Yun Feng +2 位作者 Sha-Sha Zhang Yan-Fang Liu Ping Lin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期278-281,共4页
AIM:To quantify changes in radial peripapillary capillary vessel density(ppVD)and the peripapillary retinal nerve fiber layer(pRNFL)in children with type 1 diabetes without clinical diabetic retinopathy by optical coh... AIM:To quantify changes in radial peripapillary capillary vessel density(ppVD)and the peripapillary retinal nerve fiber layer(pRNFL)in children with type 1 diabetes without clinical diabetic retinopathy by optical coherence tomography angiography(OCTA),providing a basis for early retinopathy in children with type 1 diabetes.METHODS:This was a retrospective study.A total of 30 patients(3–14y)with type 1 diabetes without clinical diabetic retinopathy(NDR group)were included.A total of 30 age-matched healthy subjects were included as the normal control group(CON group).The HbA1c level in the last 3mo was measured once in the NDR group.The pRNFL thickness and ppVD were automatically measured,and the mean pRNFL and ppVD were calculated in the nasal,inferior,temporal,and superior quadrants.The changes in ppVD and pRNFL in the two groups were analyzed.RESULTS:Compared with CON group,the nasal and superior ppVDs decreased in the NDR group(all P<0.01).The thickness of the nasal pRNFL decreased significantly(P<0.01),while the inferior,temporal and superior pRNFLs slightly decreased but not significant in the NDR group(all P>0.05).Person and Spearman correlation analysis of ppVD and pRNFL thickness in each quadrant of the NDR group showed a positive correlation between nasal and superior(all P<0.01),while inferior and temporal had no significant correlation(all P>0.05).There was no significant correlation between the HbA1c level and ppVD and pRNFL in any quadrant(all P>0.05).There was no significant correlation between the course of diabetes mellitus and ppVD and pRNFL in any quadrant(all P>0.05).CONCLUSION:ppVD and pRNFL decrease in eyes of children with type 1 diabetes before clinically detectable retinopathy and OCTA is helpful for early monitoring. 展开更多
关键词 diabetic retinopathy CHILDREN peripapillary vessel density peripapillary retinal nerve fiber layer optical coherence tomography angiography
下载PDF
Retinal capillary plexus in Parkinson’s disease using optical coherence tomography angiography
17
作者 Ioannis Giachos Spyridon Doumazos +6 位作者 Anastasia Tsiogka Konstantina Manoli George Tagaris Tryfon Rotsos Vassilios Kozobolis Ioannis Iliopoulos Marilita Moschos 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期131-136,共6页
AIM:To evaluate the alterations of the retinal microvasculature and foveal avascular zone in patients with Parkinson’s disease(PD)using optical coherence tomography angiography(OCT-A).METHODS:A retrospective study of... AIM:To evaluate the alterations of the retinal microvasculature and foveal avascular zone in patients with Parkinson’s disease(PD)using optical coherence tomography angiography(OCT-A).METHODS:A retrospective study of PD patients examined in the Ophthalmology Department of the General Hospital of Athens,“Georgios Gennimatas”from March 2021 to March 2022 was conducted.Totally 44 patients with PD were included and 18 healthy controls were examined,hence a total of 124 eyes were enrolled in the study.The foveal and parafoveal superficial and deep capillary plexus vascular density(fSCP-VD,fDCP-VD,pSCP-VD,pDCP-CD)and foveal avascular zone(FAZ)were quantified with OCTA.Optical coherence tomography(OCT)was used to measure macular thickness.Our statistical analysis was conducted by using a mixed effect linear regression model.RESULTS:After adjustment for age and gender,the mean parafoveal superficial capillary plexus vascular density(pSCP-VD)and mean parafoveal deep capillary plexus vascular density(pDCP-VD)were significantly decreased in individuals with PD(P<0.001 in both)by-2.35(95%CI-3.3,-1.45)and-7.5(95%CI-10.4,-4.6)respectively.fSCP-VD and fDCP-VD didn’t approach statistical significance.The FAZ area and perimeter were significantly decreased(P<0.001 in both)by-0.1 mm^(2)(95%CI-0.13,-0.07)and-0.49 mm^(2)(95%CI-0.66,-0.32)respectively.Circularity didn’t approach statistical significance.Central retinal thickness(CRT)was significantly decreased in individuals with PD(P<0.001)by-23.1μm(95%CI-30.2,-16)and temporal retinal thickness(TRT)was decreased(P=0.025)by-11μm(95%CI-22,-1.5)while nasal retinal thickness(NRT)only approached statistical significance(P=0.066).CONCLUSION:The mean pSCP-VD,pDCP-VD,CRT and TRT are significantly decreased and FAZ is altered in individuals with PD.These findings can be potentially used as biomarkers for the diagnosis and evaluation of early PD. 展开更多
关键词 Parkinson’s disease optical coherence tomography angiography retinal vascular density foveal avascular zone
下载PDF
Structure,electronic,and nonlinear optical properties of superalkaline M_(3)O(M=Li,Na)doped cyclo[18]carbon
18
作者 刘晓东 卢其亮 罗其全 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期311-317,共7页
Cyclo[18]carbon has received considerable attention thanks to its novel geometric configuration and special electronic structure.Superalkalis have low ionization energy.Doping a superalkali in cyclo[18]carbon is an ef... Cyclo[18]carbon has received considerable attention thanks to its novel geometric configuration and special electronic structure.Superalkalis have low ionization energy.Doping a superalkali in cyclo[18]carbon is an effective method to improve the optical properties of the system because considerable electron transfer occurs.In this paper,the geometry,bonding properties,electronic structure,absorption spectrum,and nonlinear optical(NLO)properties of superalkaline M_(3)O(M=Li,Na)-doped cyclo[18]carbon were studied by using density functional theory.M_(3)O and the C_(18) rings are not coplanar.The C_(18) ring still exhibits alternating long and short bonds.The charge transfer between M_(3)O and C_(18) forms stable[M_(3)O]+[C_(18)]-ionic complexes.C_(18)M_(3)O(M=Li,Na)shows striking optical nonlinearity,i.e.,their first-and second-order hyperpolarizability(βvec andγ||)increase considerably atλ=1907 nm and 1460 nm. 展开更多
关键词 superalkaline doped carbon structure and electronic properties nonlinear optical properties density functional theory(DFT)
下载PDF
Retinal microcirculation changes in prediabetic patients with shortterm increased blood glucose using optical coherence tomography angiography
19
作者 Bing-Jing Lv Hang-Jia Zuo +6 位作者 Qi-Fu Li Fan-Fan Huang Tong Zhang Rong-Xi Huang Shi-Jie Zheng Wen-Juan Wan Ke Hu 《World Journal of Radiology》 2024年第9期407-417,共11页
BACKGROUND Retinal microcirculation alterations are early indicators of diabetic microvascular complications.Optical coherence tomography angiography(OCTA)is a noninvasive method to assess these changes.This study ana... BACKGROUND Retinal microcirculation alterations are early indicators of diabetic microvascular complications.Optical coherence tomography angiography(OCTA)is a noninvasive method to assess these changes.This study analyzes changes in retinal microcirculation in prediabetic patients during short-term increases in blood glucose using OCTA.AIM To investigate the changes in retinal microcirculation in prediabetic patients experiencing short-term increases in blood glucose levels using OCTA.METHODS Fifty volunteers were divided into three groups:Group 1[impaired fasting glucose(IFG)or impaired glucose tolerance(IGT)],Group 2(both IFG and IGT),and a control group.Retinal microcirculation parameters,including vessel density(VD),perfusion density(PD),and foveal avascular zone(FAZ)metrics,were measured using OCTA.Correlations between these parameters and blood glucose levels were analyzed in both the fasting and postprandial states.RESULTS One hour after glucose intake,the central VD(P=0.023),central PD(P=0.026),and parafoveal PD(P<0.001)were significantly greater in the control group than in the fasting group.In Group 1,parafoveal PD(P<0.001)and FAZ circularity(P=0.023)also increased one hour after glucose intake.However,no significant changes were observed in the retinal microcirculation parameters of Group 2 before or after glucose intake(P>0.05).Compared with the control group,Group 1 had a larger FAZ area(P=0.032)and perimeter(P=0.018),whereas Group 2 had no significant differences in retinal microcirculation parameters compared with the control group(P>0.05).Compared with Group 1,Group 2 had greater central VD(P=0.013)and PD(P=0.008)and a smaller FAZ area(P=0.012)and perimeter(P=0.010).One hour after glucose intake,Group 1 had a larger FAZ area(P=0.044)and perimeter(P=0.038)than did the control group,whereas Group 2 showed no significant differences in retinal microcirculation parameters compared with the control group(P>0.05).Group 2 had greater central VD(P=0.042)and PD(P=0.022)and a smaller FAZ area(P=0.015)and perimeter(P=0.016)than Group 1.At fasting,central PD was significantly positively correlated with blood glucose levels(P=0.044),whereas no significant correlations were found between blood glucose levels and OCTA parameters one hour after glucose intake.CONCLUSION A short-term increase in blood glucose has a more pronounced effect on retinal microcirculation in prediabetic patients with either IFG or IGT. 展开更多
关键词 PREDIABETES Blood glucose optical coherence tomography angiography Retinal microcirculation Central vessel density Impaired fasting glucose Impaired glucose tolerance
下载PDF
Plastic optical fiber refractometer for continuous refractive index measurement
20
作者 景宁 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2016年第2期103-105,共3页
This paper investigated the continuous measurement of a refractive index(RI)sensor based on macrobending microoptical plastic fiber(m-POF).The sensing properties of the RI sensor depend on the structure parameter,whic... This paper investigated the continuous measurement of a refractive index(RI)sensor based on macrobending microoptical plastic fiber(m-POF).The sensing properties of the RI sensor depend on the structure parameter,which is the ratio of macrobending radius of m-POF to the radius of fiber itself.The ratio changes with the measurement time increasing because of the water absorption,which introduces an maximum measurement deviation of 7.3×10^(-5) RIU when the immersion time exceeds 40 h.This work indicates that for the sensors based on POF,the measurement time must be taken into consideration for continuous measurement. 展开更多
关键词 plastic optical fiber(POF) water absorption continuous measurement
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部