With the continuous advancement of technology,the application of 3D printing technology in the field of dental medicine is becoming increasingly widespread.This article aims to explore the current applications and fut...With the continuous advancement of technology,the application of 3D printing technology in the field of dental medicine is becoming increasingly widespread.This article aims to explore the current applications and future potential of 3D printing technology in dental medicine and to analyze its benefits and challenges.It first introduces the current state of 3D printing technology in dental implants,crowns,bridges,orthodontics,and maxillofacial surgery.It then discusses the potential applications of 3D printing technology in oral tissue engineering,drug delivery systems,personalized dental prosthetics,and surgical planning.Finally,it analyzes the benefits of 3D printing technology in dental medicine,such as improving treatment accuracy and patient comfort,and shortening treatment times,while also highlighting the challenges faced,such as costs,material choices,and technical limitations.This article aims to provide a reference for professionals in the field of dental medicine and to promote the further application and development of 3D printing technology in this area.展开更多
Objective: To assess the actual practical attitude and knowledge of dental implants among senior dental students and general dentists graduated from some Saudi and Non-Saudi dental schools. Methods: A total of 300 sen...Objective: To assess the actual practical attitude and knowledge of dental implants among senior dental students and general dentists graduated from some Saudi and Non-Saudi dental schools. Methods: A total of 300 senior dental students and general dentists participated in the study. Hard copies of the self-designed, multiple-choice questionnaires were distributed to all participants. The questionnaire consisted of 31 questions in five parts. Data were collected and analyzed using Chi-square test and t-test, where p Results: There is a statistically significant relationship between the participants’ answers, and their dental schools. Participants’ general knowledge, training, and teaching of dental implants, as well as information about restorations retained for the dental implants, were higher among participants from Saudi dental schools than participants from non-Saudi dental schools, while the information about dental implants was higher among participants from non-Saudi dental schools than participants from Saudi dental schools. Conclusion: We conclude that the actual practical attitude and knowledge of dental implants among participants in the current study was insufficient. Therefore, dental implant education in the undergraduate curricula of dental schools surveyed should be updated to include teaching, laboratory training, and preclinical and clinical training.展开更多
BACKGROUND Lateral window approach for sinus floor lift is commonly used for vertical bone augmentation in cases when the residual bone height is less than 5 mm.However,managing cases becomes more challenging when a m...BACKGROUND Lateral window approach for sinus floor lift is commonly used for vertical bone augmentation in cases when the residual bone height is less than 5 mm.However,managing cases becomes more challenging when a maxillary sinus pseudocyst is present or when there is insufficient bone width.In this case,we utilized the bone window prepared during the lateral window sinus lift as a shell for horizontal bone augmentation.This allowed for simultaneous horizontal and vertical bone augmentation immediately after the removal of the maxillary sinus pseudocyst.CASE SUMMARY A 28-year-old female presented to our clinic with the chief complaint of missing upper left posterior teeth.Intraoral examination showed a horizontal deficiency of the alveolar ridge contour.The height of the alveolar bone was approximately 3.6 mm on cone beam computed tomography(CBCT).And a typical well-defined'dome-shaped'lesion in maxillary sinus was observed on CBCT imaging.The lateral bony window was prepared using a piezo-ultrasonic device,then the bony window was fixed to the buccal side of the 26 alveolar ridge using a titanium screw with a length of 10 mm and a diameter of 1.5 mm.The space between the bony window and the alveolar ridge was filled with Bio-Oss,covered with a Bio-Gide collagen membrane,and subsequently sutured.Nine months later,the patient’s bone width increased from 4.8 to 10.5 mm,and the bone height increased from 3.6 to 15.6 mm.Subsequently,a Straumann^(■)4.1 mm×10 mm implant was placed.The final all-ceramic crown restoration was completed four months later,and both clinical and radiographic examinations showed that the implant was successful,and the patient was satisfied with the results.CONCLUSION The bone block harvested from the lateral window sinus lift can be used for simultaneous horizontal bone augmentation acting as a shell for good two-dimensional bone augmentation.展开更多
BACKGROUND Tooth defects can cause elongation of occlusal teeth,leading to insufficient repair space.The combination of dental implant restoration and orthodontic treatment of oblique adjacent teeth has a significant ...BACKGROUND Tooth defects can cause elongation of occlusal teeth,leading to insufficient repair space.The combination of dental implant restoration and orthodontic treatment of oblique adjacent teeth has a significant therapeutic effect.AIM To explore clinical efficacy,bone density,and follow-up of implant and orthodontic treatment for patients with inclined adjacent teeth.METHODS In total,98 patients with oblique adjacent teeth were randomly assigned to implant restoration combined with orthodontic treatment(group A,n=49)or to receive implant restoration alone(group B,n=49).Changes in alveolar ridge bone density and apical bone density were observed before and after treatment in the two groups.Changes in chewing function and language function were compared between the two groups of patients.Follow-up lasted for 12 mo after repair to observe any adverse reactions in the oral cavity.RESULTS The clinical effective rates of group A and group B were 97.96%and 85.71%,respectively,with group A having a higher clinical effective rate than group B.After treatment,the bone density of the alveolar ridge and apical bone in both groups decreased compared to before treatment,while the chewing and language functions improved.The changes in various indicators in group A were more significant.After treatment,the satisfaction rate of group A(97.96%)was higher than that of group B(79.59%).The incidence of adverse reactions in group A(2.04%)was lower than that in group B(24.49%).CONCLUSION The amalgamation of implant restoration and orthodontic treatment for adjacent tilted teeth demonstrates notable clinical efficacy,diminishes alveolar bone resorption,and fosters patient functional rehabilitation while exhibiting negligible adverse reactions.展开更多
Background: Four factors determine the quality of an implantology kit: 1) Heat generated by the drills;2) Morphology of the osteotomy according to the diameter of the implant;3) Efficiency of collecting autologous bon...Background: Four factors determine the quality of an implantology kit: 1) Heat generated by the drills;2) Morphology of the osteotomy according to the diameter of the implant;3) Efficiency of collecting autologous bone;and 4) Osteotomy execution time. Materials and Methods: This article examines the heat produced by drills during osteotomy, focusing on the effect of the following factors: drilling technique;volume of autologous bone harvested;drilling time;implant primary stability;and the percentage of osseointegrated implants after primary healing. Discussion: The four factors mentioned above are analyzed based on the data obtained for sequential, biological, and One Drill milling techniques. Conclusions: 1) One Drill is the fastest technique for performing the osteotomy;2) All techniques stay within the biological temperature range of living bone, with the lowest increase in temperature achieved using One Drill with irrigation;3) The bone harvested showed no statistically significant differences between biological milling and the One Drill technique, both far superior to the sequential technique;and 4) There is no statistically significant difference in the number of osseointegrated implants among the three techniques analyzed.展开更多
Chronic kidney disease (CKD) is a worldwide public health problem that is growing in prevalence and is associated with severe complications. During the progression of the disease, a majority of CKD patients suffer o...Chronic kidney disease (CKD) is a worldwide public health problem that is growing in prevalence and is associated with severe complications. During the progression of the disease, a majority of CKD patients suffer oral complications. Dental implants are currently the most reliable and successful treatment for missing teeth. However, due to complications of CKD such as infections, bone lesions, bleeding risks, and altered drug metabolism, dental implant treatment for renal failure patients on dialysis is more challenging. In this review, we have summarized the characteristics of CKD and previous publications regarding dental treatments for renal failure patients. In addition, we discuss our recent research results and clinical experience in order to provide dental implant practitioners with a clinical guideline for dental implant treatment for renal failure patients undergoing hemodialysis.展开更多
AIM: To assess the failure and bone-to-implant contact rate of dental implants placed on osteoporotic subjects. METHODS: Extensive examination strategies were created to classify studies for this systematic review. ME...AIM: To assess the failure and bone-to-implant contact rate of dental implants placed on osteoporotic subjects. METHODS: Extensive examination strategies were created to classify studies for this systematic review. MEDLINE(via Pub Med) and EMBASE database were examined for studies in English up to and including May 2014. The examination presented a combination of the MeS H words described as follow: "osteoporosis" or "osteopenia" or "estrogen deficiency" AND "implant" or "dental implant" or "osseointegration". Assessment of clinical and/or histological peri-implant conditions in osteoporosis subjects treated with titanium dental implants. The examination included a combination of the MeS H terms described as follow: "osteoporosis" or "osteopenia" or "estrogen deficiency" AND "implant" or "dental implant" or "osseointegration".RESULTS: Of 943 potentially eligible articles, 12 were included in the study. A total of 133 subjects with osteoporosis, 73 subjects diagnosed with osteopenia and 708 healthy subjects were assessed in this systematic review. In these subjects were installed 367, 205, 2981 dental implants in osteoporotic, osteopenic and healthy subjects, respectively. The failure rate of dental implant was 10.9% in osteoporotic subjects, 8.29% in osteopenic and 11.43% in healthy ones. Bone-to-implant contact obtained from retrieved implants ranged between 49.96% to 47.84%, for osteoporosis and non-osteoporotic subjects. CONCLUSION: Osteoporotic subjects presented higher rates of implant loss, however, there is a lower evidence to strengthen or refute the hypothesis that osteoporosis may have detrimental effects on bone healing. Consequently, final conclusions regarding the effect of osteoporosis in dental implant therapy cannot be made at this time. There are no randomized clinical trial accessible for evaluation and the retrospectivenature of the evaluated studies shall be taken in account when interpreting this study.展开更多
Micromotion and fretting damages at the dental implant/bone interface are neglected for the limitation of check methods, but it is particularly important for the initial success of osseointegration and the life time o...Micromotion and fretting damages at the dental implant/bone interface are neglected for the limitation of check methods, but it is particularly important for the initial success of osseointegration and the life time of dental implant. This review article describes the scientific documentation of micromotion and fretting damages on the dental implant/bone interface. The fretting amplitude is less than 30 l^m in vitroand the damage in the interface is acceptable. While in vivo, the micromotion's effect is the combination of damage in tissue level and the real biological reaction.展开更多
At present,dental implant surgery mainly relies on the clinical experience of the doctor and the assistance of preoperative medical imaging.However,there are some problems in dental implant surgery,such as narrow spac...At present,dental implant surgery mainly relies on the clinical experience of the doctor and the assistance of preoperative medical imaging.However,there are some problems in dental implant surgery,such as narrow space,sight obstruction,inaccurate positioning,and high requirements of doctors’proficiency.Therefore,a dental implant robot system(DIRS)guided by optical navigation is developed in this study,with an x-shaped tool and an irregular pentagonal tracer are designed for spatial registration and needle tip positioning strategy respectively.The coordinate system of each unit in DIRS is unified through system calibration,spatial registration,and needle tip positioning strategy.Then the surgical path is planned on the computed tomography(CT)images in the navigation software before operation.The automatic positioning method and the auxiliary positioning method can be used in the operation to achieve accurate positioning and assist doctors to complete the operation.The errors of spatial registration,needle tip positioning strategy,and the overall accuracy of the system were evaluated respectively,and the results showed that they all met the needs of clinical surgery.This study preliminarily verified the feasibility of the precise positioning method for dental surgery robots and provided certain ideas for subsequent related research.展开更多
Dental implants have spread worldwide in dentistry. The risks and complications reported are limited to local issues. However, in this case, a patient complained of systemic symptoms after dental implantation. This ca...Dental implants have spread worldwide in dentistry. The risks and complications reported are limited to local issues. However, in this case, a patient complained of systemic symptoms after dental implantation. This case report aims to demonstrate that systemic symptoms such as lumbago, shoulder stiffness, neck pain, hip joint pain, and facial pain improved after the removal of well-osseointegrated titanium implants. The results suggest that harmful electromagnetic waves received by implants affect body conditions;however, to date, the underlying mechanisms have not been identified. Therefore, further research is required.展开更多
Sub-gingival anaerobic pathogens can colonize an implant surface to compromise osseointegration of dental implants once the soft tissue seal around the neck of an implant is broken. In vitro evaluations of implant mat...Sub-gingival anaerobic pathogens can colonize an implant surface to compromise osseointegration of dental implants once the soft tissue seal around the neck of an implant is broken. In vitro evaluations of implant materials are usually done in monoculture studies involving either tissue integration or bacterial colonization. Co-culture models, in which tissue cells and bacteria battle simultaneously for estate on an implant surface, have been demonstrated to provide a better in vitro mimic of the clinical situation. Here we aim to compare the surface coverage by U2OS osteoblasts cells prior to and after challenge by two anaerobic sub-gingival pathogens in a co-culture model on differently modified titanium (Ti), titanium-zirconium (TiZr) alloys and zirconia surfaces. Monoculture studies with either U2OS osteoblasts or bacteria were also carried out and indicated significant differences in biofilm formation between the implant materials, but interactions with U2OS osteoblasts were favourable on all materials. Adhering U2OS osteoblasts cells, however, were significantly more displaced from differently modified Ti surfaces by challenging sub-gingival pathogens than from TiZr alloys and zirconia variants. Combined with previous work employing a co-culture model consisting of human gingival fibroblasts and supra-gingival oral bacteria, results point to a different material selection to stimulate the formation of a soft tissue seal as compared to preservation of osseointegration under the unsterile conditions of the oral cavity.展开更多
Objective:To assess the biomechanical properties of a new design configuration for zirconia dental implants. Methods: The new design has a cylindrical shape that is partially hollow and porous in the bottom, which per...Objective:To assess the biomechanical properties of a new design configuration for zirconia dental implants. Methods: The new design has a cylindrical shape that is partially hollow and porous in the bottom, which permits the implants to be locked into the alveolar bone over time. It also utilizes bioactive glass coatings to increase adhesion to surrounding bone structure. Samples of the new design were fabricated in the laboratory and their material strength, hardness, and fracture toughness were evaluated. In addition, biocompatibility of the new design was evaluated through testing in dogs. Results: Results of mechanical tests indicate that structural properties of the new design exceed the usual requirements for implants. Moreover, animal tests suggest that there is appreciable improvement in lock-in strength and osteointegration. Conclusion: The new design configuration is biomechanically feasible and further research is warranted to improve the design for human use.展开更多
AIM: To discuss important characteristics of the useof dental implants in posterior quadrants and the rehabilitation planning. METHODS: An electronic search of English articles was conducted on MEDLINE(PubM ed) from 1...AIM: To discuss important characteristics of the useof dental implants in posterior quadrants and the rehabilitation planning. METHODS: An electronic search of English articles was conducted on MEDLINE(PubM ed) from 1990 up to the period of March 2014. The key terms were dental implants and posterior jaws, dental implants/treatment planning and posterior maxilla, and dental implants/treatment planning and posterior mandible. No exclusion criteria were used for the initial search. Clinical trials, randomized and non randomized studies, classical and comparative studies, multicenter studies, in vitro and in vivo studies, case reports, longitudinal studies and reviews of the literature were included in this review. RESULTS: One hundred and fifty-two articles met the inclusion criteria of treatment planning of dental implants in posterior jaw and were read in their entirety. The selected articles were categorized with respect to their context on space for restoration, anatomic considerations(bone quantity and density), radiographic techniques, implant selection(number, position, diameter and surface), tilted and pterygoid implants, short implants, occlusal considerations, and success rates of implants placed in the posterior region. The results derived from the review process were described under several different topic headings to give readers a clear overview of the literature. In general, it was observed that the use of dental implants in posterior region requires a careful treatment plan. It is important that the practitioner has knowledge about the theme to evaluate the treatment parameters. CONCLUSION: The use of implants to restore the posterior arch presents many challenges and requires a detailed treatment planning.展开更多
The surface treatment is important for titanium and its alloys as promising candidates for dental implantation due to their bioinert surface.Titanium surface samples were modified using H2O2 solution at different time...The surface treatment is important for titanium and its alloys as promising candidates for dental implantation due to their bioinert surface.Titanium surface samples were modified using H2O2 solution at different times up to 72 h to boost their bioactivity.According to the results of the field emission scanning electron microscopy test,some nanostructures are formed on the surface of treated titanium samples and increased in size by increasing the time of treatment up to 24 h.After 24 h of application,the sharpness of nanostructures decreased and the micro-cracks and discontinuity in the coating surface increased.The results of the X-ray diffraction study and Raman spectroscopy revealed that anatase(TiO2)was formed on the surface of treated titanium samples.The peak intensity of Raman spectroscopy increased with an improvement in treatment time of up to 24 h and then decreased due to the discontinuity of the coating.Full wettability and ability to form apatite were reached at 6 h of treatment.It is clear that the treatment time has a significant effect on the surface treatment of titanium using the H2O2 solution.展开更多
The insertion torque of a dental implant is an important indicator for the primary stability of dental implants.Thus,the preoperative prediction for the insertion torque is crucial to improve the success rate of impla...The insertion torque of a dental implant is an important indicator for the primary stability of dental implants.Thus,the preoperative prediction for the insertion torque is crucial to improve the success rate of implantation surgery.In this present research,an alternative method for prediction of implant torque was proposed.First,the mechanical model for the insertion torque was established based on an oblique cutting process.In the proposed mechanical model,three factors,including bone quality,implant geometry and surgical methods were considered in terms of bone-quality coefficients,chip load and insertion speeds,respectively.Then,the defined bone-quality coefficients for cancellous bone with the computed tomography(CT)value of 235–245,345–355 and 415–425 Hu were obtained by a series of insertion experiments of IS and ITI implants.Finally,the insertion experiments of DIO implants were carried out to verify the accuracy of developed model.The predicted insertion torques calculated by the mechanical model were compared with those acquired by insertion experiments,with good agreement,the relative error being less than 15%.This method allows the insertion torque for different implant types to be quickly established and enhances prediction accuracy by considering the effects of implants’geometries and surgical methods.展开更多
The presence of insufficient bone volume affects the implant healing and success.The aim of this study was to evaluate osteogenic capacity of dental pulp stem cells(DPSCs) on micro-arc oxidation(MAO) titanium surface....The presence of insufficient bone volume affects the implant healing and success.The aim of this study was to evaluate osteogenic capacity of dental pulp stem cells(DPSCs) on micro-arc oxidation(MAO) titanium surface.DPSCs were challenged at MAO and smooth titanium surface separately for different durations,and the bone marrow mesenchymal stem cells(BMSCs) served as the positive controls.The osteogenic capacity of DPSCs on MAO titanium surface was assessed by using scanning electron microscopy,energy dispersive spectroscopy,biochemical tests and real-time quantitative PCR.Data showed that DPSCs differentiated into osteoblasts and expressed bone morphogenetic genes on MAO titanium surface.The results of this study revealed that DPSCs had good potential to generate mineralized tissue on MAO titanium plates.The differential potential of DPSCs may be regulated by MAO titanium surface.The osteogenesis potential of DPSCs on the MAO titanium was similar with BMSCs.展开更多
Overdenture as a treatment modality for both partially and fully edentulous patients is costeffective and less expensive. The purpose of the present study was to examine the newly fabricated attachments by comparing t...Overdenture as a treatment modality for both partially and fully edentulous patients is costeffective and less expensive. The purpose of the present study was to examine the newly fabricated attachments by comparing them with conventional O-ring attachment in vitro in terms of retention force and cyclic aging resistance. A total of 150 samples were prepared and divided into five groups according to the materials used(O-ring attachment, Deflex M10 XR, Deflex Classic SR, Deflex Acrilato FD, and flexible acrylic resin). The retention force of different attachments was measured by a mini dental implant after three subsequent aging(0, 63, and 126) cycles in the circumstances similar to the oral environment. The gap space between the head of the implant and the inner surface of the attachments was detected. Two-way analysis of variance(ANOVA) analysis with multiple comparisons test was applied for statistical analysis. The results showed that Deflex M10 XR had the highest retention force and the lowest gap space after cyclic aging; in addition, by comparing the relative force reduction, the lowest values were obtained in the O-ring attachment and the highest values in the flexible acrylic resin attachment. The retention force measured after cyclic aging for the Deflex M10 XR attachment was greatly improved when compared with the O-ring attachment and other types of attachment materials; in addition, the Deflex M10 XR attachment exhibited the minimum gap space between the inner surface and the mini dental implant head. In conclusion, Deflex M10 XR has the ability to withstand weathering conditions and retains its durable and retentive properties after aging when compared with other attachments.展开更多
[Objectives] To explore the flexural strength of 3D printed titanium bone bionic dental implants and provide a scientific basis for the clinical application of 3D printed porous bionic bone dental implants. [Methods] ...[Objectives] To explore the flexural strength of 3D printed titanium bone bionic dental implants and provide a scientific basis for the clinical application of 3D printed porous bionic bone dental implants. [Methods] The cone-beam CT( CBCT) image information of 20 premolars extracted by orthodontic requirement was collected,and a new porous bone bionic dental implant was produced using modeling software and 3D printer. The premolars were divided into two groups( A and B). The universal testing machine was used to test the flexural strength of the two groups and the difference in flexural strength between the two groups was compared through statistics. [Results]Twenty 3D printed porous titanium bone bionic implants were accurately produced; the morphology of group A and group B were extremely similar to each other; the average flexural strength of group A was 2 767. 92 N,while the average flexural strength of group B was 778. 77 N,showing that the average flexural strength of group A was significantly higher than that of group B,and the difference was statistically significant( P < 0. 05).[Conclusions]The personalized porous structure root implants produced by 3D printing technology are very similar to the target tooth morphology,and show high accuracy and small error of production. Besides,the flexural strength of 3D printed personalized porous structure root implants can fully meet the requirements of the maximum occlusal force for dental implant restoration. It is expected to provide a scientific basis for clinical application of 3 D printed porous bionic bone tooth implants.展开更多
<b><span style="font-family:Verdana;">Introduction:</span></b><span style="font-family:Verdana;"> I Do Biotech’s implants were developed starting in 2014. Since then,...<b><span style="font-family:Verdana;">Introduction:</span></b><span style="font-family:Verdana;"> I Do Biotech’s implants were developed starting in 2014. Since then, they obtained GMP and KFDA licenses for distribution in 2015. The main objective of this paper is to determine the survival rate of I Do Biotech implants five years after the first surgery.</span><span style="font-family:Verdana;"> </span><b><span style="font-family:Verdana;">Material and Methods:</span></b><span style="font-family:Verdana;"> 1000 implants were used on 480 prosthes</span><span style="font-family:Verdana;">e</span><span style="font-family:Verdana;">s across 10 clinics on 320 healthy, non-smoker and non-diabetic patients, chosen at random, of which 160 are male and 160 female, all in the age range of 30 to 50 years old. The failure rate was studied related to the patient’s gender, the length and diameter of the implant, anatomical location, the percentage of peri-implantitis, prosthodontic failures and the patient’s quality of life.</span><span style="font-family:Verdana;"> </span><b><span style="font-family:Verdana;">Discussion:</span></b><span style="font-family:Verdana;"> The results obtained are similar to those of Van Steenberghe D. Dieter-Busenlechner, E. Serrano Catauria and far superior to those of Sáenz Guzmán. Failure rates vary greatly from study to study due to the heterogeneity of the samples in the other research papers. </span><b><span style="font-family:Verdana;">Conclusion:</span></b><span style="font-family:Verdana;"> The overall implant failure rate at 5 years is 1.7%. The factors affecting significantly the survival rate are: the implant diameter, its length and the anatomic area. Failure ratios increase significantly when the diameter or the length of the implant decrease</span><span style="font-family:Verdana;">s</span><span style="font-family:Verdana;">, and when they are placed in the posterior maxilla (up to 4.3%).</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">The rate of peri-implantitis is 5.1%. The prosthodontic failure rate is 2.91%. The improvement in quality of life and satisfaction increases with the years.</span>展开更多
We report a 53 year-old male who suffered 18 months of foul-smelling green nasal discharge, halitosis and a heavy discomfort behind his right eye. The symptoms were consistent with chronic rhinosinusitis. The patient ...We report a 53 year-old male who suffered 18 months of foul-smelling green nasal discharge, halitosis and a heavy discomfort behind his right eye. The symptoms were consistent with chronic rhinosinusitis. The patient had a right upper molar dental extraction shortly before the onset of symptoms. A radio-opaque foreign body was noted in his right maxillary sinus on CT. During surgery a tooth resembling foreign body was removed. The patient's symptoms completely resolved within weeks of the removal.展开更多
文摘With the continuous advancement of technology,the application of 3D printing technology in the field of dental medicine is becoming increasingly widespread.This article aims to explore the current applications and future potential of 3D printing technology in dental medicine and to analyze its benefits and challenges.It first introduces the current state of 3D printing technology in dental implants,crowns,bridges,orthodontics,and maxillofacial surgery.It then discusses the potential applications of 3D printing technology in oral tissue engineering,drug delivery systems,personalized dental prosthetics,and surgical planning.Finally,it analyzes the benefits of 3D printing technology in dental medicine,such as improving treatment accuracy and patient comfort,and shortening treatment times,while also highlighting the challenges faced,such as costs,material choices,and technical limitations.This article aims to provide a reference for professionals in the field of dental medicine and to promote the further application and development of 3D printing technology in this area.
文摘Objective: To assess the actual practical attitude and knowledge of dental implants among senior dental students and general dentists graduated from some Saudi and Non-Saudi dental schools. Methods: A total of 300 senior dental students and general dentists participated in the study. Hard copies of the self-designed, multiple-choice questionnaires were distributed to all participants. The questionnaire consisted of 31 questions in five parts. Data were collected and analyzed using Chi-square test and t-test, where p Results: There is a statistically significant relationship between the participants’ answers, and their dental schools. Participants’ general knowledge, training, and teaching of dental implants, as well as information about restorations retained for the dental implants, were higher among participants from Saudi dental schools than participants from non-Saudi dental schools, while the information about dental implants was higher among participants from non-Saudi dental schools than participants from Saudi dental schools. Conclusion: We conclude that the actual practical attitude and knowledge of dental implants among participants in the current study was insufficient. Therefore, dental implant education in the undergraduate curricula of dental schools surveyed should be updated to include teaching, laboratory training, and preclinical and clinical training.
文摘BACKGROUND Lateral window approach for sinus floor lift is commonly used for vertical bone augmentation in cases when the residual bone height is less than 5 mm.However,managing cases becomes more challenging when a maxillary sinus pseudocyst is present or when there is insufficient bone width.In this case,we utilized the bone window prepared during the lateral window sinus lift as a shell for horizontal bone augmentation.This allowed for simultaneous horizontal and vertical bone augmentation immediately after the removal of the maxillary sinus pseudocyst.CASE SUMMARY A 28-year-old female presented to our clinic with the chief complaint of missing upper left posterior teeth.Intraoral examination showed a horizontal deficiency of the alveolar ridge contour.The height of the alveolar bone was approximately 3.6 mm on cone beam computed tomography(CBCT).And a typical well-defined'dome-shaped'lesion in maxillary sinus was observed on CBCT imaging.The lateral bony window was prepared using a piezo-ultrasonic device,then the bony window was fixed to the buccal side of the 26 alveolar ridge using a titanium screw with a length of 10 mm and a diameter of 1.5 mm.The space between the bony window and the alveolar ridge was filled with Bio-Oss,covered with a Bio-Gide collagen membrane,and subsequently sutured.Nine months later,the patient’s bone width increased from 4.8 to 10.5 mm,and the bone height increased from 3.6 to 15.6 mm.Subsequently,a Straumann^(■)4.1 mm×10 mm implant was placed.The final all-ceramic crown restoration was completed four months later,and both clinical and radiographic examinations showed that the implant was successful,and the patient was satisfied with the results.CONCLUSION The bone block harvested from the lateral window sinus lift can be used for simultaneous horizontal bone augmentation acting as a shell for good two-dimensional bone augmentation.
基金the Review Committee of General Hospital of Central Theater Command(Approval No.05901).
文摘BACKGROUND Tooth defects can cause elongation of occlusal teeth,leading to insufficient repair space.The combination of dental implant restoration and orthodontic treatment of oblique adjacent teeth has a significant therapeutic effect.AIM To explore clinical efficacy,bone density,and follow-up of implant and orthodontic treatment for patients with inclined adjacent teeth.METHODS In total,98 patients with oblique adjacent teeth were randomly assigned to implant restoration combined with orthodontic treatment(group A,n=49)or to receive implant restoration alone(group B,n=49).Changes in alveolar ridge bone density and apical bone density were observed before and after treatment in the two groups.Changes in chewing function and language function were compared between the two groups of patients.Follow-up lasted for 12 mo after repair to observe any adverse reactions in the oral cavity.RESULTS The clinical effective rates of group A and group B were 97.96%and 85.71%,respectively,with group A having a higher clinical effective rate than group B.After treatment,the bone density of the alveolar ridge and apical bone in both groups decreased compared to before treatment,while the chewing and language functions improved.The changes in various indicators in group A were more significant.After treatment,the satisfaction rate of group A(97.96%)was higher than that of group B(79.59%).The incidence of adverse reactions in group A(2.04%)was lower than that in group B(24.49%).CONCLUSION The amalgamation of implant restoration and orthodontic treatment for adjacent tilted teeth demonstrates notable clinical efficacy,diminishes alveolar bone resorption,and fosters patient functional rehabilitation while exhibiting negligible adverse reactions.
文摘Background: Four factors determine the quality of an implantology kit: 1) Heat generated by the drills;2) Morphology of the osteotomy according to the diameter of the implant;3) Efficiency of collecting autologous bone;and 4) Osteotomy execution time. Materials and Methods: This article examines the heat produced by drills during osteotomy, focusing on the effect of the following factors: drilling technique;volume of autologous bone harvested;drilling time;implant primary stability;and the percentage of osseointegrated implants after primary healing. Discussion: The four factors mentioned above are analyzed based on the data obtained for sequential, biological, and One Drill milling techniques. Conclusions: 1) One Drill is the fastest technique for performing the osteotomy;2) All techniques stay within the biological temperature range of living bone, with the lowest increase in temperature achieved using One Drill with irrigation;3) The bone harvested showed no statistically significant differences between biological milling and the One Drill technique, both far superior to the sequential technique;and 4) There is no statistically significant difference in the number of osseointegrated implants among the three techniques analyzed.
基金supported by grants from the National Natural Science Foundation of China(NSFC 81371173)the State Key Laboratory of Oral Diseases(SKLOD201704)+1 种基金the International Team for Implantology(Grant No.975_2014,Basel,Switzerland)the National Key R&D Program of China during the thirteenth Five-Year Plan(2016YFC1102700)
文摘Chronic kidney disease (CKD) is a worldwide public health problem that is growing in prevalence and is associated with severe complications. During the progression of the disease, a majority of CKD patients suffer oral complications. Dental implants are currently the most reliable and successful treatment for missing teeth. However, due to complications of CKD such as infections, bone lesions, bleeding risks, and altered drug metabolism, dental implant treatment for renal failure patients on dialysis is more challenging. In this review, we have summarized the characteristics of CKD and previous publications regarding dental treatments for renal failure patients. In addition, we discuss our recent research results and clinical experience in order to provide dental implant practitioners with a clinical guideline for dental implant treatment for renal failure patients undergoing hemodialysis.
基金Supported by Sao Paulo Research Foundation,FAPESP,No.2008/06972-6The National Council for Scientific and Technological Development,CNPq Nos.579157/2008-3,302768/2009-2 and 473282/2007-0+1 种基金Pesq-Doc scholarship to Dr.Shibli from University of GuaruhosScholarship to Dr.Giro from University of Guarulhos
文摘AIM: To assess the failure and bone-to-implant contact rate of dental implants placed on osteoporotic subjects. METHODS: Extensive examination strategies were created to classify studies for this systematic review. MEDLINE(via Pub Med) and EMBASE database were examined for studies in English up to and including May 2014. The examination presented a combination of the MeS H words described as follow: "osteoporosis" or "osteopenia" or "estrogen deficiency" AND "implant" or "dental implant" or "osseointegration". Assessment of clinical and/or histological peri-implant conditions in osteoporosis subjects treated with titanium dental implants. The examination included a combination of the MeS H terms described as follow: "osteoporosis" or "osteopenia" or "estrogen deficiency" AND "implant" or "dental implant" or "osseointegration".RESULTS: Of 943 potentially eligible articles, 12 were included in the study. A total of 133 subjects with osteoporosis, 73 subjects diagnosed with osteopenia and 708 healthy subjects were assessed in this systematic review. In these subjects were installed 367, 205, 2981 dental implants in osteoporotic, osteopenic and healthy subjects, respectively. The failure rate of dental implant was 10.9% in osteoporotic subjects, 8.29% in osteopenic and 11.43% in healthy ones. Bone-to-implant contact obtained from retrieved implants ranged between 49.96% to 47.84%, for osteoporosis and non-osteoporotic subjects. CONCLUSION: Osteoporotic subjects presented higher rates of implant loss, however, there is a lower evidence to strengthen or refute the hypothesis that osteoporosis may have detrimental effects on bone healing. Consequently, final conclusions regarding the effect of osteoporosis in dental implant therapy cannot be made at this time. There are no randomized clinical trial accessible for evaluation and the retrospectivenature of the evaluated studies shall be taken in account when interpreting this study.
基金the support of the National Natural Science Foundation of China (Nos. 81170996, 81070867, and 81100777)Sichuan Province Science and Technology Innovation Team Program (2011JTD0006)
文摘Micromotion and fretting damages at the dental implant/bone interface are neglected for the limitation of check methods, but it is particularly important for the initial success of osseointegration and the life time of dental implant. This review article describes the scientific documentation of micromotion and fretting damages on the dental implant/bone interface. The fretting amplitude is less than 30 l^m in vitroand the damage in the interface is acceptable. While in vivo, the micromotion's effect is the combination of damage in tissue level and the real biological reaction.
基金Natural Science Foundation of Guangdong Province(Grant No.2021A1515011208)National Natural Scientific Foundation of China(Grant No.81671788)+1 种基金National Science Foundation for Young Scientists of China(Grant No.81701662)The Joint Found of National Science Foundation of China and GuangDong Provincial Government(Grant No.U1301258).
文摘At present,dental implant surgery mainly relies on the clinical experience of the doctor and the assistance of preoperative medical imaging.However,there are some problems in dental implant surgery,such as narrow space,sight obstruction,inaccurate positioning,and high requirements of doctors’proficiency.Therefore,a dental implant robot system(DIRS)guided by optical navigation is developed in this study,with an x-shaped tool and an irregular pentagonal tracer are designed for spatial registration and needle tip positioning strategy respectively.The coordinate system of each unit in DIRS is unified through system calibration,spatial registration,and needle tip positioning strategy.Then the surgical path is planned on the computed tomography(CT)images in the navigation software before operation.The automatic positioning method and the auxiliary positioning method can be used in the operation to achieve accurate positioning and assist doctors to complete the operation.The errors of spatial registration,needle tip positioning strategy,and the overall accuracy of the system were evaluated respectively,and the results showed that they all met the needs of clinical surgery.This study preliminarily verified the feasibility of the precise positioning method for dental surgery robots and provided certain ideas for subsequent related research.
文摘Dental implants have spread worldwide in dentistry. The risks and complications reported are limited to local issues. However, in this case, a patient complained of systemic symptoms after dental implantation. This case report aims to demonstrate that systemic symptoms such as lumbago, shoulder stiffness, neck pain, hip joint pain, and facial pain improved after the removal of well-osseointegrated titanium implants. The results suggest that harmful electromagnetic waves received by implants affect body conditions;however, to date, the underlying mechanisms have not been identified. Therefore, further research is required.
文摘Sub-gingival anaerobic pathogens can colonize an implant surface to compromise osseointegration of dental implants once the soft tissue seal around the neck of an implant is broken. In vitro evaluations of implant materials are usually done in monoculture studies involving either tissue integration or bacterial colonization. Co-culture models, in which tissue cells and bacteria battle simultaneously for estate on an implant surface, have been demonstrated to provide a better in vitro mimic of the clinical situation. Here we aim to compare the surface coverage by U2OS osteoblasts cells prior to and after challenge by two anaerobic sub-gingival pathogens in a co-culture model on differently modified titanium (Ti), titanium-zirconium (TiZr) alloys and zirconia surfaces. Monoculture studies with either U2OS osteoblasts or bacteria were also carried out and indicated significant differences in biofilm formation between the implant materials, but interactions with U2OS osteoblasts were favourable on all materials. Adhering U2OS osteoblasts cells, however, were significantly more displaced from differently modified Ti surfaces by challenging sub-gingival pathogens than from TiZr alloys and zirconia variants. Combined with previous work employing a co-culture model consisting of human gingival fibroblasts and supra-gingival oral bacteria, results point to a different material selection to stimulate the formation of a soft tissue seal as compared to preservation of osseointegration under the unsterile conditions of the oral cavity.
文摘Objective:To assess the biomechanical properties of a new design configuration for zirconia dental implants. Methods: The new design has a cylindrical shape that is partially hollow and porous in the bottom, which permits the implants to be locked into the alveolar bone over time. It also utilizes bioactive glass coatings to increase adhesion to surrounding bone structure. Samples of the new design were fabricated in the laboratory and their material strength, hardness, and fracture toughness were evaluated. In addition, biocompatibility of the new design was evaluated through testing in dogs. Results: Results of mechanical tests indicate that structural properties of the new design exceed the usual requirements for implants. Moreover, animal tests suggest that there is appreciable improvement in lock-in strength and osteointegration. Conclusion: The new design configuration is biomechanically feasible and further research is warranted to improve the design for human use.
文摘AIM: To discuss important characteristics of the useof dental implants in posterior quadrants and the rehabilitation planning. METHODS: An electronic search of English articles was conducted on MEDLINE(PubM ed) from 1990 up to the period of March 2014. The key terms were dental implants and posterior jaws, dental implants/treatment planning and posterior maxilla, and dental implants/treatment planning and posterior mandible. No exclusion criteria were used for the initial search. Clinical trials, randomized and non randomized studies, classical and comparative studies, multicenter studies, in vitro and in vivo studies, case reports, longitudinal studies and reviews of the literature were included in this review. RESULTS: One hundred and fifty-two articles met the inclusion criteria of treatment planning of dental implants in posterior jaw and were read in their entirety. The selected articles were categorized with respect to their context on space for restoration, anatomic considerations(bone quantity and density), radiographic techniques, implant selection(number, position, diameter and surface), tilted and pterygoid implants, short implants, occlusal considerations, and success rates of implants placed in the posterior region. The results derived from the review process were described under several different topic headings to give readers a clear overview of the literature. In general, it was observed that the use of dental implants in posterior region requires a careful treatment plan. It is important that the practitioner has knowledge about the theme to evaluate the treatment parameters. CONCLUSION: The use of implants to restore the posterior arch presents many challenges and requires a detailed treatment planning.
基金This work was financially supported by Grant-in-Aid(Nos.19K10250 and 18K09686)from Scientific Research of the Japan Society for the Promotion of Science(JSPS).
文摘The surface treatment is important for titanium and its alloys as promising candidates for dental implantation due to their bioinert surface.Titanium surface samples were modified using H2O2 solution at different times up to 72 h to boost their bioactivity.According to the results of the field emission scanning electron microscopy test,some nanostructures are formed on the surface of treated titanium samples and increased in size by increasing the time of treatment up to 24 h.After 24 h of application,the sharpness of nanostructures decreased and the micro-cracks and discontinuity in the coating surface increased.The results of the X-ray diffraction study and Raman spectroscopy revealed that anatase(TiO2)was formed on the surface of treated titanium samples.The peak intensity of Raman spectroscopy increased with an improvement in treatment time of up to 24 h and then decreased due to the discontinuity of the coating.Full wettability and ability to form apatite were reached at 6 h of treatment.It is clear that the treatment time has a significant effect on the surface treatment of titanium using the H2O2 solution.
基金Major Research&Development Program of Shandong Province(Grant No.2015GGX103043)Taishan Scholars Program of Shandong Province(Grant No.ts201712002).
文摘The insertion torque of a dental implant is an important indicator for the primary stability of dental implants.Thus,the preoperative prediction for the insertion torque is crucial to improve the success rate of implantation surgery.In this present research,an alternative method for prediction of implant torque was proposed.First,the mechanical model for the insertion torque was established based on an oblique cutting process.In the proposed mechanical model,three factors,including bone quality,implant geometry and surgical methods were considered in terms of bone-quality coefficients,chip load and insertion speeds,respectively.Then,the defined bone-quality coefficients for cancellous bone with the computed tomography(CT)value of 235–245,345–355 and 415–425 Hu were obtained by a series of insertion experiments of IS and ITI implants.Finally,the insertion experiments of DIO implants were carried out to verify the accuracy of developed model.The predicted insertion torques calculated by the mechanical model were compared with those acquired by insertion experiments,with good agreement,the relative error being less than 15%.This method allows the insertion torque for different implant types to be quickly established and enhances prediction accuracy by considering the effects of implants’geometries and surgical methods.
基金supported by the Innovation Fund of Huazhong University of Science and Technology,Wuhan,P.R. China (No.2011JC018)
文摘The presence of insufficient bone volume affects the implant healing and success.The aim of this study was to evaluate osteogenic capacity of dental pulp stem cells(DPSCs) on micro-arc oxidation(MAO) titanium surface.DPSCs were challenged at MAO and smooth titanium surface separately for different durations,and the bone marrow mesenchymal stem cells(BMSCs) served as the positive controls.The osteogenic capacity of DPSCs on MAO titanium surface was assessed by using scanning electron microscopy,energy dispersive spectroscopy,biochemical tests and real-time quantitative PCR.Data showed that DPSCs differentiated into osteoblasts and expressed bone morphogenetic genes on MAO titanium surface.The results of this study revealed that DPSCs had good potential to generate mineralized tissue on MAO titanium plates.The differential potential of DPSCs may be regulated by MAO titanium surface.The osteogenesis potential of DPSCs on the MAO titanium was similar with BMSCs.
文摘Overdenture as a treatment modality for both partially and fully edentulous patients is costeffective and less expensive. The purpose of the present study was to examine the newly fabricated attachments by comparing them with conventional O-ring attachment in vitro in terms of retention force and cyclic aging resistance. A total of 150 samples were prepared and divided into five groups according to the materials used(O-ring attachment, Deflex M10 XR, Deflex Classic SR, Deflex Acrilato FD, and flexible acrylic resin). The retention force of different attachments was measured by a mini dental implant after three subsequent aging(0, 63, and 126) cycles in the circumstances similar to the oral environment. The gap space between the head of the implant and the inner surface of the attachments was detected. Two-way analysis of variance(ANOVA) analysis with multiple comparisons test was applied for statistical analysis. The results showed that Deflex M10 XR had the highest retention force and the lowest gap space after cyclic aging; in addition, by comparing the relative force reduction, the lowest values were obtained in the O-ring attachment and the highest values in the flexible acrylic resin attachment. The retention force measured after cyclic aging for the Deflex M10 XR attachment was greatly improved when compared with the O-ring attachment and other types of attachment materials; in addition, the Deflex M10 XR attachment exhibited the minimum gap space between the inner surface and the mini dental implant head. In conclusion, Deflex M10 XR has the ability to withstand weathering conditions and retains its durable and retentive properties after aging when compared with other attachments.
文摘[Objectives] To explore the flexural strength of 3D printed titanium bone bionic dental implants and provide a scientific basis for the clinical application of 3D printed porous bionic bone dental implants. [Methods] The cone-beam CT( CBCT) image information of 20 premolars extracted by orthodontic requirement was collected,and a new porous bone bionic dental implant was produced using modeling software and 3D printer. The premolars were divided into two groups( A and B). The universal testing machine was used to test the flexural strength of the two groups and the difference in flexural strength between the two groups was compared through statistics. [Results]Twenty 3D printed porous titanium bone bionic implants were accurately produced; the morphology of group A and group B were extremely similar to each other; the average flexural strength of group A was 2 767. 92 N,while the average flexural strength of group B was 778. 77 N,showing that the average flexural strength of group A was significantly higher than that of group B,and the difference was statistically significant( P < 0. 05).[Conclusions]The personalized porous structure root implants produced by 3D printing technology are very similar to the target tooth morphology,and show high accuracy and small error of production. Besides,the flexural strength of 3D printed personalized porous structure root implants can fully meet the requirements of the maximum occlusal force for dental implant restoration. It is expected to provide a scientific basis for clinical application of 3 D printed porous bionic bone tooth implants.
文摘<b><span style="font-family:Verdana;">Introduction:</span></b><span style="font-family:Verdana;"> I Do Biotech’s implants were developed starting in 2014. Since then, they obtained GMP and KFDA licenses for distribution in 2015. The main objective of this paper is to determine the survival rate of I Do Biotech implants five years after the first surgery.</span><span style="font-family:Verdana;"> </span><b><span style="font-family:Verdana;">Material and Methods:</span></b><span style="font-family:Verdana;"> 1000 implants were used on 480 prosthes</span><span style="font-family:Verdana;">e</span><span style="font-family:Verdana;">s across 10 clinics on 320 healthy, non-smoker and non-diabetic patients, chosen at random, of which 160 are male and 160 female, all in the age range of 30 to 50 years old. The failure rate was studied related to the patient’s gender, the length and diameter of the implant, anatomical location, the percentage of peri-implantitis, prosthodontic failures and the patient’s quality of life.</span><span style="font-family:Verdana;"> </span><b><span style="font-family:Verdana;">Discussion:</span></b><span style="font-family:Verdana;"> The results obtained are similar to those of Van Steenberghe D. Dieter-Busenlechner, E. Serrano Catauria and far superior to those of Sáenz Guzmán. Failure rates vary greatly from study to study due to the heterogeneity of the samples in the other research papers. </span><b><span style="font-family:Verdana;">Conclusion:</span></b><span style="font-family:Verdana;"> The overall implant failure rate at 5 years is 1.7%. The factors affecting significantly the survival rate are: the implant diameter, its length and the anatomic area. Failure ratios increase significantly when the diameter or the length of the implant decrease</span><span style="font-family:Verdana;">s</span><span style="font-family:Verdana;">, and when they are placed in the posterior maxilla (up to 4.3%).</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">The rate of peri-implantitis is 5.1%. The prosthodontic failure rate is 2.91%. The improvement in quality of life and satisfaction increases with the years.</span>
文摘We report a 53 year-old male who suffered 18 months of foul-smelling green nasal discharge, halitosis and a heavy discomfort behind his right eye. The symptoms were consistent with chronic rhinosinusitis. The patient had a right upper molar dental extraction shortly before the onset of symptoms. A radio-opaque foreign body was noted in his right maxillary sinus on CT. During surgery a tooth resembling foreign body was removed. The patient's symptoms completely resolved within weeks of the removal.