期刊文献+
共找到4,370篇文章
< 1 2 219 >
每页显示 20 50 100
Complicated calcified alloplastic implants in the nasal dorsum:A clinical analysis
1
作者 Yong-Seon Hwang Taek-Kyun Kim +2 位作者 Dong-Jun Yang Si-Hyong Jang Da-Woon Lee 《World Journal of Clinical Cases》 SCIE 2024年第18期3351-3359,共9页
BACKGROUND In rhinoplasty,calcification around silicone implants is frequently observed in the tip dorsum(TD)area.Additionally,based on a review of various literature,it is presumed that calcification in silicone impl... BACKGROUND In rhinoplasty,calcification around silicone implants is frequently observed in the tip dorsum(TD)area.Additionally,based on a review of various literature,it is presumed that calcification in silicone implants occurs due to both inflammatory chemical reactions and physical friction against the tissue.The calcification of nasal silicone implants not only results in the functional loss of the implants,but also leads to material deformation.However,there is a lack of research on calcification of nasal silicone implants in the current literature.AIM To elucidate various clinical characteristics of calcification around nasal silicone implants,using histological and radiological analysis.METHODS This study analyzed data from 16 patients of calcified nasal implants,who underwent revision rhinoplasty for various reasons after undergoing augmentation rhinoplasty with silicone implants.The collected data included information on implant duration,implant types,location of calcification,presence of inflammatory reactions,and computed tomography(CT)scans.RESULTS The most common location of calcification,as visually analyzed,was in the TD area,accounting for 56%.Additionally,the analysis of CT scans revealed a trend of increasing Hounsfield Unit values for calcification with the duration of implantation,although this trend was not statistically significant(P=0.139).CONCLUSION Our study shows that reducing the frequency of calcification may be achievable by using softer silicone implants and by minimizing the damage to perioperative tissues. 展开更多
关键词 Silicone implants RHINOPLASTY CALCIFICATION complicATION Hounsfield unit
下载PDF
Long-term complications of the transmeatal approach (Open Transcanal) in cochlear implants: A follow-up study 被引量:1
2
作者 Hesham Saleh Almofada Nasser KAlmutairi Michael Steven Timms 《Journal of Otology》 CSCD 2023年第1期33-37,共5页
Objective: Multiple alternative approaches of cochlear implant surgery have been described, such as the suprameatal approach, transcanal approach, transmeatal approach and middle cranial fossa approach.Transmeatal(ope... Objective: Multiple alternative approaches of cochlear implant surgery have been described, such as the suprameatal approach, transcanal approach, transmeatal approach and middle cranial fossa approach.Transmeatal(open trnascanal) approach has not been adapted since first described in the clinical field.we aimed to assess the long-term complications of the transmeatal approach in a series of 131 patients at our center between 2004 and 2008.Methods: This study was a retrospective case series of all patients who underwent cochlear implants with the transmeatal(open transcanal) approach from May 2004 to December 2008 at King Faisal Specialist and Research Hospital(Riyadh, Saudi Arabia), which were conducted by the same surgeon.Results: Complications were observed often with various combinations-recurrent otitis externa, posterior tympanic membrane perforation, electrode extrusion, cholesteatoma, and chronic mastoiditis. The overall long-term complication rate was 16%(21/131). The gap between the implantation and the diagnosis of a complication ranged from <1 year to 11 years. Major complications were as follows:cholesteatoma in 5(3.8%) patients, extrusion of the electrode in 5(3.8%) patients, and tympanic membrane perforation or deep retractions in 5(3.8%) patients. Minor complications were as follows: recurrent mastoiditis with/without concomitant temporary facial nerve palsy in 4(3%) patients, recurrent otitis externa infections in 7(5%) patients, and weakness of the posterior canal wall in 1 patient.Conclusion: The transmeatal approach posed an high rate of complications on long-term follow-up such as cholestetoma formation, extrusion of electrode or perielectrode reaction formation to tympanic membrane and external auditory canal. 展开更多
关键词 Cochlear implant Transmeatal approach Open transcanal approach Surgical complication
下载PDF
Actual Practical Attitude and Knowledge of Dental Implants among Senior Dental Students and General Dentists Graduated from Some Saudi and Non-Saudi Dental Schools
3
作者 Mohammed M. A. Abdullah Al-Abdaly Sami Yahya Alamri +1 位作者 Ghadeer Mohammed Mohammed Al-Abdaly Ayed Abdulrahman Abdullah 《International Journal of Clinical Medicine》 CAS 2023年第1期1-19,共19页
Objective: To assess the actual practical attitude and knowledge of dental implants among senior dental students and general dentists graduated from some Saudi and Non-Saudi dental schools. Methods: A total of 300 sen... Objective: To assess the actual practical attitude and knowledge of dental implants among senior dental students and general dentists graduated from some Saudi and Non-Saudi dental schools. Methods: A total of 300 senior dental students and general dentists participated in the study. Hard copies of the self-designed, multiple-choice questionnaires were distributed to all participants. The questionnaire consisted of 31 questions in five parts. Data were collected and analyzed using Chi-square test and t-test, where p Results: There is a statistically significant relationship between the participants’ answers, and their dental schools. Participants’ general knowledge, training, and teaching of dental implants, as well as information about restorations retained for the dental implants, were higher among participants from Saudi dental schools than participants from non-Saudi dental schools, while the information about dental implants was higher among participants from non-Saudi dental schools than participants from Saudi dental schools. Conclusion: We conclude that the actual practical attitude and knowledge of dental implants among participants in the current study was insufficient. Therefore, dental implant education in the undergraduate curricula of dental schools surveyed should be updated to include teaching, laboratory training, and preclinical and clinical training. 展开更多
关键词 KNOWLEDGE dental implants dental Schools Non-Saudi Practical Attitude SAUDI
下载PDF
After cochlear implantation: Complications related to flap around implants 被引量:6
4
作者 Feifei Qin Wen Li +2 位作者 Jianxin Qiu Li Zhang Mei Zhong 《Journal of Otology》 CSCD 2016年第4期-,共4页
Objective: To report complications related to flap around implants after cochlear implantation, possible causes of such complications and treatments. Methods and material:We performed a retrospective analysis of child... Objective: To report complications related to flap around implants after cochlear implantation, possible causes of such complications and treatments. Methods and material:We performed a retrospective analysis of children in whom complications related to flap around implants occurred after undergoing cochlear implantation in our department from 2005 to 2016. Results:Complications among 1500 cochlear implantation (CI) recipients by the same surgeon included hematoma (n ? 20) and seroma around implants (n ? 15), of which most (n ? 10) recovered in 2 weeks after effective drainage, utility of antibiotics and pressure dressing, but 5 developed flap necrosis and had to undergo contralateral re-implantation. Four patients developed abscess around implants, of whom 2 recovered after 2 weeks of drainage, gentamicin irrigation and use of antibiotics, but 2 patients ended up with flap necrosis and had to receive contralateral reimplantation. Conclusions: Immediate drainage, pressure dressing and antibiotics can be used to effectively control seroma around implants. For seroma lasting for more than two weeks without improvement, surgical drainage may be need. 展开更多
关键词 Cochlear implant complications Flap-related problem
下载PDF
Impact of osteoporosis in dental implants:A systematic review 被引量:11
5
作者 Gabriela Giro Leandro Chambrone +6 位作者 Abrao Goldstein Jose Augusto Rodrigues Elton Zenóbio Magda Feres Luciene Cristina Figueiredo Alessandra Cassoni Jamil Awad Shibli 《World Journal of Orthopedics》 2015年第2期311-315,共5页
AIM: To assess the failure and bone-to-implant contact rate of dental implants placed on osteoporotic subjects. METHODS: Extensive examination strategies were created to classify studies for this systematic review. ME... AIM: To assess the failure and bone-to-implant contact rate of dental implants placed on osteoporotic subjects. METHODS: Extensive examination strategies were created to classify studies for this systematic review. MEDLINE(via Pub Med) and EMBASE database were examined for studies in English up to and including May 2014. The examination presented a combination of the MeS H words described as follow: "osteoporosis" or "osteopenia" or "estrogen deficiency" AND "implant" or "dental implant" or "osseointegration". Assessment of clinical and/or histological peri-implant conditions in osteoporosis subjects treated with titanium dental implants. The examination included a combination of the MeS H terms described as follow: "osteoporosis" or "osteopenia" or "estrogen deficiency" AND "implant" or "dental implant" or "osseointegration".RESULTS: Of 943 potentially eligible articles, 12 were included in the study. A total of 133 subjects with osteoporosis, 73 subjects diagnosed with osteopenia and 708 healthy subjects were assessed in this systematic review. In these subjects were installed 367, 205, 2981 dental implants in osteoporotic, osteopenic and healthy subjects, respectively. The failure rate of dental implant was 10.9% in osteoporotic subjects, 8.29% in osteopenic and 11.43% in healthy ones. Bone-to-implant contact obtained from retrieved implants ranged between 49.96% to 47.84%, for osteoporosis and non-osteoporotic subjects. CONCLUSION: Osteoporotic subjects presented higher rates of implant loss, however, there is a lower evidence to strengthen or refute the hypothesis that osteoporosis may have detrimental effects on bone healing. Consequently, final conclusions regarding the effect of osteoporosis in dental implant therapy cannot be made at this time. There are no randomized clinical trial accessible for evaluation and the retrospectivenature of the evaluated studies shall be taken in account when interpreting this study. 展开更多
关键词 dental implants OSTEOPOROSIS FAILURES OSTEOPENIA OSSEOINTEGRATION
下载PDF
Development of Niobium Oxide Coatings on Sand-Blasted Titanium Alloy Dental Implants 被引量:2
6
作者 Allen C. Mackey Robert L. Karlinsey +2 位作者 Tien-Mien G. Chu Meoghan MacPherson Daniel L. Alge 《Materials Sciences and Applications》 2012年第5期301-305,共5页
The purpose of this study was to use scanning electron microscopy (SEM) evaluation to determine the optimal anodizetion conditions needed to generate niobium oxide coatings on titanium alloy dental implant screws. San... The purpose of this study was to use scanning electron microscopy (SEM) evaluation to determine the optimal anodizetion conditions needed to generate niobium oxide coatings on titanium alloy dental implant screws. Sand-blasted titanium alloy dental implants were anodized in dilute hydrofluoric acid (HF(aq)) solution using a Sorensen DLM 300-2 power supply. The HF concentration and anodization time were varied and the resulting implant surfaces were evaluated using a Jeol JSM-5310LV Scanning Electron Microscope to determine the ideal anodization conditions. While HF is necessary to facilitate oxide growth, increasing concentrations resulted in proportionate increases in coating delamination. In a similar manner, a minimum anodization time of 1 hour was necessary for oxide growth but longer times produced more delamination especially at higher HF(aq) concentrations. SEM imaging showed that implants anodized for 1 hour in a 0.1% HF(aq) aqueous solution had the best results. Anodization can be used to generate niobium oxide coatings on sand-blasted Ti alloy dental implants by balancing the competing factors of oxide growth and coating delamination. It is believed that these oxide coatings have the potential to improve osseointegration relative to untreated dental implants when evaluated in an in vivo study. 展开更多
关键词 Anodization NIOBIUM Oxide dental implant Scanning Electron Microscopy
下载PDF
Posterior partially edentulous jaws, planning a rehabilitation with dental implants 被引量:6
7
作者 Douglas R Monteiro Emily V F Silva +2 位作者 Eduardo P Pellizzer Osvaldo Magro Filho Marcelo C Goiato 《World Journal of Clinical Cases》 2015年第1期65-76,共12页
AIM: To discuss important characteristics of the useof dental implants in posterior quadrants and the rehabilitation planning. METHODS: An electronic search of English articles was conducted on MEDLINE(PubM ed) from 1... AIM: To discuss important characteristics of the useof dental implants in posterior quadrants and the rehabilitation planning. METHODS: An electronic search of English articles was conducted on MEDLINE(PubM ed) from 1990 up to the period of March 2014. The key terms were dental implants and posterior jaws, dental implants/treatment planning and posterior maxilla, and dental implants/treatment planning and posterior mandible. No exclusion criteria were used for the initial search. Clinical trials, randomized and non randomized studies, classical and comparative studies, multicenter studies, in vitro and in vivo studies, case reports, longitudinal studies and reviews of the literature were included in this review. RESULTS: One hundred and fifty-two articles met the inclusion criteria of treatment planning of dental implants in posterior jaw and were read in their entirety. The selected articles were categorized with respect to their context on space for restoration, anatomic considerations(bone quantity and density), radiographic techniques, implant selection(number, position, diameter and surface), tilted and pterygoid implants, short implants, occlusal considerations, and success rates of implants placed in the posterior region. The results derived from the review process were described under several different topic headings to give readers a clear overview of the literature. In general, it was observed that the use of dental implants in posterior region requires a careful treatment plan. It is important that the practitioner has knowledge about the theme to evaluate the treatment parameters. CONCLUSION: The use of implants to restore the posterior arch presents many challenges and requires a detailed treatment planning. 展开更多
关键词 dental implants MANDIBLE MAXILLA Edentulous jaw Treatment
下载PDF
Investigation of a new design for zirconia dental implants 被引量:1
8
作者 朱锦文 杨东伟 Fai Ma 《Journal of Medical Colleges of PLA(China)》 CAS 2007年第5期303-311,共9页
Objective:To assess the biomechanical properties of a new design configuration for zirconia dental implants. Methods: The new design has a cylindrical shape that is partially hollow and porous in the bottom, which per... Objective:To assess the biomechanical properties of a new design configuration for zirconia dental implants. Methods: The new design has a cylindrical shape that is partially hollow and porous in the bottom, which permits the implants to be locked into the alveolar bone over time. It also utilizes bioactive glass coatings to increase adhesion to surrounding bone structure. Samples of the new design were fabricated in the laboratory and their material strength, hardness, and fracture toughness were evaluated. In addition, biocompatibility of the new design was evaluated through testing in dogs. Results: Results of mechanical tests indicate that structural properties of the new design exceed the usual requirements for implants. Moreover, animal tests suggest that there is appreciable improvement in lock-in strength and osteointegration. Conclusion: The new design configuration is biomechanically feasible and further research is warranted to improve the design for human use. 展开更多
关键词 牙齿植入 氧化锆陶瓷 假牙 牙科
下载PDF
Study of Tissue Engineered Dental Implants of human alveolar Bone-Evaluations on their osteogenic activities invitro 被引量:1
9
作者 WT4”HZ] YAO Hui 《Chinese Journal of Biomedical Engineering(English Edition)》 2000年第3期95-110,共16页
The development of the activated cellular bony implant, in light of the principle on tissue engineering, has brought about a new era to the fields of dental maxillofacial implantation. The present study separated the ... The development of the activated cellular bony implant, in light of the principle on tissue engineering, has brought about a new era to the fields of dental maxillofacial implantation. The present study separated the osteoblast like cells from human alveolar bone and seeded them into 3 types of biodegradable scaffold to form the complexes and then evaluated their osteogenic activities in vitro, in order to acquire experimental data that are essential to future clinical practice of this new type of therapeutical procedure in oral and maxillofacial surgery. Material and methods: Human alveolar bone origin cells were separated from alveolar bone around the third impacted teeth of 3 patients by enzyme digestion and went on cultures with α MEM containing β glycerophosphate and Dexamethasone at 5% CO2 ,37℃ for 21 28 days. Confirmed osteoblasts like cells were then seeded onto 3 types of degradable biomaterials of polyglycolic acid scaffold, collagen sponge, and L lactic acid/ε caprolactone to form cell matrices complexes. The 3 types of complex were continued to culture for 21 28 days in vitro at the same conditions with the single layer cultured cells. The cell proliferation, morphological changes, ALPase activity and mineral nodules formation on scaffolds were measured and observed at 3 days intervals to evaluate the affinities & the osteogenic activities of the human alveolar osteoblast like cells in the 3 different complexes. Result and discussion: The results indicated that the cultured human alveolar bone origin cells from 3 patients could successfully express the osteoblasts phenotype in single layered culturing in vitro after stimulated by β glycerophosphate and Dexamethasone. It has been shown that the cultured osteoblast like cells seeded on PGAS matrix had the highest attachmental, proliferative and osteogenic activities, suggesting a good bio affinity between the human alveolar osteoblast like cells and the PGAS matrix. The statistical analysis (ANOVA) showed that there were significant differences between PGAS osteoblasts complex and CLGS or LACT complexes on osteogenic activities. (P<0.05). It was also noticed that cultured human alveolar osteoblasts seeded in biodegradable materials had a delayed peak period on cell proliferation and PLAase production ,suggesting the osteoblasts seeded on scaffolds need a period of time to adjust themselves before they can normally proliferate and expres their phenotypes. Conclusion: PGAS osteoblasts complex is worth to be further developed into a tissue engineered cellular artificial bony implant for reconstructing the oral maxillofacial bony defects in a more effective way in the future. 展开更多
关键词 TISSUE engineering dental implants HUMAN ALVEOLAR OSTEOBLASTS biodegradable scaffold OSTEOGENIC ACTIVITIES in vitro evaluation
下载PDF
Burden of routine orthopedic implant removal a single center retrospective study
10
作者 Ammar K AlOmran Nader Alosaimi +6 位作者 Ahmed A Alshaikhi Omar M Bakhurji Khalid J Alzahrani Basil Ziyad Salloot Tamim Omar Alabduladhem Ahmed I AlMulhim Arwa Alumran 《World Journal of Orthopedics》 2024年第2期139-146,共8页
BACKGROUND Open reduction and internal fixation represent prevalent orthopedic procedures,sparking ongoing discourse over whether to retain or remove asymptomatic implants.Achieving consensus on this matter is paramou... BACKGROUND Open reduction and internal fixation represent prevalent orthopedic procedures,sparking ongoing discourse over whether to retain or remove asymptomatic implants.Achieving consensus on this matter is paramount for orthopedic surgeons.This study aims to quantify the impact of routine implant removal on patients and healthcare facilities.A retrospective analysis of implant removal cases from 2016 to 2022 at King Fahad Hospital of the University(KFHU)was conducted and subjected to statistical scrutiny.Among these cases,44%necessitated hospitalization exceeding one day,while 56%required only a single day.Adults exhibited a 55%need for extended hospital stays,contrasting with 22.8%among the pediatric cohort.The complication rate was 6%,with all patients experiencing at least one complication.Notably,34.1%required sick leave and 4.8%exceeded 14 d.General anesthesia was predominant(88%).Routine implant removal introduces unwarranted complications,particularly in adults,potentially prolonging hospitalization.This procedure strains hospital resources,tying up the operating room that could otherwise accommodate critical surgeries.Clearly defined institutional guidelines are imperative to regulate this practice.AIM To measure the burden of routine implant removal on the patients and hospital.METHODS This is a retrospective analysis study of 167 routine implant removal cases treated at KFHU,a tertiary hospital in Saudi Arabia.Data were collected in the orthopedic department at KFHU from February 2016 to August 2022,which includes routine asymptomatic implant removal cases across all age categories.Nonroutine indications such as infection,pain,implant failure,malunion,nonunion,restricted range of motion,and prominent hardware were excluded.Patients who had external fixators removed or joints replaced were also excluded.RESULTS Between February 2016 and August 2022,360 implants were retrieved;however,only 167 of those who met the inclusion criteria were included in this study.The remaining implants were rejected due to exclusion criteria.Among the cases,44%required more than one day in the hospital,whereas 56%required only one day.55%of adults required more than one day of hospitalization,while 22.8%of pediatric patients required more than one day of inpatient care.The complication rate was 6%,with each patient experiencing at least one complication.Sick leave was required in 34.1%of cases,with 4.8%requiring more than 14 d.The most common type of anesthesia used in the surgeries was general anesthesia(88%),and the mean(SD)surgery duration was 77.1(54.7)min.CONCLUSION Routine implant removal causes unnecessary complications,prolongs hospital stays,depletes resources and monopolizing operating rooms that could serve more critical procedures. 展开更多
关键词 implant removal Healed fracture Orthopedic implant complications Healthcare system
下载PDF
Osteotomy Protocol for Implant Insertion of One Day Biotech: One Drill, One Implant
11
作者 Jin Hwan Kim Jaehyun Song +3 位作者 Jaegyun Choi Jose Francisco Ballester Ireh Kim Santiago Jose Ballester 《Open Journal of Stomatology》 2024年第5期255-277,共23页
Background: Four factors determine the quality of an implantology kit: 1) Heat generated by the drills;2) Morphology of the osteotomy according to the diameter of the implant;3) Efficiency of collecting autologous bon... Background: Four factors determine the quality of an implantology kit: 1) Heat generated by the drills;2) Morphology of the osteotomy according to the diameter of the implant;3) Efficiency of collecting autologous bone;and 4) Osteotomy execution time. Materials and Methods: This article examines the heat produced by drills during osteotomy, focusing on the effect of the following factors: drilling technique;volume of autologous bone harvested;drilling time;implant primary stability;and the percentage of osseointegrated implants after primary healing. Discussion: The four factors mentioned above are analyzed based on the data obtained for sequential, biological, and One Drill milling techniques. Conclusions: 1) One Drill is the fastest technique for performing the osteotomy;2) All techniques stay within the biological temperature range of living bone, with the lowest increase in temperature achieved using One Drill with irrigation;3) The bone harvested showed no statistically significant differences between biological milling and the One Drill technique, both far superior to the sequential technique;and 4) There is no statistically significant difference in the number of osseointegrated implants among the three techniques analyzed. 展开更多
关键词 dental implant Bur Primary Stability Drilling Time OSTEOTOMY Irrigation Bone Collected
下载PDF
Mechanical Experiment for 3D Printing of Titanium Bone Bionic Dental Implants
12
作者 Yanzheng SUN Jincheng WU +1 位作者 Yi LI Jianjun YANG 《Medicinal Plant》 CAS 2018年第4期91-93,96,共4页
[Objectives] To explore the flexural strength of 3D printed titanium bone bionic dental implants and provide a scientific basis for the clinical application of 3D printed porous bionic bone dental implants. [Methods] ... [Objectives] To explore the flexural strength of 3D printed titanium bone bionic dental implants and provide a scientific basis for the clinical application of 3D printed porous bionic bone dental implants. [Methods] The cone-beam CT( CBCT) image information of 20 premolars extracted by orthodontic requirement was collected,and a new porous bone bionic dental implant was produced using modeling software and 3D printer. The premolars were divided into two groups( A and B). The universal testing machine was used to test the flexural strength of the two groups and the difference in flexural strength between the two groups was compared through statistics. [Results]Twenty 3D printed porous titanium bone bionic implants were accurately produced; the morphology of group A and group B were extremely similar to each other; the average flexural strength of group A was 2 767. 92 N,while the average flexural strength of group B was 778. 77 N,showing that the average flexural strength of group A was significantly higher than that of group B,and the difference was statistically significant( P < 0. 05).[Conclusions]The personalized porous structure root implants produced by 3D printing technology are very similar to the target tooth morphology,and show high accuracy and small error of production. Besides,the flexural strength of 3D printed personalized porous structure root implants can fully meet the requirements of the maximum occlusal force for dental implant restoration. It is expected to provide a scientific basis for clinical application of 3 D printed porous bionic bone tooth implants. 展开更多
关键词 dental implant 3D printing technology Porous bionic bone tooth implant Flexural strength
下载PDF
Comparison of complications after Ahmed versus Baerveldt implant in glaucoma patients:one year follow-up
13
作者 Sara Listyani Koentjoro Widya Artini +6 位作者 Iwan Soebijantoro Vira Wardhana Istiantoro Emma Rusmayani Rini Sulastiwaty Zeiras Eka Djamal Arini Safira Nurul Akbar Muhammad Yoserizal 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第12期1908-1914,共7页
AIM:To compare surgical results of the Ahmed and Baerveldt implant procedures in glaucoma patients at 1 y follow-up at Jakarta Eye Center(JEC)Eye Hospitals.METHODS:This cohort retrospective study was conducted on glau... AIM:To compare surgical results of the Ahmed and Baerveldt implant procedures in glaucoma patients at 1 y follow-up at Jakarta Eye Center(JEC)Eye Hospitals.METHODS:This cohort retrospective study was conducted on glaucoma patients aged≥18 y who had undergone Ahmed and Baerveldt implant surgery.Intraocular pressure(IOP),visual acuity,glaucoma medication,success rate,early and late postoperative complications,and the number of resurgeries were analyzed.RESULTS:A total of 351 eyes in the Ahmed group and 94 eyes in the Baerveldt group were included in this study.At 1 y follow-up,the mean IOP was found to be significantly lower in the Baerveldt group(13±4.47 mm Hg)compared to the Ahmed group(15.02±5.73 mm Hg;P=0.025).Glaucoma medication was required in both the Ahmed and Baerveldt groups(58.92%vs 71.67%).Comparable success rate was found in both groups.The Ahmed group revealed a complete and qualified success of 86.82%,and failure of 13.17%.Similarly,the Baerveldt group showed complete and qualified success in 87.75%and failure in 12.25%cases.In the Ahmed group,11.97%early complications,26.06%late complications and 9.97%resurgeries were observed.In comparison,in the Baerveldt group,23.40%early complications,30.95%late complications and 11.70%resurgeries were observed.CONCLUSION:Both groups of glaucoma implants show significant IOP reduction,however,the Baerveldt implant group demonstrates greater IOP reduction with more failure rates and complications than the Ahmed implant group. 展开更多
关键词 Ahmed implant Baerveldt implant intraocular pressure success rate complications
下载PDF
Awareness of Patients toward Dental Implants as an Alternative Treatment to Replace Missing Teeth in Kinshasa, D. R. Congo
14
作者 Em Kalala-Kazadi Patrick Disidi-Yakini +2 位作者 Fidèle Nyimi-Bushaba Edize Ekofo-Ingaya Augustin Mantshumba-Milolo 《Open Journal of Stomatology》 2018年第12期345-353,共9页
Background: Dental implant is an artificial root inserted in the jawbone, which restores a lost tooth so that it looks, feels, and is fit like a natural tooth. It is considered to be the best treatment option for sing... Background: Dental implant is an artificial root inserted in the jawbone, which restores a lost tooth so that it looks, feels, and is fit like a natural tooth. It is considered to be the best treatment option for single or multiple missing teeth. The aim of this study was to assess the awareness of patients about dental implants as an alternative treatment in Congolese patients. Materials and Methods: A cross-sectional study was conducted in two institutions namely, CBCO Bandal and Ngaliema Clinic, from August to December 2017. A total of 450 respondents have participated in the survey. A printed questionnaire comprised of 20 questions in order to evaluate patients dental awareness was used. Gender, level of education, awareness of dental implant and dental implants therapy, sources of information and the expectation about the sources of information were assessed. The collected data were entered in Microsoft Excel 2010 and analyzed by SPSS (IBM SPSS 20.0, Chicago, IL, USA) software. Results: Out of 450 participants, 14.4% were aware of dental implants. The main disadvantage of dental implant was the high cost. When asked about the anchorage, 86% didn’t know where the dental implant was anchored. Ninety-two percent didn’t know for how long an implant last, 6% thought that dental implant last for a lifetime. When patients were asked about the sources of information, the dentist (5%) and media (5.5%) were the main sources of information. The majority of patients (88.4%) would like to get information about dental implants from their dentist. Conclusion: Dentists should be more involved in the promotion of information about dental implants as a treatment modality to replace missing teeth. 展开更多
关键词 AWARENESS dental implant Treatment MODALITY ORAL Rehabilitation
下载PDF
Evaluation of titanium dental implants after early failure of osseointegration by means of X-ray photoelectron spectoscopy, electron microscopy and histological studies
15
作者 P. Lázaro M. Herrero F. J. Gil 《Journal of Biomedical Science and Engineering》 2010年第11期1073-1077,共5页
In this work, we analysed 56 clinically failed and retrieved implants by means of scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and histological studies. The surface contamination was comp... In this work, we analysed 56 clinically failed and retrieved implants by means of scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and histological studies. The surface contamination was compared to that of unused control implants and with that of the same implants after cleaning in a basic medium. The surfaces of the unused implants presented considerable contamination. In particular, high levels of carbon were detected. The nature of this C was elucidated by XPS analysis of the lubricant used in the machining process. The same contamination was observed in the retrieved implants. Histological studies were carried out by means of light microscopy. Fibrosis and granulomatous lesions were detected in the tissues. XPS analysis indicated the presence of traces of other elements (Na, Ca, Zn, S, F, etc.) that were not related to impurities in cpTi. We examined a cleaning process in a basic medium that eliminates the organic components of the implant surfaces. The cleaned implants were implanted in the patients and the results were excellent. None of the implants failed in following 7 months. 展开更多
关键词 dental implant TITANIUM CONTAMINATION OSSEOINTEGRATION
下载PDF
Replacing Missing Teeth with Dental Implants in Pubescent Patients—A Case Report
16
作者 Wendy C. W. Wang Loana Tovar Suinaga +1 位作者 Klenise S. Paranhos Sang-Choon Cho 《Open Journal of Pediatrics》 2015年第3期207-212,共6页
Tooth loss due to traumatic dental injury or congenital absence can cause functional and social- psychological consequences in youth. Pubescent children with missing teeth are often targets for school bullying. The tr... Tooth loss due to traumatic dental injury or congenital absence can cause functional and social- psychological consequences in youth. Pubescent children with missing teeth are often targets for school bullying. The treatment modality chosen can impact their well-being during their formative years. Despite the high success rate in adult patients, implant placement in young patients is not common due to its ankylosed nature and concerns with possible infra-occlusion in the future. However, skeletal growth and remodeling is a continuous process throughout life and postponement of dental implant placement does not necessary prevent future complication or need for replacement. Dental implant placement should be considered as a viable treatment option for pubescent patients if all other conventional alternatives fail to alleviate patients’ concerns both functionally and psychologically. This case report evaluates the considerations required to place dental implants in pubescent patients, as well as its advantages and disadvantages. 展开更多
关键词 dental implants Pubescent Social-Psychological BULLYING
下载PDF
I Do Biotech Dental Implants: Prospective Multicentric Study after 5 Years of Functional Loading
17
作者 J. F. Ballester Ferrandis Song Jae Hyun +8 位作者 Kim Jong Yeon Anaraki Mohaammad Varun Goel Shaker Tarawneh Ming Yang De Darabi Mohammadreza Ysang Century Tian Han Qing S. J. Ballester Bon 《Open Journal of Stomatology》 2020年第6期121-139,共19页
<b><span style="font-family:Verdana;">Introduction:</span></b><span style="font-family:Verdana;"> I Do Biotech’s implants were developed starting in 2014. Since then,... <b><span style="font-family:Verdana;">Introduction:</span></b><span style="font-family:Verdana;"> I Do Biotech’s implants were developed starting in 2014. Since then, they obtained GMP and KFDA licenses for distribution in 2015. The main objective of this paper is to determine the survival rate of I Do Biotech implants five years after the first surgery.</span><span style="font-family:Verdana;"> </span><b><span style="font-family:Verdana;">Material and Methods:</span></b><span style="font-family:Verdana;"> 1000 implants were used on 480 prosthes</span><span style="font-family:Verdana;">e</span><span style="font-family:Verdana;">s across 10 clinics on 320 healthy, non-smoker and non-diabetic patients, chosen at random, of which 160 are male and 160 female, all in the age range of 30 to 50 years old. The failure rate was studied related to the patient’s gender, the length and diameter of the implant, anatomical location, the percentage of peri-implantitis, prosthodontic failures and the patient’s quality of life.</span><span style="font-family:Verdana;"> </span><b><span style="font-family:Verdana;">Discussion:</span></b><span style="font-family:Verdana;"> The results obtained are similar to those of Van Steenberghe D. Dieter-Busenlechner, E. Serrano Catauria and far superior to those of Sáenz Guzmán. Failure rates vary greatly from study to study due to the heterogeneity of the samples in the other research papers. </span><b><span style="font-family:Verdana;">Conclusion:</span></b><span style="font-family:Verdana;"> The overall implant failure rate at 5 years is 1.7%. The factors affecting significantly the survival rate are: the implant diameter, its length and the anatomic area. Failure ratios increase significantly when the diameter or the length of the implant decrease</span><span style="font-family:Verdana;">s</span><span style="font-family:Verdana;">, and when they are placed in the posterior maxilla (up to 4.3%).</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">The rate of peri-implantitis is 5.1%. The prosthodontic failure rate is 2.91%. The improvement in quality of life and satisfaction increases with the years.</span> 展开更多
关键词 dental implants Titanium Morse Taper SLA Surface Multicentric Study PERI-implantITIS Prosthodontic Failures Study after 5 Years of Loading Quality of Life
下载PDF
Efficacy of PC-PRL implantation in the treatment of high myopia and its complications
18
作者 Wan-Jiang Dong Long Chen +4 位作者 Zhong Luo Su-Ying Yu Miao He Juan Wu Xian-Ming Lei 《Journal of Hainan Medical University》 2020年第2期42-45,共4页
Objective: To study the effect of implantable posterior chamber phakic refractive lens (PC-PRL) in the treatment of high myopia and its effect on naked eye vision and retinal complications. Methods: A total of 110 pat... Objective: To study the effect of implantable posterior chamber phakic refractive lens (PC-PRL) in the treatment of high myopia and its effect on naked eye vision and retinal complications. Methods: A total of 110 patients (220 eyes) with high myopia admitted to our hospital from June 2017 to February 2019 were selected as subjects. All patients were treated with PC-PRL implantation. The UCVA, BCVA, intraocular pressure, corneal endothelial cell count and intraocular lens position (anterior chamber depth and arch height) were compared before and after the treatment. Results: 6 months after treatment, 68.18% of patients had UCVA between 0.6 and 0.9, 31.81% of patients had UCVA of more than 1.0, and 100.00% of patients had BCVA of more than1.0. The BCVA and UCVA values of patients at 1 week, 1 month, 3 months and 6 months after operation were significantly greater than those before surgery (P<0.05). There were no significant differences in BCVA and UCVA among 1 week, 1 month, 3 months and 6 months after operation (P>0.05). The intraocular pressure was significantly greater than that of the preoperative one week after operation (P<0.05). There was no significant difference between the intraocular pressure at 1 month, 3 months and 6 months after operation (P>0.05). There was no significant difference in corneal endothelial cell count and arch height before and after treatment (P>0.05). The depth of anterior chamber at 3 months and 6 months after operation was significantly less than that before operation (P<0.05). There was no significant difference in the anterior chamber depth between 3 months and 6 months after operation (P<0.05). There were 7 cases of corneal edema, 4 cases of high pressure eyes, 2 cases of refractive regression within 6 months, and 1 case of near-difficulty within 1 month. The total complication rate was 12.73%. Conclusion: PC-PRL implantation is effective in the treatment of high myopia, which can improve the naked eye and correct vision. At the same time, the incidence of retinal complications is low, which can be promoted and applied clinically. 展开更多
关键词 high myopia PC-PRL implantation naked eye vision retinal complications
下载PDF
Reactivity of Titanium Dental Implants in Salivary Environment in the Presence of Foods Consumed in the Republic of the Congo
19
作者 Abel Dominique Eboungabeka Edith Rose Marcelle Eboungabeka Trigo Timothée Nsongo 《Advances in Materials Physics and Chemistry》 2021年第5期93-99,共7页
In this work, samples of titanium dental implants in salivary environment in the presence of certain foods were studied. 24 samples were prepared and subjected to the reactivity of certain foods for 6, 5, 6 and 7 week... In this work, samples of titanium dental implants in salivary environment in the presence of certain foods were studied. 24 samples were prepared and subjected to the reactivity of certain foods for 6, 5, 6 and 7 weeks. The ICP-MS technique was used to analyze the prepared samples. The results obtained showed no corrosion of the titanium alone in an artificial salivary medium. Significant corrosion was observed in the presence of food, which is manifested by the presence of traces of titanium in the samples. 展开更多
关键词 dental implant TITANIUM REACTIVITY FOOD
下载PDF
Prospects of 3D Printing Technology in Dental Medicine
20
作者 Ye Sun 《Journal of Clinical and Nursing Research》 2024年第6期398-403,共6页
With the continuous advancement of technology,the application of 3D printing technology in the field of dental medicine is becoming increasingly widespread.This article aims to explore the current applications and fut... With the continuous advancement of technology,the application of 3D printing technology in the field of dental medicine is becoming increasingly widespread.This article aims to explore the current applications and future potential of 3D printing technology in dental medicine and to analyze its benefits and challenges.It first introduces the current state of 3D printing technology in dental implants,crowns,bridges,orthodontics,and maxillofacial surgery.It then discusses the potential applications of 3D printing technology in oral tissue engineering,drug delivery systems,personalized dental prosthetics,and surgical planning.Finally,it analyzes the benefits of 3D printing technology in dental medicine,such as improving treatment accuracy and patient comfort,and shortening treatment times,while also highlighting the challenges faced,such as costs,material choices,and technical limitations.This article aims to provide a reference for professionals in the field of dental medicine and to promote the further application and development of 3D printing technology in this area. 展开更多
关键词 3D printing technology dental medicine dental implants CROWNS Bridges ORTHODONTICS Maxillofacial surgery Tissue engineering Drug delivery systems Personalized dental prosthetics Surgical planning
下载PDF
上一页 1 2 219 下一页 到第