BACKGROUND Prior studies have noted great variability in the plasma levels of risperidone(RIS).Plasma concentrations of RIS and its active moiety are highly variable and depend on absorption,metabolism,and other predi...BACKGROUND Prior studies have noted great variability in the plasma levels of risperidone(RIS).Plasma concentrations of RIS and its active moiety are highly variable and depend on absorption,metabolism,and other predictors of metabolic dysregulation;however,these factors are poorly understood and the association between metabolic change and change in psychopathology is uncertain.AIM To ascertain the characteristics of chronic schizophrenic patients treated with RIS,and to assess their relationship with plasma RIS levels.METHODS This was a descriptive cross-sectional study of 50 patients with a diagnosis of schizophrenic psychosis treated with RIS in a psychiatric service.The plasma concentrations of RIS and its metabolite 9-hydroxyrisperidone were determined by high performance liquid chromatography.The patients’demographic and clinical characteristics,and psychopathologies were assessed,and the associations between clinical variables and plasma levels of RIS were explored.RESULTS Male patients received higher doses of RIS than female ones,but plasma concentrations of RIS and risperidone+9-hydroxyrisperidone(active moiety)were higher in female patients.Age and the mean scores of the general psychopathology subscale of the Positive and Negative Syndrome Scale(PANSS)were significantly positively correlated with plasma concentrations of risperidone+9-hydroxyrisperidone adjusted for weight and dose in all 50 subjects.In male subjects,we found a statistically significant positive correlation between the concentrations of risperidone+9-hydroxyrisperidone in plasma/(dose×kg)and age,mean PANSS negative subscale scores,mean PANSS general psychopathology subscale scores,and mean PANSS total scores.CONCLUSION Long-term use of RIS should be closely monitored in older patients and females to minimize the risk of high concentrations which could induce side effects.展开更多
A fast, simple and sensitive high performance liquid chromatographic (HPLC) method has been developed for determination of 10a-methoxy-6-methyl ergoline-8b-methanol (MDL, a main metabolite of nicergoline) in human pla...A fast, simple and sensitive high performance liquid chromatographic (HPLC) method has been developed for determination of 10a-methoxy-6-methyl ergoline-8b-methanol (MDL, a main metabolite of nicergoline) in human plasma. One-step liquid–liquid extraction (LLE) with diethyl ether was employed as the sample preparation method. Tizanidine hydrochloride was selected as the internal standard (IS). Analysis was carried out on a Diamonsil ODS column (150 mm 4.6 mm, 5 mm) using acetonitrile–ammonium acetate (0.1 mol/L) (15/85, v/v) as mobile phase at detection wavelength of 224 nm. The calibration curves were linear over the range of 2.288–73.2 ng/mL with a lower limit of quantitation (LLOQ) of 2.288 ng/mL. The intra-and inter-day precision values were below 13% and the recoveries were from 74.47% to 83.20% at three quality control levels. The method herein described was successfully applied in a randomized crossover bioequivalence study of two different nicergoline preparations after administration of 30 mg in 20 healthy volunteers.展开更多
[Objectives]To establish a UPLC-UV method for the determination of polydatin in the serum of Wistar rats.[Methods]Acquity UPLC BEH shield RP18 column(1.7μm,2.1 mm×100 mm,Waters Corporation,USA)was used as the an...[Objectives]To establish a UPLC-UV method for the determination of polydatin in the serum of Wistar rats.[Methods]Acquity UPLC BEH shield RP18 column(1.7μm,2.1 mm×100 mm,Waters Corporation,USA)was used as the analytical column,acetonitrile-water(55∶45)was used as the mobile phase,the flow rate was 0.5 mL/min,and the column temperature was 30℃and the detection wavelength was 306 nm.[Results]The linear range of the established serum sample analysis method was 1.0-20.0μg/mL,and the correlation coefficient was r=0.9994;the intraday and interday RSD of Wistar rat serum was less than 3.0%,and the accuracy was higher than 90%.[Conclusions]This method is sensitive,accurate,and rapid.It is suitable for monitoring the concentration of polydatin in serum after intragastric administration,and can also be used for pharmacokinetics and bioavailability studies.展开更多
A new liquid chromatography-mass spectrometry method for the determination of carbamazepine,clonazepam,alprazolam,estazolam and phenytoin in human plasma has been developed by using diazepam as an internal standard.Ch...A new liquid chromatography-mass spectrometry method for the determination of carbamazepine,clonazepam,alprazolam,estazolam and phenytoin in human plasma has been developed by using diazepam as an internal standard.Chromatographic separation was performed on a Zorbax SB-C18 column(30 mm × 2.1 mm,3.5 ?m) with a mobile phase consisting of methanol and aqueous 25 mM ammonium acetate using gradient elution.A diethyl ether extraction method was used for the extraction of five anti-epilepsy drugs.The final extract was injected for analysis by LC-MS/MS.The method was validated within the concentration range of 50-5000 ng mL-1 for five anti-epilepsy drugs.The precision of the assay(RSD%) was less than 10% at all concentration levels within the tested range.The method recoveries for all samples were more than 90%.The results indicate that the method is specific,sensitive and accurate,and suitable to study the pharmacokinetics,to adjust the dosage for individual administration,and to monitor the drug-concentration and drug abuse of the five anti-epilepsy drugs.展开更多
基金Supported by Shanghai Civil Administration Bureau,No.8-2-50.
文摘BACKGROUND Prior studies have noted great variability in the plasma levels of risperidone(RIS).Plasma concentrations of RIS and its active moiety are highly variable and depend on absorption,metabolism,and other predictors of metabolic dysregulation;however,these factors are poorly understood and the association between metabolic change and change in psychopathology is uncertain.AIM To ascertain the characteristics of chronic schizophrenic patients treated with RIS,and to assess their relationship with plasma RIS levels.METHODS This was a descriptive cross-sectional study of 50 patients with a diagnosis of schizophrenic psychosis treated with RIS in a psychiatric service.The plasma concentrations of RIS and its metabolite 9-hydroxyrisperidone were determined by high performance liquid chromatography.The patients’demographic and clinical characteristics,and psychopathologies were assessed,and the associations between clinical variables and plasma levels of RIS were explored.RESULTS Male patients received higher doses of RIS than female ones,but plasma concentrations of RIS and risperidone+9-hydroxyrisperidone(active moiety)were higher in female patients.Age and the mean scores of the general psychopathology subscale of the Positive and Negative Syndrome Scale(PANSS)were significantly positively correlated with plasma concentrations of risperidone+9-hydroxyrisperidone adjusted for weight and dose in all 50 subjects.In male subjects,we found a statistically significant positive correlation between the concentrations of risperidone+9-hydroxyrisperidone in plasma/(dose×kg)and age,mean PANSS negative subscale scores,mean PANSS general psychopathology subscale scores,and mean PANSS total scores.CONCLUSION Long-term use of RIS should be closely monitored in older patients and females to minimize the risk of high concentrations which could induce side effects.
文摘A fast, simple and sensitive high performance liquid chromatographic (HPLC) method has been developed for determination of 10a-methoxy-6-methyl ergoline-8b-methanol (MDL, a main metabolite of nicergoline) in human plasma. One-step liquid–liquid extraction (LLE) with diethyl ether was employed as the sample preparation method. Tizanidine hydrochloride was selected as the internal standard (IS). Analysis was carried out on a Diamonsil ODS column (150 mm 4.6 mm, 5 mm) using acetonitrile–ammonium acetate (0.1 mol/L) (15/85, v/v) as mobile phase at detection wavelength of 224 nm. The calibration curves were linear over the range of 2.288–73.2 ng/mL with a lower limit of quantitation (LLOQ) of 2.288 ng/mL. The intra-and inter-day precision values were below 13% and the recoveries were from 74.47% to 83.20% at three quality control levels. The method herein described was successfully applied in a randomized crossover bioequivalence study of two different nicergoline preparations after administration of 30 mg in 20 healthy volunteers.
基金Project of Traditional Chinese Medicine Administration of Guangxi Zhuang Autonomous Region(GZZC2019147)Project for Improving Basic Research Ability of Middle Aged and Young Teachers in Colleges and Universities of Guangxi in 2020(2020KY13034)+2 种基金The First Batch High-level Talent Scientific Research Project of The Affiliated Hospital of Youjiang Medical University for Nationalities in 2019(Y20196311)National Traditional Chinese Medicine Characteristic Technology Heritage Talent Training Program(2015481601003)Program of Youjiang Medical University for Nationalities(yy2018ky018).
文摘[Objectives]To establish a UPLC-UV method for the determination of polydatin in the serum of Wistar rats.[Methods]Acquity UPLC BEH shield RP18 column(1.7μm,2.1 mm×100 mm,Waters Corporation,USA)was used as the analytical column,acetonitrile-water(55∶45)was used as the mobile phase,the flow rate was 0.5 mL/min,and the column temperature was 30℃and the detection wavelength was 306 nm.[Results]The linear range of the established serum sample analysis method was 1.0-20.0μg/mL,and the correlation coefficient was r=0.9994;the intraday and interday RSD of Wistar rat serum was less than 3.0%,and the accuracy was higher than 90%.[Conclusions]This method is sensitive,accurate,and rapid.It is suitable for monitoring the concentration of polydatin in serum after intragastric administration,and can also be used for pharmacokinetics and bioavailability studies.
基金supported by the National Science & Technology Major Project (2009ZX09301-14)the National Natural Science Foundation of China (90817103,20775055 & 30973672)+1 种基金the Startup Funding for ZC’s Luojia Chair Professorship of Wuhan University (306276216 & 306271159)the Fundamental Research Funds for the Central Universities
文摘A new liquid chromatography-mass spectrometry method for the determination of carbamazepine,clonazepam,alprazolam,estazolam and phenytoin in human plasma has been developed by using diazepam as an internal standard.Chromatographic separation was performed on a Zorbax SB-C18 column(30 mm × 2.1 mm,3.5 ?m) with a mobile phase consisting of methanol and aqueous 25 mM ammonium acetate using gradient elution.A diethyl ether extraction method was used for the extraction of five anti-epilepsy drugs.The final extract was injected for analysis by LC-MS/MS.The method was validated within the concentration range of 50-5000 ng mL-1 for five anti-epilepsy drugs.The precision of the assay(RSD%) was less than 10% at all concentration levels within the tested range.The method recoveries for all samples were more than 90%.The results indicate that the method is specific,sensitive and accurate,and suitable to study the pharmacokinetics,to adjust the dosage for individual administration,and to monitor the drug-concentration and drug abuse of the five anti-epilepsy drugs.