期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Hydrogen Humidity Control in Water-hydrogen Inner Cooled Generatorand Refrigerating Hydrogen Moisture Removal Device
1
作者 Sun Shixiong Yao Zhongan(Waiqaoqiao Power Plant) 《Electricity》 1998年第3期20-22,共3页
关键词 Hydrogen Humidity Control in Water-hydrogen Inner Cooled Generatorand Refrigerating Hydrogen Moisture removal device
下载PDF
Evaluation of Hysteroscopic-guided Removal of Intrauterine Device in Shanghai: A Report of Four Dead Cases
2
作者 Jian-zhong KANG Chun-xia MENG +1 位作者 Xiao-ai LIU Li-nan CHENG 《Journal of Reproduction and Contraception》 CAS 2010年第2期111-116,共6页
Objective To analyze the possible cause leading to death during the procecture oy IUD removal under hysteroscopy and how it could be prevented. Methods All (11 110) cases of IUD removal under hysteroscopy performed ... Objective To analyze the possible cause leading to death during the procecture oy IUD removal under hysteroscopy and how it could be prevented. Methods All (11 110) cases of IUD removal under hysteroscopy performed at 87 hospitals in Shanghai from 2001 to 2007 were reviewed. Four dead cases were reported. Results Air embolism was suspected as the cause of death. Associated risk factors included insufficient preoperative preparation, short duration between surgeries, non-standard procedure, careless observation and untimely resuscitation. Conclusion This emphasizes the necessity of early interventions taken such as prevention, early detection and management of the fatal complications. 展开更多
关键词 removal of an intrauterine device HYSTEROSCOPY air embolism DEATH
原文传递
Removal of a bent tibial intramedullary nail: a rare case report and review of the literature
3
作者 Sameer Aggerwal Ashwani Soni Uttam C. Saini Nitesh Gahlot 《Chinese Journal of Traumatology》 CAS 2011年第2期107-110,共4页
Intramedullary interlocking nailing is a gold standard for treatment of tibial shaft fractures. Bending of a nail secondary to trauma is a rare complication, which may be encountered in healed or unhealed tibial shaft... Intramedullary interlocking nailing is a gold standard for treatment of tibial shaft fractures. Bending of a nail secondary to trauma is a rare complication, which may be encountered in healed or unhealed tibial shaft fractures. Removal of such bent nail is always a challenge. We reported this case to discuss various techniques for removal of bent nails and to share our experience in removing a bent tibial intramedullary nail in a 30-year-old man, who was admitted in our department with re-fracture of the right tibial shaft due to a roadside accident two years after the initial surgical treatment. The intramedullary nail, bent by 30 degrees and visible on anterioposterior as well as on lateral radiographs, was firstly weakened by partially cutting the convex wall, then straightened by applying external force, and finally removed by using the standard nail removal method. 展开更多
关键词 Fracture fivmton intramedullary Tibial fractures device removal
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部