期刊文献+
共找到1,726篇文章
< 1 2 87 >
每页显示 20 50 100
Diagnostic delay in inflammatory bowel diseases in a German population 被引量:2
1
作者 Elisabeth Blüthner Annalena Dehe +11 位作者 Carsten Büning Britta Siegmund Matthias Prager Jochen Maul Alexander Krannich Jan Preiß Bertram Wiedenmann Florian Rieder Raneem Khedraki Frank Tacke Andreas Sturm Anja Schirbel 《World Journal of Gastroenterology》 SCIE CAS 2024年第29期3465-3478,共14页
BACKGROUND Early diagnosis is key to prevent bowel damage in inflammatory bowel disease(IBD).Risk factor analyses linked with delayed diagnosis in European IBD patients are scarce and no data in German IBD patients ex... BACKGROUND Early diagnosis is key to prevent bowel damage in inflammatory bowel disease(IBD).Risk factor analyses linked with delayed diagnosis in European IBD patients are scarce and no data in German IBD patients exists.AIM To identify risk factors leading to prolonged diagnostic time in a German IBD cohort.METHODS Between 2012 and 2022,430 IBD patients from four Berlin hospitals were enrolled in a prospective study and asked to complete a 16-item questionnaire to determine features of the path leading to IBD diagnosis.Total diagnostic time was defined as the time from symptom onset to consulting a physician(patient waiting time)and from first consultation to IBD diagnosis(physician diagnostic time).Univariate and multivariate analyses were performed to identify risk factors for each time period.RESULTS The total diagnostic time was significantly longer in Crohn’s disease(CD)compared to ulcerative colitis(UC)patients(12.0 vs 4.0 mo;P<0.001),mainly due to increased physician diagnostic time(5.5 vs 1.0 mo;P<0.001).In a multivariate analysis,the predominant symptoms diarrhea(P=0.012)and skin lesions(P=0.028)as well as performed gastroscopy(P=0.042)were associated with longer physician diagnostic time in CD patients.In UC,fever was correlated(P=0.020)with shorter physician diagnostic time,while fatigue(P=0.011)and positive family history(P=0.046)were correlated with longer physician diagnostic time.CONCLUSION We demonstrated that CD patients compared to UC are at risk of long diagnostic delay.Future efforts should focus on shortening the diagnostic delay for a better outcome in these patients. 展开更多
关键词 diagnostic time diagnostic delay Crohn’s disease Ulcerative colitis GERMANY
下载PDF
Addressing diagnostic delays in inflammatory bowel diseases in Germany
2
作者 Shi-Yan Zhang Yin Lin 《World Journal of Gastroenterology》 SCIE CAS 2024年第41期4484-4489,共6页
Inflammatory bowel diseases(IBDs),including Crohn's disease(CD)and ulcerative colitis,are chronic inflammatory conditions of the gastrointestinal tract that necessitate timely diagnosis to prevent complications an... Inflammatory bowel diseases(IBDs),including Crohn's disease(CD)and ulcerative colitis,are chronic inflammatory conditions of the gastrointestinal tract that necessitate timely diagnosis to prevent complications and improve patient outcomes.Despite advancements in medical knowledge and diagnostic techniques,significant diagnostic delays persist,particularly in CD.The study by Blüthner et al,published in the World Journal of Gastroenterology,elucidates the diagnostic delays experienced by German patients with IBD and identifies key risk factors contributing to these delays. 展开更多
关键词 Inflammatory bowel disease Crohn's disease Ulcerative colitis diagnostic delay Physician diagnostic time Risk factors Early diagnosis Patient outcomes
下载PDF
A synthetic diagnostics platform for microwave imaging diagnostics in tokamaks
3
作者 李子涵 杨尚川 +5 位作者 徐新航 张立夫 渠承明 李诚普 庄革 谢锦林 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期38-45,共8页
Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has bee... Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has been established that facilitates microwave imaging reflectometry and electron cyclotron emission imaging.This platform utilizes plasma profiles as input and incorporates the finite-difference time domain,ray tracing and the radiative transfer equation to calculate the propagation of plasma spontaneous radiation and the external electromagnetic field in plasmas.Benchmark tests for classical cases have been conducted to verify the accuracy of every core module in the GSD platform.Finally,2D imaging of a typical electron temperature distribution is reproduced by this platform and the results are consistent with the given real experimental data.This platform also has the potential to be extended to 3D electromagnetic field simulations and other microwave diagnostics such as cross-polarization scattering. 展开更多
关键词 synthetic diagnostics tokamak plasmas microwave imaging diagnostics microwave imaging reflectometer electron cyclotron emission imaging
下载PDF
Stage at diagnosis of colorectal cancer through diagnostic route:Who should be screened? 被引量:9
4
作者 Nobukazu Agatsuma Takahiro Utsumi +11 位作者 Yoshitaka Nishikawa Takahiro Horimatsu Takeshi Seta Yukitaka Yamashita Yukari Tanaka Takahiro Inoue Yuki Nakanishi Takahiro Shimizu Mikako Ohno Akane Fukushima Takeo Nakayama Hiroshi Seno 《World Journal of Gastroenterology》 SCIE CAS 2024年第10期1368-1376,共9页
BACKGROUND Colorectal cancer(CRC)is a global health concern,with advanced-stage diagnoses contributing to poor prognoses.The efficacy of CRC screening has been well-established;nevertheless,a significant proportion of... BACKGROUND Colorectal cancer(CRC)is a global health concern,with advanced-stage diagnoses contributing to poor prognoses.The efficacy of CRC screening has been well-established;nevertheless,a significant proportion of patients remain unscreened,with>70%of cases diagnosed outside screening.Although identifying specific subgroups for whom CRC screening should be particularly recommended is crucial owing to limited resources,the association between the diagnostic routes and identification of these subgroups has been less appreciated.In the Japanese cancer registry,the diagnostic routes for groups discovered outside of screening are primarily categorized into those with comorbidities found during hospital visits and those with CRC-related symptoms.AIM To clarify the stage at CRC diagnosis based on diagnostic routes.METHODS We conducted a retrospective observational study using a cancer registry of patients with CRC between January 2016 and December 2019 at two hospitals.The diagnostic routes were primarily classified into three groups:Cancer screening,follow-up,and symptomatic.The early-stage was defined as Stages 0 or I.Multivariate and univariate logistic regressions were exploited to determine the odds of early-stage diagnosis in the symptomatic and cancer screening groups,referencing the follow-up group.The adjusted covariates were age,sex,and tumor location.RESULTS Of the 2083 patients,715(34.4%),1064(51.1%),and 304(14.6%)belonged to the follow-up,symptomatic,and cancer screening groups,respectively.Among the 2083 patients,CRCs diagnosed at an early stage were 57.3%(410 of 715),23.9%(254 of 1064),and 59.5%(181 of 304)in the follow-up,symptomatic,and cancer screening groups,respectively.The symptomatic group exhibited a lower likelihood of early-stage diagnosis than the follow-up group[P<0.001,adjusted odds ratio(aOR),0.23;95%confidence interval(95%CI):0.19-0.29].The likelihood of diagnosis at an early stage was similar between the follow-up and cancer screening groups(P=0.493,aOR for early-stage diagnosis in the cancer screening group vs follow-up group=1.11;95%CI=0.82-1.49).CONCLUSION CRCs detected during hospital visits for comorbidities were diagnosed earlier,similar to cancer screening.CRC screening should be recommended,particularly for patients without periodical hospital visits for comorbidities. 展开更多
关键词 Colorectal neoplasms Cancer registry diagnostic route Cancer screening Stage at diagnosis
下载PDF
Urinary exosomal microRNA-145-5p and microRNA-27a-3p act as noninvasive diagnostic biomarkers for diabetic kidney disease 被引量:2
5
作者 Lu-Lu Han Sheng-Hai Wang +1 位作者 Ming-Yan Yao Hong Zhou 《World Journal of Diabetes》 SCIE 2024年第1期92-104,共13页
BACKGROUND Diabetic kidney disease(DKD),characterized by increased urinary microalbumin levels and decreased renal function,is the primary cause of end-stage renal di-sease.Its pathological mechanisms are complicated ... BACKGROUND Diabetic kidney disease(DKD),characterized by increased urinary microalbumin levels and decreased renal function,is the primary cause of end-stage renal di-sease.Its pathological mechanisms are complicated and multifactorial;Therefore,sensitive and specific biomarkers are needed.Urinary exosome originate from diverse renal cells in nephron segments and partially mirror the pathological changes in the kidney.The microRNAs(miRNAs)in urinary exosome are remark-ably stable and highly tissue-specific for the kidney.METHODS Type 2 diabetic mellitus(T2DM)patients were recruited from the Second Hospital of Hebei Medical University and were divided into two groups:DM,diabetic pa-tients without albuminuria[urinary albumin to creatinine ratio(UACR)<30 mg/g]and DKD,diabetic patients with albuminuria(UACR≥30 mg/g).Healthy subjects were the normal control(NC)group.Urinary exosomal miR-145-5p,miR-27a-3p,and miR-29c-3p,were detected using real-time quantitative polymerase chain reaction.The correlation between exosomal miRNAs and the clinical in-dexes was evaluated.The diagnostic values of exosomal miR-145-5p and miR-27a-3p in DKD were determined using receiver operating characteristic(ROC)analysis.Biological functions of miR-145-5p were investigated by performing RESULTS Urinary exosomal expression of miR-145-5p and miR-27a-3p was more upregulated in the DKD group than in the DM group(miR-145-5p:4.54±1.45 vs 1.95±0.93,P<0.001;miR-27a-3p:2.33±0.79 vs 1.71±0.76,P<0.05)and the NC group(miR-145-5p:4.54±1.45 vs 1.55±0.83,P<0.001;miR-27a-3p:2.33±0.79 vs 1.10±0.51,P<0.001).The exosomal miR-145-5p and miR-27a-3p positively correlated with albuminuria and serum creatinine and negatively correlated with the estimated glomerular filtration rate.miR-27a-3p was also closely related to blood glucose,gly-cosylated hemoglobin A1c,and low-density lipoprotein cholesterol.ROC analysis revealed that miR-145-5p had a better area under the curve of 0.88[95%confidence interval(CI):0.784-0.985,P<0.0001]in diagnosing DKD than miR-27a-3p with 0.71(95%CI:0.547-0.871,P=0.0239).Bioinformatics analysis revealed that the target genes of miR-145-5p were located in the actin filament,cytoskeleton,and extracellular exosome and were involved in the pathological processes of DKD,including apoptosis,inflammation,and fibrosis.CONCLUSION Urinary exosomal miR-145-5p and miR-27a-3p may serve as novel noninvasive diagnostic biomarkers or promising therapeutic targets for DKD. 展开更多
关键词 Urinary exosome MicroRNA-145-5p MicroRNA-27a-3p Diabetic kidney disease diagnostic biomarkers
下载PDF
Exploring non-invasive diagnostics for metabolic dysfunctionassociated fatty liver disease 被引量:1
6
作者 Biao Qu Zheng Li 《World Journal of Gastroenterology》 SCIE CAS 2024年第28期3447-3451,共5页
The population with metabolic dysfunction-associated fatty liver disease(MAFLD)is increasingly common worldwide.Identification of people at risk of progression to advanced stages is necessary to timely offer intervent... The population with metabolic dysfunction-associated fatty liver disease(MAFLD)is increasingly common worldwide.Identification of people at risk of progression to advanced stages is necessary to timely offer interventions and appropriate care.Liver biopsy is currently considered the gold standard for the diagnosis and staging of MAFLD,but it has associated risks and limitations.This has spurred the exploration of non-invasive diagnostics for MAFLD,especially for steatohepatitis and fibrosis.These non-invasive approaches mostly include biomarkers and algorithms derived from anthropometric measurements,serum tests,imaging or stool metagenome profiling.However,they still need rigorous and widespread clinical validation for the diagnostic performance. 展开更多
关键词 Metabolic dysfunction-associated fatty liver disease Non-invasive diagnostics Circulating biomarkers Imaging biomarkers Stool microbial biomarkers
下载PDF
Clinical diagnostic advances in intestinal anastomotic techniques:Hand suturing,stapling,and compression devices 被引量:1
7
作者 Ah Young Lee Joo Young Cho 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第5期1231-1234,共4页
The development of intestinal anastomosis techniques,including hand suturing,stapling,and compression anastomoses,has been a significant advancement in surgical practice.These methods aim to prevent leakage and minimi... The development of intestinal anastomosis techniques,including hand suturing,stapling,and compression anastomoses,has been a significant advancement in surgical practice.These methods aim to prevent leakage and minimize tissue fibrosis,which can lead to stricture formation.The healing process involves various phases:hemostasis and inflammation,proliferation,and remodeling.Mechanical staplers and sutures can cause inflammation and fibrosis due to the release of profibrotic chemokines.Compression anastomosis devices,including those made of nickel-titanium alloy,offer a minimally invasive option for various surgical challenges and have shown safety and efficacy.However,despite advancements,anastomotic techniques are evaluated based on leakage risk,with complications being a primary concern.Newer devices like Magnamosis use magnetic rings for compression anastomosis,demonstrating greater strength and patency compared to stapling.Magnetic technology is also being explored for other medical treatments.While there are promising results,particularly in animal models,the realworld application in humans is limited,and further research is needed to assess their safety and practicality. 展开更多
关键词 ANASTOMOSES diagnostic advances Anastomotic techniques Technique Intestine
下载PDF
Metabolic dysfunction-associated steatotic liver disease:Navigating terminological evolution,diagnostic frontiers and therapeutic horizon-an editorial exploration 被引量:1
8
作者 Aleksandra Boldys Lukasz Buldak 《World Journal of Gastroenterology》 SCIE CAS 2024年第18期2387-2390,共4页
Metabolic dysfunction-associated steatotic liver disease(MASLD),once known as non-alcoholic fatty liver disease(NAFLD),represents a spectrum of liver disorders characterized by lipid accumulation within hepatocytes.Th... Metabolic dysfunction-associated steatotic liver disease(MASLD),once known as non-alcoholic fatty liver disease(NAFLD),represents a spectrum of liver disorders characterized by lipid accumulation within hepatocytes.The redefinition of NAFLD in 2023 marked a significant reposition in terminology,emphasizing a broader understanding of liver steatosis and its associated risks.MASLD is now recognized as a major risk factor for liver cirrhosis,hepatocellular carcinoma,and systemic complications such as cardiovascular diseases or systemic inflammation.Diagnostic challenges arise,particularly in identifying MASLD in lean individuals,necessitating updated diagnostic protocols and investing in non-invasive diagnostic tools.Therapeutically,there is an urgent need for effective treatments targeting MASLD,with emerging pharmacological options focusing on,among others,carbohydrate and lipid metabolism.Additionally,understanding the roles of bile acid metabolism,the microbiome,and dietary interventions in MASLD pathogenesis and management holds promise for innovative therapeutic approaches.There is a strong need to emphasize the importance of collaborative efforts in understanding,diagnosing,and managing MASLD to improve physicians’approaches and patient outcomes. 展开更多
关键词 Metabolic dysfunction-associated steatotic liver disease diagnostics Pathophysiology of metabolic dysfunction-associated steatotic liver disease Therapy of metabolic dysfunction-associated steatotic liver disease Therapeutic innovations
下载PDF
Progress of the bolometer diagnostic system on EAST
9
作者 Wen WEN Yanmin DUAN +6 位作者 Shanshan PAN Yan CHAO Songtao MAO Jing QIAN Lingyi MENG Panjun TANG Shiyao LIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第9期125-132,共8页
Measurements of the total radiated power and its spatial distribution are crucial for fusion research.On the experimental advanced superconducting tokamak(EAST),both the metal foil resistive bolometer and the absolute... Measurements of the total radiated power and its spatial distribution are crucial for fusion research.On the experimental advanced superconducting tokamak(EAST),both the metal foil resistive bolometer and the absolute extreme ultraviolet(AXUV)photodiodes have been used to quantify the radiated power.This article introduces the latest improvement of the bolometer diagnostic system on EAST.It also details the successful design and installation of new divertor AXUV cameras,which are dedicated to the investigation of divertor physics.The shielding components of the bolometer detector have been refined,and the article provides a detailed exposition of the double shielding structures that have been verified as effective in microwave shielding.Additionally,the changes in the radiated power distribution in the divertor region during the plasma detachment process are measured using the divertor AXUV camera.Finally,the radiated power measured by the AXUV detector and metal foil resistive bolometer are compared,and different detector performances are presented. 展开更多
关键词 radiated power bolometer diagnostic microwave shielding plasma detachment sensitivity degradation
下载PDF
Development of D_α band symmetrical visible optical diagnostic for boundary reconstruction on EAST tokamak
10
作者 陈明 沈飊 +4 位作者 Shinichiro KADO 郭笔豪 陈大龙 蔡福瑞 肖炳甲 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期44-53,共10页
To investigate the potential of utilizing visible spectral imaging for controlling the plasma boundary shape during stable operation of plasma in future tokamak, a D_α band symmetric visible light diagnostic system w... To investigate the potential of utilizing visible spectral imaging for controlling the plasma boundary shape during stable operation of plasma in future tokamak, a D_α band symmetric visible light diagnostic system was designed and implemented on the Experimental Advanced Superconducting Tokamak(EAST). This system leverages two symmetric optics for joint plasma imaging. The optical system exhibits a spatial resolution less than 2 mm at the poloidal cross-section, distortion within the field of view below 10%, and relative illumination of 91%.The high-quality images obtained enable clear observation of both the plasma boundary position and the characteristics of components within the vacuum vessel. Following system calibration and coordinate transformation, the image coordinate boundary features are mapped to the tokamak coordinate system. Utilizing this system, the plasma boundary was reconstructed, and the resulting representation showed alignment with the EFIT(Equilibrium Fitting) results. This underscores the system's superior performance in boundary reconstruction applications and provides a diagnostic foundation for boundary shape control based on visible spectral imaging. 展开更多
关键词 visible optical diagnostic plasma boundary reconstruction EAST
下载PDF
Storage time affects the level and diagnostic efficacy of plasma biomarkers for neurodegenerative diseases
11
作者 Lifang Zhao Mingkai Zhang +4 位作者 Qimeng Li Xuemin Wang Jie Lu Ying Han Yanning Cai 《Neural Regeneration Research》 SCIE CAS 2025年第8期2373-2381,共9页
Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is k... Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is known about the long-term stability of these biomarker proteins in plasma samples stored at-80°C.We aimed to explore how storage time would affect the diagnostic accuracy of these biomarkers using a large cohort.Plasma samples from 229 cognitively unimpaired individuals,encompassing healthy controls and those experiencing subjective cognitive decline,as well as 99 patients with cognitive impairment,comprising those with mild cognitive impairment and dementia,were acquired from the Sino Longitudinal Study on Cognitive Decline project.These samples were stored at-80°C for up to 6 years before being used in this study.Our results showed that plasma levels of Aβ42,Aβ40,neurofilament light chain,and glial fibrillary acidic protein were not significantly correlated with sample storage time.However,the level of total tau showed a negative correlation with sample storage time.Notably,in individuals without cognitive impairment,plasma levels of total protein and tau phosphorylated protein threonine 181(p-tau181)also showed a negative correlation with sample storage time.This was not observed in individuals with cognitive impairment.Consequently,we speculate that the diagnostic accuracy of plasma p-tau181 and the p-tau181 to total tau ratio may be influenced by sample storage time.Therefore,caution is advised when using these plasma biomarkers for the identification of neurodegenerative diseases,such as Alzheimer's disease.Furthermore,in cohort studies,it is important to consider the impact of storage time on the overall results. 展开更多
关键词 Alzheimer’s disease amyloid-β diagnostic ability glial fibrillary acidic protein NEURODEGENERATION neurofilament light chain plasma biomarkers single molecule array storage time tau
下载PDF
Evaluation of urea breath test as a diagnostic tool for Helicobacter pylori infection in adult dyspeptic patients
12
作者 Zeinab Nabil Ahmed Said Asmaa Mohamed El-Nasser 《World Journal of Gastroenterology》 SCIE CAS 2024年第17期2302-2307,共6页
In this editorial,we discuss the article in the World Journal of Gastroenterology.The article conducts a meta-analysis of the diagnostic accuracy of the urea breath test(UBT),a non-invasive method for detecting Helico... In this editorial,we discuss the article in the World Journal of Gastroenterology.The article conducts a meta-analysis of the diagnostic accuracy of the urea breath test(UBT),a non-invasive method for detecting Helicobacter pylori(H.pylori)infection in humans.It is based on radionuclide-labeled urea.Various methods,both invasive and non-invasive,are available for diagnosing H.pylori infection,inclu-ding endoscopy with biopsy,serology for immunoglobulin titers,stool antigen analysis,and UBT.Several guidelines recommend UBTs as the primary choice for diagnosing H.pylori infection and for reexamining after eradication therapy.It is used to be the first choice non-invasive test due to their high accuracy,specificity,rapid results,and simplicity.Moreover,its performance remains unaffected by the distribution of H.pylori in the stomach,allowing a high flow of patients to be tested.Despite its widespread use,the performance characteristics of UBT have been inconsistently described and remain incompletely defined.There are two UBTs available with Food and Drug Administration approval:The 13C and 14C tests.Both tests are affordable and can provide real-time results.Physicians may prefer the 13C test because it is non-radioactive,compared to 14C which uses a radioactive isotope,especially in young children and pregnant women.Although there was heterogeneity among the studies regarding the diagnostic accuracy of both UBTs,13C-UBT consistently outperforms the 14C-UBT.This makes the 13C-UBT the preferred diagnostic approach.Furthermore,the provided findings of the meta-analysis emphasize the significance of precise considerations when choosing urea dosage,assessment timing,and measurement techniques for both the 13C-UBT and 14C-UBT,to enhance diagnostic precision. 展开更多
关键词 Helicobacter pylori Urea breath test DIAGNOSIS diagnostic test accuracy META-ANALYSIS
下载PDF
Urea breath test for Helicobacter pylori infection in adult dyspeptic patients: A meta-analysis of diagnostic test accuracy
13
作者 Fabian Fellipe Bueno Lemos Caroline Tianeze de Castro +9 位作者 Marcel Silva Luz Gabriel Reis Rocha Gabriel Lima Correa Santos Luís Guilherme de Oliveira Silva Mariana Santos Calmon Cláudio Lima Souza Ana Carla Zarpelon-Schutz Kádima Nayara Teixeira Dulciene Maria de Magalhães Queiroz Fabrício Freire de Melo 《World Journal of Gastroenterology》 SCIE CAS 2024年第6期579-598,共20页
BACKGROUND Helicobacter pylori(H.pylori)infection has been well-established as a significant risk factor for several gastrointestinal disorders.The urea breath test(UBT)has emerged as a leading non-invasive method for... BACKGROUND Helicobacter pylori(H.pylori)infection has been well-established as a significant risk factor for several gastrointestinal disorders.The urea breath test(UBT)has emerged as a leading non-invasive method for detecting H.pylori.Despite numerous studies confirming its substantial accuracy,the reliability of UBT results is often compromised by inherent limitations.These findings underscore the need for a rigorous statistical synthesis to clarify and reconcile the diagnostic accuracy of the UBT for the diagnosis of H.pylori infection.AIM To determine and compare the diagnostic accuracy of 13C-UBT and 14C-UBT for H.pylori infection in adult patients with dyspepsia.METHODS We conducted an independent search of the PubMed/MEDLINE,EMBASE,and Cochrane Central databases until April 2022.Our search included diagnostic accuracy studies that evaluated at least one of the index tests(^(13)C-UBT or ^(14)C-UBT)against a reference standard.We used the QUADAS-2 tool to assess the methodo-logical quality of the studies.We utilized the bivariate random-effects model to calculate sensitivity,specificity,positive and negative test likelihood ratios(LR+and LR-),as well as the diagnostic odds ratio(DOR),and their 95%confidence intervals.We conducted subgroup analyses based on urea dosing,time after urea administration,and assessment technique.To investigate a possible threshold effect,we conducted Spearman correlation analysis,and we generated summary receiver operating characteristic(SROC)curves to assess heterogeneity.Finally,we visually inspected a funnel plot and used Egger’s test to evaluate publication bias.endorsing both as reliable diagnostic tools in clinical practice.CONCLUSION In summary,our study has demonstrated that ^(13)C-UBT has been found to outperform the ^(14)C-UBT,making it the preferred diagnostic approach.Additionally,our results emphasize the significance of carefully considering urea dosage,assessment timing,and measurement techniques for both tests to enhance diagnostic precision.Nevertheless,it is crucial for researchers and clinicians to evaluate the strengths and limitations of our findings before implementing them in practice. 展开更多
关键词 Helicobacter pylori Urea breath test DIAGNOSIS diagnostic test accuracy META-ANALYSIS
下载PDF
Diagnostic Accuracy of Computerized Bowel Sound Analysis with Non-Invasive Devices for Irritable Bowel Syndrome:A Systematic Review and Meta-Analysis
14
作者 Xia-Xiao Yan Yue-Lun Zhang +2 位作者 Yu-Pei Zhang Ying-Yun Yang Dong Wu 《Chinese Medical Sciences Journal》 CAS CSCD 2024年第2期122-130,共9页
Objective To assess the diagnostic accuracy of bowel sound analysis for irritable bowel syndrome(IBS)with a systematic review and meta-analysis.Methods We searched MEDLINE,Embase,the Cochrane Library,Web of Science,an... Objective To assess the diagnostic accuracy of bowel sound analysis for irritable bowel syndrome(IBS)with a systematic review and meta-analysis.Methods We searched MEDLINE,Embase,the Cochrane Library,Web of Science,and IEEE Xplore databases until September 2023.Cross-sectional and case-control studies on diagnostic accuracy of bowel sound analysis for IBS were identified.We estimated the pooled sensitivity,specificity,positive likelihood ratio,negative likeli-hood ratio,and diagnostic odds ratio with a 95% confidence interval(CI),and plotted a summary receiver operat-ing characteristic curve and evaluated the area under the curve.Results Four studies were included.The pooled diagnostic sensitivity,specificity,positive likelihood ratio,nega-tive likelihood ratio,and diagnostic odds ratio were 0.94(95%CI,0.87‒0.97),0.89(95%CI,0.81‒0.94),8.43(95%CI,4.81‒14.78),0.07(95%CI,0.03‒0.15),and 118.86(95%CI,44.18‒319.75),respectively,with an area under the curve of 0.97(95%CI,0.95‒0.98).Conclusions Computerized bowel sound analysis is a promising tool for IBS.However,limited high-quality data make the results'validity and applicability questionable.There is a need for more diagnostic test accuracy studies and better wearable devices for monitoring and analysis of IBS. 展开更多
关键词 irritable bowel syndrome bowel sound analysis diagnostic accuracy systematic review META-ANALYSIS
下载PDF
Early diagnostic strategies for colorectal cancer
15
作者 Shi-Cai Liu Han Zhang 《World Journal of Gastroenterology》 SCIE CAS 2024年第33期3818-3822,共5页
At present,cancer is still an important factor threatening human health.Colorectal cancer(CRC)is one of the top three most common cancers worldwide and one of the deadliest malignancies in humans.The latest data showe... At present,cancer is still an important factor threatening human health.Colorectal cancer(CRC)is one of the top three most common cancers worldwide and one of the deadliest malignancies in humans.The latest data showed that CRC incidence and mortality rank third and second,respectively,among global malignancies.Early and accurate diagnosis is crucial to reduce the morbidity,mortality and improve survival of patients with CRC,but the current early diagnostic methods have limitations.The effectiveness and compliance of diagnostic methods have a certain impact on whether people choose screening.In this editorial,we explore strategies for the early diagnosis of CRC,including stool-based,blood-based,direct visualization,and imaging examinations. 展开更多
关键词 Colorectal cancer diagnostic markers COLONOSCOPY Fecal immunochemical test Fecal occult blood test Circulating tumor cells Circulating tumor DNA
下载PDF
Diagnostic delay in inflammatory bowel disease:Current situation and problems
16
作者 Cong Dai Yu-Hong Huang Min Jiang 《World Journal of Gastroenterology》 SCIE CAS 2024年第44期4738-4740,共3页
In this article,we comment on the article by Blüthner et al published recently.Inflammatory bowel disease(IBD),including ulcerative colitis and Crohn’s disease,is a chronic relapsing and remitting condition prim... In this article,we comment on the article by Blüthner et al published recently.Inflammatory bowel disease(IBD),including ulcerative colitis and Crohn’s disease,is a chronic relapsing and remitting condition primarily as a consequence of intestinal inflammation.It is important about adopting early and effective treatment to control clinical symptoms of IBD patients.Diagnostic delay can lead to adverse clinical outcomes and increase disease burden.Diagnostic delay is multifactorial.There are some factors related to diagnostic delay,such as patient factors and healthcare factors.We focus on the diagnostic tools for IBD,the outcomes and factors of diagnostic delay of IBD. 展开更多
关键词 Inflammatory bowel disease Ulcerative colitis Crohn’s disease diagnostic delay Clinical outcome
下载PDF
Polarimeter–interferometer diagnostic using terahertz solid-state sources for fluctuation measurements on Keda Torus e Xperiment(KTX)
17
作者 汪兴康 毛文哲 +17 位作者 谢锦林 兰涛 李弘 刘阿娣 周楚 温晓辉 卫子安 吴捷 陈晨 刘东宽 饶贤昊 蔡虎 邬佳仁 邓鹏 刘海庆 丁卫星 庄革 刘万东 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期61-65,共5页
A multi-channel polarimeter-interferometer has been developed on the Keda Torus eXperiment(KTX)for the study of equilibrium dynamics and internal magnetic fluctuations.A three-wave technique based on terahertz solid-s... A multi-channel polarimeter-interferometer has been developed on the Keda Torus eXperiment(KTX)for the study of equilibrium dynamics and internal magnetic fluctuations.A three-wave technique based on terahertz solid-state sources(-650 GHz)is applied for simultaneous measurements of electron density and Faraday rotation angle.The output power of the microwave source is 2 mW.Faraday rotation effect using a rotating wave plate is tested with phase noise less than 0.8°,and the density phase noise is less than 0.9°.Measurement of Faraday rotation angle and density for discharges on KTX have demonstrated high sensitivity to internal MHD activities. 展开更多
关键词 plasma diagnostics INTERFEROMETRY TERAHERTZ POLARIMETER
下载PDF
Development of a diagnostic nomogram for alpha-fetoproteinnegative hepatocellular carcinoma based on serological biomarkers
18
作者 Li He Cui Zhang +7 位作者 Lan-Lan Liu Li-Ping Huang Wen-Jing Lu Yuan-Yuan Zhang De-Yong Zou Yu-Fei Wang Qing Zhang Xiao-Li Yang 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第6期2463-2475,共13页
BACKGROUND Hepatocellular carcinoma(HCC)is the third leading cause of cancer-related death worldwide.Serum biomarkers play an important role in the early diagnosis and prognosis of HCC.Because a certain percentage of ... BACKGROUND Hepatocellular carcinoma(HCC)is the third leading cause of cancer-related death worldwide.Serum biomarkers play an important role in the early diagnosis and prognosis of HCC.Because a certain percentage of HCC patients are negative for alpha-fetoprotein(AFP),the diagnosis of AFP-negative HCC is essential to improve the detection rate of HCC.AIM To establish an effective model for diagnosing AFP-negative HCC based on serum tumour biomarkers.METHODS A total of 180 HCC patients were enrolled in this study.The expression levels of GP73,des-γ-carboxyprothrombin(DCP),CK18-M65,and CK18-M30 were detected by a fully automated chemiluminescence analyser.The variables were selected by logistic regression analysis.Several models were constructed using stepwise backward logistic regression.The performance of the models was compared using the C statistic,integrated discrimination improvement,net reclassification improvement,and calibration curves.The clinical utility of the nomogram was assessed using decision curve analysis(DCA).RESULTS The results showed that the expression levels of GP73,DCP,CK18-M65,and CK18-M30 were significantly greater in AFP-negative HCC patients than in healthy controls(P<0.001).Multivariate logistic regression analysis revealed that GP73,DCP,and CK18-M65 were independent factors for diagnosing AFP-negative HCC.By comparing the diagnostic performance of multiple models,we included GP73 and CK18-M65 as the model variables,and the model had good discrimination ability(area under the curve=0.946)and good goodness of fit.The DCA curves indicated the good clinical utility of the nomogram.CONCLUSION Our study identified GP73 and CK18-M65 as serum biomarkers with certain application value in the diagnosis of AFP-negative HCC.The diagnostic nomogram based on CK18-M65 combined with GP73 demonstrated good performance and effectively identified high-risk groups of patients with HCC. 展开更多
关键词 Hepatocellular carcinoma Alpha-fetoprotein-negative diagnostic NOMOGRAM Biomarker
下载PDF
Optical design of a novel near-infrared phase contrast imaging(NI-PCI)diagnostic on the HL-2A tokamak
19
作者 徐皓 龚少博 +11 位作者 余羿 许敏 兰涛 王志斌 石中兵 聂林 赵光义 刘灏 周艺轩 袁子豪 肖晨雨 陈坚 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期31-37,共7页
The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of tr... The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1). 展开更多
关键词 phase contrast imaging near infrared laser plasma laser diagnostic
下载PDF
Ultrafast pulse-dilation framing camera and its application for time-resolved X-ray diagnostic
20
作者 Hou-Zhi Cai Qiu-Yan Luo +10 位作者 Kai-Xuan Lin Xuan Deng Jun-Kai Liu Kai-Zhi Yang Dong Wang Jia-Jie Chen Jia-Heng Wang Jing-Hua Long Li-Hong Niu Yun-Fei Lei Jin-Yuan Liu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第7期101-114,共14页
An ultrafast framing camera with a pulse-dilation device,a microchannel plate(MCP)imager,and an electronic imaging system were reported.The camera achieved a temporal resolution of 10 ps by using a pulse-dilation devi... An ultrafast framing camera with a pulse-dilation device,a microchannel plate(MCP)imager,and an electronic imaging system were reported.The camera achieved a temporal resolution of 10 ps by using a pulse-dilation device and gated MCP imager,and a spatial resolution of 100μm by using an electronic imaging system comprising combined magnetic lenses.The spatial resolution characteristics of the camera were studied both theoretically and experimentally.The results showed that the camera with combined magnetic lenses reduced the field curvature and acquired a larger working area.A working area with a diameter of 53 mm was created by applying four magnetic lenses to the camera.Furthermore,the camera was used to detect the X-rays produced by the laser-targeting device.The diagnostic results indicated that the width of the X-ray pulse was approximately 18 ps. 展开更多
关键词 Inertial confinement fusion Plasma diagnostics Framing camera Combined lenses Pulse-dilation
下载PDF
上一页 1 2 87 下一页 到第
使用帮助 返回顶部