期刊文献+
共找到12篇文章
< 1 >
每页显示 20 50 100
Radiography of a K_α X-ray source generated through ultrahigh picosecond laser–nanostructure target interaction 被引量:3
1
作者 王剑 赵宗清 +9 位作者 何卫华 朱斌 董克攻 吴玉迟 张天奎 高牛 周凯南 谢娜 周维民 谷渝秋 《Chinese Optics Letters》 SCIE EI CAS CSCD 2015年第3期18-21,共4页
Laser-driven ultrafast X-ray sources are widely used for diagnostic radiography. However, there is a large divergence of fast electrons when they are generated by an intense short-pulse laser interacting with a foil t... Laser-driven ultrafast X-ray sources are widely used for diagnostic radiography. However, there is a large divergence of fast electrons when they are generated by an intense short-pulse laser interacting with a foil target. We design a nanowire array target to achieve a more compact point X-ray source. Fast electrons are confined and guided by the nanowire array structure in order to generate a Kα source with a small spot size. In our work, the smallest measured source size is comparable to the laser spot size, while the conversion efficiency can reach 2.4 ×10^-4. 展开更多
关键词 diagnostic radiography Electron sources NANOWIRES X ray apparatus
原文传递
Spectral calibration in spectral domain optical coherence tomography 被引量:12
2
作者 王凯 丁志华 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第12期902-904,共3页
A novel spectral calibration method is developed for spectral domain optical coherence tomography system. The method is based on two measurements of interference spectra from two reference mirror positions. It removes... A novel spectral calibration method is developed for spectral domain optical coherence tomography system. The method is based on two measurements of interference spectra from two reference mirror positions. It removes the influence of dispersion mismatch, and hence accurately determines the spectral distribution on the line-scan charge-coupled device (CCD) for sequent precise interpolation. High quality imaging can be realized with this method. Elimination of the degradation effect caused by dispersion mismatch is verified experimentally, and improved two-dimensional (2D) imaging of fresh orange pulp based on the proposed spectral calibration method is demonstrated. 展开更多
关键词 CALIBRATION Charge coupled devices diagnostic radiography Medical imaging Optical tomography PHOTODEGRADATION Strain measurement TOMOGRAPHY
原文传递
Adaptive optics optical coherence tomography for retina imaging 被引量:5
3
作者 史国华 戴云 +3 位作者 王玲 丁志华 饶学军 张雨东 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第6期424-425,共2页
When optical coherence tomography (OCT) is used for human retina imaging, its transverse resolution is limited by the aberrations of human eyes. To overcome this disadvantage, a high resolution imaging system for li... When optical coherence tomography (OCT) is used for human retina imaging, its transverse resolution is limited by the aberrations of human eyes. To overcome this disadvantage, a high resolution imaging system for living human retina, which consists of a time domain OCT system and a 37-elements adaptive optics (AO) system, has been developed. The AO closed loop rate is 20 flames per second, and the OCT has a 6.7-μm axial resolution. In this paper, this system is introduced and the high resolution imaging results for retina are presented. 展开更多
关键词 Arctic engineering Computer networks diagnostic radiography Medical imaging Optical tomography Optoelectronic devices TOMOGRAPHY
原文传递
Measurement of crater geometries after laser ablation of bone tissue with optical coherence tomography 被引量:3
4
作者 詹振林 张先增 +1 位作者 叶青 谢树森 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第12期896-898,共3页
The feasibility of measuring crater geometries by use of optical coherence tomography (OCT) is examined. Bovine shank bone on a motorized translation stage with a motion velocity of 3 mm/s is ablated with a pulsed C... The feasibility of measuring crater geometries by use of optical coherence tomography (OCT) is examined. Bovine shank bone on a motorized translation stage with a motion velocity of 3 mm/s is ablated with a pulsed CO2 laser in vitro. The laser pulse repetition rate is 60 Hz and the spot size on the tissue surface is 0.5 mm. Crater geometries are evaluated immediately by both OCT and histology methods after laser irradiation. The results reveal that OCT is capable of measuring crater geometries rapidly and noninvasively as compared to histology. There are good correlation and agreement between crater depth estimates obtained by two techniques, whereas there exists distinct difference between crater width estimates when the carbonization at the sides of craters is not removed. 展开更多
关键词 Ablation Biological radiation effects BONE Carbon dioxide CARBONIZATION Coherent light diagnostic radiography Geometry HISTOLOGY Laser ablation Lasers Medical imaging Optical systems Optical tomography Tomography
原文传递
Experimental validation for time-domain fluorescence diffuse optical tomography of linear scheme 被引量:2
5
作者 高峰 张丽敏 +1 位作者 李娇 赵会娟 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第12期889-892,共4页
We present a full three-dimensional, featured-data algorithm for time-domain fluorescence diffuse optical tomography that inverts the Laplace-transformed time-domain coupled diffusion equations and employs a pair of a... We present a full three-dimensional, featured-data algorithm for time-domain fluorescence diffuse optical tomography that inverts the Laplace-transformed time-domain coupled diffusion equations and employs a pair of appropriate transform-factors to effectively separate the fluorescent yield and lifetime parameters. By use of a time-correlation single-photon counting system and the normalized Born formulation, we experimentally validate that the proposed scheme can achieve simultaneous reconstruction of the fluorescent yield and lifetime distributions with a reasonable accuracy. 展开更多
关键词 diagnostic radiography Image segmentation Medical imaging Optical tomography Three dimensional Time domain analysis TOMOGRAPHY
原文传递
In vitro birefringence imaging with spectral domain polarization-sensitive optical coherence tomography 被引量:1
6
作者 龚强 范传茂 +1 位作者 张帆 姚建铨 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第12期905-909,共5页
Spectral domain polarization-sensitive optical coherence tomography (SDPS-OCT) is a depth-resolved polarization-sensitive interferometry which integrates polarization optics into spectral domain optical co- herence ... Spectral domain polarization-sensitive optical coherence tomography (SDPS-OCT) is a depth-resolved polarization-sensitive interferometry which integrates polarization optics into spectral domain optical co- herence tomography (SD-OCT). This configuration can obtain birefringence information of samples and improve the imaging speed. In this paper, horizontally polarized light is used to replace natural light of the source. Then, right-rotated circularly polarized light is the incident sample light. To obtain two orthogonal components of the polarized interferogram, the reflected light of the reference arm is set to be 45° linearly polarized light. These two components are acquired by two spectrometers synchronously. The system was employed to achieve 12.8μm axial resolution and 4.36μm transverse resolution. We have imaged in vitro chicken tendon and muscle tissues with these svstem. 展开更多
关键词 BIREFRINGENCE Capillary flow Coherent light diagnostic radiography INTERFEROMETRY Light polarization Medical imaging Optical properties Optical tomography Polarization Strain measurement TENDONS TOMOGRAPHY
原文传递
Fast Monte Carlo inversion for extracting the optical properties of tubular tissues 被引量:1
7
作者 赵会娟 周晓青 +1 位作者 梁菊兰 张顺起 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第12期935-937,共3页
Reconstruction of absorption coefficient μa and scattering coefficient μs is very important for applications of diffuse optical tomography and near infrared spectroscopy. Aiming at the early cancer detection of cerv... Reconstruction of absorption coefficient μa and scattering coefficient μs is very important for applications of diffuse optical tomography and near infrared spectroscopy. Aiming at the early cancer detection of cervix and stomach, we present a fast inverse Monte-Carlo scheme for extracting μa and μs of a tubular tissue from the measurement on frequency domain. Results show that the computation time for reconstructing one set of μa and μs is less than 1 min and the relative errors in reconstruction are less than ±10% for the optical properties of normal cervical tissue and precancerous lesions. 展开更多
关键词 diagnostic radiography Infrared spectroscopy Medical imaging Monte Carlo methods Optical properties Optical tomography Restoration Spectroscopic analysis Tomography
原文传递
Electromagnetically induced transparency induced by a 100% amplitude-modulated coupling field 被引量:1
8
作者 李晓莉 张连水 +2 位作者 杨丽君 冯晓敏 赵敏 《Optoelectronics Letters》 EI 2009年第1期73-76,共4页
We present a study of electromagnetically induced transparency(EIT) under the excitation of a 100% amplitude-modulated(AM) coupling field.The EIT feature is associated with a Λ type three-level configuration where a ... We present a study of electromagnetically induced transparency(EIT) under the excitation of a 100% amplitude-modulated(AM) coupling field.The EIT feature is associated with a Λ type three-level configuration where a coupling and probe field couples two separate optical transitions and it is well-known that the spectrum of the swept probe field gives a simple single transparency feature induced by the single mode coupling field.It is shown that when a 100% AM coupling field is applied,there is an EIT doublet... 展开更多
关键词 Amplitude modulation diagnostic radiography Electric impedance Electric impedance tomography Probes TRANSPARENCY
原文传递
Spatial Fourier-decomposition optical fluorescence tomography-theoretical investigation
9
作者 刘诚 Dug Young Kim 朱健强 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第9期665-668,共4页
A new three-dimensional (3D) optical fluorescent tomographic imaging scheme is proposed with structured illumination and spatial Fourier-domain decomposition methods for the first time. In this spatial Fourierdecomp... A new three-dimensional (3D) optical fluorescent tomographic imaging scheme is proposed with structured illumination and spatial Fourier-domain decomposition methods for the first time. In this spatial Fourierdecomposition optical fluorescence tomography (SF-OFT), the intensity of focused excitation light from an objective lens is modulated to be a cosine function along the optical axis of the system. For a given position in a two-dimensional (2D) raster scanning process, the spatial frequency of the cosine function along the optical axis sweeps in a proper range while a series of fluorescence intensity are detected accordingly. By making an inverse discrete cosine transformation of these recorded intensity profiles, the distribution of fluorescent markers along the optical axis of a focused laser beam is obtained. A 3D optical fluorescent tomography can be achieved with this proposed SF-OFT technique with a simple 2D raster scanning process. 展开更多
关键词 diagnostic radiography FLUORESCENCE Image coding Light emission Light measurement LUMINESCENCE Medical imaging SCANNING Three dimensional TOMOGRAPHY
原文传递
Improving depth resolution of diffuse optical tomography with an exponential adjustment method based on maximum singular value of layered sensitivity
10
作者 牛海晶 郭平 +1 位作者 宋晓东 蒋田仔 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第12期886-888,共3页
The sensitivity of diffuse optical tomography (DOT) imaging exponentially decreases with the increase of photon penetration depth, which leads to a poor depth resolution for DOT. In this letter, an exponential adjus... The sensitivity of diffuse optical tomography (DOT) imaging exponentially decreases with the increase of photon penetration depth, which leads to a poor depth resolution for DOT. In this letter, an exponential adjustment method (EAM) based on maximum singular value of layered sensitivity is proposed. Optimal depth resolution can be achieved by compensating the reduced sensitivity in the deep medium. Simulations are performed using a semi-infinite model and the simulation results show that the EAM method can substantially improve the depth resolution of deeply embedded objects in the medium. Consequently, the image quality and the reconstruction accuracy for these objects have been largely improved. 展开更多
关键词 diagnostic radiography Electroabsorption modulators Image quality Light absorption Medical imaging Optical tomography
原文传递
Hepatic CT image query using Gabor features
11
作者 赵晨光 程红岩 庄天戈 《Chinese Optics Letters》 SCIE EI CAS CSCD 2004年第7期383-385,共3页
A retrieval scheme for liver computerize tomography (CT) images based on Gabor texture is presented. For each hepatic CT image, we manually delineate abnormal regions within liver area. Then, a continuous Gabor transf... A retrieval scheme for liver computerize tomography (CT) images based on Gabor texture is presented. For each hepatic CT image, we manually delineate abnormal regions within liver area. Then, a continuous Gabor transform is utilized to analyze the texture of the pathology bearing region and extract the corresponding feature vectors. For a given sample image, we compare its feature vector with those of other images. Similar images with the highest rank are retrieved. In experiments, 45 liver CT images are collected, and the effectiveness of Gabor texture for content based retrieval is verified. 展开更多
关键词 Biological organs Computerized tomography diagnostic radiography Feature extraction Mathematical transformations
原文传递
An efficient Jacobian scaling method for time-domain optical mammography
12
作者 马艺闻 高峰 +2 位作者 阮平巧 杨芳 赵会娟 《Chinese Optics Letters》 SCIE EI CAS CSCD 2010年第2期206-209,共4页
Time-domain diffuse optical tomography can efficiently reconstruct optical parameters which can be further applied in diagnosing early breast cancer. Nevertheless, the performances of reconstructed imaging are badly i... Time-domain diffuse optical tomography can efficiently reconstruct optical parameters which can be further applied in diagnosing early breast cancer. Nevertheless, the performances of reconstructed imaging are badly influenced by different Jacobian magnitudes of absorption coefficient and reduced scattering coefficient. With the introudction of a relative data type based on generalized pulse spectrum technique, an efficient Jacobian scaling method is proposed. The interrelated simulated validation is also revealed for the enhancing performances. 展开更多
关键词 diagnostic radiography Optical tomography
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部