In a recent case report in the World Journal of Clinical Cases,emphasized the crucial role of rapidly and accurately identifying pathogens to optimize patient treatment outcomes.Laboratory-on-a-chip(LOC)technology has...In a recent case report in the World Journal of Clinical Cases,emphasized the crucial role of rapidly and accurately identifying pathogens to optimize patient treatment outcomes.Laboratory-on-a-chip(LOC)technology has emerged as a transformative tool in health care,offering rapid,sensitive,and specific identification of microorganisms.This editorial provides a comprehensive overview of LOC technology,highlighting its principles,advantages,applications,challenges,and future directions.Success studies from the field have demonstrated the practical benefits of LOC devices in clinical diagnostics,epidemiology,and food safety.Comparative studies have underscored the superiority of LOC technology over traditional methods,showcasing improvements in speed,accuracy,and portability.The future integration of LOC with biosensors,artificial intelligence,and data analytics promises further innovation and expansion.This call to action emphasizes the importance of continued research,investment,and adoption to realize the full potential of LOC technology in improving healthcare outcomes worldwide.展开更多
Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is k...Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is known about the long-term stability of these biomarker proteins in plasma samples stored at-80°C.We aimed to explore how storage time would affect the diagnostic accuracy of these biomarkers using a large cohort.Plasma samples from 229 cognitively unimpaired individuals,encompassing healthy controls and those experiencing subjective cognitive decline,as well as 99 patients with cognitive impairment,comprising those with mild cognitive impairment and dementia,were acquired from the Sino Longitudinal Study on Cognitive Decline project.These samples were stored at-80°C for up to 6 years before being used in this study.Our results showed that plasma levels of Aβ42,Aβ40,neurofilament light chain,and glial fibrillary acidic protein were not significantly correlated with sample storage time.However,the level of total tau showed a negative correlation with sample storage time.Notably,in individuals without cognitive impairment,plasma levels of total protein and tau phosphorylated protein threonine 181(p-tau181)also showed a negative correlation with sample storage time.This was not observed in individuals with cognitive impairment.Consequently,we speculate that the diagnostic accuracy of plasma p-tau181 and the p-tau181 to total tau ratio may be influenced by sample storage time.Therefore,caution is advised when using these plasma biomarkers for the identification of neurodegenerative diseases,such as Alzheimer's disease.Furthermore,in cohort studies,it is important to consider the impact of storage time on the overall results.展开更多
BACKGROUND Brush cytology is the most commonly used technique for tissue acquisition during endoscopic retrograde cholangiopancreatography for the evaluation of biliary strictures.Nonetheless,brush cytology is limited...BACKGROUND Brush cytology is the most commonly used technique for tissue acquisition during endoscopic retrograde cholangiopancreatography for the evaluation of biliary strictures.Nonetheless,brush cytology is limited by its low sensitivity due to insufficient cellular yield.AIM To evaluate the impact of the sheath-rinse technique on improving the cellularity yield.METHODS A total of 112 patients with suspected malignant biliary strictures were enrolled at two tertiary centers in South Korea.The sample cellularity and diagnostic accuracy of brush-wash and sheath-rinse specimens were compared.RESULTS A significantly increased number of total cell clusters per representative 20×field was recorded in the sheath-rinse compared with the brush-wash specimens(median:12 vs 3,P<0.001).This trend persisted when large(>50 cells)clusters(median:8 vs 3,P<0.001),medium(6-49 cells)(median:7 vs 3,P<0.001),and small(2-5 cells)clusters(median:9 vs 3,P<0.001)were evaluated.Diagnostic accuracy and sensitivity for differentiating malignancy were superior with sheath-rinsing than with the brush-wash method(72.3%vs 62.5%,P<0.001 and 69.9%vs 59.2%,P<0.001,respectively).CONCLUSION Incorporating sheath-rinse specimens significantly improved the yield and diagnostic accuracy of biliary brush cytology.Sheath-rinsing should be integrated into routine clinical practice to improve diagnostic performance for biliary strictures.展开更多
In this editorial we comment on the article by Jiang et al.We focus on the Ence-phalApp Stroop test which is an innovative,smartphone-based tool specifically designed for screening minimal hepatic encephalopathy(MHE)i...In this editorial we comment on the article by Jiang et al.We focus on the Ence-phalApp Stroop test which is an innovative,smartphone-based tool specifically designed for screening minimal hepatic encephalopathy(MHE)in cirrhosis patients.Traditional MHE screening methods,while highly sensitive and specific,are often complex,time-consuming,and require controlled environmental con-ditions,limiting their widespread clinical use.The EncephalApp Stroop test si-mplifies the screening process,enhances diagnostic efficiency,and is applicable across diverse cultural contexts.However,the combination of additional bio-markers could further improve diagnostic accuracy.Despite its promising po-tential,more multicenter clinical studies are required to validate its effectiveness and applicability on a global scale.展开更多
The Doppler backscattering(DBS)diagnostic is widely used to measure the localized density fluctuations and the propagation velocity of turbulent structures.Microwave is launched at a frequency that approaches a cutoff...The Doppler backscattering(DBS)diagnostic is widely used to measure the localized density fluctuations and the propagation velocity of turbulent structures.Microwave is launched at a frequency that approaches a cutoff layer in the plasma at an angle oblique to the cutoff layer.A new Q-band multichannel DBS system based on a comb generator has been designed and tested for application on the HL-3 tokamak.With the comb generator and heterodyne scheme,the stability and flexibility of the new DBS system are improved.The new DBS diagnostic has a high output power(~10 dBm),good power flatness(<5 dB in Q-band),and frequency stability,and the inter-frequency separation is tunable remotely.This article introduces the system design,laboratory test results,and initial experimental results from the HL-3 tokamak.With the help of the newly developed multichannel DBS,the turbulence information can be studied with high temporal and spatial resolution.展开更多
BACKGROUND Early diagnosis is key to prevent bowel damage in inflammatory bowel disease(IBD).Risk factor analyses linked with delayed diagnosis in European IBD patients are scarce and no data in German IBD patients ex...BACKGROUND Early diagnosis is key to prevent bowel damage in inflammatory bowel disease(IBD).Risk factor analyses linked with delayed diagnosis in European IBD patients are scarce and no data in German IBD patients exists.AIM To identify risk factors leading to prolonged diagnostic time in a German IBD cohort.METHODS Between 2012 and 2022,430 IBD patients from four Berlin hospitals were enrolled in a prospective study and asked to complete a 16-item questionnaire to determine features of the path leading to IBD diagnosis.Total diagnostic time was defined as the time from symptom onset to consulting a physician(patient waiting time)and from first consultation to IBD diagnosis(physician diagnostic time).Univariate and multivariate analyses were performed to identify risk factors for each time period.RESULTS The total diagnostic time was significantly longer in Crohn’s disease(CD)compared to ulcerative colitis(UC)patients(12.0 vs 4.0 mo;P<0.001),mainly due to increased physician diagnostic time(5.5 vs 1.0 mo;P<0.001).In a multivariate analysis,the predominant symptoms diarrhea(P=0.012)and skin lesions(P=0.028)as well as performed gastroscopy(P=0.042)were associated with longer physician diagnostic time in CD patients.In UC,fever was correlated(P=0.020)with shorter physician diagnostic time,while fatigue(P=0.011)and positive family history(P=0.046)were correlated with longer physician diagnostic time.CONCLUSION We demonstrated that CD patients compared to UC are at risk of long diagnostic delay.Future efforts should focus on shortening the diagnostic delay for a better outcome in these patients.展开更多
BACKGROUND Colorectal cancer(CRC)is a global health concern,with advanced-stage diagnoses contributing to poor prognoses.The efficacy of CRC screening has been well-established;nevertheless,a significant proportion of...BACKGROUND Colorectal cancer(CRC)is a global health concern,with advanced-stage diagnoses contributing to poor prognoses.The efficacy of CRC screening has been well-established;nevertheless,a significant proportion of patients remain unscreened,with>70%of cases diagnosed outside screening.Although identifying specific subgroups for whom CRC screening should be particularly recommended is crucial owing to limited resources,the association between the diagnostic routes and identification of these subgroups has been less appreciated.In the Japanese cancer registry,the diagnostic routes for groups discovered outside of screening are primarily categorized into those with comorbidities found during hospital visits and those with CRC-related symptoms.AIM To clarify the stage at CRC diagnosis based on diagnostic routes.METHODS We conducted a retrospective observational study using a cancer registry of patients with CRC between January 2016 and December 2019 at two hospitals.The diagnostic routes were primarily classified into three groups:Cancer screening,follow-up,and symptomatic.The early-stage was defined as Stages 0 or I.Multivariate and univariate logistic regressions were exploited to determine the odds of early-stage diagnosis in the symptomatic and cancer screening groups,referencing the follow-up group.The adjusted covariates were age,sex,and tumor location.RESULTS Of the 2083 patients,715(34.4%),1064(51.1%),and 304(14.6%)belonged to the follow-up,symptomatic,and cancer screening groups,respectively.Among the 2083 patients,CRCs diagnosed at an early stage were 57.3%(410 of 715),23.9%(254 of 1064),and 59.5%(181 of 304)in the follow-up,symptomatic,and cancer screening groups,respectively.The symptomatic group exhibited a lower likelihood of early-stage diagnosis than the follow-up group[P<0.001,adjusted odds ratio(aOR),0.23;95%confidence interval(95%CI):0.19-0.29].The likelihood of diagnosis at an early stage was similar between the follow-up and cancer screening groups(P=0.493,aOR for early-stage diagnosis in the cancer screening group vs follow-up group=1.11;95%CI=0.82-1.49).CONCLUSION CRCs detected during hospital visits for comorbidities were diagnosed earlier,similar to cancer screening.CRC screening should be recommended,particularly for patients without periodical hospital visits for comorbidities.展开更多
An ultrafast framing camera with a pulse-dilation device,a microchannel plate(MCP)imager,and an electronic imaging system were reported.The camera achieved a temporal resolution of 10 ps by using a pulse-dilation devi...An ultrafast framing camera with a pulse-dilation device,a microchannel plate(MCP)imager,and an electronic imaging system were reported.The camera achieved a temporal resolution of 10 ps by using a pulse-dilation device and gated MCP imager,and a spatial resolution of 100μm by using an electronic imaging system comprising combined magnetic lenses.The spatial resolution characteristics of the camera were studied both theoretically and experimentally.The results showed that the camera with combined magnetic lenses reduced the field curvature and acquired a larger working area.A working area with a diameter of 53 mm was created by applying four magnetic lenses to the camera.Furthermore,the camera was used to detect the X-rays produced by the laser-targeting device.The diagnostic results indicated that the width of the X-ray pulse was approximately 18 ps.展开更多
The population with metabolic dysfunction-associated fatty liver disease(MAFLD)is increasingly common worldwide.Identification of people at risk of progression to advanced stages is necessary to timely offer intervent...The population with metabolic dysfunction-associated fatty liver disease(MAFLD)is increasingly common worldwide.Identification of people at risk of progression to advanced stages is necessary to timely offer interventions and appropriate care.Liver biopsy is currently considered the gold standard for the diagnosis and staging of MAFLD,but it has associated risks and limitations.This has spurred the exploration of non-invasive diagnostics for MAFLD,especially for steatohepatitis and fibrosis.These non-invasive approaches mostly include biomarkers and algorithms derived from anthropometric measurements,serum tests,imaging or stool metagenome profiling.However,they still need rigorous and widespread clinical validation for the diagnostic performance.展开更多
The development of intestinal anastomosis techniques,including hand suturing,stapling,and compression anastomoses,has been a significant advancement in surgical practice.These methods aim to prevent leakage and minimi...The development of intestinal anastomosis techniques,including hand suturing,stapling,and compression anastomoses,has been a significant advancement in surgical practice.These methods aim to prevent leakage and minimize tissue fibrosis,which can lead to stricture formation.The healing process involves various phases:hemostasis and inflammation,proliferation,and remodeling.Mechanical staplers and sutures can cause inflammation and fibrosis due to the release of profibrotic chemokines.Compression anastomosis devices,including those made of nickel-titanium alloy,offer a minimally invasive option for various surgical challenges and have shown safety and efficacy.However,despite advancements,anastomotic techniques are evaluated based on leakage risk,with complications being a primary concern.Newer devices like Magnamosis use magnetic rings for compression anastomosis,demonstrating greater strength and patency compared to stapling.Magnetic technology is also being explored for other medical treatments.While there are promising results,particularly in animal models,the realworld application in humans is limited,and further research is needed to assess their safety and practicality.展开更多
BACKGROUND Diabetic kidney disease(DKD),characterized by increased urinary microalbumin levels and decreased renal function,is the primary cause of end-stage renal di-sease.Its pathological mechanisms are complicated ...BACKGROUND Diabetic kidney disease(DKD),characterized by increased urinary microalbumin levels and decreased renal function,is the primary cause of end-stage renal di-sease.Its pathological mechanisms are complicated and multifactorial;Therefore,sensitive and specific biomarkers are needed.Urinary exosome originate from diverse renal cells in nephron segments and partially mirror the pathological changes in the kidney.The microRNAs(miRNAs)in urinary exosome are remark-ably stable and highly tissue-specific for the kidney.METHODS Type 2 diabetic mellitus(T2DM)patients were recruited from the Second Hospital of Hebei Medical University and were divided into two groups:DM,diabetic pa-tients without albuminuria[urinary albumin to creatinine ratio(UACR)<30 mg/g]and DKD,diabetic patients with albuminuria(UACR≥30 mg/g).Healthy subjects were the normal control(NC)group.Urinary exosomal miR-145-5p,miR-27a-3p,and miR-29c-3p,were detected using real-time quantitative polymerase chain reaction.The correlation between exosomal miRNAs and the clinical in-dexes was evaluated.The diagnostic values of exosomal miR-145-5p and miR-27a-3p in DKD were determined using receiver operating characteristic(ROC)analysis.Biological functions of miR-145-5p were investigated by performing RESULTS Urinary exosomal expression of miR-145-5p and miR-27a-3p was more upregulated in the DKD group than in the DM group(miR-145-5p:4.54±1.45 vs 1.95±0.93,P<0.001;miR-27a-3p:2.33±0.79 vs 1.71±0.76,P<0.05)and the NC group(miR-145-5p:4.54±1.45 vs 1.55±0.83,P<0.001;miR-27a-3p:2.33±0.79 vs 1.10±0.51,P<0.001).The exosomal miR-145-5p and miR-27a-3p positively correlated with albuminuria and serum creatinine and negatively correlated with the estimated glomerular filtration rate.miR-27a-3p was also closely related to blood glucose,gly-cosylated hemoglobin A1c,and low-density lipoprotein cholesterol.ROC analysis revealed that miR-145-5p had a better area under the curve of 0.88[95%confidence interval(CI):0.784-0.985,P<0.0001]in diagnosing DKD than miR-27a-3p with 0.71(95%CI:0.547-0.871,P=0.0239).Bioinformatics analysis revealed that the target genes of miR-145-5p were located in the actin filament,cytoskeleton,and extracellular exosome and were involved in the pathological processes of DKD,including apoptosis,inflammation,and fibrosis.CONCLUSION Urinary exosomal miR-145-5p and miR-27a-3p may serve as novel noninvasive diagnostic biomarkers or promising therapeutic targets for DKD.展开更多
BACKGROUND Despite significant advancements in the medical treatment of primary hepato-cellular carcinoma(PHC)in recent years,enhancing therapeutic effects and im-proving prognosis remain substantial challenges worldw...BACKGROUND Despite significant advancements in the medical treatment of primary hepato-cellular carcinoma(PHC)in recent years,enhancing therapeutic effects and im-proving prognosis remain substantial challenges worldwide.AIM To investigate the expression levels of serum vascular endothelial growth factor(VEGF)and interleukin(IL)-17 in patients with PHC and evaluate their diagnostic value while exploring their relationship with patients’clinical characteristics.METHODS The study included 50 patients with confirmed PHC who visited Wuhan Han-yang Hospital from January 2021 to January 2022,and 50 healthy individuals from the same period served as the control group.Serum VEGF and IL-17 levels in both groups were measured by Enzyme-Linked Immunosorbent Assay,and their diagnostic value was assessed using receiver operating characteristic(ROC)curves.Pearson correlation analysis was performed to examine the relationship between serum VEGF and IL-17 levels.Pathological data of the PHC patients were analyzed to determine the relationship between serum VEGF and IL-17 levels and pathological characteristics.RESULTS Serum VEGF and IL-17 levels were significantly higher in the study group com-pared to the control group(P<0.05).No significant association was observed between serum VEGF and IL-17 levels and gender,age,combined cirrhosis,tumor diameter,or degree of differentiation(P>0.05).However,there was a significant relationship between clinical TNM stage,tumor metastasis,and serum VEGF and IL-17 levels(P<0.05).Correlation analysis revealed a positive correlation between serum VEGF and IL-17(P<0.05).ROC analysis demonstrated that both serum VEGF and IL-17 had good diagnostic efficacy for PHC.CONCLUSION Serum VEGF and IL-17 levels were significantly higher in PHC patients compared to healthy individuals.Their levels were closely related to pathological features such as tumor metastasis and clinical TNM stage,and there was a significant positive correlation between VEGF and IL-17.These biomarkers may serve as valuable reference in-dicators for the early diagnosis and treatment guidance of PHC.展开更多
Metabolic dysfunction-associated steatotic liver disease(MASLD),once known as non-alcoholic fatty liver disease(NAFLD),represents a spectrum of liver disorders characterized by lipid accumulation within hepatocytes.Th...Metabolic dysfunction-associated steatotic liver disease(MASLD),once known as non-alcoholic fatty liver disease(NAFLD),represents a spectrum of liver disorders characterized by lipid accumulation within hepatocytes.The redefinition of NAFLD in 2023 marked a significant reposition in terminology,emphasizing a broader understanding of liver steatosis and its associated risks.MASLD is now recognized as a major risk factor for liver cirrhosis,hepatocellular carcinoma,and systemic complications such as cardiovascular diseases or systemic inflammation.Diagnostic challenges arise,particularly in identifying MASLD in lean individuals,necessitating updated diagnostic protocols and investing in non-invasive diagnostic tools.Therapeutically,there is an urgent need for effective treatments targeting MASLD,with emerging pharmacological options focusing on,among others,carbohydrate and lipid metabolism.Additionally,understanding the roles of bile acid metabolism,the microbiome,and dietary interventions in MASLD pathogenesis and management holds promise for innovative therapeutic approaches.There is a strong need to emphasize the importance of collaborative efforts in understanding,diagnosing,and managing MASLD to improve physicians’approaches and patient outcomes.展开更多
Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has bee...Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has been established that facilitates microwave imaging reflectometry and electron cyclotron emission imaging.This platform utilizes plasma profiles as input and incorporates the finite-difference time domain,ray tracing and the radiative transfer equation to calculate the propagation of plasma spontaneous radiation and the external electromagnetic field in plasmas.Benchmark tests for classical cases have been conducted to verify the accuracy of every core module in the GSD platform.Finally,2D imaging of a typical electron temperature distribution is reproduced by this platform and the results are consistent with the given real experimental data.This platform also has the potential to be extended to 3D electromagnetic field simulations and other microwave diagnostics such as cross-polarization scattering.展开更多
A multi-channel polarimeter-interferometer has been developed on the Keda Torus eXperiment(KTX)for the study of equilibrium dynamics and internal magnetic fluctuations.A three-wave technique based on terahertz solid-s...A multi-channel polarimeter-interferometer has been developed on the Keda Torus eXperiment(KTX)for the study of equilibrium dynamics and internal magnetic fluctuations.A three-wave technique based on terahertz solid-state sources(-650 GHz)is applied for simultaneous measurements of electron density and Faraday rotation angle.The output power of the microwave source is 2 mW.Faraday rotation effect using a rotating wave plate is tested with phase noise less than 0.8°,and the density phase noise is less than 0.9°.Measurement of Faraday rotation angle and density for discharges on KTX have demonstrated high sensitivity to internal MHD activities.展开更多
Inflammatory bowel diseases(IBDs),including Crohn's disease(CD)and ulcerative colitis,are chronic inflammatory conditions of the gastrointestinal tract that necessitate timely diagnosis to prevent complications an...Inflammatory bowel diseases(IBDs),including Crohn's disease(CD)and ulcerative colitis,are chronic inflammatory conditions of the gastrointestinal tract that necessitate timely diagnosis to prevent complications and improve patient outcomes.Despite advancements in medical knowledge and diagnostic techniques,significant diagnostic delays persist,particularly in CD.The study by Blüthner et al,published in the World Journal of Gastroenterology,elucidates the diagnostic delays experienced by German patients with IBD and identifies key risk factors contributing to these delays.展开更多
1) Background: Rapid and acurate diagnostic testing for case identification, quarantine, and contact tracing is essential for managing the COVID 19 pandemic. Rapid antigen detection tests are available, however, it is...1) Background: Rapid and acurate diagnostic testing for case identification, quarantine, and contact tracing is essential for managing the COVID 19 pandemic. Rapid antigen detection tests are available, however, it is important to evaluate their performances before use. We tested a rapid antigen detection of SARS-CoV-2, based on the immunochromatography (Boson Biotech SARS-CoV-2 Ag Test (Xiamen Boson Biotech Co., Ltd., China)) and the results were compared with the real time reverse transcriptase-Polymerase chain reaction (RT-PCR) (Gold standard) results;2) Methods: From November 2021 to December 2021, samples were collected from symptomatic patients and asymptomatic individuals referred for testing in a hospital during the second pandemic wave in Gabon. All these participants attending “CTA Angondjé”, a field hospital set up as part of the management of COVID-19 in Gabon. Two nasopharyngeal swabs were collected in all the patients, one for Ag test and the other for RT-PCR;3) Results: A total of 300 samples were collected from 189 symptomatic and 111 asymptomatic individuals. The sensitivity and specificity of the antigen test were 82.5% [95%CI 73.8 - 89.3] and 97.9 % [95%CI 92.2 - 98.2] respectively, and the diagnostic accuracy was 84.4% (95% CI: 79.8 - 88.3%). The antigen test was more likely to be positive for samples with RT-PCR Ct values ≤ 32, with a sensitivity of 89.8%;4) Conclusions: The Boson Biotech SARS-CoV-2 Ag Test has good sensitivity and can detect SARS-CoV-2 infection, especially among symptomatic individuals with low viral load. This test could be incorporated into efficient testing algorithms as an alternative to PCR to decrease diagnostic delays and curb viral transmission.展开更多
To investigate the potential of utilizing visible spectral imaging for controlling the plasma boundary shape during stable operation of plasma in future tokamak, a D_α band symmetric visible light diagnostic system w...To investigate the potential of utilizing visible spectral imaging for controlling the plasma boundary shape during stable operation of plasma in future tokamak, a D_α band symmetric visible light diagnostic system was designed and implemented on the Experimental Advanced Superconducting Tokamak(EAST). This system leverages two symmetric optics for joint plasma imaging. The optical system exhibits a spatial resolution less than 2 mm at the poloidal cross-section, distortion within the field of view below 10%, and relative illumination of 91%.The high-quality images obtained enable clear observation of both the plasma boundary position and the characteristics of components within the vacuum vessel. Following system calibration and coordinate transformation, the image coordinate boundary features are mapped to the tokamak coordinate system. Utilizing this system, the plasma boundary was reconstructed, and the resulting representation showed alignment with the EFIT(Equilibrium Fitting) results. This underscores the system's superior performance in boundary reconstruction applications and provides a diagnostic foundation for boundary shape control based on visible spectral imaging.展开更多
BACKGROUND Hepatocellular carcinoma(HCC)is the third leading cause of cancer-related death worldwide.Serum biomarkers play an important role in the early diagnosis and prognosis of HCC.Because a certain percentage of ...BACKGROUND Hepatocellular carcinoma(HCC)is the third leading cause of cancer-related death worldwide.Serum biomarkers play an important role in the early diagnosis and prognosis of HCC.Because a certain percentage of HCC patients are negative for alpha-fetoprotein(AFP),the diagnosis of AFP-negative HCC is essential to improve the detection rate of HCC.AIM To establish an effective model for diagnosing AFP-negative HCC based on serum tumour biomarkers.METHODS A total of 180 HCC patients were enrolled in this study.The expression levels of GP73,des-γ-carboxyprothrombin(DCP),CK18-M65,and CK18-M30 were detected by a fully automated chemiluminescence analyser.The variables were selected by logistic regression analysis.Several models were constructed using stepwise backward logistic regression.The performance of the models was compared using the C statistic,integrated discrimination improvement,net reclassification improvement,and calibration curves.The clinical utility of the nomogram was assessed using decision curve analysis(DCA).RESULTS The results showed that the expression levels of GP73,DCP,CK18-M65,and CK18-M30 were significantly greater in AFP-negative HCC patients than in healthy controls(P<0.001).Multivariate logistic regression analysis revealed that GP73,DCP,and CK18-M65 were independent factors for diagnosing AFP-negative HCC.By comparing the diagnostic performance of multiple models,we included GP73 and CK18-M65 as the model variables,and the model had good discrimination ability(area under the curve=0.946)and good goodness of fit.The DCA curves indicated the good clinical utility of the nomogram.CONCLUSION Our study identified GP73 and CK18-M65 as serum biomarkers with certain application value in the diagnosis of AFP-negative HCC.The diagnostic nomogram based on CK18-M65 combined with GP73 demonstrated good performance and effectively identified high-risk groups of patients with HCC.展开更多
Measurements of the total radiated power and its spatial distribution are crucial for fusion research.On the experimental advanced superconducting tokamak(EAST),both the metal foil resistive bolometer and the absolute...Measurements of the total radiated power and its spatial distribution are crucial for fusion research.On the experimental advanced superconducting tokamak(EAST),both the metal foil resistive bolometer and the absolute extreme ultraviolet(AXUV)photodiodes have been used to quantify the radiated power.This article introduces the latest improvement of the bolometer diagnostic system on EAST.It also details the successful design and installation of new divertor AXUV cameras,which are dedicated to the investigation of divertor physics.The shielding components of the bolometer detector have been refined,and the article provides a detailed exposition of the double shielding structures that have been verified as effective in microwave shielding.Additionally,the changes in the radiated power distribution in the divertor region during the plasma detachment process are measured using the divertor AXUV camera.Finally,the radiated power measured by the AXUV detector and metal foil resistive bolometer are compared,and different detector performances are presented.展开更多
文摘In a recent case report in the World Journal of Clinical Cases,emphasized the crucial role of rapidly and accurately identifying pathogens to optimize patient treatment outcomes.Laboratory-on-a-chip(LOC)technology has emerged as a transformative tool in health care,offering rapid,sensitive,and specific identification of microorganisms.This editorial provides a comprehensive overview of LOC technology,highlighting its principles,advantages,applications,challenges,and future directions.Success studies from the field have demonstrated the practical benefits of LOC devices in clinical diagnostics,epidemiology,and food safety.Comparative studies have underscored the superiority of LOC technology over traditional methods,showcasing improvements in speed,accuracy,and portability.The future integration of LOC with biosensors,artificial intelligence,and data analytics promises further innovation and expansion.This call to action emphasizes the importance of continued research,investment,and adoption to realize the full potential of LOC technology in improving healthcare outcomes worldwide.
基金supported by the National Key Research&Development Program of China,Nos.2021YFC2501205(to YC),2022YFC24069004(to JL)the STI2030-Major Project,Nos.2021ZD0201101(to YC),2022ZD0211800(to YH)+2 种基金the National Natural Science Foundation of China(Major International Joint Research Project),No.82020108013(to YH)the Sino-German Center for Research Promotion,No.M-0759(to YH)a grant from Beijing Municipal Science&Technology Commission(Beijing Brain Initiative),No.Z201100005520018(to JL)。
文摘Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is known about the long-term stability of these biomarker proteins in plasma samples stored at-80°C.We aimed to explore how storage time would affect the diagnostic accuracy of these biomarkers using a large cohort.Plasma samples from 229 cognitively unimpaired individuals,encompassing healthy controls and those experiencing subjective cognitive decline,as well as 99 patients with cognitive impairment,comprising those with mild cognitive impairment and dementia,were acquired from the Sino Longitudinal Study on Cognitive Decline project.These samples were stored at-80°C for up to 6 years before being used in this study.Our results showed that plasma levels of Aβ42,Aβ40,neurofilament light chain,and glial fibrillary acidic protein were not significantly correlated with sample storage time.However,the level of total tau showed a negative correlation with sample storage time.Notably,in individuals without cognitive impairment,plasma levels of total protein and tau phosphorylated protein threonine 181(p-tau181)also showed a negative correlation with sample storage time.This was not observed in individuals with cognitive impairment.Consequently,we speculate that the diagnostic accuracy of plasma p-tau181 and the p-tau181 to total tau ratio may be influenced by sample storage time.Therefore,caution is advised when using these plasma biomarkers for the identification of neurodegenerative diseases,such as Alzheimer's disease.Furthermore,in cohort studies,it is important to consider the impact of storage time on the overall results.
基金Supported by The Catholic Medical Center Research Foundation Made in The Program Year of 2022.
文摘BACKGROUND Brush cytology is the most commonly used technique for tissue acquisition during endoscopic retrograde cholangiopancreatography for the evaluation of biliary strictures.Nonetheless,brush cytology is limited by its low sensitivity due to insufficient cellular yield.AIM To evaluate the impact of the sheath-rinse technique on improving the cellularity yield.METHODS A total of 112 patients with suspected malignant biliary strictures were enrolled at two tertiary centers in South Korea.The sample cellularity and diagnostic accuracy of brush-wash and sheath-rinse specimens were compared.RESULTS A significantly increased number of total cell clusters per representative 20×field was recorded in the sheath-rinse compared with the brush-wash specimens(median:12 vs 3,P<0.001).This trend persisted when large(>50 cells)clusters(median:8 vs 3,P<0.001),medium(6-49 cells)(median:7 vs 3,P<0.001),and small(2-5 cells)clusters(median:9 vs 3,P<0.001)were evaluated.Diagnostic accuracy and sensitivity for differentiating malignancy were superior with sheath-rinsing than with the brush-wash method(72.3%vs 62.5%,P<0.001 and 69.9%vs 59.2%,P<0.001,respectively).CONCLUSION Incorporating sheath-rinse specimens significantly improved the yield and diagnostic accuracy of biliary brush cytology.Sheath-rinsing should be integrated into routine clinical practice to improve diagnostic performance for biliary strictures.
基金Supported by The Basic and Clinical Integration Project of Xi'an Jiaotong University,No.YXJLRH2022067.
文摘In this editorial we comment on the article by Jiang et al.We focus on the Ence-phalApp Stroop test which is an innovative,smartphone-based tool specifically designed for screening minimal hepatic encephalopathy(MHE)in cirrhosis patients.Traditional MHE screening methods,while highly sensitive and specific,are often complex,time-consuming,and require controlled environmental con-ditions,limiting their widespread clinical use.The EncephalApp Stroop test si-mplifies the screening process,enhances diagnostic efficiency,and is applicable across diverse cultural contexts.However,the combination of additional bio-markers could further improve diagnostic accuracy.Despite its promising po-tential,more multicenter clinical studies are required to validate its effectiveness and applicability on a global scale.
基金supported by National Natural Science Foundation of China(Nos.12105087,12275096,and 11922503)the Joint Funds of the National Natural Science Foundation of China(No.U21A20440)the Science and Technology Planning Project of Sichuan Province(No.2023YFG0139)。
文摘The Doppler backscattering(DBS)diagnostic is widely used to measure the localized density fluctuations and the propagation velocity of turbulent structures.Microwave is launched at a frequency that approaches a cutoff layer in the plasma at an angle oblique to the cutoff layer.A new Q-band multichannel DBS system based on a comb generator has been designed and tested for application on the HL-3 tokamak.With the comb generator and heterodyne scheme,the stability and flexibility of the new DBS system are improved.The new DBS diagnostic has a high output power(~10 dBm),good power flatness(<5 dB in Q-band),and frequency stability,and the inter-frequency separation is tunable remotely.This article introduces the system design,laboratory test results,and initial experimental results from the HL-3 tokamak.With the help of the newly developed multichannel DBS,the turbulence information can be studied with high temporal and spatial resolution.
文摘BACKGROUND Early diagnosis is key to prevent bowel damage in inflammatory bowel disease(IBD).Risk factor analyses linked with delayed diagnosis in European IBD patients are scarce and no data in German IBD patients exists.AIM To identify risk factors leading to prolonged diagnostic time in a German IBD cohort.METHODS Between 2012 and 2022,430 IBD patients from four Berlin hospitals were enrolled in a prospective study and asked to complete a 16-item questionnaire to determine features of the path leading to IBD diagnosis.Total diagnostic time was defined as the time from symptom onset to consulting a physician(patient waiting time)and from first consultation to IBD diagnosis(physician diagnostic time).Univariate and multivariate analyses were performed to identify risk factors for each time period.RESULTS The total diagnostic time was significantly longer in Crohn’s disease(CD)compared to ulcerative colitis(UC)patients(12.0 vs 4.0 mo;P<0.001),mainly due to increased physician diagnostic time(5.5 vs 1.0 mo;P<0.001).In a multivariate analysis,the predominant symptoms diarrhea(P=0.012)and skin lesions(P=0.028)as well as performed gastroscopy(P=0.042)were associated with longer physician diagnostic time in CD patients.In UC,fever was correlated(P=0.020)with shorter physician diagnostic time,while fatigue(P=0.011)and positive family history(P=0.046)were correlated with longer physician diagnostic time.CONCLUSION We demonstrated that CD patients compared to UC are at risk of long diagnostic delay.Future efforts should focus on shortening the diagnostic delay for a better outcome in these patients.
基金the Foundation for Cancer Research supported by Kyoto Preventive Medical Center and the Japan Society for the Promotion of Science(JSPS)Grants-in-Aid KAKENHI,No.JP 22K21080.
文摘BACKGROUND Colorectal cancer(CRC)is a global health concern,with advanced-stage diagnoses contributing to poor prognoses.The efficacy of CRC screening has been well-established;nevertheless,a significant proportion of patients remain unscreened,with>70%of cases diagnosed outside screening.Although identifying specific subgroups for whom CRC screening should be particularly recommended is crucial owing to limited resources,the association between the diagnostic routes and identification of these subgroups has been less appreciated.In the Japanese cancer registry,the diagnostic routes for groups discovered outside of screening are primarily categorized into those with comorbidities found during hospital visits and those with CRC-related symptoms.AIM To clarify the stage at CRC diagnosis based on diagnostic routes.METHODS We conducted a retrospective observational study using a cancer registry of patients with CRC between January 2016 and December 2019 at two hospitals.The diagnostic routes were primarily classified into three groups:Cancer screening,follow-up,and symptomatic.The early-stage was defined as Stages 0 or I.Multivariate and univariate logistic regressions were exploited to determine the odds of early-stage diagnosis in the symptomatic and cancer screening groups,referencing the follow-up group.The adjusted covariates were age,sex,and tumor location.RESULTS Of the 2083 patients,715(34.4%),1064(51.1%),and 304(14.6%)belonged to the follow-up,symptomatic,and cancer screening groups,respectively.Among the 2083 patients,CRCs diagnosed at an early stage were 57.3%(410 of 715),23.9%(254 of 1064),and 59.5%(181 of 304)in the follow-up,symptomatic,and cancer screening groups,respectively.The symptomatic group exhibited a lower likelihood of early-stage diagnosis than the follow-up group[P<0.001,adjusted odds ratio(aOR),0.23;95%confidence interval(95%CI):0.19-0.29].The likelihood of diagnosis at an early stage was similar between the follow-up and cancer screening groups(P=0.493,aOR for early-stage diagnosis in the cancer screening group vs follow-up group=1.11;95%CI=0.82-1.49).CONCLUSION CRCs detected during hospital visits for comorbidities were diagnosed earlier,similar to cancer screening.CRC screening should be recommended,particularly for patients without periodical hospital visits for comorbidities.
基金National Natural Science Foundation of China(NSFC)(No.11775147)Guangdong Basic and Applied Basic Research Foundation(Nos.2019A1515110130 and 2024A1515011832)+1 种基金Shenzhen Key Laboratory of Photonics and Biophotonics(ZDSYS20210623092006020)Shenzhen Science and Technology Program(Nos.JCYJ20210324095007020,JCYJ20200109105201936 and JCYJ20230808105019039).
文摘An ultrafast framing camera with a pulse-dilation device,a microchannel plate(MCP)imager,and an electronic imaging system were reported.The camera achieved a temporal resolution of 10 ps by using a pulse-dilation device and gated MCP imager,and a spatial resolution of 100μm by using an electronic imaging system comprising combined magnetic lenses.The spatial resolution characteristics of the camera were studied both theoretically and experimentally.The results showed that the camera with combined magnetic lenses reduced the field curvature and acquired a larger working area.A working area with a diameter of 53 mm was created by applying four magnetic lenses to the camera.Furthermore,the camera was used to detect the X-rays produced by the laser-targeting device.The diagnostic results indicated that the width of the X-ray pulse was approximately 18 ps.
基金Supported by The National Natural Science Foundation of China,No.82104525.
文摘The population with metabolic dysfunction-associated fatty liver disease(MAFLD)is increasingly common worldwide.Identification of people at risk of progression to advanced stages is necessary to timely offer interventions and appropriate care.Liver biopsy is currently considered the gold standard for the diagnosis and staging of MAFLD,but it has associated risks and limitations.This has spurred the exploration of non-invasive diagnostics for MAFLD,especially for steatohepatitis and fibrosis.These non-invasive approaches mostly include biomarkers and algorithms derived from anthropometric measurements,serum tests,imaging or stool metagenome profiling.However,they still need rigorous and widespread clinical validation for the diagnostic performance.
文摘The development of intestinal anastomosis techniques,including hand suturing,stapling,and compression anastomoses,has been a significant advancement in surgical practice.These methods aim to prevent leakage and minimize tissue fibrosis,which can lead to stricture formation.The healing process involves various phases:hemostasis and inflammation,proliferation,and remodeling.Mechanical staplers and sutures can cause inflammation and fibrosis due to the release of profibrotic chemokines.Compression anastomosis devices,including those made of nickel-titanium alloy,offer a minimally invasive option for various surgical challenges and have shown safety and efficacy.However,despite advancements,anastomotic techniques are evaluated based on leakage risk,with complications being a primary concern.Newer devices like Magnamosis use magnetic rings for compression anastomosis,demonstrating greater strength and patency compared to stapling.Magnetic technology is also being explored for other medical treatments.While there are promising results,particularly in animal models,the realworld application in humans is limited,and further research is needed to assess their safety and practicality.
基金Supported by the Nature Science Foundation of Hebei Province,No.H2023104011.
文摘BACKGROUND Diabetic kidney disease(DKD),characterized by increased urinary microalbumin levels and decreased renal function,is the primary cause of end-stage renal di-sease.Its pathological mechanisms are complicated and multifactorial;Therefore,sensitive and specific biomarkers are needed.Urinary exosome originate from diverse renal cells in nephron segments and partially mirror the pathological changes in the kidney.The microRNAs(miRNAs)in urinary exosome are remark-ably stable and highly tissue-specific for the kidney.METHODS Type 2 diabetic mellitus(T2DM)patients were recruited from the Second Hospital of Hebei Medical University and were divided into two groups:DM,diabetic pa-tients without albuminuria[urinary albumin to creatinine ratio(UACR)<30 mg/g]and DKD,diabetic patients with albuminuria(UACR≥30 mg/g).Healthy subjects were the normal control(NC)group.Urinary exosomal miR-145-5p,miR-27a-3p,and miR-29c-3p,were detected using real-time quantitative polymerase chain reaction.The correlation between exosomal miRNAs and the clinical in-dexes was evaluated.The diagnostic values of exosomal miR-145-5p and miR-27a-3p in DKD were determined using receiver operating characteristic(ROC)analysis.Biological functions of miR-145-5p were investigated by performing RESULTS Urinary exosomal expression of miR-145-5p and miR-27a-3p was more upregulated in the DKD group than in the DM group(miR-145-5p:4.54±1.45 vs 1.95±0.93,P<0.001;miR-27a-3p:2.33±0.79 vs 1.71±0.76,P<0.05)and the NC group(miR-145-5p:4.54±1.45 vs 1.55±0.83,P<0.001;miR-27a-3p:2.33±0.79 vs 1.10±0.51,P<0.001).The exosomal miR-145-5p and miR-27a-3p positively correlated with albuminuria and serum creatinine and negatively correlated with the estimated glomerular filtration rate.miR-27a-3p was also closely related to blood glucose,gly-cosylated hemoglobin A1c,and low-density lipoprotein cholesterol.ROC analysis revealed that miR-145-5p had a better area under the curve of 0.88[95%confidence interval(CI):0.784-0.985,P<0.0001]in diagnosing DKD than miR-27a-3p with 0.71(95%CI:0.547-0.871,P=0.0239).Bioinformatics analysis revealed that the target genes of miR-145-5p were located in the actin filament,cytoskeleton,and extracellular exosome and were involved in the pathological processes of DKD,including apoptosis,inflammation,and fibrosis.CONCLUSION Urinary exosomal miR-145-5p and miR-27a-3p may serve as novel noninvasive diagnostic biomarkers or promising therapeutic targets for DKD.
文摘BACKGROUND Despite significant advancements in the medical treatment of primary hepato-cellular carcinoma(PHC)in recent years,enhancing therapeutic effects and im-proving prognosis remain substantial challenges worldwide.AIM To investigate the expression levels of serum vascular endothelial growth factor(VEGF)and interleukin(IL)-17 in patients with PHC and evaluate their diagnostic value while exploring their relationship with patients’clinical characteristics.METHODS The study included 50 patients with confirmed PHC who visited Wuhan Han-yang Hospital from January 2021 to January 2022,and 50 healthy individuals from the same period served as the control group.Serum VEGF and IL-17 levels in both groups were measured by Enzyme-Linked Immunosorbent Assay,and their diagnostic value was assessed using receiver operating characteristic(ROC)curves.Pearson correlation analysis was performed to examine the relationship between serum VEGF and IL-17 levels.Pathological data of the PHC patients were analyzed to determine the relationship between serum VEGF and IL-17 levels and pathological characteristics.RESULTS Serum VEGF and IL-17 levels were significantly higher in the study group com-pared to the control group(P<0.05).No significant association was observed between serum VEGF and IL-17 levels and gender,age,combined cirrhosis,tumor diameter,or degree of differentiation(P>0.05).However,there was a significant relationship between clinical TNM stage,tumor metastasis,and serum VEGF and IL-17 levels(P<0.05).Correlation analysis revealed a positive correlation between serum VEGF and IL-17(P<0.05).ROC analysis demonstrated that both serum VEGF and IL-17 had good diagnostic efficacy for PHC.CONCLUSION Serum VEGF and IL-17 levels were significantly higher in PHC patients compared to healthy individuals.Their levels were closely related to pathological features such as tumor metastasis and clinical TNM stage,and there was a significant positive correlation between VEGF and IL-17.These biomarkers may serve as valuable reference in-dicators for the early diagnosis and treatment guidance of PHC.
文摘Metabolic dysfunction-associated steatotic liver disease(MASLD),once known as non-alcoholic fatty liver disease(NAFLD),represents a spectrum of liver disorders characterized by lipid accumulation within hepatocytes.The redefinition of NAFLD in 2023 marked a significant reposition in terminology,emphasizing a broader understanding of liver steatosis and its associated risks.MASLD is now recognized as a major risk factor for liver cirrhosis,hepatocellular carcinoma,and systemic complications such as cardiovascular diseases or systemic inflammation.Diagnostic challenges arise,particularly in identifying MASLD in lean individuals,necessitating updated diagnostic protocols and investing in non-invasive diagnostic tools.Therapeutically,there is an urgent need for effective treatments targeting MASLD,with emerging pharmacological options focusing on,among others,carbohydrate and lipid metabolism.Additionally,understanding the roles of bile acid metabolism,the microbiome,and dietary interventions in MASLD pathogenesis and management holds promise for innovative therapeutic approaches.There is a strong need to emphasize the importance of collaborative efforts in understanding,diagnosing,and managing MASLD to improve physicians’approaches and patient outcomes.
基金supported by the National Magnetic Confinement Fusion Energy Program of China(No.2019YFE03020001)the Collaborative Innovation Program of Hefei Science Center,CAS(No.2021HSC-CIP010)the Fundamental Research Funds for the Central Universities。
文摘Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has been established that facilitates microwave imaging reflectometry and electron cyclotron emission imaging.This platform utilizes plasma profiles as input and incorporates the finite-difference time domain,ray tracing and the radiative transfer equation to calculate the propagation of plasma spontaneous radiation and the external electromagnetic field in plasmas.Benchmark tests for classical cases have been conducted to verify the accuracy of every core module in the GSD platform.Finally,2D imaging of a typical electron temperature distribution is reproduced by this platform and the results are consistent with the given real experimental data.This platform also has the potential to be extended to 3D electromagnetic field simulations and other microwave diagnostics such as cross-polarization scattering.
基金supported by National Natural Science Foundation of China(No.12175227)the Fundamental Research Funds for the Central Universities(No.USTC 20210079)the Collaborative Innovation Program of Hefei Science Center,CAS(No.2022HSC-CIP022)。
文摘A multi-channel polarimeter-interferometer has been developed on the Keda Torus eXperiment(KTX)for the study of equilibrium dynamics and internal magnetic fluctuations.A three-wave technique based on terahertz solid-state sources(-650 GHz)is applied for simultaneous measurements of electron density and Faraday rotation angle.The output power of the microwave source is 2 mW.Faraday rotation effect using a rotating wave plate is tested with phase noise less than 0.8°,and the density phase noise is less than 0.9°.Measurement of Faraday rotation angle and density for discharges on KTX have demonstrated high sensitivity to internal MHD activities.
文摘Inflammatory bowel diseases(IBDs),including Crohn's disease(CD)and ulcerative colitis,are chronic inflammatory conditions of the gastrointestinal tract that necessitate timely diagnosis to prevent complications and improve patient outcomes.Despite advancements in medical knowledge and diagnostic techniques,significant diagnostic delays persist,particularly in CD.The study by Blüthner et al,published in the World Journal of Gastroenterology,elucidates the diagnostic delays experienced by German patients with IBD and identifies key risk factors contributing to these delays.
文摘1) Background: Rapid and acurate diagnostic testing for case identification, quarantine, and contact tracing is essential for managing the COVID 19 pandemic. Rapid antigen detection tests are available, however, it is important to evaluate their performances before use. We tested a rapid antigen detection of SARS-CoV-2, based on the immunochromatography (Boson Biotech SARS-CoV-2 Ag Test (Xiamen Boson Biotech Co., Ltd., China)) and the results were compared with the real time reverse transcriptase-Polymerase chain reaction (RT-PCR) (Gold standard) results;2) Methods: From November 2021 to December 2021, samples were collected from symptomatic patients and asymptomatic individuals referred for testing in a hospital during the second pandemic wave in Gabon. All these participants attending “CTA Angondjé”, a field hospital set up as part of the management of COVID-19 in Gabon. Two nasopharyngeal swabs were collected in all the patients, one for Ag test and the other for RT-PCR;3) Results: A total of 300 samples were collected from 189 symptomatic and 111 asymptomatic individuals. The sensitivity and specificity of the antigen test were 82.5% [95%CI 73.8 - 89.3] and 97.9 % [95%CI 92.2 - 98.2] respectively, and the diagnostic accuracy was 84.4% (95% CI: 79.8 - 88.3%). The antigen test was more likely to be positive for samples with RT-PCR Ct values ≤ 32, with a sensitivity of 89.8%;4) Conclusions: The Boson Biotech SARS-CoV-2 Ag Test has good sensitivity and can detect SARS-CoV-2 infection, especially among symptomatic individuals with low viral load. This test could be incorporated into efficient testing algorithms as an alternative to PCR to decrease diagnostic delays and curb viral transmission.
基金supported by the National MCF Energy R&D Program of China (Nos. 2018YFE0302103 and 2018YFE 0302100)National Natural Science Foundation of China (Nos. 12205195 and 11975277)。
文摘To investigate the potential of utilizing visible spectral imaging for controlling the plasma boundary shape during stable operation of plasma in future tokamak, a D_α band symmetric visible light diagnostic system was designed and implemented on the Experimental Advanced Superconducting Tokamak(EAST). This system leverages two symmetric optics for joint plasma imaging. The optical system exhibits a spatial resolution less than 2 mm at the poloidal cross-section, distortion within the field of view below 10%, and relative illumination of 91%.The high-quality images obtained enable clear observation of both the plasma boundary position and the characteristics of components within the vacuum vessel. Following system calibration and coordinate transformation, the image coordinate boundary features are mapped to the tokamak coordinate system. Utilizing this system, the plasma boundary was reconstructed, and the resulting representation showed alignment with the EFIT(Equilibrium Fitting) results. This underscores the system's superior performance in boundary reconstruction applications and provides a diagnostic foundation for boundary shape control based on visible spectral imaging.
基金Supported by National Natural Science Foundation of China,No.81972696.
文摘BACKGROUND Hepatocellular carcinoma(HCC)is the third leading cause of cancer-related death worldwide.Serum biomarkers play an important role in the early diagnosis and prognosis of HCC.Because a certain percentage of HCC patients are negative for alpha-fetoprotein(AFP),the diagnosis of AFP-negative HCC is essential to improve the detection rate of HCC.AIM To establish an effective model for diagnosing AFP-negative HCC based on serum tumour biomarkers.METHODS A total of 180 HCC patients were enrolled in this study.The expression levels of GP73,des-γ-carboxyprothrombin(DCP),CK18-M65,and CK18-M30 were detected by a fully automated chemiluminescence analyser.The variables were selected by logistic regression analysis.Several models were constructed using stepwise backward logistic regression.The performance of the models was compared using the C statistic,integrated discrimination improvement,net reclassification improvement,and calibration curves.The clinical utility of the nomogram was assessed using decision curve analysis(DCA).RESULTS The results showed that the expression levels of GP73,DCP,CK18-M65,and CK18-M30 were significantly greater in AFP-negative HCC patients than in healthy controls(P<0.001).Multivariate logistic regression analysis revealed that GP73,DCP,and CK18-M65 were independent factors for diagnosing AFP-negative HCC.By comparing the diagnostic performance of multiple models,we included GP73 and CK18-M65 as the model variables,and the model had good discrimination ability(area under the curve=0.946)and good goodness of fit.The DCA curves indicated the good clinical utility of the nomogram.CONCLUSION Our study identified GP73 and CK18-M65 as serum biomarkers with certain application value in the diagnosis of AFP-negative HCC.The diagnostic nomogram based on CK18-M65 combined with GP73 demonstrated good performance and effectively identified high-risk groups of patients with HCC.
基金supported by the National MCF Energy R&D Program of China(Nos.2022YFE03040003 and 2019YFE03010003).
文摘Measurements of the total radiated power and its spatial distribution are crucial for fusion research.On the experimental advanced superconducting tokamak(EAST),both the metal foil resistive bolometer and the absolute extreme ultraviolet(AXUV)photodiodes have been used to quantify the radiated power.This article introduces the latest improvement of the bolometer diagnostic system on EAST.It also details the successful design and installation of new divertor AXUV cameras,which are dedicated to the investigation of divertor physics.The shielding components of the bolometer detector have been refined,and the article provides a detailed exposition of the double shielding structures that have been verified as effective in microwave shielding.Additionally,the changes in the radiated power distribution in the divertor region during the plasma detachment process are measured using the divertor AXUV camera.Finally,the radiated power measured by the AXUV detector and metal foil resistive bolometer are compared,and different detector performances are presented.