The long-path differential optical absorption spectroscopy (LP-DOAS) technique was developed to mea- sure nighttime atmospheric nitrate radical (NO3) concentrations. An optimized retrieval method, resulting in a s...The long-path differential optical absorption spectroscopy (LP-DOAS) technique was developed to mea- sure nighttime atmospheric nitrate radical (NO3) concentrations. An optimized retrieval method, resulting in a small residual structure and low detection limits, was developed to retrieve NO3. The time series of the NO3 concentration were collected from 17 to 24 March, 2006, where a nighttime average value of 15.8 ppt was observed. The interfering factors and errors are also discussed. These results indicate that the DOAS technique provides an essential tool for the quantification of NO3 concentration and in the study of its effects upon nighttime chemistry.展开更多
A CO_2 infrared remote sensing system based on the algorithm of weighting function modified differential optical absorption spectroscopy(WFM-DOAS) is developed for measuring CO_2 emissions from pollution sources. The ...A CO_2 infrared remote sensing system based on the algorithm of weighting function modified differential optical absorption spectroscopy(WFM-DOAS) is developed for measuring CO_2 emissions from pollution sources. The system is composed of a spectrometer with band from 900 nm to 1700 nm, a telescope with a field of view of 1.12?, a silica optical fiber, an automatic position adjuster, and the data acquisition and processing module. The performance is discussed,including the electronic noise of the charge-coupled device(CCD), the spectral shift, and detection limits. The resolution of the spectrometer is 0.4 nm, the detection limit is 8.5 × 10^(20)molecules·cm^(-2), and the relative retrieval error is < 1.5%.On May 26, 2018, a field experiment was performed to measure CO_2 emissions from the Feng-tai power plant, and a twodimensional distribution of CO_2 from the plume was obtained. The retrieved differential slant column densities(dSCDs)of CO_2 are around 2 × 10^(21) molecules·cm^(-2) in the unpolluted areas, 5.5 × 10^(21)molecules·cm^(-2) in the plume locations most strongly affected by local CO_2 emissions, and the fitting error is less than 2 × 10^(20)molecules·cm^(-2), which proves that the infrared remote sensing system has the characteristics of fast response and high precision, suitable for measuring CO_2 emission from the sources.展开更多
Differential optical absorption spectroscopy (DOAS) is a useful technique for measuring nitrogen dioxide (NO2) and aerosol, the most important species in urban environmental pollution. This paper reports on the result...Differential optical absorption spectroscopy (DOAS) is a useful technique for measuring nitrogen dioxide (NO2) and aerosol, the most important species in urban environmental pollution. This paper reports on the results of our dual path DOAS measurements recently conducted in Chiba City, Japan, using xenon flashlights equipped on tall constructions as aviation obstruction lights. Because of the proximity of the southern DOAS path to an industrial area, it is found that the level of air pollution generally increases with the dominance of westerly winds, from the plausible source area to the observation light path. This situation is consistent with the result of wind lidar measurement covering a sector of ±28? with the observation range of approximately 2.8 km. In spite of the fact that the two DOAS paths, having path lengths of 5.5 and 3.5 km each, are located in separated regions of Chiba City, the observed temporal behavior was similar for both nitrogen dioxide and aerosol, though the southern path tends to exhibit slightly higher pollution levels than the northern counterpart. Additionally it is confirmed that size information of aerosol particles can be derived from the DOAS data through the analysis of the wavelength dependence of the aerosol optical thickness, which shows fairly good correlation with the mass ratio between PM2.5 and suspended particulate matter (SPM) obtained from the in-situ sampling station measurement. Thus, the DOAS approach can also be utilized for obtaining information on PM2.5 that is considered to be more harmful to human health than SPM.展开更多
An airborne multi-axis differential optical absorption spectroscopic (AMAX-DOAS) instrument was developed and applied to measure tropospheric NO2 in the Pearl River Delta region in the south of China. By combining t...An airborne multi-axis differential optical absorption spectroscopic (AMAX-DOAS) instrument was developed and applied to measure tropospheric NO2 in the Pearl River Delta region in the south of China. By combining the measurements in nadir and zenith directions and analyzing the UV and visible spectral region using the DOAS method, information about tropospheric NO2 vertical columns was obtained. Strong tropospheric NO2 signals were detected when flying over heavilly polluted regions and point sources like plants. The AMAX-DOAS results were compared with ground-based MAX-DOAS observations in the southwest of Zhuhai city using the same parameters for radiative transport calculations. The difference in vertical column data between the two instruments is about 8%. Our data were also compared with those from OMI and fair agreement was obtained with a correlation coefficient R of 0.61. The difference between the two instruments can be attributed to the different spatial resolution and the temporal mismatch during the measurements.展开更多
A topographic target light scattering-differential optical absorption spectroscopy ('IbTaL-DOA~) system is de- veloped for measuring average concentrations along a known optical path and studying surface-near distr...A topographic target light scattering-differential optical absorption spectroscopy ('IbTaL-DOA~) system is de- veloped for measuring average concentrations along a known optical path and studying surface-near distributions of atmospheric trace gases. The telescope of the ToTaL-DOAS system points to targets which are located at known dis- tances from the measurement device and illuminated by sunlight. Average concentrations with high spatial resolution can be retrieved by receiving sunlight reflected from the targets, A filed measurement of NO2 concentration is performed with the ToTaL-DOAS system in Shijiazhuang in the autumn of 2011. The measurement data are compared with con- centrations measured by the point monitoring technique at the same site. The results show that the ToTaL-DOAS system is sensitive to the variation of NO2 concentrations along the optical path.展开更多
During the measurement of atmospheric nitrate radical by long-path differential optical absorption spectroscopy, water vapor strong absorption could affect the measurement of nitrate radical and detection limits of sy...During the measurement of atmospheric nitrate radical by long-path differential optical absorption spectroscopy, water vapor strong absorption could affect the measurement of nitrate radical and detection limits of system. Under the tropospheric condition, the optical density of water vapor absorption is non-linearly dependent on column density. An effective method was developed to eliminate the effect of water vapor absorption. Reference spectra of water vapor based on the daytime atmospheric absorption spectra, when fitted together with change of cross section with water vapor column densities, gave a more accurate fitting of water vapor absorptions, thus its effect on the measurements of nitrate radical could be restricted to a minimum and detection limits of system reached 3.6 ppt. The modified method was applied during an intensive field campaign in the Pearl River Delta, China. The NO3 concentration in polluted air masses varied from 3.6 ppt to 82.5 ppt with an average level of 23.6±1.8 ppt.展开更多
It was reported on the elimination of interfering absorption of BTX. the absorption of O2 includes different absorption bands, which change differently when the partial pressure of oxygen is varied. These cause the no...It was reported on the elimination of interfering absorption of BTX. the absorption of O2 includes different absorption bands, which change differently when the partial pressure of oxygen is varied. These cause the nonlinear absorption of O2 and the observed band shape to vary with the column density of O2. The absorption ratios of molecular absorption in each of the Herzberg bands and dimer absorptions, as well as the contribution to the correction error of molecular absorption, are studied based on the characteristic of these absorption bands. The optimized way to eliminate the interfering absorption is obtained in the end and the effectiveness of using interpolation proposed by Volkamer et al. to remove O2 absorption is proved again. As to O2 and SO2, the effect of the thermal effect of characteristic spectra on the elimination error of their absorption is studied. Solutions to these problems are discussed and demonstrated together with methods to optimize the interpolation of spectra. As a sample application, differential optical absorption spectroscopy (DOAS) measurements of BTX are carried out. Results show a low detection limit and the good correlation with point instruments are achieved. All these prove the feasibility of using spectral interpolation to improve the accuracy of DOAS measurements of aromatic hydrocarbons for practical purposes.展开更多
Measurements of atmospheric benzene and toluene were carried out continuously using dif- ferential optical absorption spectroscopy from August 7 to August 28 in Beijing during the period of vehicular restrictions. The...Measurements of atmospheric benzene and toluene were carried out continuously using dif- ferential optical absorption spectroscopy from August 7 to August 28 in Beijing during the period of vehicular restrictions. The correlations between traffic flows and totals of benzene and toluene were studied during the period of vehicular traffic restrictions from August 17 to August 20 and non-traffic restrictions on August 16 and August 21. The correlation coef- ficient was 0.8 between benzene and toluene. And the calculated daily mean value ratios of benzene to toluene were 0.43-0.50. During the period of vehicular restrictions, traffic flows were reduced about 11.8% and the levels of benzene and toluene were reduced by 11.4% and 12.8%, respectively. The vehicle emissions were recognized as the major sources for atmospheric benzene and toluene in Beijing.展开更多
文摘The long-path differential optical absorption spectroscopy (LP-DOAS) technique was developed to mea- sure nighttime atmospheric nitrate radical (NO3) concentrations. An optimized retrieval method, resulting in a small residual structure and low detection limits, was developed to retrieve NO3. The time series of the NO3 concentration were collected from 17 to 24 March, 2006, where a nighttime average value of 15.8 ppt was observed. The interfering factors and errors are also discussed. These results indicate that the DOAS technique provides an essential tool for the quantification of NO3 concentration and in the study of its effects upon nighttime chemistry.
基金Project supported by the Key Program of the National Natural Science Foundation of China(Grant No.41530644)
文摘A CO_2 infrared remote sensing system based on the algorithm of weighting function modified differential optical absorption spectroscopy(WFM-DOAS) is developed for measuring CO_2 emissions from pollution sources. The system is composed of a spectrometer with band from 900 nm to 1700 nm, a telescope with a field of view of 1.12?, a silica optical fiber, an automatic position adjuster, and the data acquisition and processing module. The performance is discussed,including the electronic noise of the charge-coupled device(CCD), the spectral shift, and detection limits. The resolution of the spectrometer is 0.4 nm, the detection limit is 8.5 × 10^(20)molecules·cm^(-2), and the relative retrieval error is < 1.5%.On May 26, 2018, a field experiment was performed to measure CO_2 emissions from the Feng-tai power plant, and a twodimensional distribution of CO_2 from the plume was obtained. The retrieved differential slant column densities(dSCDs)of CO_2 are around 2 × 10^(21) molecules·cm^(-2) in the unpolluted areas, 5.5 × 10^(21)molecules·cm^(-2) in the plume locations most strongly affected by local CO_2 emissions, and the fitting error is less than 2 × 10^(20)molecules·cm^(-2), which proves that the infrared remote sensing system has the characteristics of fast response and high precision, suitable for measuring CO_2 emission from the sources.
文摘Differential optical absorption spectroscopy (DOAS) is a useful technique for measuring nitrogen dioxide (NO2) and aerosol, the most important species in urban environmental pollution. This paper reports on the results of our dual path DOAS measurements recently conducted in Chiba City, Japan, using xenon flashlights equipped on tall constructions as aviation obstruction lights. Because of the proximity of the southern DOAS path to an industrial area, it is found that the level of air pollution generally increases with the dominance of westerly winds, from the plausible source area to the observation light path. This situation is consistent with the result of wind lidar measurement covering a sector of ±28? with the observation range of approximately 2.8 km. In spite of the fact that the two DOAS paths, having path lengths of 5.5 and 3.5 km each, are located in separated regions of Chiba City, the observed temporal behavior was similar for both nitrogen dioxide and aerosol, though the southern path tends to exhibit slightly higher pollution levels than the northern counterpart. Additionally it is confirmed that size information of aerosol particles can be derived from the DOAS data through the analysis of the wavelength dependence of the aerosol optical thickness, which shows fairly good correlation with the mass ratio between PM2.5 and suspended particulate matter (SPM) obtained from the in-situ sampling station measurement. Thus, the DOAS approach can also be utilized for obtaining information on PM2.5 that is considered to be more harmful to human health than SPM.
基金supported by the National Natural Science Foundation of China(Grant Nos.41275037,41275038,and 41275027)
文摘An airborne multi-axis differential optical absorption spectroscopic (AMAX-DOAS) instrument was developed and applied to measure tropospheric NO2 in the Pearl River Delta region in the south of China. By combining the measurements in nadir and zenith directions and analyzing the UV and visible spectral region using the DOAS method, information about tropospheric NO2 vertical columns was obtained. Strong tropospheric NO2 signals were detected when flying over heavilly polluted regions and point sources like plants. The AMAX-DOAS results were compared with ground-based MAX-DOAS observations in the southwest of Zhuhai city using the same parameters for radiative transport calculations. The difference in vertical column data between the two instruments is about 8%. Our data were also compared with those from OMI and fair agreement was obtained with a correlation coefficient R of 0.61. The difference between the two instruments can be attributed to the different spatial resolution and the temporal mismatch during the measurements.
基金Project supported by the National High Technology Research and Development of China (Grant No.2009AA063006)the National Natural Science Foundation of China (Grant No. 40905010)the Special Project of Environmental Nonprofit Industry Research,China (Grant No. 201109007)
文摘A topographic target light scattering-differential optical absorption spectroscopy ('IbTaL-DOA~) system is de- veloped for measuring average concentrations along a known optical path and studying surface-near distributions of atmospheric trace gases. The telescope of the ToTaL-DOAS system points to targets which are located at known dis- tances from the measurement device and illuminated by sunlight. Average concentrations with high spatial resolution can be retrieved by receiving sunlight reflected from the targets, A filed measurement of NO2 concentration is performed with the ToTaL-DOAS system in Shijiazhuang in the autumn of 2011. The measurement data are compared with con- centrations measured by the point monitoring technique at the same site. The results show that the ToTaL-DOAS system is sensitive to the variation of NO2 concentrations along the optical path.
文摘During the measurement of atmospheric nitrate radical by long-path differential optical absorption spectroscopy, water vapor strong absorption could affect the measurement of nitrate radical and detection limits of system. Under the tropospheric condition, the optical density of water vapor absorption is non-linearly dependent on column density. An effective method was developed to eliminate the effect of water vapor absorption. Reference spectra of water vapor based on the daytime atmospheric absorption spectra, when fitted together with change of cross section with water vapor column densities, gave a more accurate fitting of water vapor absorptions, thus its effect on the measurements of nitrate radical could be restricted to a minimum and detection limits of system reached 3.6 ppt. The modified method was applied during an intensive field campaign in the Pearl River Delta, China. The NO3 concentration in polluted air masses varied from 3.6 ppt to 82.5 ppt with an average level of 23.6±1.8 ppt.
基金This work was supported by the National Natural Science Foundation of China (No.20273066).
文摘It was reported on the elimination of interfering absorption of BTX. the absorption of O2 includes different absorption bands, which change differently when the partial pressure of oxygen is varied. These cause the nonlinear absorption of O2 and the observed band shape to vary with the column density of O2. The absorption ratios of molecular absorption in each of the Herzberg bands and dimer absorptions, as well as the contribution to the correction error of molecular absorption, are studied based on the characteristic of these absorption bands. The optimized way to eliminate the interfering absorption is obtained in the end and the effectiveness of using interpolation proposed by Volkamer et al. to remove O2 absorption is proved again. As to O2 and SO2, the effect of the thermal effect of characteristic spectra on the elimination error of their absorption is studied. Solutions to these problems are discussed and demonstrated together with methods to optimize the interpolation of spectra. As a sample application, differential optical absorption spectroscopy (DOAS) measurements of BTX are carried out. Results show a low detection limit and the good correlation with point instruments are achieved. All these prove the feasibility of using spectral interpolation to improve the accuracy of DOAS measurements of aromatic hydrocarbons for practical purposes.
文摘Measurements of atmospheric benzene and toluene were carried out continuously using dif- ferential optical absorption spectroscopy from August 7 to August 28 in Beijing during the period of vehicular restrictions. The correlations between traffic flows and totals of benzene and toluene were studied during the period of vehicular traffic restrictions from August 17 to August 20 and non-traffic restrictions on August 16 and August 21. The correlation coef- ficient was 0.8 between benzene and toluene. And the calculated daily mean value ratios of benzene to toluene were 0.43-0.50. During the period of vehicular restrictions, traffic flows were reduced about 11.8% and the levels of benzene and toluene were reduced by 11.4% and 12.8%, respectively. The vehicle emissions were recognized as the major sources for atmospheric benzene and toluene in Beijing.