This study was trying to observe the real-time dendrite growth of Sn-Bi and Sn-Pb binary alloys by a synchrotron radiation imaging technology.The imaging system includes an intense and high brightness synchrotron radi...This study was trying to observe the real-time dendrite growth of Sn-Bi and Sn-Pb binary alloys by a synchrotron radiation imaging technology.The imaging system includes an intense and high brightness synchrotron radiation source,a high-resolution and fast-readout charge coupled device camera,an alloy sample and a Bridgman solidification system.The imaging experiments were done at Beijing Synchrotron Radiation Facility with an updated synchrotron radiation imaging technique,diffraction-enhanced imaging,which was firstly used to study the dendrite growth of metallic alloy.A series of growth behavior and morphology evolution of dendrite have been in situ observed,such as columnar-to-equiaxed transition,dendrite competition,dendrite fragmentation and floating,etc.,which can offer the direct proofs to verify or improve the solidification theories of metallic alloy.This research opens a novel window for the study of alloy solidification and enables the unambiguous understanding of solidification processes in optically opaque,metallic alloys.展开更多
Diffraction enhanced imaging (DEI) with edge enhancement is suitable for the observation of weakly absorbing objects. The potential ability of the DEI was explored for displaying the microanatomy and pathology of hu...Diffraction enhanced imaging (DEI) with edge enhancement is suitable for the observation of weakly absorbing objects. The potential ability of the DEI was explored for displaying the microanatomy and pathology of human eyeball in this work. The images of surgical specimens from malignant intraocular tumor of hospitalized patients were taken using the hard X-rays from the topography station of Beamline 4W1A at Beijing Synchrotron Radiation Facility (BSRF). The obtained radiographic images were analyzed in correlation with those of pathology. The results show that the anatomic and pathologic details of intraocular tumors in human beings can be observed clearly by DEI for the first time, with good visualization of the microscopic details of eyeball ring such as sclera, choroids and other details of intraocular organelles. And the best resolution of DEI images reaches up to the magnitude of several tens of μm. The results suggest that it is capable of exhibiting clearly the details of intraocular tumor using DEI method.展开更多
Ductal carcinoma in-situ (DCIS) has been visualized by 2D XDFI (X-ray dark-field imaging) and further by a 3D X-ray CT, and the data was acquired by the X-ray optics DEI (diffraction-enhanced imaging). A newly made al...Ductal carcinoma in-situ (DCIS) has been visualized by 2D XDFI (X-ray dark-field imaging) and further by a 3D X-ray CT, and the data was acquired by the X-ray optics DEI (diffraction-enhanced imaging). A newly made algorithm was used for CT. Data of 900 projections with interval of 0.2 degrees were used. Ductus lactiferi, microcalci-fication in a 3D form have been clearly visible. The spatial resolution available was approximately 30μm.展开更多
A new method in diffraction-enhanced imaging computed tomography (DEI-CT) that follows the idea developed by Chapman et al. [Chapman D, Thomlinson W, Johnston R E, Washburn D, Pisano E, Gmur N, Zhong Z, Menk R, Arfe...A new method in diffraction-enhanced imaging computed tomography (DEI-CT) that follows the idea developed by Chapman et al. [Chapman D, Thomlinson W, Johnston R E, Washburn D, Pisano E, Gmur N, Zhong Z, Menk R, Arfelli F and Sayers D 1997 Phys. Med. BioL 42 2015] in 1997 is proposed in this paper. Merged with a "reverse projections" algorithm, only two sets of projection datasets at two defined orientations of the analyzer crystal are needed to reconstruct the linear absorption coefficient, the decrement of the real part of the refractive index and the linear scattering coefficient of the sample. Not only does this method reduce the delivered dose to the sample without degrading the image quality, but, compared with the existing DEI-CT approaches, it simplifies data-acquisition procedures. Experimental results confirm the reliability of this new method for DEI-CT applications.展开更多
基金supported by the National Natural Science Foundation of China (Grant Nos.50601003,50971032)the Program for New Century Excellent Talents in University (Grant No.NCET-07-0137)
文摘This study was trying to observe the real-time dendrite growth of Sn-Bi and Sn-Pb binary alloys by a synchrotron radiation imaging technology.The imaging system includes an intense and high brightness synchrotron radiation source,a high-resolution and fast-readout charge coupled device camera,an alloy sample and a Bridgman solidification system.The imaging experiments were done at Beijing Synchrotron Radiation Facility with an updated synchrotron radiation imaging technique,diffraction-enhanced imaging,which was firstly used to study the dendrite growth of metallic alloy.A series of growth behavior and morphology evolution of dendrite have been in situ observed,such as columnar-to-equiaxed transition,dendrite competition,dendrite fragmentation and floating,etc.,which can offer the direct proofs to verify or improve the solidification theories of metallic alloy.This research opens a novel window for the study of alloy solidification and enables the unambiguous understanding of solidification processes in optically opaque,metallic alloys.
基金Supported by National Natural Science Foundation (10490195)Key Project of Chinese National Programs for Fundamental Research and Development (973 program) (2006cb500700)Natural Science and Technology Foundation of Guangdong Province(04009356,2008B030301320)
文摘Diffraction enhanced imaging (DEI) with edge enhancement is suitable for the observation of weakly absorbing objects. The potential ability of the DEI was explored for displaying the microanatomy and pathology of human eyeball in this work. The images of surgical specimens from malignant intraocular tumor of hospitalized patients were taken using the hard X-rays from the topography station of Beamline 4W1A at Beijing Synchrotron Radiation Facility (BSRF). The obtained radiographic images were analyzed in correlation with those of pathology. The results show that the anatomic and pathologic details of intraocular tumors in human beings can be observed clearly by DEI for the first time, with good visualization of the microscopic details of eyeball ring such as sclera, choroids and other details of intraocular organelles. And the best resolution of DEI images reaches up to the magnitude of several tens of μm. The results suggest that it is capable of exhibiting clearly the details of intraocular tumor using DEI method.
文摘Ductal carcinoma in-situ (DCIS) has been visualized by 2D XDFI (X-ray dark-field imaging) and further by a 3D X-ray CT, and the data was acquired by the X-ray optics DEI (diffraction-enhanced imaging). A newly made algorithm was used for CT. Data of 900 projections with interval of 0.2 degrees were used. Ductus lactiferi, microcalci-fication in a 3D form have been clearly visible. The spatial resolution available was approximately 30μm.
基金Project supported by the National Basic Research Program of China(Grant No.2012CB825800)the National Natural Science Foundation of China(Grant Nos.11205189,11375225,and U1332109)the Knowledge Innovation Program of the Chinese Academy of Sciences(Grant Nos.KJCX2-YW-N42,Y4545320Y2,and 542014IHEPZZBS50659)
文摘A new method in diffraction-enhanced imaging computed tomography (DEI-CT) that follows the idea developed by Chapman et al. [Chapman D, Thomlinson W, Johnston R E, Washburn D, Pisano E, Gmur N, Zhong Z, Menk R, Arfelli F and Sayers D 1997 Phys. Med. BioL 42 2015] in 1997 is proposed in this paper. Merged with a "reverse projections" algorithm, only two sets of projection datasets at two defined orientations of the analyzer crystal are needed to reconstruct the linear absorption coefficient, the decrement of the real part of the refractive index and the linear scattering coefficient of the sample. Not only does this method reduce the delivered dose to the sample without degrading the image quality, but, compared with the existing DEI-CT approaches, it simplifies data-acquisition procedures. Experimental results confirm the reliability of this new method for DEI-CT applications.