Spherical aberrations of the thermal lens of the active media are severe when solid state lasers are strongly pumped. The fundamental mode profile deteriorates due to the aberrations. Self-consistent modes of a resona...Spherical aberrations of the thermal lens of the active media are severe when solid state lasers are strongly pumped. The fundamental mode profile deteriorates due to the aberrations. Self-consistent modes of a resonator with aberrations are calculated by using the Fox-Li diffraction iterative algorithm. Calculation results show that the aberration induced fundamental mode beam quality deterioration depends greatly on the resonator design. The tolerance of a flat-flat resonator to the aberration coefficient is about 30λ in the middle of stability, where λ is the wavelength of laser beam. But for a dynamically stable resonator, 2λ of spherical aberration will create diffraction loss of more than 40%, if inappropriate design criteria are used. A birefringence compensated laser resonator with two Nd:YAG rods is experimentally studied. The experimental data are in quite good agreement with simulation results.展开更多
A flat-topped etched diffraction grating (EDG) demultiplexer with a low polarization-dependent loss (PDL) is designed. A design and simulation method based on the method of moment (MoM) is proposed. A 65-channcl EDG d...A flat-topped etched diffraction grating (EDG) demultiplexer with a low polarization-dependent loss (PDL) is designed. A design and simulation method based on the method of moment (MoM) is proposed. A 65-channcl EDG demultiplexer with channel spacing of 100 GHz is considered as a design example. A tapered multi-mode interferometer (MMI) is used to flatten the passband of the EDG demultiplexer. The numerical results show that the exit width of the tapered waveguide impacts the loss of the TE case more than that of the TM case. Based on this fact, the exit width of the taper is optimized to obtain the lowest PDL. The tapering angle is also optimized where the minimal ripple is obtained. The designed EDG demultiplexer has an excellent flat-topped spectral response and a very low PDL.展开更多
基金Project supported by the National Natural Science Foundation-the Science Foundation of China Academy of Engineering Physics(NSAF) (Grant No 10876037)China Postdoctoral Science Foundation (Grant No 20080441238)
文摘Spherical aberrations of the thermal lens of the active media are severe when solid state lasers are strongly pumped. The fundamental mode profile deteriorates due to the aberrations. Self-consistent modes of a resonator with aberrations are calculated by using the Fox-Li diffraction iterative algorithm. Calculation results show that the aberration induced fundamental mode beam quality deterioration depends greatly on the resonator design. The tolerance of a flat-flat resonator to the aberration coefficient is about 30λ in the middle of stability, where λ is the wavelength of laser beam. But for a dynamically stable resonator, 2λ of spherical aberration will create diffraction loss of more than 40%, if inappropriate design criteria are used. A birefringence compensated laser resonator with two Nd:YAG rods is experimentally studied. The experimental data are in quite good agreement with simulation results.
基金This work was supported by the National Nat- ural Science Foundation of China under Grant No. 90101024 and 60377022.
文摘A flat-topped etched diffraction grating (EDG) demultiplexer with a low polarization-dependent loss (PDL) is designed. A design and simulation method based on the method of moment (MoM) is proposed. A 65-channcl EDG demultiplexer with channel spacing of 100 GHz is considered as a design example. A tapered multi-mode interferometer (MMI) is used to flatten the passband of the EDG demultiplexer. The numerical results show that the exit width of the tapered waveguide impacts the loss of the TE case more than that of the TM case. Based on this fact, the exit width of the taper is optimized to obtain the lowest PDL. The tapering angle is also optimized where the minimal ripple is obtained. The designed EDG demultiplexer has an excellent flat-topped spectral response and a very low PDL.