期刊文献+
共找到16篇文章
< 1 >
每页显示 20 50 100
Digital measuring the ocular morphological parameters of guinea pig eye in vivo with Python
1
作者 Yue Di Zhong-Bao Qiao +4 位作者 Hai-Yun Ye Xin-Yue Li Wen-Ting Luo Wang-Yi Fang Tong Qiao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期239-246,共8页
AIM:To quantitatively measure ocular morphological parameters of guinea pig with Python technology.METHODS:Thirty-six eyeballs of eighteen 3-weekold guinea pigs were measured with keratometer and photographed to obtai... AIM:To quantitatively measure ocular morphological parameters of guinea pig with Python technology.METHODS:Thirty-six eyeballs of eighteen 3-weekold guinea pigs were measured with keratometer and photographed to obtain the horizontal,coronal,and sagittal planes respectively.The corresponding photo pixels-actual length ratio was acquired by a proportional scale.The edge coordinates were identified artificially by ginput function.Circle and conic curve fitting were applied to fit the contour of the eyeball in the sagittal,coronal and horizontal view.The curvature,curvature radius,eccentricity,tilt angle,corneal diameter,and binocular separation angle were calculated according to the geometric principles.Next,the eyeballs were removed,canny edge detection was applied to identify the contour of eyeball in vitro.The results were compared between in vivo and in vitro.RESULTS:Regarding the corneal curvature and curvature radius on the horizontal and sagittal planes,no significant differences were observed among results in vivo,in vitro,and the keratometer.The horizontal and vertical binocular separation angles were 130.6°±6.39°and 129.8°±9.58°respectively.For the corneal curvature radius and eccentricity in vivo,significant differences were observed between horizontal and vertical planes.CONCLUSION:The Graphical interface window of Python makes up the deficiency of edge detection,which requires too much definition in Matlab.There are significant differences between guinea pig and human beings,such as exotropic eye position,oblique oval eyeball,and obvious discrepancy of binoculus.This study helps evaluate objectively the ocular morphological parameters of small experimental animals in emmetropization research. 展开更多
关键词 ocular morphological parameters guinea pig digital measurement PYTHON
下载PDF
A pilot study of the precision of digital intraocular pressure measurement during vitrectomy
2
作者 Can-Can Xue Shu-Shan Li +3 位作者 Jin-Hong Miao Se-Fei Wu Xue-Ling Tian Chun Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第10期1574-1579,共6页
AIM:To evaluate the precision of digital intraocular pressure(IOP)measurement in silicone oil(SO)filled eyes during vitrectomy.METHODS:This is a retrospective,single-blind study.Patients who were diagnosed with retina... AIM:To evaluate the precision of digital intraocular pressure(IOP)measurement in silicone oil(SO)filled eyes during vitrectomy.METHODS:This is a retrospective,single-blind study.Patients who were diagnosed with retinal detachment and scheduled for vitrectomy with SO injection were consecutively enrolled.During the vitrectomy,IOP was digitally measured and then by a rebound tonometer(Icare PRO).The rebound tonometer readings were masked to the surgeons.The digitally measured IOP and that of rebound tonometer were compared,and the inter-methods agreement was assessed.The absolute deviation in IOP values between these two methods(△IOP)was also calculated,and correlations between△IOP and refractive status,lens status and levels of surgeons’experience were analyzed.RESULTS:A total of 131 patients(131 eyes)were recruited,with a mean age of 51.0±16.1 y.There was no significant difference in IOPs between digital measurement and the rebound tonometer(15.6±4.3 vs 15.7±5.1 mm Hg;t=0.406,P=0.686).Intraclass correlation coefficients(ICC)analysis indicated a strong correlation between these two measurements(ICC=0.830,P<0.001).The mean△IOP was 2.0±1.9 mm Hg(range:0-12.8 mm Hg),with 98 eyes(74.8%)had the△IOP within 3 mm Hg.△IOP was found to be negatively correlated with levels of surgeons’experience(r=-0.183;P=0.037),but not with the refractive status or lens status of the patients(both P>0.05).CONCLUSION:For experienced surgeons,the digital IOP measurement may be an acceptable technique for IOP measurement in SO filled eyes during vitrectomy.However,its use by inexperienced surgeons should be taken with caution. 展开更多
关键词 digital intraocular pressure measurement intraocular pressure silicone oil VITRECTOMY
下载PDF
Spectral Measurement of Atmospheric Pressure Plasma by Means of Digital Camera
3
作者 葛袁静 张广秋 +1 位作者 刘益民 赵志发 《Plasma Science and Technology》 SCIE EI CAS CSCD 2002年第1期1107-1112,共6页
A digital camera measuring system has been used successfully to measure the space fluctuation behaviors of Induced Dielectric Barrier Discharge (IDBD) plasma at atmospheric pres- sure. The experimental results showed ... A digital camera measuring system has been used successfully to measure the space fluctuation behaviors of Induced Dielectric Barrier Discharge (IDBD) plasma at atmospheric pres- sure. The experimental results showed that: (1) The uniformity of electron temperature in space depends on discharge condition and structure of web electrode. For a certain web electrode the higher the discharge voltage is, the more uniform distribution of electron temperature in space will be. For a certain discharge the finer and denser the holes on web electrode are, the more uniform distribution of electron temperature in space will be (2). Digital camera is an available equipment to measure some behaviors of the plasma working at atmospheric pressure. 展开更多
关键词 Spectral measurement of Atmospheric Pressure Plasma by Means of digital Camera
下载PDF
Digital measurement of bone tumor volume by CT three-dimensional reconstruction technology
4
作者 胡永成 《外科研究与新技术》 2011年第2期125-125,共1页
Objective To discuss the measurement of bone tumor volume on the basis of three dimensional images segmentation technology. Methods Twenty patients with lacunar bone tumor from Tianjin Hospital and Tongji Hospital wer... Objective To discuss the measurement of bone tumor volume on the basis of three dimensional images segmentation technology. Methods Twenty patients with lacunar bone tumor from Tianjin Hospital and Tongji Hospital were included in the 展开更多
关键词 BONE digital measurement of bone tumor volume by CT three-dimensional reconstruction technology CT
下载PDF
A convenient look-up-table based method for the compensation of non-linear error in digital fringe projection 被引量:9
5
作者 Chen Xiong Jun Yao +1 位作者 Jubing Chen Hong Miao 《Theoretical & Applied Mechanics Letters》 CAS CSCD 2016年第1期49-53,共5页
Although the structured light system that uses digital fringe projection has been widely implemented in three-dimensional surface profile measurement, the measurement system is susceptible to non-linear error. In this... Although the structured light system that uses digital fringe projection has been widely implemented in three-dimensional surface profile measurement, the measurement system is susceptible to non-linear error. In this work, we propose a convenient look-up-table-based (LUT-based) method to compensate for the non-linear error in captured fringe patterns. Without extra calibration, this LUT-based method completely utilizes the captured fringe pattern by recording the full-field differences. Then, a phase compensation map is established to revise the measured phase. Experimental results demonstrate that this method works effectively. 展开更多
关键词 Phase measurement digital fringe projection Non-linear error compensation digital image processing
下载PDF
Subset-based local vs.finite element-based global digital image correlation:A comparison study 被引量:2
6
作者 Bo Wang Bing Pan 《Theoretical & Applied Mechanics Letters》 CAS CSCD 2016年第5期200-208,共9页
Being the two primary approaches for full-field kinematics measurements, both subset-based local digital image correlation (DIC) and finite element-based global DIC have been extensively studied. Nowadays, most comm... Being the two primary approaches for full-field kinematics measurements, both subset-based local digital image correlation (DIC) and finite element-based global DIC have been extensively studied. Nowadays, most commercial DIC systems employ local DIC algorithm because of its advantages of straight forward principle and higher efficiency. However, several researchers argue that global DIC can provide better displacement results due to the displacement continuity constraint among adjacent elements. As such, thoroughly examining the performance of these two different DIC methods seems to be highly necessary. Here, the random errors associated with local DIC and two global DIC methods are theoretically analyzed at first. Subsequently, based on the same algorithmic details and parameters during analyses of numerical and real experiments, the performance of the different DIC approaches is fairly compared. Theoretical and experimental results reveal that local DIC outperforms its global counterpart in terms of both displacement results and computational efficiency when element (subset) size is no less than 11 pixels. 展开更多
关键词 digital image correlation Displacement measurement Finite element Subset Subpixel
下载PDF
Application of Digital Image Correlation and Geodetic Displacement Measuring Methods to Monitor Water Dam Behavior under Dynamic Load
7
作者 Janina Zaczek-Peplinska Maria Elzbieta Kowalska +1 位作者 Krzysztof Malowany MarcinMalesa 《Journal of Civil Engineering and Architecture》 2015年第12期1496-1505,共10页
This paper presents experiment results of the measurement conducted at the Roznew Dam power plant. For a course of starting and operating of turbo-plants, downstream face of the dam was monitored in relation to its ev... This paper presents experiment results of the measurement conducted at the Roznew Dam power plant. For a course of starting and operating of turbo-plants, downstream face of the dam was monitored in relation to its eventual displacements on direction parallel to the construction axis. For the purpose of the experiment, geodetic measurement techniques and 2D DIC (digital image correlation) method (utilizing photographs of the object recorded with digital camera) were compared with regard to credibility, efficiency and accuracy. The vertical and horizontal displacements were monitored by tachometers measurements. The deformations in x-axis and y-axis on the wall surface was monitored by 2D DIC. It has been noticed that 2D DIC method is a surface method, continuous--not discreet. It allows for continuous observations of surface deformations, which is not possible in case of tachemetric measurements. Despite many advantages, the 2D DIC method lacks unambiguous evaluation of precision and relevance of designated displacements, which is rather significant for possibilities of utilization in technical control of large engineered objects. It should be also marked that the tachometric method is more reliable but is more laborious. Research of this type might comprise additional element for the assessment of the influence of dynamic loads, such as activating turbine water flow, onto the overall condition of the surveyed structure. 展开更多
关键词 Hydrotechnical structure structure dynamic load engineering object displacement geodetic displacement measurements.digital image correlation.
下载PDF
Employment of predictive search algorithm in digital image correlation
8
作者 马志峰 王昊 韩福海 《Journal of Beijing Institute of Technology》 EI CAS 2014年第2期254-259,共6页
A predictive search algorithm to estimate the size and direction of displacement vectors was presented.The algorithm decreased the time of calculating the displacement of each pixel.In addition,the updating reference ... A predictive search algorithm to estimate the size and direction of displacement vectors was presented.The algorithm decreased the time of calculating the displacement of each pixel.In addition,the updating reference image scheme was used to update the reference image and to decrease the computation time when the displacement was larger than a certain number.In this way,the search range and computational complexity were cut down,and less EMS memory was occupied.The capability of proposed search algorithm was then verified by the results of both computer simulation and experiments.The results showed that the algorithm could improve the efficiency of correlation method and satisfy the accuracy requirement for practical displacement measuring. 展开更多
关键词 machine vision predictive search algorithm digital image correlation sub-pixel displacement measurement
下载PDF
Influence of Temperature Probes Installation on the Salient Pole to Temperature Measurement
9
作者 Z. Hanic M. Kovacic M. Vrazic 《Journal of Energy and Power Engineering》 2011年第8期776-784,共9页
Accurate and reliable information about the temperature of the synchronous generators excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram.... Accurate and reliable information about the temperature of the synchronous generators excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram. For good estimation of a position and the hot spot temperature it is decided to mount 19 temperature probes on one pole of the 6-pole, 400 kVA. 50 llz synchronous generator. Due to a large number of the probes and because the probes should be glued with the metal epoxy it was assumed that mounting of the probes will disrupt the temperature field of the excitation winding. To get the answer to this question the excitation winding resistance was measured betbre and after mounting the probes, in a hot and a cold state. Temperature rise can be estimated if the resistance ratio in the hot and the cold state is known. The paper also addresses the analysis of the measurement accuracy. The result shows that, there is no significant influence on the temperature when mounting the 19 temperature probes which covered 10% of the pole excitation winding surface. 展开更多
关键词 Temperature measurement AC generators rotating machine measurements excitation winding thermal probes digital measurements measurement accuracy measurement errors.
下载PDF
Measurement of in-plane deformations of microsystems by digital holography and speckle interferometry(Invited Paper) 被引量:1
10
作者 G. Pedrini J. Gaspar +1 位作者 O. Paul W. Osten 《Chinese Optics Letters》 SCIE EI CAS CSCD 2009年第12期1109-1112,共4页
The reliability of microsystems is an important issue and for their quality inspection, it is necessary to know the displacements or deformations due to the applied mechanical, thermal, or electrostatic loads. We show... The reliability of microsystems is an important issue and for their quality inspection, it is necessary to know the displacements or deformations due to the applied mechanical, thermal, or electrostatic loads. We show how interferometrical techniques like digital holography and speckle interferometry can be used for the measurement of in plane deformations of microsystems with nanometric accuracy and we give a description of the measurement uncertainties. 展开更多
关键词 Invited Paper measurement of in-plane deformations of microsystems by digital holography and speckle interferometry
原文传递
Advances in shape measurement in the digital world 被引量:1
11
作者 Xiaodong Jia Edward J. Garboczi 《Particuology》 SCIE EI CAS CSCD 2016年第3期19-31,共13页
The importance of particle shape in terms of its effects on the behaviour of powders and other particulate systems has long been recognised, but particle shape information has been rather difficult to obtain and use u... The importance of particle shape in terms of its effects on the behaviour of powders and other particulate systems has long been recognised, but particle shape information has been rather difficult to obtain and use until fairly recently, unlike its better-known counterpart, particle size. However, advances in computing power and 3D image acquisition and analysis techniques have resulted in major progress being made in the measurement, description and application of particle shape information in recent years. Because we are now in a digital era, it is fitting that many of these advanced techniques are based on digital technology. This review article aims to trace the development of these new techniques, highlight their contributions to both academic and practical applications, and present a perspective for future developments. 展开更多
关键词 Particle shape digital methods Shape measurement Spherical harmonics X-ray tomography
原文传递
Measurement of out-of-plane deformation of curved objects with digital speckle pattern interferometry 被引量:1
12
作者 Pengfei Li Ping Cai +2 位作者 Jun Long Chiyue Liu Hao Yan 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第11期40-46,共7页
Digital speckle pattern interferometry (DSPI) is a high-precision deformation t technique for planar objects. However, for curved objects, the three-dimensional (3D) shape information is needed in order to obtain ... Digital speckle pattern interferometry (DSPI) is a high-precision deformation t technique for planar objects. However, for curved objects, the three-dimensional (3D) shape information is needed in order to obtain correct deformation measurement in DSPI. Thus, combined shape and deformation measurement techniques of DSPI have been proposed. However, the current techniques are either complex in setup or complicated in operation. Furthermore, the operations of some techniques are too slow for real-time measurement. In this work, we propose a DSPI technique for both 3D shape and out-of-plane deformation measurement. Compared with current techniques, the proposed technique is simple in both setup and operation and is capable of fast deformation measurement. Theoretical analysis and experiments are performed. For a cylinder surface with an arch height of 9 mm, the error of out-of-plane deformation measurement is less than 0.15 μm. The effectiveness of the proposed scheme is verified. 展开更多
关键词 measurement of out-of-plane deformation of curved objects with digital speckle pattern interferometry
原文传递
Geospatial Information Service Based on Digital Measurable Image——Take Image City·Wuhan as an Example 被引量:4
13
作者 LI Deren SHEN Xin 《Geo-Spatial Information Science》 2010年第2期79-84,共6页
t LBS (location-based service) is a remarkable outcome of the development from GIS to geospatial information service. Faced by the requirements of geospatial information from the masses and the opportunity provided ... t LBS (location-based service) is a remarkable outcome of the development from GIS to geospatial information service. Faced by the requirements of geospatial information from the masses and the opportunity provided by the next generation lnternet and Web 2.0, a new model of geospatial information service based on DMI (digital measurable image) is presented. First, the con- cept of LBS and the opportunities of Web 2.0 are introduced, then the characteristic of DMI is discussed. Taking the Image City.Wuhan as an example, the function ofgeospatial information service based on DM! is introduced. Finally, the feasibility for its industrialization is discussed. 展开更多
关键词 location-based service digital measurable image geospatial information service
原文传递
High-precision method for measuring the photothermal properties of transparent media with digital holography
14
作者 David C.Clark Myung K.Kim 《Chinese Optics Letters》 SCIE EI CAS CSCD 2011年第12期2-5,共4页
Quantitative phase microscopy by digital holography provides direct access to the phase profile of a transparent subject with high precision. This is useful for observing phenomena that modulate phase, but are otherwi... Quantitative phase microscopy by digital holography provides direct access to the phase profile of a transparent subject with high precision. This is useful for observing phenomena that modulate phase, but are otherwise difficult or impossible to detect. In this letter, a carefully constructed digital holographic apparatus is used to measure optically induced thermal lensing with an optical path difference precision of less than 1 nm. Furthermore, by taking advantage of the radial symmetry of a thermal lens, such data are processed to determine the absorption coefficient of transparent media with precisions as low as 1 × 10-5cm-1 using low power (30 mW) continuous wave (CW) excitation. 展开更多
关键词 High-precision method for measuring the photothermal properties of transparent media with digital holography
原文传递
The new era for geo-information 被引量:11
15
作者 LI DeRen SHAO ZhenFeng 《Science in China(Series F)》 2009年第7期1233-1242,共10页
Along with the forthcoming of Google Earth, Virtual Earth, the next generation of Internet, Web 2.0, grid computing and smart sensor web, comes the new era for geo-information. In this paper, main features of new geo-... Along with the forthcoming of Google Earth, Virtual Earth, the next generation of Internet, Web 2.0, grid computing and smart sensor web, comes the new era for geo-information. In this paper, main features of new geo-information era are discussed. This new era is characterized by these features: serviced users are extended from professionals to all public users, the users are data and information providers as well, geospatial data provided are no longer measurement-by-specification but measurement-on- demand through smart sensor web, and services are transferred from being data-driven to application- driven. Such problems as out-of-order issues in geographic data collection and information prolifer- ation, quality issues in geographic information updating, security issues in geographic information services, privacy issues in sharing geographic information and property issues in sharing geographic information, which are brought about by new geo-information era, especially those confronted in geo- information science and geo-spatial information industry, are analyzed. Then strategies concerning standards, planning, laws, technology and applications are proposed. 展开更多
关键词 new geo-information era geo-services digital measurable image service-on-demand sensor web
原文传递
Experimental and numerical study on structural performance of reinforced concrete box sewer with localized extreme defect 被引量:1
16
作者 Yuequan Bao Dongyang Feng +2 位作者 Nan Ma Hehua Zhu Timon Rabczuk 《Underground Space》 SCIE EI 2018年第2期166-179,共14页
An experimental and numerical investigation into the structural performance of reinforced concrete box sewers with typical corrosion-related extreme defects localized at the ceiling was conducted.Firstly,during the la... An experimental and numerical investigation into the structural performance of reinforced concrete box sewers with typical corrosion-related extreme defects localized at the ceiling was conducted.Firstly,during the large-scale laboratory test,some key struc-tural responses were captured and evaluated,including the crack width development process(via digital image correlation measurement),ceiling deflection,and material strains of both complete and typical defective boxes.The failure modes and load-carrying mechanism throughout the specimen loading phases were analyzed.Furthermore,the specimen failure process was simulated using a damage-basedfinite element method,and a related parameter sensitivity analysis was performed.The results indicate that the defective ceiling cracked at mid-span under a low load value,but the bending capacity loss can be substituted by two shoulders and carry three tofive times more load before completely collapsing.The simulation matched the lab test qualitatively,and with the suggested set strategy of material parameters,the load-deflection feature curve could provide a practical prediction of the ultimate bearing capacity of the defec-tive sewers,with a 10–15%error on the safe side. 展开更多
关键词 Defective reinforced concrete box sewer Corrosion Structural performance Large-scale model test digital image correlation measurement Failure simulation
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部