DC LOOP-CURRENT DETECTING AND RESTRAINING METHODS FOR PARALLEL INVERTER SYSTEM
1
作者 陈良亮 肖岚 严仰光 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2004年第1期1-6,共6页
DC component is contained in inverter output voltage due to many reasons such as the zero-point deviation of operational amplifiers and the differences between power switching transistors′ characteristics. For the pa... DC component is contained in inverter output voltage due to many reasons such as the zero-point deviation of operational amplifiers and the differences between power switching transistors′ characteristics. For the parallel inverter system without output isolation transformers, the difference of DC components of the output voltage can cause large DC loop-current among modular inverters. Aiming at this problem, this paper studies several DC loop-current detecting and restraining methods. By digital adjustment with high precision on the DC components of reference sine wave, the DC components of inverter′s output voltage can be adjusted to restrain DC loop-current. Experimental results prove that the DC loop-current detecting and restraining methods have a good performance. 展开更多
关键词 DC loop-current DETECT digital adjustment parallel inverter