期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Establishing a Customized Guide Plate for Osteotomy in Total Knee Arthroplasty Using Lower-extremity X-ray and Knee Computed Tomography Images 被引量:4
1
作者 Jin Zhang Xiao-Bin Tian +4 位作者 Li Sun Ru-Yin Hu Jia-Liang Tian Wei Han Jin-Min Zhao 《Chinese Medical Journal》 SCIE CAS CSCD 2016年第4期386-391,共6页
Background: The conventional method cannot guarantee the precise osteotomies required for a perfect realignment and a better prognosis after total knee arthroplasty (TKA).This study investigated a customized guide ... Background: The conventional method cannot guarantee the precise osteotomies required for a perfect realignment and a better prognosis after total knee arthroplasty (TKA).This study investigated a customized guide plate for osteotomy placement in TKAs with the aid of the statistical shape model technique using weight-bearing lower-extremity X-rays and computed tomography (CT) images of the knee.Methods: From October 2014 to June 2015, 42 patients who underwent a TKA in Guizhou Provincial People&#39;s Hospital were divided into a guide plate group (GPG, 21 cases) and a traditional surgery group (TSG, 21 cases) using a random number table method.In the GPG group, a guide plate was designed and printed using preoperative three-dimensional measurements to plan and digitally simulate the operation.TSG cases were treated with the conventional method.Outcomes were obtained from the postoperative image examination and short-term follow-up.Results: Operative time was 49.0 &#177; 10.5 min for GPG, and 62.0 &#177; 9.7 min in TSG.The coronal femoral angle, coronal tibial angle, posterior tibial slope, and the angle between the posterior condylar osteotomy surface and the surgical transepicondylar axis were 89.2 &#177; 1.7&#176;, 89.0 &#177; 1.1&#176;, 6.6 &#177; 1.4&#176;, and 0.9 &#177; 0.3&#176; in GPG, and 86.7 &#177; 2.9&#176;, 87.6 &#177; 2.1&#176;, 8.9 &#177; 2.8&#176;, and 1.7 &#177; 0.8&#176; in TSG, respectively.The Hospital for Special Surgery scores 3 months after surgery were 83.7 &#177; 18.4 in GPG and 71.5 &#177; 15.2 in TSG.Statistically significant differences were found between GPG and TSG in all measurements.Conclusions: A customized guide plate to create an accurate osteotomy in TKAs may be created using lower-extremity X-ray and knee CT images.This allows for shorter operative times and better postoperative alignment than the traditional surgery.Application of the digital guide plate may also result in better short-term outcomes. 展开更多
关键词 digital guide plate for Osteotomy Lower-extremity X-ray Statistical Shape Model Total Knee Arthroplasty
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部