In this paper,an irregular displacement-based lensless wide-field microscopy imaging platform is presented by combining digital in-line holography and computational pixel super-resolution using multi-frame processing....In this paper,an irregular displacement-based lensless wide-field microscopy imaging platform is presented by combining digital in-line holography and computational pixel super-resolution using multi-frame processing.The samples are illuminated by a nearly coherent illumination system,where the hologram shadows are projected into a complementary metal-oxide semiconductor-based imaging sensor.To increase the resolution,a multi-frame pixel resolution approach is employed to produce a single holographic image from multiple frame observations of the scene,with small planar displacements.Displacements are resolved by a hybrid approach:(i)alignment of the LR images by a fast feature-based registration method,and(ii)fine adjustment of the sub-pixel information using a continuous optimization approach designed to find the global optimum solution.Numerical method for phase-retrieval is applied to decode the signal and reconstruct the morphological details of the analyzed sample.The presented approach was evaluated with various biological samples including sperm and platelets,whose dimensions are in the order of a few microns.The obtained results demonstrate a spatial resolution of 1.55 μm on a field-of-view of<30 mm^(2).展开更多
The experiments were conducted to focus on the desulfurization and evaporation characteristics of lime slurry droplets at 298-383 K. We designed an evaporation-reaction chamber with quartz glass windows.The monodisper...The experiments were conducted to focus on the desulfurization and evaporation characteristics of lime slurry droplets at 298-383 K. We designed an evaporation-reaction chamber with quartz glass windows.The monodisperse slurry droplet stream was injected into the evaporation reaction chamber, and the inlet gas components(air, air + SO_(2)) were introduced into the chamber. We applied the magnified digital in-line holography to measure the droplet parameters and calculated the evaporation rate. The effects of temperature, droplet concentration, and SO_(2) concentration on the evaporation rate of Ca(OH)_(2) droplets were discussed. Moreover, the Ca(OH)_(2) droplets under different experimental conditions were sampled,and the droplets were observed and analyzed using an off-line microscope. The evaporation rate of the Ca(OH)_(2) droplet increased at first, and then decreased during the falling process, and remained constant at last. The average evaporation rate of the Ca(OH)_(2) droplets increased significantly with the temperature increasing.展开更多
基金We would like to acknowledge National Institute of Health(NIH)NIH R01AI093282,NIH R01AI081534,NIH U54EB15408,NIH R21AI087107,and Brigham and Women’s Hospital-BRI Translatable Technologies and Care Innovation GrantWe would also like to acknowledge the support provided by the Brazilian National Council for Scientific and Technological Development(process 551967/2011-0)
文摘In this paper,an irregular displacement-based lensless wide-field microscopy imaging platform is presented by combining digital in-line holography and computational pixel super-resolution using multi-frame processing.The samples are illuminated by a nearly coherent illumination system,where the hologram shadows are projected into a complementary metal-oxide semiconductor-based imaging sensor.To increase the resolution,a multi-frame pixel resolution approach is employed to produce a single holographic image from multiple frame observations of the scene,with small planar displacements.Displacements are resolved by a hybrid approach:(i)alignment of the LR images by a fast feature-based registration method,and(ii)fine adjustment of the sub-pixel information using a continuous optimization approach designed to find the global optimum solution.Numerical method for phase-retrieval is applied to decode the signal and reconstruct the morphological details of the analyzed sample.The presented approach was evaluated with various biological samples including sperm and platelets,whose dimensions are in the order of a few microns.The obtained results demonstrate a spatial resolution of 1.55 μm on a field-of-view of<30 mm^(2).
基金supported by the National Natural Science Fund for Distinguished Young Scholars (No. 51825605)。
文摘The experiments were conducted to focus on the desulfurization and evaporation characteristics of lime slurry droplets at 298-383 K. We designed an evaporation-reaction chamber with quartz glass windows.The monodisperse slurry droplet stream was injected into the evaporation reaction chamber, and the inlet gas components(air, air + SO_(2)) were introduced into the chamber. We applied the magnified digital in-line holography to measure the droplet parameters and calculated the evaporation rate. The effects of temperature, droplet concentration, and SO_(2) concentration on the evaporation rate of Ca(OH)_(2) droplets were discussed. Moreover, the Ca(OH)_(2) droplets under different experimental conditions were sampled,and the droplets were observed and analyzed using an off-line microscope. The evaporation rate of the Ca(OH)_(2) droplet increased at first, and then decreased during the falling process, and remained constant at last. The average evaporation rate of the Ca(OH)_(2) droplets increased significantly with the temperature increasing.