Greater complexity and interconnectivity across systems embracing electrical power technologies has meant that cyber-security issues have attracted significant attention. In this paper a simulation environment for int...Greater complexity and interconnectivity across systems embracing electrical power technologies has meant that cyber-security issues have attracted significant attention. In this paper a simulation environment for intrusion detection system in IEC 61850 standard-based substation automation system is provided to test simulated attacks on IEDs (intelligent electronic devices). Intrusion detection is the process of detecting malicious attacker, so it is an effective and mature security mechanism to protect electrical facility. However, it is not harnessed when securing IEC 61850 automated substation. To prove the detection capability of the system testing environment was developed to analyze and test attacks simulated with different test cases. It shows that the simulation environment works accordingly to various network traffic scenarios and eventually proves the functionality of intrusion detection system to be later deployed in the real IEC 61850 based substation automation system site.展开更多
IEC 61850 allows the replacement of conventional wire based systems to communication based system with local area network. Since new engineering processes are introduced in substation, the specifications and tools are...IEC 61850 allows the replacement of conventional wire based systems to communication based system with local area network. Since new engineering processes are introduced in substation, the specifications and tools are required combined with new skills across the substation engineering. In order to construct the IEC 61850 based substation automation system, the IED engineering tools as an engineering means are necessary to cope with the substation automation by full digital devices in the real power systems. Compared the configuration tools provided IEDs vendors which are able to support the operation and communication analysis between IEDs, the XML based IED integration engineering tools as substation engineering tools which are developed can build, edit and save the ICD, SCL and CID files. Particularly, the substation engineering tools are possible to apply the IEC 61850 based IEDs for the engineering process of systems and also provide the reliability and efficiency of system for the utilities and manufacturers. The developed tools are applied to test and create the SCL files for domestic-made IEDs, and then compared with the conventional tools. The reliability including accuracy of results was proved.展开更多
The IEC 61850 standard stipulates the Substation Configuration Description Language (SCL) file as a means to define the substation equipment, IED function and also the communication mechanism for the substation area n...The IEC 61850 standard stipulates the Substation Configuration Description Language (SCL) file as a means to define the substation equipment, IED function and also the communication mechanism for the substation area network. The SCL is an eXtensible Markup Language (XML) based file which helps to describe the configuration of the substation Intelligent Electronic Devices (IED) including their associated functions. The SCL file is also configured to contain all IED capabilities including data model which is structured into objects for easy descriptive modeling. The effective functioning of this SCL file relies on appropriate validation techniques which check the data model for errors due to non-conformity to the IEC 61850 standard. In this research, we extend the conventional SCL validation algorithm to develop a more advanced validator which can validate the standard data model using the Unified Modeling Language (UML). By using the Rule-based SCL validation tool, we implement validation test cases for a more comprehensive understanding of the various validation functionalities. It can be observed from the algorithm and the various implemented test cases that the proposed validation tool can improve SCL information validation and also help automation engineers to comprehend the IEC 61850 substation system architecture.展开更多
The problem of logical node(LN)importance quantification in an IEC 61850 based substation automation system(SAS)is investigated in this paper.First,a weighted and directed static complex network model is established b...The problem of logical node(LN)importance quantification in an IEC 61850 based substation automation system(SAS)is investigated in this paper.First,a weighted and directed static complex network model is established by analyzing the characteristics of SAS,according to IEC 61850.Then,we propose a method,which combines topology value and information adjunction value by introducing a first-order linear feedback controller to quantify the value of LNs.On this basis,some definitions for equivalent network conversion are proposed to greatly reduce the complexity of the original network topology.Also,the absolute value and relative value are introduced to quantify LN importance from the perspective of the node’s necessity and influence,respectively.Finally,simulation results of the case study demonstrate that the proposed method is effective and provides a broader and clearer perspective for viewing the logical node importance for IEC61850 based SAS.展开更多
International standards are being developed to promote rapid configuration and integration into the utility automation system. In order to take advantage of modern technology to provide new benefits to users of substa...International standards are being developed to promote rapid configuration and integration into the utility automation system. In order to take advantage of modern technology to provide new benefits to users of substation automation, the International Electrotechnical Commission (IEC) has developed and released a new global standard for substation automation, named IEC 61850. This aim of this paper is to provide a basic technical overview of substation automation and the standard IEC 61850. It will discuss the benefits of each major aspect of this standard and it will describe how these concepts can be used in the development and implementation of tools related to Substation Automation. The application of communication standards and protocols to facilitate data exchange within the substation environment is presented. In addition, the model is implemented using a small distribution system that plans to utilize new communication technology following the IEC 61850 standard. Finally it proposes a set of laboratories to be used as the core of an undergraduate course. Results illustrate that the communication approach as proposed by IEC 61850 fulfills the real-time requirements for control and protection of distribution system.展开更多
Globally, traditional power systems are rapidly transforming towards the adoption of smart grid platforms. Substations which are at the center of the electric power transformation from the power plant are changing to ...Globally, traditional power systems are rapidly transforming towards the adoption of smart grid platforms. Substations which are at the center of the electric power transformation from the power plant are changing to IEC 61850 based digital substations. Therefore, within substation, there is a growing demand for the IEC 61850 based Intelligent Electronic Devices (IEDs). The operation of multiple manufacturers of IEDs in a single digital substation network increases the need for IEC 61850 communications specification conformance diagnosis to ensure interoperability for efficient data exchange between IEDs. The IEC 61850-10 presents test items for diagnosing communication specification conformance. There are many test tools available in the market today to test the compliance of the IEC 61850 communications specifications to the IED. In this paper, we propose a model-based diagnostic method for IED communication conformance testing. The proposed model-based software therefore uses the “drag and drop” technique to select the various IEC 61850 communication services (objects) required to design the test case in a user friendly Graphical User Interface (GUI). This makes the service conformance testing more flexible for test engineers and system integrators especially in situations that require test case modifications. Also, the proposed software tool makes it easy to understand the various IEC 61850 services using the friendly GUI.展开更多
Korea Electric Power Corporation in charge of the power IT project "Development of Prototype for Advanced Substation Automation System based on the Digital Control Technology", is performing the verification of perf...Korea Electric Power Corporation in charge of the power IT project "Development of Prototype for Advanced Substation Automation System based on the Digital Control Technology", is performing the verification of performance of the substation automation system based on IEC 61850. In order to verify a transformer protective lED that might be operating in substation automation system, the new standardized document and procedures are required in the aspect of the utility like KEPCO. But there is nothing to describe systematically how to verify IEC 6 1850 based lED in the system environment except an individual IED testing way. This paper will present the substation automation system based ways and procedures to verify the protective function of the IED using UML (Unified Modeling Language).展开更多
文摘Greater complexity and interconnectivity across systems embracing electrical power technologies has meant that cyber-security issues have attracted significant attention. In this paper a simulation environment for intrusion detection system in IEC 61850 standard-based substation automation system is provided to test simulated attacks on IEDs (intelligent electronic devices). Intrusion detection is the process of detecting malicious attacker, so it is an effective and mature security mechanism to protect electrical facility. However, it is not harnessed when securing IEC 61850 automated substation. To prove the detection capability of the system testing environment was developed to analyze and test attacks simulated with different test cases. It shows that the simulation environment works accordingly to various network traffic scenarios and eventually proves the functionality of intrusion detection system to be later deployed in the real IEC 61850 based substation automation system site.
文摘IEC 61850 allows the replacement of conventional wire based systems to communication based system with local area network. Since new engineering processes are introduced in substation, the specifications and tools are required combined with new skills across the substation engineering. In order to construct the IEC 61850 based substation automation system, the IED engineering tools as an engineering means are necessary to cope with the substation automation by full digital devices in the real power systems. Compared the configuration tools provided IEDs vendors which are able to support the operation and communication analysis between IEDs, the XML based IED integration engineering tools as substation engineering tools which are developed can build, edit and save the ICD, SCL and CID files. Particularly, the substation engineering tools are possible to apply the IEC 61850 based IEDs for the engineering process of systems and also provide the reliability and efficiency of system for the utilities and manufacturers. The developed tools are applied to test and create the SCL files for domestic-made IEDs, and then compared with the conventional tools. The reliability including accuracy of results was proved.
文摘The IEC 61850 standard stipulates the Substation Configuration Description Language (SCL) file as a means to define the substation equipment, IED function and also the communication mechanism for the substation area network. The SCL is an eXtensible Markup Language (XML) based file which helps to describe the configuration of the substation Intelligent Electronic Devices (IED) including their associated functions. The SCL file is also configured to contain all IED capabilities including data model which is structured into objects for easy descriptive modeling. The effective functioning of this SCL file relies on appropriate validation techniques which check the data model for errors due to non-conformity to the IEC 61850 standard. In this research, we extend the conventional SCL validation algorithm to develop a more advanced validator which can validate the standard data model using the Unified Modeling Language (UML). By using the Rule-based SCL validation tool, we implement validation test cases for a more comprehensive understanding of the various validation functionalities. It can be observed from the algorithm and the various implemented test cases that the proposed validation tool can improve SCL information validation and also help automation engineers to comprehend the IEC 61850 substation system architecture.
基金This work was supported in part by the National Natural Science Foundation of China(U1866209)。
文摘The problem of logical node(LN)importance quantification in an IEC 61850 based substation automation system(SAS)is investigated in this paper.First,a weighted and directed static complex network model is established by analyzing the characteristics of SAS,according to IEC 61850.Then,we propose a method,which combines topology value and information adjunction value by introducing a first-order linear feedback controller to quantify the value of LNs.On this basis,some definitions for equivalent network conversion are proposed to greatly reduce the complexity of the original network topology.Also,the absolute value and relative value are introduced to quantify LN importance from the perspective of the node’s necessity and influence,respectively.Finally,simulation results of the case study demonstrate that the proposed method is effective and provides a broader and clearer perspective for viewing the logical node importance for IEC61850 based SAS.
文摘International standards are being developed to promote rapid configuration and integration into the utility automation system. In order to take advantage of modern technology to provide new benefits to users of substation automation, the International Electrotechnical Commission (IEC) has developed and released a new global standard for substation automation, named IEC 61850. This aim of this paper is to provide a basic technical overview of substation automation and the standard IEC 61850. It will discuss the benefits of each major aspect of this standard and it will describe how these concepts can be used in the development and implementation of tools related to Substation Automation. The application of communication standards and protocols to facilitate data exchange within the substation environment is presented. In addition, the model is implemented using a small distribution system that plans to utilize new communication technology following the IEC 61850 standard. Finally it proposes a set of laboratories to be used as the core of an undergraduate course. Results illustrate that the communication approach as proposed by IEC 61850 fulfills the real-time requirements for control and protection of distribution system.
文摘Globally, traditional power systems are rapidly transforming towards the adoption of smart grid platforms. Substations which are at the center of the electric power transformation from the power plant are changing to IEC 61850 based digital substations. Therefore, within substation, there is a growing demand for the IEC 61850 based Intelligent Electronic Devices (IEDs). The operation of multiple manufacturers of IEDs in a single digital substation network increases the need for IEC 61850 communications specification conformance diagnosis to ensure interoperability for efficient data exchange between IEDs. The IEC 61850-10 presents test items for diagnosing communication specification conformance. There are many test tools available in the market today to test the compliance of the IEC 61850 communications specifications to the IED. In this paper, we propose a model-based diagnostic method for IED communication conformance testing. The proposed model-based software therefore uses the “drag and drop” technique to select the various IEC 61850 communication services (objects) required to design the test case in a user friendly Graphical User Interface (GUI). This makes the service conformance testing more flexible for test engineers and system integrators especially in situations that require test case modifications. Also, the proposed software tool makes it easy to understand the various IEC 61850 services using the friendly GUI.
文摘Korea Electric Power Corporation in charge of the power IT project "Development of Prototype for Advanced Substation Automation System based on the Digital Control Technology", is performing the verification of performance of the substation automation system based on IEC 61850. In order to verify a transformer protective lED that might be operating in substation automation system, the new standardized document and procedures are required in the aspect of the utility like KEPCO. But there is nothing to describe systematically how to verify IEC 6 1850 based lED in the system environment except an individual IED testing way. This paper will present the substation automation system based ways and procedures to verify the protective function of the IED using UML (Unified Modeling Language).