Microwave ablation(MWA) is a cancer treatment method. The tumor tissue absorbs electromagnetic energy, which heats and kills it. A microwave ablation antenna plays a critical role in this process. Its radiation field ...Microwave ablation(MWA) is a cancer treatment method. The tumor tissue absorbs electromagnetic energy, which heats and kills it. A microwave ablation antenna plays a critical role in this process. Its radiation field must completely cover the tumor but not the healthy tissue. At present, the radiation pattern of most invasive ablation antennas is spherical.However, in the clinic, the shape of some tumors may be asymmetrical or the antenna cannot be inserted into the center of the tumor for some other reason. In order to solve these problems, a directional heating antenna for microwave ablation is proposed in this paper. The proposed antenna, operating at 2.45 GHz, consists of a monopole and a reflector. The feed is given by a substrate integrated coaxial line(SICL) and coplanar waveguide(CPW). The omnidirectional radiation field of the monopole is reflected by a reflector that is extended from the outer conductors of the SICL to form a directional radiation field. The impedance matching network is designed on SICL to match the antenna to 50 Ω. The antenna is fabricated using a mature printed circuit board(PCB). The reflection coefficient of the antenna in porcine liver tissue measured by a vector network analyzer shows good agreement with the simulations. Then, an ablation experiment in porcine liver is conducted with power of 10 W for 10 min, and the experimental results confirm the validity of the design.展开更多
For the sake of a more accurate shell boundary and calculation of radiation heat transfer in the Directional Solidification(DS) process, a radiation heat transfer model based on the Finite Element Method(FEM)is develo...For the sake of a more accurate shell boundary and calculation of radiation heat transfer in the Directional Solidification(DS) process, a radiation heat transfer model based on the Finite Element Method(FEM)is developed in this study. Key technologies, such as distinguishing boundaries automatically, local matrix and lumped heat capacity matrix, are also stated. In order to analyze the effect of withdrawing rate on DS process,the solidification processes of a complex superalloy turbine blade in the High Rate Solidification(HRS) process with different withdrawing rates are simulated; and by comparing the simulation results, it is found that the most suitable withdrawing rate is determined to be 5.0 mm·min^(-1). Finally, the accuracy and reliability of the radiation heat transfer model are verified, because of the accordance of simulation results with practical process.展开更多
Direct Expansion Ground Source Heat Pump (DXGSHP) system directly extracts heat or cold energy from ground by consuming electricity to provide for space conditioning. Compared with the currently widely-used secondary ...Direct Expansion Ground Source Heat Pump (DXGSHP) system directly extracts heat or cold energy from ground by consuming electricity to provide for space conditioning. Compared with the currently widely-used secondary loop Ground Couple Heat Pump (GCHP) system, it has higher energy efficiency, lower operating costs, and less environmental impact. A case study is carried out in this paper. The subject is a residential building located in Beijing, China. It is assumed that the building adopts the DXGSHP system and the GCHP system respectively. Annual loads and energy consumption are simulated and computed. Then the initial cost, operating cost and CO2 emission are calculated. The economic benefit is analyzed with the Payback Time method and the Dynamic Annual Cost Value method. The environmental benefit is discussed mainly by comparing the CO2 emission savings. The results show that the DXGSHP system has higher initial costs, but lower operating costs, and less greenhouse gas emissions. The DXGSHP system has better comprehensive benefits than the GCHP system.展开更多
Direct expansion solar assisted heat pump (DX-SAHP) technology is developed by combining solar energy heat utilization with heat pump energy saving technology. The experimental researches of the DX-SAHP hot water syst...Direct expansion solar assisted heat pump (DX-SAHP) technology is developed by combining solar energy heat utilization with heat pump energy saving technology. The experimental researches of the DX-SAHP hot water system are conducted in this paper, and overall performance of DX-SAHP is analyzed with three different structures of collectors/evaporators, namely a bare-plate collector, a glass-plate collector and double collectors/evaporators (a bare-plate collector and a glass-plate collector). The influence factors and overall performance are studied, which show that the overall performance of the system is mainly influenced by solar irradiation intensity and the collector area. Comparing with glass-plate collector in similar conditions, bare-plate collector system COP is higher. While increasing collector area is conducive to improve the system COP, but will reduce the collector efficiency and increase the workload of the compressor by comparing the bare-plate collector with double-plate collectors.展开更多
HFO-1234yf and HFO-1234ze[E] have low global warming potential and zero ozone depletion potential. If they are used in the direct expansion ground source heat pump system substituting for HFC-134a, the system will be ...HFO-1234yf and HFO-1234ze[E] have low global warming potential and zero ozone depletion potential. If they are used in the direct expansion ground source heat pump system substituting for HFC-134a, the system will be beneficial to mitigating climate change. This study aims to find out the thermodynamic characteristics of the direct expansion ground source heat pump system using HFO-1234yf or HFO-1234ze[E] by theoretical calculation. The results indicate that HFO-1234yf system in an actual cycle has the highest COP. HFO-1234yf and HFO-1234ze[E] have such smaller capacity per unit of swept volume that they need larger compression capacity if providing the same heating or cooling loads. For a given unit when HFC-134a is replaced with HFO-1234yf or HFO-1234ze[E], the capacity will decrease. More refrigerant charge is required in the HFO-1234yf or HFO-1234ze[E] system. The results also present that more refrigerant charge is required in the cooling mode than in the heating mode.展开更多
High-quality solidification microstructure during directional solidification relies on precise temperature gradient control, so accurate calculation of the temperature field is critical. In this study, a 3D transient ...High-quality solidification microstructure during directional solidification relies on precise temperature gradient control, so accurate calculation of the temperature field is critical. In this study, a 3D transient global heat transfer model of directional solidification by the Bridgman method based on the finite difference method is developed. The radiation heat in this model is calculated by the discrete transfer method, and a modified method of external surface area for irregular geometric models is proposed to reduce the zigzag shape caused by finite difference grids. Considering the radiative heat transfer between any surface elements of all materials in the directional solidification furnace, a dynamic ray tracing algorithm is developed to simulate the entire process of directional solidification. Then, the simulated results are compared with the theoretical results and experimental results, respectively. Finally, based on the present model and method, the simulation program developed is applied to the directional solidification of actual castings. The simulated results are in good agreement with the experimental results, which indicate that the model and method developed in this study is effective and practical.展开更多
The model of transient behavior of semiconductor with heat-conduction is an initial and boundary problem. Alternating-direction multistep preconditioned iterative methods and theory analyses are given in this paper. E...The model of transient behavior of semiconductor with heat-conduction is an initial and boundary problem. Alternating-direction multistep preconditioned iterative methods and theory analyses are given in this paper. Electric potential equation is approximated by mixed finite element method, concentration and heat-conduction equations are approximated by Galerkin alternating-direction multistep methods. Error estimates of optimal order in L2 are demonstrated.展开更多
We conducted a transient experimental investigation of steam–water direct contact condensation in the absence of noncondensible gas in a laboratory-scale column with the inner diameter of 325 mm and the height of 104...We conducted a transient experimental investigation of steam–water direct contact condensation in the absence of noncondensible gas in a laboratory-scale column with the inner diameter of 325 mm and the height of 1045 mm. We applied a new analysis method for the steam state equation to analyze the molar quantity change in steam over the course of the experiment and determined the transient steam variation. We also investigated the influence of flow rates and temperatures ofcooling water on the efficiency ofsteam condensation. Our experimental results show that appropriate increasing of the cooling water flow rate can significantly accelerate the steam condensation. We achieved a rapid increase in the total volumetric heat transfer coefficient by increasing the flow rate of cooling water, which indicated a higher thermal convection between the steam and the cooling water with higher flow rates. We found that the temperature ofcooling water did not play an important role on steam condensation. This method was confirmed to be effective for rapid recovering ofsteam.展开更多
Our previous experimental studies have confirmed that viscoelastic-fluid-based nanofluid(VFBN) prepared by suspending nanoparticles in a viscoelastic base fluid(VBF, behaves drag reduction at turbulent flow state) can...Our previous experimental studies have confirmed that viscoelastic-fluid-based nanofluid(VFBN) prepared by suspending nanoparticles in a viscoelastic base fluid(VBF, behaves drag reduction at turbulent flow state) can reduce turbulent flow resistance as compared with water and enhance heat transfer as compared with VBF. Direct numerical simulation(DNS) is performed in this study to explore the mechanisms of heat transfer enhancement(HTE) and flow drag reduction(DR) for the VFBN turbulent flow. The Giesekus model is used as the constitutive equation for VFBN. Our previously proposed thermal dispersion model is adopted to take into account the thermal dispersion effects of nanoparticles in the VFBN turbulent flow. The DNS results show similar behaviors for flow resistance and heat transfer to those obtained in our previous experiments. Detailed analyses are conducted for the turbulent velocity, temperature, and conformation fields obtained by DNSs for different fluid cases, and for the friction factor with viscous, turbulent, and elastic contributions and heat transfer rate with conductive, turbulent and thermal dispersion contributions of nanoparticles, respectively. The mechanisms of HTE and DR of VFBN turbulent flows are then discussed. Based on analogy theory, the ratios of Chilton–Colburn factor to friction factor for different fluid flow cases are investigated, which from another aspect show the significant enhancement in heat transfer performance for some cases of water-based nanofluid and VFBN turbulent flows.展开更多
A circulating fluidized bed evaporator(including down-flow, horizontal, and up-flow beds) was constructed to study the effect of flow directions on multiphase flow boiling heat transfer. A range of experimental invest...A circulating fluidized bed evaporator(including down-flow, horizontal, and up-flow beds) was constructed to study the effect of flow directions on multiphase flow boiling heat transfer. A range of experimental investigations were carried out by varying amount of added particles(0-2%), circulation flow rate(2.15-5.16 m^3/h) and heat flux(8-16 kW/m^2). The comparison of heat transfer performance in different vertical heights of the horizontal bed was also discussed. Results reveal that the glass bead particle can enhance heat transfer compared with vapor-liquid two-phase flow for all beds. At a low heat flux(q = 8 kW/m), the heat-transfer-enhancing factor of the horizontal bed is obviously greater than those of the up-flow and down-flow beds. With the increase in the amount of added particles, the heat-transfer-enhancing factors of the up-flow and down-flow beds increase, whereas that of the horizontal bed initially increases and then decreases. However, at a high heat flux(q=16 kW/m), the heat-transfer-enhancing factors of the three beds show an increasing tendency with the increase in the amount of added particles and become closer than those at a low heat flux. For all beds, the heat-transfer-enhancing factor generally increases with the circulation flow rate but decreases with the increase in heat flux.展开更多
基金Project supported by the National Natural Science Foundation of China (Grant No. U1966201)the Fundamental Research Funds for the Central Universities, China (Grant No. A03019023801224)。
文摘Microwave ablation(MWA) is a cancer treatment method. The tumor tissue absorbs electromagnetic energy, which heats and kills it. A microwave ablation antenna plays a critical role in this process. Its radiation field must completely cover the tumor but not the healthy tissue. At present, the radiation pattern of most invasive ablation antennas is spherical.However, in the clinic, the shape of some tumors may be asymmetrical or the antenna cannot be inserted into the center of the tumor for some other reason. In order to solve these problems, a directional heating antenna for microwave ablation is proposed in this paper. The proposed antenna, operating at 2.45 GHz, consists of a monopole and a reflector. The feed is given by a substrate integrated coaxial line(SICL) and coplanar waveguide(CPW). The omnidirectional radiation field of the monopole is reflected by a reflector that is extended from the outer conductors of the SICL to form a directional radiation field. The impedance matching network is designed on SICL to match the antenna to 50 Ω. The antenna is fabricated using a mature printed circuit board(PCB). The reflection coefficient of the antenna in porcine liver tissue measured by a vector network analyzer shows good agreement with the simulations. Then, an ablation experiment in porcine liver is conducted with power of 10 W for 10 min, and the experimental results confirm the validity of the design.
基金financially supported by the Program for New Century Excellent Talents in University(No.NCET-13-0229,NCET-09-0396)the National Science & Technology Key Projects of Numerical Control(No.2012ZX04010-031,2012ZX0412-011)the National High Technology Research and Development Program("863"Program)of China(No.2013031003)
文摘For the sake of a more accurate shell boundary and calculation of radiation heat transfer in the Directional Solidification(DS) process, a radiation heat transfer model based on the Finite Element Method(FEM)is developed in this study. Key technologies, such as distinguishing boundaries automatically, local matrix and lumped heat capacity matrix, are also stated. In order to analyze the effect of withdrawing rate on DS process,the solidification processes of a complex superalloy turbine blade in the High Rate Solidification(HRS) process with different withdrawing rates are simulated; and by comparing the simulation results, it is found that the most suitable withdrawing rate is determined to be 5.0 mm·min^(-1). Finally, the accuracy and reliability of the radiation heat transfer model are verified, because of the accordance of simulation results with practical process.
文摘Direct Expansion Ground Source Heat Pump (DXGSHP) system directly extracts heat or cold energy from ground by consuming electricity to provide for space conditioning. Compared with the currently widely-used secondary loop Ground Couple Heat Pump (GCHP) system, it has higher energy efficiency, lower operating costs, and less environmental impact. A case study is carried out in this paper. The subject is a residential building located in Beijing, China. It is assumed that the building adopts the DXGSHP system and the GCHP system respectively. Annual loads and energy consumption are simulated and computed. Then the initial cost, operating cost and CO2 emission are calculated. The economic benefit is analyzed with the Payback Time method and the Dynamic Annual Cost Value method. The environmental benefit is discussed mainly by comparing the CO2 emission savings. The results show that the DXGSHP system has higher initial costs, but lower operating costs, and less greenhouse gas emissions. The DXGSHP system has better comprehensive benefits than the GCHP system.
文摘Direct expansion solar assisted heat pump (DX-SAHP) technology is developed by combining solar energy heat utilization with heat pump energy saving technology. The experimental researches of the DX-SAHP hot water system are conducted in this paper, and overall performance of DX-SAHP is analyzed with three different structures of collectors/evaporators, namely a bare-plate collector, a glass-plate collector and double collectors/evaporators (a bare-plate collector and a glass-plate collector). The influence factors and overall performance are studied, which show that the overall performance of the system is mainly influenced by solar irradiation intensity and the collector area. Comparing with glass-plate collector in similar conditions, bare-plate collector system COP is higher. While increasing collector area is conducive to improve the system COP, but will reduce the collector efficiency and increase the workload of the compressor by comparing the bare-plate collector with double-plate collectors.
文摘HFO-1234yf and HFO-1234ze[E] have low global warming potential and zero ozone depletion potential. If they are used in the direct expansion ground source heat pump system substituting for HFC-134a, the system will be beneficial to mitigating climate change. This study aims to find out the thermodynamic characteristics of the direct expansion ground source heat pump system using HFO-1234yf or HFO-1234ze[E] by theoretical calculation. The results indicate that HFO-1234yf system in an actual cycle has the highest COP. HFO-1234yf and HFO-1234ze[E] have such smaller capacity per unit of swept volume that they need larger compression capacity if providing the same heating or cooling loads. For a given unit when HFC-134a is replaced with HFO-1234yf or HFO-1234ze[E], the capacity will decrease. More refrigerant charge is required in the HFO-1234yf or HFO-1234ze[E] system. The results also present that more refrigerant charge is required in the cooling mode than in the heating mode.
基金financially supported by the National Nature Science Fund Projects of China(Nos.51475181 and 51605174)
文摘High-quality solidification microstructure during directional solidification relies on precise temperature gradient control, so accurate calculation of the temperature field is critical. In this study, a 3D transient global heat transfer model of directional solidification by the Bridgman method based on the finite difference method is developed. The radiation heat in this model is calculated by the discrete transfer method, and a modified method of external surface area for irregular geometric models is proposed to reduce the zigzag shape caused by finite difference grids. Considering the radiative heat transfer between any surface elements of all materials in the directional solidification furnace, a dynamic ray tracing algorithm is developed to simulate the entire process of directional solidification. Then, the simulated results are compared with the theoretical results and experimental results, respectively. Finally, based on the present model and method, the simulation program developed is applied to the directional solidification of actual castings. The simulated results are in good agreement with the experimental results, which indicate that the model and method developed in this study is effective and practical.
基金This research was surpported by the National Natural Science Foundation , Mathematical TY Foun-dation (TY10126029) of China and the Youth Foundation of Shandong University.
文摘The model of transient behavior of semiconductor with heat-conduction is an initial and boundary problem. Alternating-direction multistep preconditioned iterative methods and theory analyses are given in this paper. Electric potential equation is approximated by mixed finite element method, concentration and heat-conduction equations are approximated by Galerkin alternating-direction multistep methods. Error estimates of optimal order in L2 are demonstrated.
文摘We conducted a transient experimental investigation of steam–water direct contact condensation in the absence of noncondensible gas in a laboratory-scale column with the inner diameter of 325 mm and the height of 1045 mm. We applied a new analysis method for the steam state equation to analyze the molar quantity change in steam over the course of the experiment and determined the transient steam variation. We also investigated the influence of flow rates and temperatures ofcooling water on the efficiency ofsteam condensation. Our experimental results show that appropriate increasing of the cooling water flow rate can significantly accelerate the steam condensation. We achieved a rapid increase in the total volumetric heat transfer coefficient by increasing the flow rate of cooling water, which indicated a higher thermal convection between the steam and the cooling water with higher flow rates. We found that the temperature ofcooling water did not play an important role on steam condensation. This method was confirmed to be effective for rapid recovering ofsteam.
基金supported by the National Natural Science Foundation of China(Grant No.51276046)the Specialized Research Fund for the Doctoral Program of Higher Education of China(Grant No.20112302110020)+1 种基金the China Postdoctoral Science Foundation(Grant No.2014M561037)the President Fund of University of Chinese Academy of Sciences,China(Grant No.Y3510213N00)
文摘Our previous experimental studies have confirmed that viscoelastic-fluid-based nanofluid(VFBN) prepared by suspending nanoparticles in a viscoelastic base fluid(VBF, behaves drag reduction at turbulent flow state) can reduce turbulent flow resistance as compared with water and enhance heat transfer as compared with VBF. Direct numerical simulation(DNS) is performed in this study to explore the mechanisms of heat transfer enhancement(HTE) and flow drag reduction(DR) for the VFBN turbulent flow. The Giesekus model is used as the constitutive equation for VFBN. Our previously proposed thermal dispersion model is adopted to take into account the thermal dispersion effects of nanoparticles in the VFBN turbulent flow. The DNS results show similar behaviors for flow resistance and heat transfer to those obtained in our previous experiments. Detailed analyses are conducted for the turbulent velocity, temperature, and conformation fields obtained by DNSs for different fluid cases, and for the friction factor with viscous, turbulent, and elastic contributions and heat transfer rate with conductive, turbulent and thermal dispersion contributions of nanoparticles, respectively. The mechanisms of HTE and DR of VFBN turbulent flows are then discussed. Based on analogy theory, the ratios of Chilton–Colburn factor to friction factor for different fluid flow cases are investigated, which from another aspect show the significant enhancement in heat transfer performance for some cases of water-based nanofluid and VFBN turbulent flows.
基金supported by Tianjin Municipal Science and Technology Commission, China (No. 2009ZCKFGX01900)
文摘A circulating fluidized bed evaporator(including down-flow, horizontal, and up-flow beds) was constructed to study the effect of flow directions on multiphase flow boiling heat transfer. A range of experimental investigations were carried out by varying amount of added particles(0-2%), circulation flow rate(2.15-5.16 m^3/h) and heat flux(8-16 kW/m^2). The comparison of heat transfer performance in different vertical heights of the horizontal bed was also discussed. Results reveal that the glass bead particle can enhance heat transfer compared with vapor-liquid two-phase flow for all beds. At a low heat flux(q = 8 kW/m), the heat-transfer-enhancing factor of the horizontal bed is obviously greater than those of the up-flow and down-flow beds. With the increase in the amount of added particles, the heat-transfer-enhancing factors of the up-flow and down-flow beds increase, whereas that of the horizontal bed initially increases and then decreases. However, at a high heat flux(q=16 kW/m), the heat-transfer-enhancing factors of the three beds show an increasing tendency with the increase in the amount of added particles and become closer than those at a low heat flux. For all beds, the heat-transfer-enhancing factor generally increases with the circulation flow rate but decreases with the increase in heat flux.