Given the distribution feature of resources such as coal and water, the requirements for the development of Chinese power industry, and the fact of monopoly by foreign companies, it is very necessary and significant t...Given the distribution feature of resources such as coal and water, the requirements for the development of Chinese power industry, and the fact of monopoly by foreign companies, it is very necessary and significant to independently research and develop air-cooling technologies. Through experimental research, simulative calculation, process and equipment development, field tests and a demonstration project, the design and operation technologies for air-cooling system are grasped and relevant key equipment is developed. The results of the demonstration project show that the technical indicators for the air-cooling system have met or exceeded the design requirements. Part of the research results have been incorporated into the relevant national design standards. The technologies developed have been applied to more than 23 sets of thermal power units of or above 600 MW in China.展开更多
The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit ...The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2.展开更多
In order to get thermal flow field of direct air-cooled system,the hot water was supplied to the model of direct air-cooled condenser(ACC). The particle image velocimetery (PIV) experiments were carried out to get the...In order to get thermal flow field of direct air-cooled system,the hot water was supplied to the model of direct air-cooled condenser(ACC). The particle image velocimetery (PIV) experiments were carried out to get thermal flow field of a ACC under different conditions in low velocity wind tunnel,at the same time,the recirculation ratio at cooling tower was measured,so the relationship between flow field characteristics and recirculation ratio of cooling tower can be discussed. From the results we can see that the flow field configuration around cooling tower has great effects on average recirculation ratio under cooling tower. The eddy formed around cooling tower is a key reason that recirculation produces. The eddy intensity relates to velocity magnitude and direction angle,and the configuration of eddy lies on the geometry size of cooling tower. So changing the flow field configuration around cooling tower reasonably can decrease recirculation ratio under cooling tower,and heat dispel effect of ACC can also be improved.展开更多
Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this...Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this continuous changes in generation condition, the fault current level in network will be affected, this changes in fault current level will affect in the coordination between protection relays and to keep the coordination at right way, an adaptive protection system is required that can adaptive its setting according to generation changes, the fault current level in each case is evaluated using ETAP software, and the required relay setting in each case is also evaluated using Grey Wolf Optimizer (GWO) algorithm, and to select suitable setting which required in each condition, to select the active setting group of protection relay according to generation capacity, central protection unite can be used, and to improve protection stability and minimizing relays tripping time, a proposed method for selecting suitable backup relay is used, which leads to decrease relays tripping time and increase system stability, output settings for relays in all cases achieved our constrains.展开更多
In the past 30 years,signed directed graph(SDG) ,one of the qualitative simulation technologies,has been widely applied for chemical fault diagnosis.However,SDG based fault diagnosis,as any other qualitative method,ha...In the past 30 years,signed directed graph(SDG) ,one of the qualitative simulation technologies,has been widely applied for chemical fault diagnosis.However,SDG based fault diagnosis,as any other qualitative method,has poor diagnostic resolution.In this paper,a new method that combines SDG with qualitative trend analysis(QTA) is presented to improve the resolution.In the method,a bidirectional inference algorithm based on assumption and verification is used to find all the possible fault causes and their corresponding consistent paths in the SDG model.Then an improved QTA algorithm is used to extract and analyze the trends of nodes on the consis-tent paths found in the previous step.New consistency rules based on qualitative trends are used to find the real causes from the candidate causes.The resolution can be improved.This method combines the completeness feature of SDG with the good diagnostic resolution feature of QTA.The implementation of SDG-QTA based fault diagno-sis is done using the integrated SDG modeling,inference and post-processing software platform.Its application is illustrated on an atmospheric distillation tower unit of a simulation platform.The result shows its good applicability and efficiency.展开更多
BACKGROUND: Airway management in intensive care unit(ICU) patients is challenging. The aim of this study was to compare the rate of successful first-pass intubation in the ICU by using the direct laryngoscopy(DL) and ...BACKGROUND: Airway management in intensive care unit(ICU) patients is challenging. The aim of this study was to compare the rate of successful first-pass intubation in the ICU by using the direct laryngoscopy(DL) and that by using the video laryngoscopy(VL).METHODS: A randomized, non-blinded trial comparing first-pass success rate of intubation between VL and DL was performed. Patients were recruited in the period from August 2014 to August 2016. All physicians working at ICU received hands-on training in the use of the video and direct laryngoscope. The primary outcome measure was the first-pass intubation success. RESULTS: A total of 163 ICU patients underwent intubation during the study period(81 patients in VL group and 82 in DL group). The rate of successful first-pass intubation was not significantly different between the VL and the DL group(67.9% vs. 69.5%, P=0.824). Moreover, the overall intubation success and total number of attempts to achieve intubation success did not differ between the two groups. In patients with successful first-pass intubation, the median duration of the intubation procedure did not differ between the two groups. The Cormack-Lehane grades and the percentage of glottic opening score were similar, and no significant differences were found between the two groups. There were no statistical differences between the VL and the DL group in intubation complications(all P>0.05). CONCLUSION: Among ICU patients requiring intubation, there was no significant difference in the rate of successful first-pass intubation between VL and DL.展开更多
Patients with acute kidney injury(AKI) in the intensive care unit(ICU) are often suitable for palliative care due to the high symptom burden. The role of palliative medicine in this patient population is not well defi...Patients with acute kidney injury(AKI) in the intensive care unit(ICU) are often suitable for palliative care due to the high symptom burden. The role of palliative medicine in this patient population is not well defined and there is a lack of established guidelines to address this issue. Because of this,patients in the ICU with AKI deprived of the most comprehensive or appropriate care. The reasons for this are multifactorial including lack of palliative care training among nephrologists. However,palliative care in these patients can help alleviate symptoms,improve quality of life,and decrease suffering. Palliative care physicians can determine the appropriateness and model of palliative care. In addition to shared decision-making,advance directives should be established with patients early on,with specific instructions regarding dialysis,and those advance directives should be respected.展开更多
BACKGROUND The utility of hepatitis C virus(HCV)organs has increased after the Food and Drug Administration approval of direct acting anti-viral(DAA)medications for the HCV treatment.The efficacy of DAA in treating HC...BACKGROUND The utility of hepatitis C virus(HCV)organs has increased after the Food and Drug Administration approval of direct acting anti-viral(DAA)medications for the HCV treatment.The efficacy of DAA in treating HCV is nearly 100%.AIM To analyze the United Network for Organ Sharing(UNOS)database to compare the survival rates between the hepatitis C positive donors and negative recipients and hepatitis C negative donors and recipients.METHODS We analyzed the adult patients in UNOS database who underwent deceased donor liver transplant from January 2014 to December 2017.The primary endpoint was to compare the survival rates among the four groups with different hepatitis C donor and recipient status:(Group 1)Both donor and recipient negative for HCV(Group 2)Negative donor and positive recipient for HCV(Group 3)Positive donor and negative recipient for HCV(Group 4)Both positive donor and recipient for HCV.SAS 9.4 software was used for the data analysis.Kaplan Meier log rank test was used to analyze the estimated survival rates among the four groups.RESULTS A total of 24512 patients were included:Group 1:16436,Group 2:6174,Group 3:253 and Group 4:1649.The 1-year(Group 1:91.8%,Group 2:92.12%,Group 3:87%,Group 4:92.8%),2-year(Group 1:88.4%,Group 2:88.1%,Group 3:84.3%,Group 4:87.5%),3-year(Group 1:84.9%,Group 2:84.3%,Group 3:75.9%,Group 4:83.2%)survival rates showed no statistical significance among the four groups.Kaplan Meier log rank test did not show any statistical significance difference in the estimated survival rates between Group 3 vs all the other groups.CONCLUSION The survival rates in hepatitis C positive donors and negative recipients are similar as compared to both hepatitis C negative donors and recipients.This could be due to the use of DAA therapy with cure rates of nearly 100%.This study supports the use of hepatitis C positive organs in the selected group of recipients with and without HCV infection.Further long-term studies are needed to further validate these findings.展开更多
AIM: To assess the rate of infection, appropriateness of antimicrobial-therapy and mortality on intensive care unit(ICU). Special focus was drawn on patients with liver cirrhosis.METHODS: The study was approved by the...AIM: To assess the rate of infection, appropriateness of antimicrobial-therapy and mortality on intensive care unit(ICU). Special focus was drawn on patients with liver cirrhosis.METHODS: The study was approved by the local ethical committee. All patients admitted to the Internal Medicine-ICU between April 1, 2007 and December 31, 2009 were included. Data were extracted retrospectively from all patients using patient charts and electronic documentations on infection, microbiological laboratory reports, diagnosis and therapy. Due to the large hepatology department and liver transplantation center, special interest was on the subgroup of patients with liver cirrhosis. The primary statistical-endpoint was the evaluation of the influence of appropriate versusinappropriate antimicrobial-therapy on in-hospitalmortality.RESULTS: Charts of 1979 patients were available. The overall infection-rate was 53%. Multiresistantbacteria were present in 23% of patients with infection and were associated with increased mortality(p < 0.000001). patients with infection had significantly increased in-hospital-mortality(34% vs 17%, p < 0.000001). Only 9% of patients with infection received inappropriate initial antimicrobial-therapy, no influence on mortality was observed. Independent risk-factors for in-hospital-mortality were the presence of septicshock, prior chemotherapy for malignoma and infection with pseudomonas spp. Infection and mortality-rate among 175 patients with liver-cirrhosis was significantly higher than in patients without liver-cirrhosis. Infection increased mortality 2.24-fold in patients with cirrhosis. patients with liver cirrhosis were at an increased risk to receive inappropriate initial antimicrobial therapy.CONCLUSION: The results of the present study report the successful implementation of early-goal-directed therapy. Liver cirrhosis patients are at increased risk of infection, mortality and to receive inappropriate therapy. Increasing burden are multiresistant-bacteria.展开更多
Imaging department is an important department of a hospital contributing directly to patient care, providing diagnostic support to all specialties which cannot practice efficiently without their support. Hospital admi...Imaging department is an important department of a hospital contributing directly to patient care, providing diagnostic support to all specialties which cannot practice efficiently without their support. Hospital administrators are looking for newer tools to control costs without affecting the quality of patient care. It is well known that the escalation of costs for advanced technology has been dramatic and it has been labeled as one of the culprits for great increase in healthcare costs. A prospective study for a period of six months was carried out for calculation of unit cost of radiological investigations CT head, CT chest, CT abdomen and MRI. Unit costs were computed under direct and indirect costs. The actual cost incurred by the hospital on CT head was Rupees 581.40 (US $10.89), CT abdomen Rupees 2339.20 (US $43.83), CT chest Rupees 2339.20 (US $43.83), and MRI Rupees 4497.50 (US $84.28). However, in the hospital patients are charged Rupees 900 (US $16.86) for CT head, Rupees 1200 (US $22.48) for CT abdomen, Rupees 1200 (US $22.48) for CT chest and Rupees 2500 (US $46.85) for MRI. There is a substantial loss of revenue because of subsidies provided to patients in a tertiary care teaching hospital which needs revision of charges.展开更多
The paper introduces thermal buoyancy effects to experimental investigation of wind tunnel simulation on direct air-cooled condenser for a large power plant. In order to get thermal flow field of air-cooled tower, PIV...The paper introduces thermal buoyancy effects to experimental investigation of wind tunnel simulation on direct air-cooled condenser for a large power plant. In order to get thermal flow field of air-cooled tower, PIV experiments are carried out and recirculation ratio of each condition is calculated. Results show that the thermal flow field of the cooling tower has great influence on the recirculation under the cooling tower. Ameliorating the thermal flow field of the cooling tower can reduce the recirculation under the cooling tower and improve the efficiency of air-cooled condenser also.展开更多
A model to derive direct runoff hydrograph for an ungauged basin using the physical properties of the basin is presented. The basin is divided into grid cells and canal elements. Overland flow is generated from each g...A model to derive direct runoff hydrograph for an ungauged basin using the physical properties of the basin is presented. The basin is divided into grid cells and canal elements. Overland flow is generated from each grid cell of the basin by application of continuous effective rainfall of I mm/hr to the basin, The flow generated is routed through downstream grid cells and the canal elements using the kinematic wave approach. The travel time for direct runoff from each grid cell to the basin outlet is calculated and the S-curve is derived for the basin. The S-curve is used to derive the unit hydrograph of a given duration for the basin. The model, referred as Cell-basin model was applied to the Upper Kotmale Basin in Sri Lanka and the model predictions of direct runoff hydrographs for rainfall events agreed with the observations to a reasonable accuracy. Comparison of the unit hydrographs obtained from the model and from the conventional Snyder's synthetic unit hydrograph using regionalized parameters assuming the basin as an ungauged basin, with the unit hydrograph derived from the observations showed that the model predicted unit hydrograph was more suitable than that obtained by Snyder's method for Sri Lankan up country basins. Thus, the present model is a useful tool to obtain direct runoff hydrograph for ungauged basins.展开更多
针对高压直流(high voltage direct current,HVDC)输电线路故障暂态行波具有时序性和强非线性的特点,导致高过渡电阻情况下故障识别率低的问题,提出基于卷积神经网络(convolutional neural networks,CNN)和双向循环门单元(bidirectional...针对高压直流(high voltage direct current,HVDC)输电线路故障暂态行波具有时序性和强非线性的特点,导致高过渡电阻情况下故障识别率低的问题,提出基于卷积神经网络(convolutional neural networks,CNN)和双向循环门单元(bidirectional gate recurrent unit,BiGRU)的HVDC输电线路故障识别方法。首先,采用故障后整流侧的双极暂态电流行波作为特征向量,利用CNN提取全局特征,并从中剔除噪声和不稳定成分,完成对数据的降维处理。然后,采用BiGRU来捕获CNN提取到特征的前后时间信息,进一步提取数据中的时序特征,以实现HVDC输电线路故障识别。仿真结果表明:该方法可在不同故障地点以及不同过渡电阻下对单极接地、双极短路、雷击故障、雷击干扰共四种故障实现准确识别,可靠性高,具有较强的耐受过渡电阻能力,同时具备一定的抗噪性能。展开更多
文摘Given the distribution feature of resources such as coal and water, the requirements for the development of Chinese power industry, and the fact of monopoly by foreign companies, it is very necessary and significant to independently research and develop air-cooling technologies. Through experimental research, simulative calculation, process and equipment development, field tests and a demonstration project, the design and operation technologies for air-cooling system are grasped and relevant key equipment is developed. The results of the demonstration project show that the technical indicators for the air-cooling system have met or exceeded the design requirements. Part of the research results have been incorporated into the relevant national design standards. The technologies developed have been applied to more than 23 sets of thermal power units of or above 600 MW in China.
文摘The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2.
文摘In order to get thermal flow field of direct air-cooled system,the hot water was supplied to the model of direct air-cooled condenser(ACC). The particle image velocimetery (PIV) experiments were carried out to get thermal flow field of a ACC under different conditions in low velocity wind tunnel,at the same time,the recirculation ratio at cooling tower was measured,so the relationship between flow field characteristics and recirculation ratio of cooling tower can be discussed. From the results we can see that the flow field configuration around cooling tower has great effects on average recirculation ratio under cooling tower. The eddy formed around cooling tower is a key reason that recirculation produces. The eddy intensity relates to velocity magnitude and direction angle,and the configuration of eddy lies on the geometry size of cooling tower. So changing the flow field configuration around cooling tower reasonably can decrease recirculation ratio under cooling tower,and heat dispel effect of ACC can also be improved.
文摘Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this continuous changes in generation condition, the fault current level in network will be affected, this changes in fault current level will affect in the coordination between protection relays and to keep the coordination at right way, an adaptive protection system is required that can adaptive its setting according to generation changes, the fault current level in each case is evaluated using ETAP software, and the required relay setting in each case is also evaluated using Grey Wolf Optimizer (GWO) algorithm, and to select suitable setting which required in each condition, to select the active setting group of protection relay according to generation capacity, central protection unite can be used, and to improve protection stability and minimizing relays tripping time, a proposed method for selecting suitable backup relay is used, which leads to decrease relays tripping time and increase system stability, output settings for relays in all cases achieved our constrains.
基金Supported by the Science and Technological Tackling Project of Heilongjiang Province(GB06A106)
文摘In the past 30 years,signed directed graph(SDG) ,one of the qualitative simulation technologies,has been widely applied for chemical fault diagnosis.However,SDG based fault diagnosis,as any other qualitative method,has poor diagnostic resolution.In this paper,a new method that combines SDG with qualitative trend analysis(QTA) is presented to improve the resolution.In the method,a bidirectional inference algorithm based on assumption and verification is used to find all the possible fault causes and their corresponding consistent paths in the SDG model.Then an improved QTA algorithm is used to extract and analyze the trends of nodes on the consis-tent paths found in the previous step.New consistency rules based on qualitative trends are used to find the real causes from the candidate causes.The resolution can be improved.This method combines the completeness feature of SDG with the good diagnostic resolution feature of QTA.The implementation of SDG-QTA based fault diagno-sis is done using the integrated SDG modeling,inference and post-processing software platform.Its application is illustrated on an atmospheric distillation tower unit of a simulation platform.The result shows its good applicability and efficiency.
文摘BACKGROUND: Airway management in intensive care unit(ICU) patients is challenging. The aim of this study was to compare the rate of successful first-pass intubation in the ICU by using the direct laryngoscopy(DL) and that by using the video laryngoscopy(VL).METHODS: A randomized, non-blinded trial comparing first-pass success rate of intubation between VL and DL was performed. Patients were recruited in the period from August 2014 to August 2016. All physicians working at ICU received hands-on training in the use of the video and direct laryngoscope. The primary outcome measure was the first-pass intubation success. RESULTS: A total of 163 ICU patients underwent intubation during the study period(81 patients in VL group and 82 in DL group). The rate of successful first-pass intubation was not significantly different between the VL and the DL group(67.9% vs. 69.5%, P=0.824). Moreover, the overall intubation success and total number of attempts to achieve intubation success did not differ between the two groups. In patients with successful first-pass intubation, the median duration of the intubation procedure did not differ between the two groups. The Cormack-Lehane grades and the percentage of glottic opening score were similar, and no significant differences were found between the two groups. There were no statistical differences between the VL and the DL group in intubation complications(all P>0.05). CONCLUSION: Among ICU patients requiring intubation, there was no significant difference in the rate of successful first-pass intubation between VL and DL.
文摘Patients with acute kidney injury(AKI) in the intensive care unit(ICU) are often suitable for palliative care due to the high symptom burden. The role of palliative medicine in this patient population is not well defined and there is a lack of established guidelines to address this issue. Because of this,patients in the ICU with AKI deprived of the most comprehensive or appropriate care. The reasons for this are multifactorial including lack of palliative care training among nephrologists. However,palliative care in these patients can help alleviate symptoms,improve quality of life,and decrease suffering. Palliative care physicians can determine the appropriateness and model of palliative care. In addition to shared decision-making,advance directives should be established with patients early on,with specific instructions regarding dialysis,and those advance directives should be respected.
文摘BACKGROUND The utility of hepatitis C virus(HCV)organs has increased after the Food and Drug Administration approval of direct acting anti-viral(DAA)medications for the HCV treatment.The efficacy of DAA in treating HCV is nearly 100%.AIM To analyze the United Network for Organ Sharing(UNOS)database to compare the survival rates between the hepatitis C positive donors and negative recipients and hepatitis C negative donors and recipients.METHODS We analyzed the adult patients in UNOS database who underwent deceased donor liver transplant from January 2014 to December 2017.The primary endpoint was to compare the survival rates among the four groups with different hepatitis C donor and recipient status:(Group 1)Both donor and recipient negative for HCV(Group 2)Negative donor and positive recipient for HCV(Group 3)Positive donor and negative recipient for HCV(Group 4)Both positive donor and recipient for HCV.SAS 9.4 software was used for the data analysis.Kaplan Meier log rank test was used to analyze the estimated survival rates among the four groups.RESULTS A total of 24512 patients were included:Group 1:16436,Group 2:6174,Group 3:253 and Group 4:1649.The 1-year(Group 1:91.8%,Group 2:92.12%,Group 3:87%,Group 4:92.8%),2-year(Group 1:88.4%,Group 2:88.1%,Group 3:84.3%,Group 4:87.5%),3-year(Group 1:84.9%,Group 2:84.3%,Group 3:75.9%,Group 4:83.2%)survival rates showed no statistical significance among the four groups.Kaplan Meier log rank test did not show any statistical significance difference in the estimated survival rates between Group 3 vs all the other groups.CONCLUSION The survival rates in hepatitis C positive donors and negative recipients are similar as compared to both hepatitis C negative donors and recipients.This could be due to the use of DAA therapy with cure rates of nearly 100%.This study supports the use of hepatitis C positive organs in the selected group of recipients with and without HCV infection.Further long-term studies are needed to further validate these findings.
文摘AIM: To assess the rate of infection, appropriateness of antimicrobial-therapy and mortality on intensive care unit(ICU). Special focus was drawn on patients with liver cirrhosis.METHODS: The study was approved by the local ethical committee. All patients admitted to the Internal Medicine-ICU between April 1, 2007 and December 31, 2009 were included. Data were extracted retrospectively from all patients using patient charts and electronic documentations on infection, microbiological laboratory reports, diagnosis and therapy. Due to the large hepatology department and liver transplantation center, special interest was on the subgroup of patients with liver cirrhosis. The primary statistical-endpoint was the evaluation of the influence of appropriate versusinappropriate antimicrobial-therapy on in-hospitalmortality.RESULTS: Charts of 1979 patients were available. The overall infection-rate was 53%. Multiresistantbacteria were present in 23% of patients with infection and were associated with increased mortality(p < 0.000001). patients with infection had significantly increased in-hospital-mortality(34% vs 17%, p < 0.000001). Only 9% of patients with infection received inappropriate initial antimicrobial-therapy, no influence on mortality was observed. Independent risk-factors for in-hospital-mortality were the presence of septicshock, prior chemotherapy for malignoma and infection with pseudomonas spp. Infection and mortality-rate among 175 patients with liver-cirrhosis was significantly higher than in patients without liver-cirrhosis. Infection increased mortality 2.24-fold in patients with cirrhosis. patients with liver cirrhosis were at an increased risk to receive inappropriate initial antimicrobial therapy.CONCLUSION: The results of the present study report the successful implementation of early-goal-directed therapy. Liver cirrhosis patients are at increased risk of infection, mortality and to receive inappropriate therapy. Increasing burden are multiresistant-bacteria.
文摘Imaging department is an important department of a hospital contributing directly to patient care, providing diagnostic support to all specialties which cannot practice efficiently without their support. Hospital administrators are looking for newer tools to control costs without affecting the quality of patient care. It is well known that the escalation of costs for advanced technology has been dramatic and it has been labeled as one of the culprits for great increase in healthcare costs. A prospective study for a period of six months was carried out for calculation of unit cost of radiological investigations CT head, CT chest, CT abdomen and MRI. Unit costs were computed under direct and indirect costs. The actual cost incurred by the hospital on CT head was Rupees 581.40 (US $10.89), CT abdomen Rupees 2339.20 (US $43.83), CT chest Rupees 2339.20 (US $43.83), and MRI Rupees 4497.50 (US $84.28). However, in the hospital patients are charged Rupees 900 (US $16.86) for CT head, Rupees 1200 (US $22.48) for CT abdomen, Rupees 1200 (US $22.48) for CT chest and Rupees 2500 (US $46.85) for MRI. There is a substantial loss of revenue because of subsidies provided to patients in a tertiary care teaching hospital which needs revision of charges.
文摘The paper introduces thermal buoyancy effects to experimental investigation of wind tunnel simulation on direct air-cooled condenser for a large power plant. In order to get thermal flow field of air-cooled tower, PIV experiments are carried out and recirculation ratio of each condition is calculated. Results show that the thermal flow field of the cooling tower has great influence on the recirculation under the cooling tower. Ameliorating the thermal flow field of the cooling tower can reduce the recirculation under the cooling tower and improve the efficiency of air-cooled condenser also.
文摘A model to derive direct runoff hydrograph for an ungauged basin using the physical properties of the basin is presented. The basin is divided into grid cells and canal elements. Overland flow is generated from each grid cell of the basin by application of continuous effective rainfall of I mm/hr to the basin, The flow generated is routed through downstream grid cells and the canal elements using the kinematic wave approach. The travel time for direct runoff from each grid cell to the basin outlet is calculated and the S-curve is derived for the basin. The S-curve is used to derive the unit hydrograph of a given duration for the basin. The model, referred as Cell-basin model was applied to the Upper Kotmale Basin in Sri Lanka and the model predictions of direct runoff hydrographs for rainfall events agreed with the observations to a reasonable accuracy. Comparison of the unit hydrographs obtained from the model and from the conventional Snyder's synthetic unit hydrograph using regionalized parameters assuming the basin as an ungauged basin, with the unit hydrograph derived from the observations showed that the model predicted unit hydrograph was more suitable than that obtained by Snyder's method for Sri Lankan up country basins. Thus, the present model is a useful tool to obtain direct runoff hydrograph for ungauged basins.
文摘针对高压直流(high voltage direct current,HVDC)输电线路故障暂态行波具有时序性和强非线性的特点,导致高过渡电阻情况下故障识别率低的问题,提出基于卷积神经网络(convolutional neural networks,CNN)和双向循环门单元(bidirectional gate recurrent unit,BiGRU)的HVDC输电线路故障识别方法。首先,采用故障后整流侧的双极暂态电流行波作为特征向量,利用CNN提取全局特征,并从中剔除噪声和不稳定成分,完成对数据的降维处理。然后,采用BiGRU来捕获CNN提取到特征的前后时间信息,进一步提取数据中的时序特征,以实现HVDC输电线路故障识别。仿真结果表明:该方法可在不同故障地点以及不同过渡电阻下对单极接地、双极短路、雷击故障、雷击干扰共四种故障实现准确识别,可靠性高,具有较强的耐受过渡电阻能力,同时具备一定的抗噪性能。