In this paper, a carbon dioxide trans-critical refrigerating system which is different from a conventional subcritical refrigerating cycle was studied. The trans-critical carbon dioxide refrigerating systems are based...In this paper, a carbon dioxide trans-critical refrigerating system which is different from a conventional subcritical refrigerating cycle was studied. The trans-critical carbon dioxide refrigerating systems are based on the Gustav Lorntzen cycle. Emphasis was focused on how to determine the optimal discharge pressure of compressor in CO2 trans-critical cycle. The factors related with the optimal discharge pressure were analyzed. A formula was developed based on cycle simulation, which could be used to predict the optimal discharge pressure of a basic CO2 trans-critical cycle. After further studies on CO2 trans-critical cycles with a regenerator or expander, two more formulas were also developed. These formulas could provide an access to improve the COP of CO2 trans-critical cycle.展开更多
Battery energy storage systems(BESSs)can provide instantaneous support for frequency regulation(FR)because of their fast response characteristics.However,purely pursuing a better FR effect calls for continually rapid ...Battery energy storage systems(BESSs)can provide instantaneous support for frequency regulation(FR)because of their fast response characteristics.However,purely pursuing a better FR effect calls for continually rapid cycles of BESSs,which shortens their lifetime and deteriorates the operational economy.To coordinate the lifespan savings and the FR effect,this paper presents a control strategy for the FR of BESSs based on fuzzy logic and hierarchical controllers.The fuzzy logic controller improves the effect of FR by adjusting the charging/discharging power of the BESS with a higher response speed and precision based on the area control error(ACE)signal and the change rate of ACE in a non-linear way.Hierarchical controllers effectively reduce the life loss by optimizing the depth of discharge,which ensures that the state of charge(SOC)of BESS is always in the optimal operating range,and the total FR cost is the lowest at this time.The proposed method can achieve the optimal balance between ACE reduction and operational economy of BESS.The effectiveness of the proposed strategy is verified in a two-area power system.展开更多
基金This work was supported by Beijing Foundation for Academic Human Resources Development in Institution and the Beijing Foundation for Natural Science
文摘In this paper, a carbon dioxide trans-critical refrigerating system which is different from a conventional subcritical refrigerating cycle was studied. The trans-critical carbon dioxide refrigerating systems are based on the Gustav Lorntzen cycle. Emphasis was focused on how to determine the optimal discharge pressure of compressor in CO2 trans-critical cycle. The factors related with the optimal discharge pressure were analyzed. A formula was developed based on cycle simulation, which could be used to predict the optimal discharge pressure of a basic CO2 trans-critical cycle. After further studies on CO2 trans-critical cycles with a regenerator or expander, two more formulas were also developed. These formulas could provide an access to improve the COP of CO2 trans-critical cycle.
基金This work was supported by Open Research Project of State Key Laboratory of Control and Simulation of Power Systems and Generation Equipments,Tsinghua University(No.SKLD20M20)Xinjiang Uygur Autonomous Region Natural Science Key Project of University Research Program(No.XJEDU2020I004).
文摘Battery energy storage systems(BESSs)can provide instantaneous support for frequency regulation(FR)because of their fast response characteristics.However,purely pursuing a better FR effect calls for continually rapid cycles of BESSs,which shortens their lifetime and deteriorates the operational economy.To coordinate the lifespan savings and the FR effect,this paper presents a control strategy for the FR of BESSs based on fuzzy logic and hierarchical controllers.The fuzzy logic controller improves the effect of FR by adjusting the charging/discharging power of the BESS with a higher response speed and precision based on the area control error(ACE)signal and the change rate of ACE in a non-linear way.Hierarchical controllers effectively reduce the life loss by optimizing the depth of discharge,which ensures that the state of charge(SOC)of BESS is always in the optimal operating range,and the total FR cost is the lowest at this time.The proposed method can achieve the optimal balance between ACE reduction and operational economy of BESS.The effectiveness of the proposed strategy is verified in a two-area power system.