The article presents an experimental and numerical study on thermal performance enhancement in a constant heatfluxed square-duct inserted diagonally with 45° discrete V-finned tapes(DFT).The experiments were carr...The article presents an experimental and numerical study on thermal performance enhancement in a constant heatfluxed square-duct inserted diagonally with 45° discrete V-finned tapes(DFT).The experiments were carried out by varying the airflow rate through the tested square duct with DFT inserts for Reynolds number from 4000 to 25000.The effect of the DFT with V-tip pointing upstream at various relative fin heights and pitches on heat transfer and pressure drop characteristics was experimentally investigated.Both the heat transfer and pressure drop were presented in terms of Nusselt number and friction factor respectively.Several V-finned tape characteristics were introduced such as fin- to duct-height ratio or blockage ratio(R_B=e/H = 0.075,0.1,0.15 and 0.2),fin pitch to duct height ratio(R_P= P/H=0.5,1.0,1.5 and 2.0) and fin attack angle,α = 45°.The experimental results reveal that the heat transfer and friction factor values with DFT inserts increase with the increment of R_B but the decrease of R_P.The inserted square-duct at R_B = 0.2 and R_P = 0.5 provides the highest heat transfer and friction factor while the one with R_B= 0.1 and R_P= 1.5 yields the highest thermal performance.Also,a numerical simulation was conducted to investigate the flow structure and heat transfer mechanism inside the tested duct with DFT inserts.展开更多
Discrete H ∞ control theory were obtained by conjugation,chain scattering representation and (J,J′) lossless factorization.The existence of the solution is equivalent to the existence of two positive s...Discrete H ∞ control theory were obtained by conjugation,chain scattering representation and (J,J′) lossless factorization.The existence of the solution is equivalent to the existence of two positive solutions of two Riccati equations.展开更多
Consider an observed binary regressor D and an unobserved binary vari- able D*, both of which affect some other variable Y. This paper considers nonpara- metric identification and estimation of the effect of D on Y, ...Consider an observed binary regressor D and an unobserved binary vari- able D*, both of which affect some other variable Y. This paper considers nonpara- metric identification and estimation of the effect of D on Y, conditioning on D* = 0. For example, suppose Y is a person's wage, the unobserved D* indicates if the person has been to college, and the observed D indicates whether the individual claims to have been to college. This paper then identifies and estimates the difference in av- erage wages between those who falsely claim college experience versus those who tell the truth about not having college. We estimate this average effect of lying to be about 6% to 20%. Nonparametric identification without observing D* is obtained ei- ther by observing a variable V that is roughly analogous to an instrument for ordinary measurement error, or by imposing restrictions on model error moments.展开更多
基金Supported by the Energy Policy and Planning Office,Ministry of Energy,Thailand
文摘The article presents an experimental and numerical study on thermal performance enhancement in a constant heatfluxed square-duct inserted diagonally with 45° discrete V-finned tapes(DFT).The experiments were carried out by varying the airflow rate through the tested square duct with DFT inserts for Reynolds number from 4000 to 25000.The effect of the DFT with V-tip pointing upstream at various relative fin heights and pitches on heat transfer and pressure drop characteristics was experimentally investigated.Both the heat transfer and pressure drop were presented in terms of Nusselt number and friction factor respectively.Several V-finned tape characteristics were introduced such as fin- to duct-height ratio or blockage ratio(R_B=e/H = 0.075,0.1,0.15 and 0.2),fin pitch to duct height ratio(R_P= P/H=0.5,1.0,1.5 and 2.0) and fin attack angle,α = 45°.The experimental results reveal that the heat transfer and friction factor values with DFT inserts increase with the increment of R_B but the decrease of R_P.The inserted square-duct at R_B = 0.2 and R_P = 0.5 provides the highest heat transfer and friction factor while the one with R_B= 0.1 and R_P= 1.5 yields the highest thermal performance.Also,a numerical simulation was conducted to investigate the flow structure and heat transfer mechanism inside the tested duct with DFT inserts.
文摘Discrete H ∞ control theory were obtained by conjugation,chain scattering representation and (J,J′) lossless factorization.The existence of the solution is equivalent to the existence of two positive solutions of two Riccati equations.
文摘Consider an observed binary regressor D and an unobserved binary vari- able D*, both of which affect some other variable Y. This paper considers nonpara- metric identification and estimation of the effect of D on Y, conditioning on D* = 0. For example, suppose Y is a person's wage, the unobserved D* indicates if the person has been to college, and the observed D indicates whether the individual claims to have been to college. This paper then identifies and estimates the difference in av- erage wages between those who falsely claim college experience versus those who tell the truth about not having college. We estimate this average effect of lying to be about 6% to 20%. Nonparametric identification without observing D* is obtained ei- ther by observing a variable V that is roughly analogous to an instrument for ordinary measurement error, or by imposing restrictions on model error moments.