期刊文献+
共找到334篇文章
< 1 2 17 >
每页显示 20 50 100
Double enzyme mimetic activities of multifunctional Ag nanoparticle-decorated Co_(3)V_(2)O_(8)hollow hexagonal prismatic pencils for application in colorimetric sensors and disinfection
1
作者 Ying Gao Peng Ju +4 位作者 Yu Zhang Yuxin Zhang Xiaofan Zhai Jizhou Duan Baorong Hou 《Nano Materials Science》 EI CAS CSCD 2024年第2期244-255,共12页
Since the catalytic activity of most nanozymes is still far lower than the corresponding natural enzymes,there is urgent need to discover novel highly efficient enzyme-like materials.In this work,Co_(3)V_(2)O_(8)with ... Since the catalytic activity of most nanozymes is still far lower than the corresponding natural enzymes,there is urgent need to discover novel highly efficient enzyme-like materials.In this work,Co_(3)V_(2)O_(8)with hollow hexagonal prismatic pencil structures were prepared as novel artificial enzyme mimics.They were then decorated by photo-depositing Ag nanoparticles(Ag NPs)on the surface to further improve its catalytic activities.The Ag NPs decorated Co_(3)V_(2)O_(8)(ACVPs)showed both excellent oxidase-and peroxidase-like catalytic activities.They can oxidize the colorless 3,3’,5,5’-tetramethylbenzidine rapidly to induce a blue change.The enhanced enzyme mimetic activities can be attributed to the surface plasma resonance(SPR)effect of Ag NPs as well as the synergistic catalytic effect between Ag NPs and Co_(3)V_(2)O_(8),accelerating electron transfer and promoting the catalytic process.ACVPs were applied in constructing a colorimetric sensor,validating the occurrence of the Fenton reaction,and disinfection,presenting favorable catalytic performance.The enzyme-like catalytic mechanism was studied,indicating the chief role of⋅O_(2)-radicals in the catalytic process.This work not only discovers a novel functional material with double enzyme mimetic activity but also provides a new insight into exploiting artificial enzyme mimics with highly efficient catalytic ability. 展开更多
关键词 Co_(3)V_(2)O_(8) Ag NPs Enzyme mimetic Colorimetric sensor disinfection
下载PDF
Performance Parameters:Demobilization Antibiotic Resistant Bacteria(ARB)and Carrying Genes(ARG)in Wastewater Disinfection
2
作者 Solange Kazue Utimura Denise Crocce Romano Espinosa +2 位作者 Marcio Luís Busi da Silva Elisabete de Santis Braga Pedro Jose Alvarez 《Journal of Environmental Science and Engineering(B)》 2024年第1期1-8,共8页
The UV irradiation is used for removing Antibiotic Resistant Bacteria(ARB)and Antibiotic Resistance Genes(ARG)from wastewater treatment.Bacteriophages are viruses that infect within bacteria,are recognized for bacteri... The UV irradiation is used for removing Antibiotic Resistant Bacteria(ARB)and Antibiotic Resistance Genes(ARG)from wastewater treatment.Bacteriophages are viruses that infect within bacteria,are recognized for bacterial control.The influence of some parameters in quantification and performance influencing of pathogen demobilization could be considered in disinfection of wastewater.The comparison of Polyvalent phage(NE1)versus Coliphage(NE4)in suppressing a bacterium Escherichia coli(NDM-1:b-lactam-resistant)with UV irradiation was observed the efficacy in reduction of cells in the disinfection and parameter process.The results with the effect of UV-C irradiation on NDM-1 infected with 1%of NE4 showed a decrease of cells from 8×10^(6)to 2×10^(5)in 60 min with UV-C dose.The NDM1(E.coli)was infected with 1%of NE4(Polyvalent Phage)under magnetic stirring for 1 h,the cells count was 8×10^(6).After 1 h in UV-C e×posure,the cells number reached 3×10^(5).The NDM1 that was e×posed in 1 h of UV-C irradiation and then was infected with 1%of NE4.Cells counting were done 24 h after this procedure.These cells were e×posed in UV-C and showed a reduction in the number of cells from 1×10^(8)to 4×10^(5)after 60 min.The results indicate that bacteriophages can mitigate bacteria species,and combined the conventional water disinfection technologies that can support the microbial safety control strategies. 展开更多
关键词 Antibiotic Resistant Bacteria(ARB) Antibiotic Resistance Genes(ARG) wastewater treatment disinfection Escherichia coli(E.coli).
下载PDF
Progress in Analytical Methods of Halogenated Disinfection By-Products
3
作者 Jing Wu 《Proceedings of Business and Economic Studies》 2024年第2期95-99,共5页
Ensuring the health and safety of drinking water is crucial for both nations and their citizens.Since the 20th century,the disinfection of drinking water,effectively controlling pathogens in water sources,has become o... Ensuring the health and safety of drinking water is crucial for both nations and their citizens.Since the 20th century,the disinfection of drinking water,effectively controlling pathogens in water sources,has become one of the significant advances in public health.However,the disinfectants used in the process,such as chlorine and chlorine dioxide,react with natural organic matter in the water to produce disinfection by-products(DBPs).Most of these DBPs contain chlorine,and if the source water contains bromine or iodine,brominated or iodinated DBPs,collectively referred to as Halogenated disinfection byproducts(X-DBPs),are formed.Numerous studies have found that X-DBPs pose potential risks to human health and the environment,leading to widespread concern.Mass spectrometry has become an important means of discovering new types of X-DBPs.This paper focuses on the study of methods for analyzing X-DBPs in drinking water using mass spectrometry. 展开更多
关键词 Halogenated disinfection by-products Drinking water High-resolution mass spectrometry
下载PDF
Evaluation of the Impact of Refined Quality Control Management Model on the Qualified Rate of Disinfection and Sterilization of Surgical Instruments in the Sterilization Supply Center
4
作者 Qin Liu 《Journal of Clinical and Nursing Research》 2024年第1期168-173,共6页
Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization sup... Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization supply center from January 2021 to January 2023.The work situation before January 31,2022,was classified as the control group;a routine quality control management model was implemented,and the work situation after January 31,2022,was classified as the observation group.The quality of medical device management and department satisfaction between the two groups were compared.Results:The timely recovery and supply rate,classification and cleaning pass rate,disinfection pass rate,packaging pass rate,sterilization pass rate,and department satisfaction score in the observation group were all higher than those of the control group(P<0.05).Conclusion:Implementing a refined quality control management model in the sterilization supply center can improve the quality management level of medical devices and department satisfaction and is worthy of promotion. 展开更多
关键词 Refined quality control management model Sterilization supply center disinfection and sterilization pass rate
下载PDF
Electrochemical disinfection using the gas diffusion electrode system 被引量:1
5
作者 Wenying Xu Ping Li Bin Dong 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2010年第2期204-210,共7页
A study on the electrochemical disinfection with H202 generated at the gas diffusion electrode (GDE) from active carbon/poly- tetrafluoroethylene was performed in a non-membrane cell. The effects of Pt load and the ... A study on the electrochemical disinfection with H202 generated at the gas diffusion electrode (GDE) from active carbon/poly- tetrafluoroethylene was performed in a non-membrane cell. The effects of Pt load and the pore-forming agent content in GDE, and operating conditions were investigated. The experimental results showed that nearly all bacterial cultures inoculated in the secondary effluent from wastewater treatment plant could be inactivated within 30 min at a current density of 10 mA/cm^2. The disinfection improved with increasing Pt load. Addition of the pore-forming agent NH4HCO3 improved the disinfection, while a drop in the pH value resulted in a rapid rise of germicidal efficacy and the disinfection time was shortened with increasing oxygen flow rate. Adsorption was proved to be ineffective in destroying bacteria, while germicidal efficacy increased with current density. The acceleration rate was different, it initially increased with current density. Then decreased, and finally reached a maximum at a current density of 6.7 mA/cm^2. The disinfection also improved with decreasing total bacterial count. The germicidal efficacy in the cathode compartment was approximately the same as in the anode compartment, indicating that the contribution of direct oxidation and the indirect treatment of bacterial cultures by hydroxyl radical was similar to the oxidative indirect effect of the generated H2O2. 展开更多
关键词 gas diffusion electrode CATHODE oxygen reduction electrochemical disinfection mechanism analysis
下载PDF
Improve the Center Supply Room to Ensure the Quality System for Disinfection and Sterilization 被引量:3
6
作者 Zhe Wang 《Journal of Advances in Medicine Science》 2020年第1期53-56,共4页
The disinfection supply room is a very important department of the hospital.Its main job is to provide sterile equipment and dressings for various activities in the hospital.It is an important department in the hospit... The disinfection supply room is a very important department of the hospital.Its main job is to provide sterile equipment and dressings for various activities in the hospital.It is an important department in the hospital infection management process.Doing a good job in the control and management of the disinfection supply room is the main link to ensure the prevention and control of hospital infections.The quality of management directly affects modern clinical medical work.Therefore,the hospital supply room should be strengthened and improved to ensure that all items can be safely used in the work process,which can effectively avoid the occurrence of cross-infection incidents in the hospital. 展开更多
关键词 CENTRAL supply ROOM disinfection and STERILIZATION Quality MANAGEMENT system MANAGEMENT
下载PDF
Microwave Disinfection in a Ventilation and Air-Conditioning System
7
作者 LU Zhen1,2,ZHANG Ji-li1,MA Liang-dong1,HE Juan3(1.School of Civil & Hydraulic Engineering,Dalian University of Technology,Dalian,Liaoning 116023,China 2.Municipal and Environmental Engineering Research Center,Shenyang Jianzhu University,Shenyang,Liaoning 110168,China 3.School of Municipal & Environmental Engineering,Harbin Institute of Technology,Harbin,Heilongjiang 150090,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期55-59,共5页
Because of its broad spectrum and high efficiency,the microwave disinfection was used to control the airborne microbial contaminates in VAC system.Some microwave disinfection devices were developed combined with air f... Because of its broad spectrum and high efficiency,the microwave disinfection was used to control the airborne microbial contaminates in VAC system.Some microwave disinfection devices were developed combined with air filter,the design and calculation method was presented,and the disinfection effects on White staphylococcus,Staphylococcus aureus,Bacillus Subtilis,Escherichi coli were measured.The results show that the major influence factors on disinfection effect are microwave power,water-content of filter material,disinfecting duration.After 15 min,the kill ratio is >90%,and the log value is >1.The microwave field is uniform and the kill effect of bacteria on each surface of filter is the same,without statistically significant difference. 展开更多
关键词 VAC system MICROWAVE disinfection AIRBORNE MICROBE MICROWAVE power KILL ratio
下载PDF
Which treatment protocol, among classical methods and/or various laser applications is the most effective in root canal disinfection, <i>in vitro</i>? A systematic review
8
作者 Joanna Theodosopoulou Konstantinos Chochlidakis Alexandra Tsigarida 《Open Journal of Stomatology》 2011年第4期126-139,共14页
Purpose: The aim of this systematic review was to answer the question “Which treatment protocol, am- ong classical methods and/or various laser applica- tions is the most effective in root canal disinfection, in vitr... Purpose: The aim of this systematic review was to answer the question “Which treatment protocol, am- ong classical methods and/or various laser applica- tions is the most effective in root canal disinfection, in vitro”. Materials and Methods: A MEDLINE, a Co- chrane and an Embase search (three specified search- es) were conducted to identify randomized controlled trials (RCT) until June 2010, conducted on human teeth and published in English, German or French language, examining the root canal disinfection after the use of lasers with or without mechanical instru-mentation. Additionally, hand search was conducted and contact with authors, when needed. Results: The MEDLINE, the Cochrane and the EMBASE search identified 240, 28, and 35 published articles, respec-tively. Ten articles from the MEDLINE and 5 articles from the Cochrane search (that were also identified in the MEDLINE search) met the inclusion and va-lidity assessment criteria. In E. faecalis elimination, instrumentation of the root canal and diode laser/665 nanometer/1 Watt (diode laser/665 nm/1 W) irradia-tion with the combined effect of Methylene Blue (MB) as photosensitizing agent (logCFU/ml = 1636) seemed to be the best method. In P. aeruginosa and in A.naeslundii elimination, instrumentation of the root canal followed by irrigation with 5, 25% NaOCl (log-CFU/ml = 0) seemed to be the best method. In gen-eral, instrumentation of the root canal followed by irrigation with 5, 25% NaOCl (logCFU/ml = 0) and instrumentation of the root canal and Er: YAG laser/ 2940 nm/0.8 W irradiation (logCFU/ml = 1924) seemed to be the best (polymicrobial studies). Conclusions: There are treatment protocols with the assistance or not of laser irradiation that can eliminate E. faecalis, E. coli and S. aureus inside the root canal. However, there is a serious number of S. anginosus, F. nuclea-tum, A. naeslundii and P. aeruginosa that remain in-side the root canal even after laser irradiation. New research is needed in order to set a treatment proto-col effective in the root canal disinfection from all bac-teria that are related to endodontic origin pathology. 展开更多
关键词 Lasers CLASSICAL METHODS ENDODONTIC Root Canal Therapy DENTIN Bacteria disinfection
下载PDF
Solar photocatalytic pathogenic disinfection:Fundamentals to state-of-the-art
9
作者 Leena V.Bora 《Water Science and Engineering》 EI CAS CSCD 2023年第2期132-142,共11页
It is necessary to treat pathogen-infected water before its utilisation.Of conventionally used treatment methods,solar photocatalysis has gained considerable momentum owing to its operational simplicity and capacity t... It is necessary to treat pathogen-infected water before its utilisation.Of conventionally used treatment methods,solar photocatalysis has gained considerable momentum owing to its operational simplicity and capacity to use freely and abundantly available solar energy.This article systematically reviewed the disinfection of water with photocatalysis.It addressed the concerns of microbial infection of water and the fundamentals behind its treatment with photocatalysis.It presented an in-depth description of pathogenic deactivation with powerful reactive oxygen species.Special emphasis was given to process intensification as it is an attractive technique that provides multifunctionality and/or equipment miniaturisation.Solar reactor design regarding mobilised/immobilised photocatalysts and compound parabolic concentrators were elucidated.Finally,key parameters governing photoperformance,corresponding trade-offs,and the need for their optimisation were discussed.Overall,this article is a single point of reference for researchers,environmentalists,and industrialists who address the ever-severing challenge of providing clean water whilst also maintaining energy sustainability. 展开更多
关键词 Water Solar light Photocatalysis PATHOGEN E.coli INTENSIFICATION PHOTOREACTOR disinfection
下载PDF
Effectiveness of Disinfection in Bacteriology Laboratories in Togo, 2021
10
作者 Wemboo Afiwa Halatoko Bawimodom Bidjada +10 位作者 Ghislain Emmanuel Sopoh Pirenam Kpaïkpaï Fagdéba David Bara Kokou Akpanta Zoulkarneiri Issa Koffi Akolly Yao Adodo Sadji Gnatoulma Katawa Mounerou Salou Simplice Damintoti Karou Edgard Marius Ouendo 《Open Journal of Preventive Medicine》 2023年第7期213-226,共14页
Background: Laboratory personnel is at risk of biological contamination leading to laboratory-acquired infections (LAIs). The use of disinfection products is essential in the prevention of these infections. This work ... Background: Laboratory personnel is at risk of biological contamination leading to laboratory-acquired infections (LAIs). The use of disinfection products is essential in the prevention of these infections. This work aimed to evaluate the effectiveness of antimicrobial agents used in disinfection in bacteriology laboratories in Togo. Methods: This was a cross-sectional study conducted from June to December 2021 in all bacteriology laboratories in Togo. Swabs taken before and after disinfection of surfaces and staff hands were immediately plated on agar media. Counting and identification of isolated colonies were done after 24 hours of incubation. The ANOVA test was used to compare calculated means, prevalence ratio (PR) and 95% confidence intervals (CI) to compare bacterial frequencies. Results: A total of 393 samples were taken, of which 41.2% were from hands. Before disinfection, surfaces were more contaminated than hands with respectively 40.4% and 29.6% (PR = 1.3;CI 95% = [0.9 - 1.9]). After surface disinfection with 0.5% of chlorine solution, bacterial elimination was total, but partial on hands washed with soap, with residual contamination of 3.7%. A total of 108 strains were isolated before disinfection of which Klebsiella spp. 38.9% and Staphylococcus spp. 25.0%;after disinfection 4 strains were isolated of which: Staphylococcus spp. 75.0% and Klebsiella spp. 25.0%. Conclusion: Surface disinfection was more effective than hand washing with soap and water. We recommend proper hand washing. 展开更多
关键词 EFFECTIVENESS Antimicrobial Agents disinfection HANDS Surfaces
下载PDF
Prevalence and Disinfection of Bacteria Associated with Various Types of Wristbands
11
作者 Joseph Mendonca Belen Wertheimer +4 位作者 Daynalee Dixon Bodhi Stone Karim Dawkins Miranda Christian Nwadiuto Esiobu 《Advances in Infectious Diseases》 2023年第2期193-209,共17页
The potential role of personal items in the transmission of pathogens is poorly understood. In this study, we cultured bacteria of public health importance found on wristbands, determined whether there is a correlatio... The potential role of personal items in the transmission of pathogens is poorly understood. In this study, we cultured bacteria of public health importance found on wristbands, determined whether there is a correlation between wristband material and prevalence, and tested three household disinfectants for efficacy in reducing bacteria on wristbands made of plastic, rubber, metal, and cloth, using standard microbiological assays. Total cultivable bacteria, Staphylococci, Enterobacteria (Escherichia coli), and Pseudomonas on 20 smartwatch wristbands were cultured from randomly recruited subjects. Nearly all wristbands (95%) were contaminated, with the highest average numbers of 3.46E+4 cfu/cm<sup>2</sup> and 1.52E+4 cfu/cm<sup>2</sup> on rubber and plastic bands respectively. Metallic gold and silver wristbands had zero to 18 cfu/cm<sup>2</sup>. While the high prevalence of Staphylococcus spp (85% of wristbands)—skin microbiota;was not unexpected, the occurrence of Pseudomonas spp (30%), and enteric bacteria (60%), even at relatively low numbers is of public health significance. Bacterial load on individual subjects varied remarkably with males and females harboring average total bacteria of 4.045 and 3.42 log<sub>10</sub>cfu/cm<sup>2</sup> of wristband, respectively. The most important predictor of wristband bacteria load was the texture of wristband material and activity (hygiene) of the subject at sampling time. Potential pathogens—Staphylococcus aureus (8143 cfu/cm<sup>2</sup>) and Pseudomonas spp. (1126 cfu/cm<sup>2</sup>) were most abundant on cloth and rubber wristbands, respectively, while the presence of the E. coli group was associated with animal handling activity by a veterinarian. Lysol Disinfectant Spray and 70% Ethanol were highly effective regardless of wristband material with >99.99% kill rate and a log cfu/cm<sup>2</sup> reduction of 3 - 4.0 and 3 - 4.5 respectively within 30 seconds. Apple Cider Vinegar (ACV) was not as potent. Only 2 - 3.5 log cfu/cm<sup>2</sup> drop was obtained after 120 seconds of exposure. Further susceptibility assays with standard reference bacteria showed that Lysol and 70% alcohol effectively killed > 99.99% (>8 log CFU drop) of Escherichia coli strain 7001, Staphylococcus aureus strain 6538, and Pseudomonas aeruginosa strain 10662 within 30 seconds of contact. Vinegar had a similar efficacy on the gram negatives but little or no effect on Staph aureus (only a 2-log CFU/ml reduction in 5 minutes!) The high prevalence of potential pathogens, some of which could be reservoirs of antibiotic resistance reveals a weak link in infection control and underscores the need for regular cleaning of personal and hand-held accessories with adequate considerations of their texture. 展开更多
关键词 Apple Cider Vinegar DISINFECTANTS Escherichia coli Lysol Pseudomonas aeruginosa Public Health Staphylococcus aureus Wristbands
下载PDF
The Application Value of Sanitary Wipes and Medical Alcohol+Gauze Disinfection Method in the Management and Use of Medical Equipment
12
作者 Afen Zheng Chunmei Zhang 《Journal of Clinical and Nursing Research》 2023年第6期162-166,共5页
Objective:To analyze the effect of sanitary wipes and medical alcohol+gauze disinfection methods on the management and use of medical equipment in hospitals.Methods:From February 2023 to August 2023,80 anorectal surge... Objective:To analyze the effect of sanitary wipes and medical alcohol+gauze disinfection methods on the management and use of medical equipment in hospitals.Methods:From February 2023 to August 2023,80 anorectal surgery medical instruments and equipment were randomly sampled as observation samples,and they were grouped using the random number table method(40 instruments in each group).One group was managed with sanitary wipes and medical alcohol+gauze disinfection method(observation group),and the other group was managed with medical alcohol+gauze disinfection method(control group).The degree of contamination on the surface of instruments and equipment and the staff satisfaction of both groups was noted and compared.Results:After cleaning and disinfection,the relative luminescence luminosity(RLU)value of the surface contamination of the sample instruments and equipment decreased significantly(P<0.05);and after cleaning and disinfection,the relative luminescence luminosity(RLU)of the observation group’s instruments and equipment decreased significantly,and the value was lower than that of the control group,(P<0.05);the results of the nursing job satisfaction questionnaire showed that the scores of each survey item in the observation group were higher than those in the control group,(P<0.05).Conclusion:Integrating sanitary wipes and medical alcohol+gauze disinfection method into the management and use of medical equipment not only improves the disinfection of medical instruments but also improves the job satisfaction of nursing staff.Therefore,this method should be popularized. 展开更多
关键词 Medical equipment management Sanitary wipes Medical alcohol Gauze disinfection
下载PDF
A prototype for on-site generation of chlorinated disinfectant for use in rural aqueducts
13
作者 Diana Marcela Cuesta Parra Felipe Correa Mahecha +3 位作者 Andrés Felipe Rubio Pinzon Davidcamilo Ramirez Bustos Leonel Alveyro Teran Llorente Miguel Fernando Jimenez Jimenez 《Water Science and Engineering》 EI CAS CSCD 2024年第1期33-40,共8页
Sodium hypochlorite has significant potential as a sanitation solution in hard-to-reach areas.Few studies have investigated the optimal electrolysis parameters for its production with volumes greater than 1o L.This st... Sodium hypochlorite has significant potential as a sanitation solution in hard-to-reach areas.Few studies have investigated the optimal electrolysis parameters for its production with volumes greater than 1o L.This study evaluated sodium hypochlorite production through electrolysis in a 22-L prototype and identified the optimal operating parameters.Tests were performed using graphite electrodes with areas of 68.4 cm²at the laboratory scale and 1865.0 cm?at the prototype scale.A design for experiments with different operating times,chloride concentrations,and electric current intensities was developed.The optimal operating time,sodium chloride concentration,and current intensity at the laboratory scale were 120 min,150 g of chloride per liter,and 3 A,respectively,leading to the production of 5.02 g/L of the disinfectant with an energy efficiency of 12.21 mg of Cl2 per kilojoule.At the prototype scale,the maximum sodium hypochlorite concentration of 3.99 g of chloride per liter was achieved with an operating time of 120 min,a sodium chloride concentration of 100 g of chloride per liter,and a current intensity of 70 A,reaching an energy efficiency of 42.56 mg of Cl2 per kilojoule.In addition,this study evaluated the influences of the chloride concentration,current intensity,and operating time on the production of sodium hypochlorite at the two scales,and formulated the equations showing the trends of sodium hypochlorite production and energy efficiency in the electrochemical systems.The 22-L prototype model for production of this oxidizing substance is promising for disinfection of large volumes of water in areas that are difficult to access. 展开更多
关键词 disinfection ELECTROLYSIS Energy efficiency Optimization Sodium hypochlorite
下载PDF
Antiseptic Efficacy of A Soap Made from Biosurfactants Isolated from Bacillus and Lactobacillus against Pathogenic Bacteria
14
作者 Frédéric Yannick Okouakoua Christian Aimé Kayath +10 位作者 Nicaise Saturnin Mokémiabeka Varelle Bervanie Ngala Elenga Digne Nedjea N’goma-Mona Ndelani Nkalla Lambi Sandra Paola Elenga Wilson Christ Dieuveil Bayakissa Malanda Rodinet Tsana Junior Patrick Sergy Bissoko1 Moïse Doria Kaya-Ongoto Duchel Jeanedvi Kinavouidi Etienne Nguimbi 《Advances in Microbiology》 CAS 2024年第1期31-58,共28页
The aim of our study was to use a biosurfactant produced by Bacillus and Lactobacillus isolates as an antiseptic in the formulation of local soap. A total of 60 isolates were characterized by microbiological technique... The aim of our study was to use a biosurfactant produced by Bacillus and Lactobacillus isolates as an antiseptic in the formulation of local soap. A total of 60 isolates were characterized by microbiological techniques (30 Bacillus and 30 Lactobacillus) and the ability to produce biosurfactants was demonstrated by a hydrocarbon emulsification index (E24). The emulsification indexes (E24) varied from 9% to 100% for Bacillus and from 33% to 100% for Lactobacillus as well. The antagonistic assay showed that biosurfactants were able to inhibit the formation of biofilms and growth of pathogens such as Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, Bacillus cereus, Salmonella typhirium, Shigella boydii and Proteus mirabilis. The biosurfactant consortium (BioC) from Bacillus consortium and from Lactobacillus was able to inhibit biofilm formation and the pathogens growth. The BioC was stable to alkaline pH and the temperatures stability of Biosurfactant was ranging from 50°C to 90°C. The soap was made by the cold saponification process using one biosurfactant consortium formulated. This soap has a pH of 10 and showed good cleaning power and good foam stability. Similarly, the soap showed good antiseptic power and disinfection power against all pathogens tested. Handwashing is critical to preventing disease transmission. The persistence of pathogens in waste water was evaluated. The BioS produced showed good disinfection power against all pathogens tested. The valor of reduction on the hands and in the waste water was significantly more than compared to the control soaps used. This soap could be used in the prevention, fighting, and treatment of bacterial and viral infections. 展开更多
关键词 ANTISEPTIC SOAP Biosurfactants BACILLUS LACTOBACILLUS disinfection Pathogens bacteria
下载PDF
A Natural Catalytic Converter® for Continuously Inactivating Air and Surface Pathogens with More Effect than Ventilation and Filtration
15
作者 Margaret Scarlett Brett Duffy 《Open Journal of Applied Sciences》 2024年第5期1353-1363,共11页
Study Objective: The purpose of the study is to present independent laboratory testing for a novel technology in air and on surfaces. Since 2020, public health goals have focused on improving indoor air quality. This ... Study Objective: The purpose of the study is to present independent laboratory testing for a novel technology in air and on surfaces. Since 2020, public health goals have focused on improving indoor air quality. This includes protection from airborne pathogens, such as tuberculosis, RSV, SARS-CoV-2, common cold or influenza viruses, measles, and others. Engineering controls are highly effective at reducing hazardous pathogens found in indoor air and from recontamination of surfaces. This occurs from a continuous cycle of settling of small, sustained airborne pathogens, which may become dehumidified, becoming airborne again, carried by room air currents around indoor spaces, then repeating the cycle. Methods: The novel technology utilizes a catalytic process to produce safe levels of hydrogen peroxide gas that are effective in reducing pathogens in the air and on surfaces. Air testing was performed with the MS2 bacteriophage, the test organism for ASHRAE standard 241, and methicillin-Resistant Staphylococcus aureus (MRSA). Surface testing was performed with SARS-COV-2 (Coronavirus COVID-19) and H1N1 (Influenza). Typical ventilation and filtration does not effectively remove disbursed pathogens from the entire facility, due to inconsistent air circulation and surface deposits of pathogens. Results: MS2 was reduced by 99.9%;MRSA was reduced by 99.9%;SARS-CoV-2 was reduced by 99.9%;H1N1 was reduced by 99.9%. Conclusion: This novel catalytic converter reduces a variety of pathogens in the air (99%) and on surfaces (99%), by actively disinfecting with the introduction of gaseous hydrogen peroxide. This active disinfection provides a strong solution for protecting the entire facility and its occupants. 展开更多
关键词 PATHOGEN Bacteria Virus Reduction Gaseous Hydrogen Peroxide disinfection Indoor Air Quality SURFACE
下载PDF
Characterization of dissolved organic matter fractions and its relationship with the disinfection by-product formation 被引量:13
16
作者 ZHANG Hua QU Jiuhui +1 位作者 LIU Huijuan WEI Dongbin 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2009年第1期54-61,共8页
Dissolved organic matter (DOM) has been identified as precursor for disinfection by-products (DBPs) formation during chlorination. Recently, it has been demonstrated that the characteristics of DOM influence the D... Dissolved organic matter (DOM) has been identified as precursor for disinfection by-products (DBPs) formation during chlorination. Recently, it has been demonstrated that the characteristics of DOM influence the DBPs formation mechanism. A study was, therefore, initiated to investigate the effects of DOM fractions on DBPs formation mechanism. In the chlorination process, organic acids are dominant precursors of total thihalomethanes (TTHM) because of the vc-o and unsaturated structures. Furthermore, the TTHM formation of organic acids was affected by pH more greatly. Based on the fluorescence spectroscopy analysis, DOM fractions contained several fluorescence substances. During chlorination, humic acid-like substances were found to exhibit high chlorine reactivity and hydrophobic organics decomposed to smaller molecules faster than hydrophilic organics even at lower chlorine dosages. Unlike hydrophobic fractions, hydrophilic organics showed no toxicity following chlorination, suggesting that the toxic structures in hydrophihc organics showed high chlorine reactivity during chlorination. 展开更多
关键词 disinfection by-products CHLORINATION CHARACTERISTICS dissolved organic matter
下载PDF
Growth and Repair Potential of Three Species of Bacteria in Reclaimed Wastewater after UV Disinfection 被引量:8
17
作者 GUO MeiTing HUANG JingJing +1 位作者 HU HongYing LIU WenJun 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2011年第4期400-407,共8页
关键词 Wastewater reclamation UV disinfection GROWTH REPAIR Photo-reactivation Dark repair
下载PDF
Waste Water Disinfection During SARS Epidemic for Microbiological and Toxicological Control 被引量:5
18
作者 CHAO CHEN XIAO-JIAN ZHANG YUN WANG LING-XIA ZHU JING LIU 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2006年第3期173-178,共6页
关键词 Wastewater disinfection CHLORINE Chlorine dioxide Ozone Ultraviolet disinfection by-products
下载PDF
Simultaneous Control of Microorganisms and Disinfection By-products by Sequential Chlorination 被引量:4
19
作者 CHAO CHEN XIAO-JIAN ZHANG +1 位作者 WEN-JIE HE HONG-DA HAN 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2007年第2期119-125,共7页
Objective To introduce a new sequential chlorination disinfection process in which short-term free chlorine and chloramine are sequentially added. Methods Pilot tests of this sequential chlorination were carried out i... Objective To introduce a new sequential chlorination disinfection process in which short-term free chlorine and chloramine are sequentially added. Methods Pilot tests of this sequential chlorination were carried out in a drinking water plant. Results The sequential chlorination disinfection process had the same or better efficiency on microbe (including virus) inactivation compared with the free chlorine disinfection process. There seemed to be some synergetic disinfection effect between free chlorine and monochloramine because they attacked different targets. The sequential chlorination disinfection process resulted in 35.7%-77.0% TTHM formation and 36.6%-54.8% THAA5 formation less than the free chlorination process. The poorer the water quality was, the more advantage the sequential chlorination disinfection had over the free chlorination. Conclusion This process takes advantages of free chlorine's quick inactivation of microorganisms and chloramine's low disinfection by-product (DBP) yield and long-term residual effect, allowing simultaneous control of microbes and DBPs in an effective and economic way. 展开更多
关键词 disinfection Free chlorine CHLORAMINE disinfection by-products MICROORGANISMS
下载PDF
Formation potentials of typical disinfection byproducts and changes of genotoxicity for chlorinated tertiary effluent pretreated by ozone 被引量:3
20
作者 CAO Nan MIAO Tingting +2 位作者 LI Kuixiao ZHANG Yu YANG Min 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2009年第4期409-413,共5页
The effects of ozonation on the formation potential of typical disinfection byproducts (DBPs) and the changes of genotoxicity during post chlorination of tertiary effluent from a sewage treatment plant were investig... The effects of ozonation on the formation potential of typical disinfection byproducts (DBPs) and the changes of genotoxicity during post chlorination of tertiary effluent from a sewage treatment plant were investigated. Ozonation enhanced the yields of all detected chlorine DBPs except CHCI3. At a chlorine dose of 5 mg/L, the three brominated THMs and five HAAs increased, while chloroform decreased with the increase of ozone dose from 0 to 10 mg/L (ozone dose in consumption base). At a chlorine dose of 10 mg/L, the two mixed bromochloro species THMs and two dominant HAAs (DCAA and TCAA) increased firstly and then decreased with the increase of ozone dose, with the turning point approximately occurring at an ozone dose of 5 mg/L. The genotoxicity detected using umu test, on the other hand, was removed from 7 Ixg 4-NQO/L to a negligible level by ozonation under an ozone dose of 5 mg/L. Chlorination could further remove the genotoxicity to some extent. It was found that SUVA (UV absorbance divided by DOC concentration) might be used as an indicative parameter for monitoring the removal of genotoxicity during the oxidation. 展开更多
关键词 wastewater reclamation OZONATION CHLORINATION disinfection byproducts GENOTOXICITY
下载PDF
上一页 1 2 17 下一页 到第
使用帮助 返回顶部