期刊文献+
共找到2,245篇文章
< 1 2 113 >
每页显示 20 50 100
Simultaneous determination of free methamphetamine,pethidine,ketamine and tramadol in urine by dispersive liquid–liquid microextraction combined with GC–MS 被引量:3
1
作者 Fangmin Xu Lingyun Liu 《Forensic Sciences Research》 CSCD 2019年第2期188-194,共7页
A simple and rapid dispersive liquid–liquid microextraction(DLLME)technique coupled with gas chromatography–ion trap mass spectrometry(GC–MS)was developed for the extraction and analysis of methamphetamine(MA),peth... A simple and rapid dispersive liquid–liquid microextraction(DLLME)technique coupled with gas chromatography–ion trap mass spectrometry(GC–MS)was developed for the extraction and analysis of methamphetamine(MA),pethidine(PD),ketamine(KT)and tramadol(TD)from human urine.In this study,different parameters affecting the extraction process such as the type and volume of extraction solvent,type and volume of disperser solvent,extraction time and pH value and salt effect were studied and optimized.Under optimized conditions,the enrichment factor ranged from 185 to 226 and the average recovery ranged from 80.45%to 95.55%.The linear range was 10.0–1000.0 mg/L,the limit of detection and quantitation were in the range 0.43–1.96 mg/L and 1.44–6.53 mg/L,respectively.The relative standard deviations were in the range 1.98%–3.90%(n=7).The obtained results show that DLLME combined with GC–MS is a fast and simple method for the determination of MA,PD,KT and TD in human urine. 展开更多
关键词 Forensic science forensic toxicology dispersive liquid–liquid microextraction gas chromatography mass spectrometry urine drug abuse sample pretreatment
原文传递
Dispersive liquid–liquid microextraction of silver nanoparticles in water using ionic liquid1-octyl-3-methylimidazolium hexafluorophosphate 被引量:2
2
作者 Sha Chen Yuanjing Sun +3 位作者 Jingbo Chao Liping Cheng Yun Chen Jingfu Liu 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2016年第3期211-217,共7页
Using the ionic liquid(IL)1-octyl-3-methylimidazolium hexafluorophosphate as the extractant and methanol as the dispersion solvent,a dispersive liquid–liquid microextraction method was developed to extract silver n... Using the ionic liquid(IL)1-octyl-3-methylimidazolium hexafluorophosphate as the extractant and methanol as the dispersion solvent,a dispersive liquid–liquid microextraction method was developed to extract silver nanoparticles(AgN Ps)from environmental water samples.Parameters that influenced the extraction efficiency such as IL concentration,pH and extraction time were optimized.Under the optimized conditions,the highest extraction efficiency for AgN Ps was above 90% with an enrichment factor of 〉90.The extracted AgN Ps in the IL phase were identified by transmission electron microscopy and ultraviolet–visible spectroscopy,and quantified by inductively coupled plasma mass spectrometry after microwave digestion,with a detection limit of 0.01 μg/L.The spiked recovery of AgN Ps was 84.4% with a relative standard deviation(RSD)of 3.8%(n = 6)at a spiked level of 5 μg/L,and 89.7% with a RSD of 2.2%(n = 6)at a spiked level of 300 μg/L,respectively.Commonly existed environmental ions had a very limited influence on the extraction efficiency.The developed method was successfully applied to the analysis of Ag NPs in river water,lake water,and the influent and effluent of a wastewater treatment plant,with recoveries in the range of 71.0%–90.9% at spiking levels of 0.11–4.7 μg/L. 展开更多
关键词 Silver nanoparticle 1-Octyl-3-methylimidazolium hexafluorophosphate Ionic liquid dispersive liquid–liquid microextraction
原文传递
Ionic liquid based dispersive liquid-liquid microextraction of aromatic amines in water samples 被引量:13
3
作者 Yun Chang Fan Zheng Liang Hu +2 位作者 Mei Lan Chen Chao Shen Tu Yan Zhu 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第8期985-987,共3页
In this work, a new microextraction method termed ionic liquid based dispersive liquid-liquid microextraction (IL-DLLME) was demonstrated for the extraction of 2-methylaniline, 4-chloroaniline, 1-naphthylamine and 4... In this work, a new microextraction method termed ionic liquid based dispersive liquid-liquid microextraction (IL-DLLME) was demonstrated for the extraction of 2-methylaniline, 4-chloroaniline, 1-naphthylamine and 4-aminobiphenyl in aqueous matrices. After extraction the ionic liquid (IL) phase was injected directly into the high performance liquid chromatography (HPLC) system for determination. Some parameters that might affect the extraction efficiency were optimized. Under the optimum conditions, good linear relationship, sensitivity and reproducibility were obtained. The limits of detection (LOD, S/N = 3) for the four analytes were in the range of 0.45-2.6 μg L^-1. The relative standard deviations (R.S.D., n = 6) were in the range of 6.2-9.8%. This method was applied for the analysis of the real water samples. The recoveries ranged from 93.4 to 106.4%. The main advantages of the method are high speed, high recovery, good repeatability and volatile organic solvent-free. 展开更多
关键词 Ionic liquid (IL) dispersive liquid-liquid microextraction (DLLME) High performance liquid chromatography (HPLC) Aromatic amines
下载PDF
Novel method for the determination of five carbamate pesticides in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography 被引量:10
4
作者 Zhi Mei Liu Xiao Huan Zang Wei Hua Liu Chun Wang Zhi Wang 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第2期213-216,共4页
A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) ... A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-diode array detector (HPLC-DAD). Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results. Under the optimum conditions for the method, the calibration curve was linear in the concentration range from 5 to 1000 ng mL^-1 for all the five carbamate pesticides, with the correlation coefficients (r^2) varying from 0.9984 to 0.9994. Good enrichment factors were achieved ranging from 80 to 177- fold, depending on the compound. The limits of detection (LODs) (S/N = 3) were ranged from 0.1 to 0.5 ng mL^-1. The method has been successfully applied to the analysis of the pesticide residues in environmental water samples. 展开更多
关键词 Carbamate pesticides High performance liquid chromatography Diode array detection dispersive liquid-liquid microextraction Water samples
下载PDF
Dispersive Liquid-liquid Microextraction Combined with High-performance Liquid Chromatography for the Determination of Clozapine and Chlorpromazine in Urine 被引量:3
5
作者 陈静 熊朝梅 +1 位作者 阮金兰 苏邹 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2011年第2期277-284,共8页
A simple method has been proposed for the determination of clozapine (CLZ) and chlorpromazine (CPZ) in human urine by dispersive liquid-liquid microextraction (DLLME) in combination with high-performance liquid ... A simple method has been proposed for the determination of clozapine (CLZ) and chlorpromazine (CPZ) in human urine by dispersive liquid-liquid microextraction (DLLME) in combination with high-performance liquid chromatography-ultraviolet detector (HPLC-UV). All important variables influencing the extraction efficiency, such as pH, types of the extraction solvent and the disperser solvent and their volume, ionic strength and centrifugation time were investigated and optimized. Under the optimal conditions, the limit of detection (LODs) and quantification (LOQs) of the method were 13 and 39 ng/mL for CLZ, and 2 and 6 ng/mL for CPZ, respectively. The relative standard deviations (RSDs) of the targets were less than 5.1% (C=0.100 μg/mL, n=9). Good linear behaviors over the tested concentration ranges were obtained with the values of R20.999 for the targets. The absolute extraction efficiencies of CLZ and CPZ from the spiked blank urine samples were 98.3% and 97.8%, respectively. The applicability of the technique was validated by analyzing urine samples and the mean recoveries for spiked urine samples ranged from 93.3% to 105.0%. The method was successfully applied for the determination of CLZ and CPZ in real human urine. 展开更多
关键词 dispersive liquid-liquid microextraction CLOZAPINE CHLORPROMAZINE high-performance liquid chromatography human urine
下载PDF
Determination of Amitraz in the Honey Samples by Dispersive Liquid-Liquid Microextraction Followed by Gas Chromatography—Flame Ionization Detection 被引量:4
6
作者 Mostafa Bashiri-Juybari Ali Mehdinia +1 位作者 Ali Jabbari Yadollah Yamini 《American Journal of Analytical Chemistry》 2011年第5期632-637,共6页
Dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography–flame ionization detection (GC-FID), as a simple, rapid and efficient method, was developed for the determination of amitraz in honey sa... Dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography–flame ionization detection (GC-FID), as a simple, rapid and efficient method, was developed for the determination of amitraz in honey samples. This method involves the use of an appropriate mixture of the extraction and disperser solvents for the formation of a cloudy solution in 5.0 mL aqueous sample containing amitraz. After extraction, phase separation was performed by centrifugation and the concentrated amitraz in the sedimented phase was determined by gas chromatography—flame ionization detection (GC-FID). Some important parameters such as the type and volume of extraction and disperser solvents, and the effect of pH and salt on the extraction recovery of amitraz were investigated. Under the optimum conditions (13 μL of carbon tetrachloride as an extraction solvent, 1 mL of acetonitrile as a disperser solvent, no salt addition and pH 6) preconcentration factor and the extraction recovery were 955 and 95.5%, respectively. The linear range was 0.01 - 1.0 mg?kg–1 and the limit of detection was 0.0015 mg?kg–1. The relative standard deviation (RSD, n = 4) for 0.1 mg?kg–1 of amitraz was 3.2%. The recoveries of amitraz from honey samples at the spiking levels of 0.1 mg?kg-1 were 78.8 and 98.2%. The results indicated that DLLME is an efficient technique for the extraction of amitraz in honey samples. 展开更多
关键词 dispersive liquid–liquid microextraction AMITRAZ HONEY Sample
下载PDF
Utilization of Dispersive Liquid-Liquid Microextraction Coupled with HPLC-UV as a Sensitive and Efficient Method for the Extraction and Determination of Oleanolic Acid and Ursolic Acid in Chinese Medicinal Herbs 被引量:2
7
作者 Yaomei Hao Xuan Chen +2 位作者 Shuang Hu Xiaohong Bai Deshuang Gu 《American Journal of Analytical Chemistry》 2012年第10期675-682,共8页
Isomeric triterpenic acids of oleanolic acid (OA) and ursolic acid (UA) both have very low ultraviolet absorption and always exist in the same plant, so the separation and simultaneous determination of them have been ... Isomeric triterpenic acids of oleanolic acid (OA) and ursolic acid (UA) both have very low ultraviolet absorption and always exist in the same plant, so the separation and simultaneous determination of them have been a difficult task. In this study, a sensitive method combining dispersive liquid-liquid microextraction (DLLME) with HPLC-UV was developed for the extraction and determination of OA and UA in traditional Chinese medicinal herbs (CMHs). Variables influencing DLLME such as type and volume of extraction solvent, volume of dispersive solvent, ionic strength, aqueous phase pH, extraction time, centrifugation speed and time, and sample volume were investigated and optimized. Under the optimum conditions, both OA and UA attained favorable extraction efficiencies with enrichment factors 1378 and 933, respectively. The linear dynamic ranges of 0.07 - 30.4 μg?mL–1 for OA and 0.08 - 33.6 μg?mL–1 for UA were obtained with square correlation coefficients of 0.9963. The detection limits of OA and UA were both 0.02 μg?mL–1. The method recoveries ranged between 88.2% - 116.2% for OA and 85.7% - 108.2% for UA with the RSDs (n = 5) lower than 8.6%. The proposed method was successfully applied to concentrate and simultaneously determine these two triterpenic acids in Hedyotis diffusa and Eriobotrya japonica samples. 展开更多
关键词 dispersive liquid-liquid microextraction High Performance liquid Chromatography Enrichment Factor Triterpenic ACIDS Chinese MEDICINAL HERBS
下载PDF
Determination of Cobalt in Food, Environmental and Water Samples with Preconcentration by Dispersive Liquid-Liquid Microextraction 被引量:1
8
作者 Catalina Bosch Ojeda Fuensanta Sánchez Rojas José Manuel Cano Pavón 《American Journal of Analytical Chemistry》 2012年第2期125-130,共6页
A new method for the determination of cobalt was developed by dispersive liquid-liquid microextraction preconcentra-tion and flame atomic absorption spectrometry. In the proposed approach, 1,5-bis(di-2-pyridyl) methyl... A new method for the determination of cobalt was developed by dispersive liquid-liquid microextraction preconcentra-tion and flame atomic absorption spectrometry. In the proposed approach, 1,5-bis(di-2-pyridyl) methylene thiocarbohydrazide (DPTH) was used as a chelating agent, and chloroform and ethanol were selected as extraction and dispersive solvents. Some factors influencing the extraction efficiency of cobalt and its subsequent determination, including extraction and dispersive solvent type and volume, pH of sample solution, concentration of the chelating agent, and extraction time, were studied and optimized. Under the optimum conditions, a preconcentration factor of 8 was reached. The detection limit for cobalt was 12.4 ng?mL–1, and the relative standard deviation (RSD) was 3.42% (n = 7, c = 100 ng?mL–1). The method was successfully applied to the determination of cobalt in food, environmental and water samples. 展开更多
关键词 COBALT dispersive liquid-liquid microextraction Flame Atomic Absorption Spectrometry Water ENVIRONMENTAL and FOOD Samples
下载PDF
Evaluation of Response Surface Methodology in Dispersive Liquid-Liquid Microextraction for Lead Determination Using Ionic Liquids
9
作者 Behrooz Majidi Farzaneh Shemirani Rouhollah Khani 《American Journal of Analytical Chemistry》 2011年第8期892-901,共10页
This paper describes a dispersive liquid–liquid microextraction (DLLME) procedure using room temperature ionic liquids (RTILs) coupled with flame atomic absorption spectrometry detection with microsample intro-ductio... This paper describes a dispersive liquid–liquid microextraction (DLLME) procedure using room temperature ionic liquids (RTILs) coupled with flame atomic absorption spectrometry detection with microsample intro-duction system capable of quantifying trace amounts of lead. In the proposed approach, ammonium pyr-rolidine dithiocarbamate (APDC) was used as a chelating agent and 1-hexyl-3-methylimmidazolium bis (trifluormethylsulfonyl)imid as an extraction solvent was dissolved in acetone as the disperser solvent. The binary solution was then rapidly injected by a syringe into the water sample containing Pb2+ complex. Some factors influencing the extraction efficiency of Pb2+ and its subsequent determination, including extraction and dispersive solvent type, pH of sample solution, concentration of the chelating agent and salt effect were inspected by a full factorial design to identify important parameters and their interactions. Next, a central composite design was applied to obtain the optimum points of the important parameters. Under the optimum conditions, the limit of detection (LOD) was 0.2 μg/L. The relative standard deviation (R.S.D) was 1.4% for 5 μg/L of Pb2+ (n = 7). The relative recovery of lead in seawater, blood, tomato and black tea samples was measured. 展开更多
关键词 IONIC liquid dispersive liquid-liquid microextraction Microsample INJECTION Experimental Design
下载PDF
Determination of five endosulfan pesticides in the fish pond water by dispersive liquid–liquid microextraction combined with GC–MS
10
作者 Fangmin Xu Lingyun Liu +1 位作者 Wanli Wei Ruolun Xu 《Forensic Sciences Research》 2017年第1期40-45,共6页
A simple and rapid dispersive liquid-liquid microextraction(DLLME)technique coupled with gas chromatography-ion trap mass spectrometry(GC-MS)was developed for the extraction and analysis of five endosulfan pesticides ... A simple and rapid dispersive liquid-liquid microextraction(DLLME)technique coupled with gas chromatography-ion trap mass spectrometry(GC-MS)was developed for the extraction and analysis of five endosulfan pesticides from the fish pond water.In this work,different parameters affecting the extraction process such as the type and volume of extraction solvent,type and volume of disperser solvent,and extraction time were studied and optimized.Under optimized conditions,the enrichment factor ranged from 189 to 269 and the relative recovery ranged from 88.5%to 94.9%.The linear range was 2.0-80.0 mg/L;the limits of detection and quantitation were in the range 0.04-1.06 mg/L and 0.12-3.53 mg/L,respectively.The relative standard deviations were in the range 0.94%-2.08%(n D 5).The obtained results show that DLLME combined with GC-MS is a fast and simple method for the determination of endosulfan pesticides in fish pond water. 展开更多
关键词 Forensic science forensic toxicology gas chromatography–mass spectrometry liquid–liquid microextraction analytic sample preparation methods ENDOSULFAN PESTICIDES fish pond water
原文传递
Enhancement of Sensitivity for Determination of Phenols in Environmental Water Samples by Single-drop Liquid Phase Microextraction Using Ionic Liquid prior to HPLC 被引量:5
11
作者 Qing Xiang ZHOU Jun Ping XIAO +1 位作者 Cun Ling YE Xin Ming WANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第8期1073-1076,共4页
A single-drop liquid phase micro-extraction procedure using 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) was demonstrated for the sensitive determination of four phenols in water samples. Under the... A single-drop liquid phase micro-extraction procedure using 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) was demonstrated for the sensitive determination of four phenols in water samples. Under the optimized conditions, the linear range of proposed method was excellent in the range of 0.5-100 μg·L^-1, the reproducibility (RSD, n=6) were in the range 5.4%-8.9% and detection limits (S/N=3) were 0.3, 0.3, 0.5 and 0.5 μg·L^-1 for 2, 4-dichlorophenol, 2-naphthol, 2-nitrophenol and 4-chlorophenol, respectively. The experimental results indicated that the effect of complex matrices natural water samples could be resolved with addition of sodium ethylene diamine tetracetate (EDTA) into the samples. Excellent spiked recoveries were achieved for these four phenols ranged from 86.2%-114.9 %. All these facts demonstrated that the proposed method with merits of low cost, simplicity and easy operating would be a competitive alternative procedure for the determination of such compounds at trace level. 展开更多
关键词 1-Butyl-3-methylimidazolium hexafluorophosphate single-drop liquid phase microextraction phenols.
下载PDF
Hollow fiber-based liquid phase microextraction followed by analytical instrumental techniques for quantitative analysis of heavy metal ions and pharmaceuticals 被引量:2
12
作者 Wajid Ali Khan Muhammad Balal Arain +4 位作者 Yadollah Yamini Nasrullah Shah Tasneem Gul Kazi Stig Pedersen-Bjergaard Mohammad Tajik 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2020年第2期109-122,共14页
Hollow-fiber liquid-phase microextraction(HF-LPME)and electromembrane extraction(EME)are miniaturized extraction techniques,and have been coupled with various analytical instruments for trace analysis of heavy metals,... Hollow-fiber liquid-phase microextraction(HF-LPME)and electromembrane extraction(EME)are miniaturized extraction techniques,and have been coupled with various analytical instruments for trace analysis of heavy metals,drugs and other organic compounds,in recent years.HF-LPME and EME provide high selectivity,efficient sample cleanup and enrichment,and reduce the consumption of organic sol-vents to a few micro-liters per sample.HF-LPME and EME are compatible with different analytical in-struments for chromatography,electrophoresis,atomic spectroscopy,mass spectrometry,and electrochemical detection.HF-LPME and EME have gained significant popularity during the recent years.This review focuses on hollow fiber based techniques(especially HF-LPME and EME)of heavy metals and pharmaceuticals(published 2017 to May 2019),and their combinations with atomic spectroscopy,UV-VIS spectrophotometry,high performance liquid chromatography,gas chromatography,capillary elec-trophoresis,and voltammetry. 展开更多
关键词 HOLLOW fiber liquid phase microextraction Electromembrane extraction HEAVY metals Pharmaceuticals INSTRUMENTAL TECHNIQUES
下载PDF
Dynamic microwave-assisted extraction combined with liquid phase microextraction based on the solidification of a floating drop for the analysis of organochlorine pesticides in grains followed by GC 被引量:4
13
作者 Guijie Li Xu Zhang +5 位作者 Tingting Liu Hongxiu Fan Hongcheng Liu Shangyu Li Dawei Wang Lan Ding 《Food Science and Human Wellness》 SCIE 2021年第3期375-382,共8页
A convenient,cost-effective and fast method using dynamic microwave-assisted extraction and liquid phase microextraction based on the solidification of a floating drop was proposed to analyze organochlorine pesticides... A convenient,cost-effective and fast method using dynamic microwave-assisted extraction and liquid phase microextraction based on the solidification of a floating drop was proposed to analyze organochlorine pesticides in grains including rice,maize and millet.Twelve samples can be processed simultaneously in the method.During the extraction process,10%acetonitrile-water solutions containing 110μL of n-hexadecane were used to extract organochlorine pesticides.Subsequently,1.0 g sodium chloride was placed in the extract,and then centrifuged and cooled.The n-hexadecane drops containing the analytes were solidifi ed and transferred for determination by gas chromatography-electron capture detector without any further filtration or cleaning process.Limits of detection for organochlorine pesticides were 0.97–1.01μg/kg and the RSDs were in the range of 2.6%–8.5%.The developed technology has succeeded in analyzing six real grains samples and the recoveries of the organochlorine pesticides were 72.2%–94.3%.Compared with the published extraction methods,the developed method was used to analyze organochlorine pesticides in grains,being more environmentally friendly,which is suitable for the daily determination of organochlorine pesticides. 展开更多
关键词 Dynamic microwave-assisted extraction liquid phase microextraction Gas chromatography Organochlorine pesticides Grain
下载PDF
Rapid determination of atrazine in environmental water samples by a novel liquid phase microextraction 被引量:1
14
作者 Qing Xiang Zhou Guo Hong Xie Long Pang 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第1期89-91,共3页
A novel method was described for the rapid determination of atrazine using dispersive liquid phase microextraction in combination with high performance liquid chromatography (HPLC). Possible impact parameters such a... A novel method was described for the rapid determination of atrazine using dispersive liquid phase microextraction in combination with high performance liquid chromatography (HPLC). Possible impact parameters such as sample pH, extraction and disperser solvents, salting-out effect, and extraction time were investigated. The experimental results indicated that proposed method possessed an excellent analytical performance, The linear range, detection limit, and precision (R.S.D.) were 0.1- 50 ng mL- 1 (R2 = 0.9955), 0.601 ng mL- 1 and 6,4%, respectively. The proposed method was validated with the real water samples, and the spiked recoveries were in the range of 69.9-89.8%, respectively. These results indicated that the established method with high enrichment factor, short extraction time was an excellent alternative for the routine analysis of atrazine in environmental samples. 2007 Qing Xiang Zhou. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved. 展开更多
关键词 liquid phase microextraction ATRAZINE High performance liquid chromatography Water samples
下载PDF
Pre-concentration and determination of amitriptyline residues in waste water by ionic liquid based immersed droplet microextraction and HPLC 被引量:1
15
作者 M.T.Hamed Mosavian Z.Es’haghi +1 位作者 N.Razavi S.Banihashemi 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第5期361-365,共5页
This paper describes a new approach for the determination of amitriptyline in wastewater by ionic liquid based immersed droplet microextraction (IL-IDME) prior to highperformance liquid chromatography with ultraviol... This paper describes a new approach for the determination of amitriptyline in wastewater by ionic liquid based immersed droplet microextraction (IL-IDME) prior to highperformance liquid chromatography with ultraviolet detection. 1-Hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) was used as an ionic liquid. Various factors that affect extraction, such as volume of ionic liquid, stirring rate, extraction time, pH of the aqueous solution and salting effect, were optimized. The optimal conditions were as follows: microextraction time, 10 min; stirring rate, 720 rpm; pH, 11; ionic drop volume, 100 uL; and no sodium chloride addition. In quantitative experiments the method showed linearity in a range from 0.01 to 10 ug/mL, a limit of detection of 0.004 ug/mL and an excellent pre-concentration factor (PF) of 1100. Finally, the method was successfully applied to the determination of amitriptyline in the hospital wastewater samples. 展开更多
关键词 Antidepressant Ionic liquid based immersed droplet microextraction (IL-IDME) High performance liquid chromatography(HPLC)
下载PDF
Ionic Liquid-Based Ultrasound-Assisted Emulsification Microextraction Coupled with HPLC for Simultaneous Determination of Glucocorticoids and Sex Hormones in Cosmetics 被引量:1
16
作者 Xiaoji Cao Lingxiao Shen +3 位作者 Xuemin Ye Feifei Zhang Jiaoyu Chen Weimin Mo 《Green and Sustainable Chemistry》 2013年第2期26-31,共6页
An effective and environmentally friendly method based on ionic liquid-based ultrasound-assisted emulsification microextraction(IL-USAEME) and high performance liquid chromatography (HPLC) has been developed for the d... An effective and environmentally friendly method based on ionic liquid-based ultrasound-assisted emulsification microextraction(IL-USAEME) and high performance liquid chromatography (HPLC) has been developed for the determination of nine hormones including three glucocorticoids, one androgen and five progestogens in cosmetics. Several factors that affect the extraction efficiency, such as the kinds and volume of ionic liquid, salt concentration, ultrasonic power and time, and centrifugation time were investigated and optimized. Under the optimum extraction condition, the recoveries of analytes ranged from 85.97% to 108.84% except prednisolone (62.30%). The intraday and interday precision was below 2.51% and 3.30%, respectively. 展开更多
关键词 Ionic liquid Ultrasound-Assisted EMULSIFICATION microextraction HORMONES COSMETICS High Performance liquid Chromatography
下载PDF
Determination of Trace Amounts of Lead by Modified Graphite Furnace Atomic Absorption Spectrometry after Liquid Phase Microextraction with Pyrimidine-2-thiol 被引量:1
17
作者 Saeid Nazari 《American Journal of Analytical Chemistry》 2011年第7期757-767,共11页
The liquid phase microextraction (LPME) was combined with the modified Graphite furnace atomic absorption spectrometry (GF-AAS) for determination of lead in the water and solid samples. In a preconcentration step, lea... The liquid phase microextraction (LPME) was combined with the modified Graphite furnace atomic absorption spectrometry (GF-AAS) for determination of lead in the water and solid samples. In a preconcentration step, lead was extracted from a 2 ml of its aqueous sample in the pH = 5 as lead-Pyrimidine-2-thiol cationic complex into a 4 μl drop of 1,2 dichloroethane and ammonium tetraphenylborate as counter ion immersed in the solution. In the drop, the lead-Pyrimidine-2-thiol ammonium tetraphenylborate ion associated complex was formed. After extraction, the microdrop was retracted and directly transferred into a graphite tube modified by [W.Pd.Mg] (c). Some effective parameters on extraction and complex formation, such as type and volume of organic solvent, pH, concentration of chelating agent and counter ion, extraction time, stirring rate and effect of salt were optimized. Under the optimum conditions, the enrichment factor and recovery were 525% and 94%, respectively. The calibration graph was linear in the range of 0.01 - 12 μg?L–1 with correlation coefficient of 0.9975 under the optimum conditions of the recommended procedure. The detection limit based on the 3Sb criterion was 0.0072 μg?L–1 and relative standard deviation (RSD) for ten replicate measurement of 0.1 μg?L–1 and 0.4 μg?L–1 lead was 4.5% and 3.8% respectively. The characteristic concentration was 0.0065 μg?L–1 equivalent to a characteristic mass of 26 fg. The results for determination of lead in reference materials, spiked tap water and seawater demonstrated the accuracy, recovery and applicability of the presented method. 展开更多
关键词 LEAD liquid Phase microextraction PRECONCENTRATION Graphite Furnace Atomic Absorption Spectrometry
下载PDF
Simple and Rapid Hollow Fiber Liquid Phase Microextraction Followed by High Performance Liquid Chromatography Method for Determination of Drug-protein Binding
18
作者 XI Guo-chen HU Shuang BAI Xiao-hong 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第5期764-768,共5页
A method was established using hollow fiber-liquid phase microextraction(HF-LPME) followed by high performance liquid chromatography(HPLC) to determine the concentration of the free(unbound) drug in the solution... A method was established using hollow fiber-liquid phase microextraction(HF-LPME) followed by high performance liquid chromatography(HPLC) to determine the concentration of the free(unbound) drug in the solution of the drug and protein. Measurements of drug-protein binding ratios and free drug concentrations were then analyzed with the Klotz equation to determine the equilibrium binding constant and number of binding sites for drug-protein interaction. The optimized method allows one to perform the efficient extraction and separation of free drug from protein-bound drug, protein, and other interfering substances. This approach was used to characterize the binding of the anticholinergic drugs atropine sulfate and scopolamine hydrobromide to proteins in human plasma and bovine serum albumin(BSA). The results demonstrate the utility of HF-LPME method for measuring free drug concentrations in protein-drug mixtures and determining the protein binding parameters of a pharmacologically important class of drugs. 展开更多
关键词 liquid phase microextraction Drug-protein binding ratio Binding parameter Anticholinergic drug
下载PDF
Modifying current thin-film microextraction(TFME)solutions for analyzing prohibited substances:Evaluating new coatings using liquid chromatography
19
作者 Łukasz Sobczak Dominika Kołodziej Krzysztof Gorynski 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2022年第3期470-480,共11页
For identifying and quantifying prohibited substances,solid-phase microextraction(SPME)continues to arouse interest as a sample preparation method.However,the practical implementation of this method in routine laborat... For identifying and quantifying prohibited substances,solid-phase microextraction(SPME)continues to arouse interest as a sample preparation method.However,the practical implementation of this method in routine laboratory testing is currently hindered by the limited number of coatings compatible with the ubiquitous high-performance liquid chromatography(HPLC)systems.Only octadecyl(C18)and polydimethylsiloxane/divinylbenzene ligands are currently marketed for this purpose.To address this situation,the present study evaluated 12 HPLC-compatible coatings,including several chemistries not currently used in this application.The stationary phases of SPME devices in the geometry of thin filmcoated blades were prepared by applying silica particles bonded with various functional ligands(C18,octyl,phenyl-hexyl,3-cyanopropyl,benzenesulfonic acid,and selected combinations of these),as well as unbonded silica,to a metal support.Most of these chemistries have not been previously used as microextraction coatings.The 48 most commonly misused substances were selected to assess the extraction efficacy of each coating,and eight desorption solvent compositions were used to optimize the desorption conditions.All samples were analyzed using an HPLC system coupled with triple quadrupole tandem mass spectrometry.This evaluation enables selection of the best-performing coatings for quantifying prohibited substances and investigates the relationship between extraction efficacy and the physicochemical characteristics of the analytes.Ultimately,using the most suitable coatings is essential for trace-level analysis of chemically diverse prohibited substances. 展开更多
关键词 Sample preparation Solid-phase microextraction Thin-film microextraction Prohibited substances Drugs of abuse High-performance liquid chromatography
下载PDF
Liquid Chromatographic Determination of Scopolamine in Hair with Suspended Drop Liquid Phase Microextraction Technique
20
作者 Mahboubeh Masrournia Zarrin Es’ haghi Mostafa Amini 《American Journal of Analytical Chemistry》 2011年第2期235-242,共8页
Hair analysis is used in some branches of alternative medicine as a method of investigation to assist diagnosis. It is very useful when a history of drug use is difficult or impossible to obtain. In this re-search sus... Hair analysis is used in some branches of alternative medicine as a method of investigation to assist diagnosis. It is very useful when a history of drug use is difficult or impossible to obtain. In this re-search suspended droplet liquid phase microextraction (SDLME) coupled with high-performance liquid chromatography and photodiode array detection (HPLC-DAD) was used for preconcentration and analysis of scopolamine in hair samples. Therefore scopolamine was extracted from 2.0 g hair sample incubated in methanol (5 h, 50°C) and adjusted to pH 7.4 with, Na2HPO4–H3PO4 buffer solution (donor phase, P1) into an organic phase (P2) 350 μl n-octanol and then back extracted into a micro drop of aqueous acceptor phase (P3), adjusted at pH 3, with HCL. The extraction time, T1 (from P1 to P2) was 2 min and T2 (from P2 to P3) was 30 min. Optimum instrumental conditions were included;A C18 reverse phase column with water-acetonitrile-methanol (80:10:10) as the mobile phase was used and wavelength for UV detec-tion was 205 nm. The linear range was 10 to 10000 ng●mL–1, enrichment factor, detec-tion limit and relative standard deviation were 77, 0.1 ng●mL–1 and 5.4 respectively. 展开更多
关键词 Column liquid CHROMATOGRAPHY Directly Suspended DROPLET liquid Phase microextraction (SDLME) SCOPOLAMINE HAIR Sample
下载PDF
上一页 1 2 113 下一页 到第
使用帮助 返回顶部