期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Radiographic Measurement of Femoral Lateral Bowing and Distal Femoral Condyle Resection Thickness: Variances and Effects on Total Knee Arthroplasty Planning 被引量:4
1
作者 Pei-Hui Wu Zhi-Qi Zhang +4 位作者 Ming-Hui Gu Xiao-Yi Zhao Yan Kang Wei-Ming Liao Ming Fu 《Chinese Medical Journal》 SCIE CAS CSCD 2017年第21期2557-2562,共6页
Background:Accurate evaluation of the plain radiography of lower limb is critical for preoperative planning of total knee arthroplasty (TKA). We aimed to investigate the effect of femoral lateral bowing and rotatio... Background:Accurate evaluation of the plain radiography of lower limb is critical for preoperative planning of total knee arthroplasty (TKA). We aimed to investigate the effect of femoral lateral bowing and rotation on the radiographic measurements of distal femoral condyle resection thickness (DRT) and the distal femoral resection valgus angle (FVA). Methods: We analyzed 246 three-dimensional femoral models generated from computed tomography images of 123 patients, acquiring projected contours in seven positions – 20° and 10° internal rotation; 0° rotation; 10°, 20°, 30°, and 40° external rotation – for each model. Medial and lateral condyle DRTs, femoral shaft lateral bowing angle (FBA), and distal FVA were determined for each position. Linear mixed effect model was used to determine the effect of degree of femur rotation on repeated measurements of DRT or FVA. Results: FBA significantly affected the FVA and DRT (Pearson's R = 0.767 and -0.408, respectively; P 〈 0.000). Samples were divided into three groups according to the FBA measured in neutral position: FBA 〈0°: DRT 3.75 ± 1.30 mm, FVA 4.53° ± 1.27°; FBA 〉0° but 〈3°: DRT 3.39 ± 1.31 mm, FVA 5.92° ± 1.31°; FBA 〉3°: DRT 2.22 ± 1.31 mm, FVA 7.37° ± 1.31°. From simulated 20° internal rotation to 40° external rotation in each femoral model, the average variation ranges of radiographically measured DRT, FVA, and FBA were 0.50 ± 0.28 mm, 2.93° ± 0.96°, and 10.33° ± 1.90°, respectively, with no significant differences among the FBA groups. The degree of femoral rotation significantly affected the FVA (F = 62.148, P 〈 0.000), whereas there was no effect on condyle resection thickness (F = 0.4705, P = 0.494). Conclusions: Axial femoral rotation has less effect on radiographic measurements of differences in the DRT than on those of the distal FVA. 展开更多
关键词 distal femoral resection Radiographic Measurement: Total Knee Arthroplasty Valgus Angle
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部