The integration of distributed optical fiber temperature sensor with supervisory control and data acquisition (SCADA) system is proposed and implemented. In the implementation of the integration, both the compatibil...The integration of distributed optical fiber temperature sensor with supervisory control and data acquisition (SCADA) system is proposed and implemented. In the implementation of the integration, both the compatibility with traditional system and the characteristics of distributed optical fiber temperature sensor is considered before Modbus TCP/IP protocol is chosen. The protocol is implemented with open source component Indy. The Modbus TCP/IP protocol used in the system is proved to be fast and robust.展开更多
The fiber optic distributed temperature sensor (DTS) is one of the most outstanding means to measure temperature distribution along an optical fiber. In this paper, we propose a novel calibration technique to measur...The fiber optic distributed temperature sensor (DTS) is one of the most outstanding means to measure temperature distribution along an optical fiber. In this paper, we propose a novel calibration technique to measure the temperature highly accurately over a wide range of temperatures. We also propose an improved double-ended configuration that is insusceptible to the differential loss change in the fiber and suitable for the field use. Then, we developed an interrogator that had high robustness in harsh environments.展开更多
A new radiation-hard germano-silicate glass optical fiber with a pure silica glass buffer and a boron-doped silica glass inner cladding was fabricated for temperature sensor application based on the fiber Bragg gratin...A new radiation-hard germano-silicate glass optical fiber with a pure silica glass buffer and a boron-doped silica glass inner cladding was fabricated for temperature sensor application based on the fiber Bragg grating(FBG)underg-ray irradiation environment.The temperature dependences of optical attenuation at 1550.5 nm and Bragg reflection wavelength shift from 18℃to 40℃before theγ-ray irradiation were about 4.57´10^(-4)dB/℃and 5.48 pm/℃,respectively.The radiation-induced optical attenuation at 1550.5 nm and the radiation-induced Bragg reflection wavelength shift under theγ-ray irradiation with the total dose of 22.85 kGy at 35℃were about 0.03 dB/m and 0.12 nm,respectively,with theγ-ray irradiation sensitivity of 5.25´10^(-3)pm/Gy.The temperature and theγ-ray irradiation dependence of optical attenuation at 1550.5 nm in the FBG written fiber with boron-doped silica glass inner cladding were about 6 times and 4 times lower than that in the FBG written fiber without boron-doped silica glass inner cladding under a temperature change from 18℃to 40℃and theγ-ray irradiation with the total dose of 22.85 kGy at 35℃,respectively.Furthermore,the effect of temperature increase on the Bragg reflection wavelength of the FBG written fiber with boron-doped silica inner cladding was much larger about 1000 times than that of theγ-ray irradiation.However,no influence on the reflection power of the Bragg wavelengths and the full width at half maximum(FWHM)bandwidth under temperature and theγ-ray irradiation change was found.Also,after theγ-ray irradiation with the dose of 22.85 kGy,no significant change in the refractive index was found but the residual stresses developed in the fiber were slightly relaxed or retained.展开更多
A high sensitive fiber Bragg grating (FBG) strain sensor with automatic temperature compensation is demonstrated. FBG is axially linked with a stick and their free ends are fixed to the measured object. When the mea...A high sensitive fiber Bragg grating (FBG) strain sensor with automatic temperature compensation is demonstrated. FBG is axially linked with a stick and their free ends are fixed to the measured object. When the measured strain changes, the stick does not change in length, but the FBG does. When the temperature changes, the stick changes in length to pull the FBG to realize temperature compensation. In experiments, 1.45 times strain sensitivity of bare FBG with temperature compensation of less than 0.1 nm Bragg wavelength drift over 100 ℃ shift is achieved.展开更多
基金supported by the National Natural Science Foundation of China under Grant No. 60608009Science Foundation of Zhejiang Province under Grant No. Y107091 and ScienceTechnology Department of Zhejiang Province under Grant No. 2008C21172.
文摘The integration of distributed optical fiber temperature sensor with supervisory control and data acquisition (SCADA) system is proposed and implemented. In the implementation of the integration, both the compatibility with traditional system and the characteristics of distributed optical fiber temperature sensor is considered before Modbus TCP/IP protocol is chosen. The protocol is implemented with open source component Indy. The Modbus TCP/IP protocol used in the system is proved to be fast and robust.
文摘The fiber optic distributed temperature sensor (DTS) is one of the most outstanding means to measure temperature distribution along an optical fiber. In this paper, we propose a novel calibration technique to measure the temperature highly accurately over a wide range of temperatures. We also propose an improved double-ended configuration that is insusceptible to the differential loss change in the fiber and suitable for the field use. Then, we developed an interrogator that had high robustness in harsh environments.
基金This work was partially supported by the Korea Electric Power Corporation Research Institute(Grant No.KEPRI-16-23)the Korea Industrial Complex Corporation Industrial Cluster Competitiveness Enhancement Project(Grant No.RGJ18014),South Korea.
文摘A new radiation-hard germano-silicate glass optical fiber with a pure silica glass buffer and a boron-doped silica glass inner cladding was fabricated for temperature sensor application based on the fiber Bragg grating(FBG)underg-ray irradiation environment.The temperature dependences of optical attenuation at 1550.5 nm and Bragg reflection wavelength shift from 18℃to 40℃before theγ-ray irradiation were about 4.57´10^(-4)dB/℃and 5.48 pm/℃,respectively.The radiation-induced optical attenuation at 1550.5 nm and the radiation-induced Bragg reflection wavelength shift under theγ-ray irradiation with the total dose of 22.85 kGy at 35℃were about 0.03 dB/m and 0.12 nm,respectively,with theγ-ray irradiation sensitivity of 5.25´10^(-3)pm/Gy.The temperature and theγ-ray irradiation dependence of optical attenuation at 1550.5 nm in the FBG written fiber with boron-doped silica glass inner cladding were about 6 times and 4 times lower than that in the FBG written fiber without boron-doped silica glass inner cladding under a temperature change from 18℃to 40℃and theγ-ray irradiation with the total dose of 22.85 kGy at 35℃,respectively.Furthermore,the effect of temperature increase on the Bragg reflection wavelength of the FBG written fiber with boron-doped silica inner cladding was much larger about 1000 times than that of theγ-ray irradiation.However,no influence on the reflection power of the Bragg wavelengths and the full width at half maximum(FWHM)bandwidth under temperature and theγ-ray irradiation change was found.Also,after theγ-ray irradiation with the dose of 22.85 kGy,no significant change in the refractive index was found but the residual stresses developed in the fiber were slightly relaxed or retained.
基金supported by the researchgrant from Institute of Crustal Dynamics (No. ZDJ2007-3),China Earthquake Administration,and Beijing PiOptics Co., Ltd
文摘A high sensitive fiber Bragg grating (FBG) strain sensor with automatic temperature compensation is demonstrated. FBG is axially linked with a stick and their free ends are fixed to the measured object. When the measured strain changes, the stick does not change in length, but the FBG does. When the temperature changes, the stick changes in length to pull the FBG to realize temperature compensation. In experiments, 1.45 times strain sensitivity of bare FBG with temperature compensation of less than 0.1 nm Bragg wavelength drift over 100 ℃ shift is achieved.