期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Repeater jamming suppression method for pulse Doppler fuze based on identity recognition and chaotic encryption 被引量:6
1
作者 Jian Dai Xin-hong Hao +2 位作者 Qiang Liu Xiao-peng Yan Ping Li 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2021年第3期1002-1012,共11页
Pulse Doppler(PD) fuze is widely used in current battlefield. However, with the threat of repeater jamming, especially digital radio frequency memory technology, the deficiency in the anti-repeater jamming of a tradit... Pulse Doppler(PD) fuze is widely used in current battlefield. However, with the threat of repeater jamming, especially digital radio frequency memory technology, the deficiency in the anti-repeater jamming of a traditional PD fuze increasingly emerges. Therefore, a repeater jamming suppression method for a PD fuze based on identity(ID) recognition and chaotic encryption is proposed. Every fuze has its own ID which is encrypted with different chaotic binary sequences in every pulse period of the transmitted signal. The thumbtack-shaped ambiguity function shows a good resolution and distance cutoff characteristic. The ability of anti-repeater jamming is emphatically analyzed, and the results at different signal-to-noise ratio(SNR) show a strong anti-repeater jamming ability and range resolution that the proposed method possesses. Furthermore, the anti-repeater jamming ability is influenced by processing gain, bit error rate(BER) and correlation function. The simulation result validates the theoretical analysis, it shows the proposed method can significantly improve the anti-repeater jamming ability of a PD fuze. 展开更多
关键词 pulse doppler fuze ID Chaotic binary code ENCRYPTION Repeater jamming
下载PDF
Study on the method of polarization suppression of cheating jamming in pulse Doppler radar 被引量:5
2
作者 SongLizhong QiaoXiaolin MengXiande JinMing 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2005年第2期310-315,共6页
A jamming suppression method based on polarization signal detection is proposed under common range and velocity cheating jammingfor pulse Doppler radar. On the basis of the separation of the target and the jamming, th... A jamming suppression method based on polarization signal detection is proposed under common range and velocity cheating jammingfor pulse Doppler radar. On the basis of the separation of the target and the jamming, the range and velocity track on the true target are realized. Firstly the signal processing model of the full polarization pulse Doppler radar is introduced. Secondly the method of correct target separation is discussed, which is the twice detections of energy and polarization state on the two dimension resolution cells of range and velocity of the radar echo. Finally the simulations are performed and the results prove the validity. What's more, multiple range and velocity cheating jamming can be suppressed at the same time if the target and the jamming are different in the polarization domain. 展开更多
关键词 pulse doppler radar POLARIZATION signal detection.
下载PDF
Adaptive target and jamming recognition for the pulse doppler radar fuze based on a time-frequency joint feature and an online-updated naive bayesian classifier with minimal risk 被引量:6
3
作者 Jian Dai Xin-hong Hao +2 位作者 Ze Li Ping Li Xiao-peng Yan 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2022年第3期457-466,共10页
This paper considers the problem of target and jamming recognition for the pulse Doppler radar fuze(PDRF).To solve the problem,the matched filter outputs of the PDRF under the action of target and jamming are analyzed... This paper considers the problem of target and jamming recognition for the pulse Doppler radar fuze(PDRF).To solve the problem,the matched filter outputs of the PDRF under the action of target and jamming are analyzed.Then,the frequency entropy and peak-to-peak ratio are extracted from the matched filter output of the PDRF,and the time-frequency joint feature is constructed.Based on the time-frequency joint feature,the naive Bayesian classifier(NBC)with minimal risk is established for target and jamming recognition.To improve the adaptability of the proposed method in complex environments,an online update process that adaptively modifies the classifier in the duration of the work of the PDRF is proposed.The experiments show that the PDRF can maintain high recognition accuracy when the signal-to-noise ratio(SNR)decreases and the jamming-to-signal ratio(JSR)increases.Moreover,the applicable analysis shows that he ONBCMR method has low computational complexity and can fully meet the real-time requirements of PDRF. 展开更多
关键词 pulse doppler radar fuze(PDRF) Target and jamming recognition Time-frequency joint feature Online-update naive Bayesian classifier minimal risk(ONBCMR)
下载PDF
SEVERAL PROBLEMS IN DESIGNING DBS SYSTEMS FOR AIRBORNE PULSE DOPPLER RADAR
4
作者 杨建航 《Chinese Journal of Aeronautics》 SCIE EI CSCD 1998年第2期20-28,共9页
SEVERALPROBLEMSINDESIGNINGDBSSYSTEMSFORAIRBORNEPULSEDOPPLERRADARYANGJianhang(杨建航)(DepartmentofAero-Electroni... SEVERALPROBLEMSINDESIGNINGDBSSYSTEMSFORAIRBORNEPULSEDOPPLERRADARYANGJianhang(杨建航)(DepartmentofAero-ElectronicEnginering,AirFo... 展开更多
关键词 pulse doppler radar doppler beam sharpening (DBS) batch processing period frame scan time
下载PDF
QUANTITATIVE ANALYSIS ON CHANGES OF HEPATIC HEMODYNAMICS AFTER TRANSCUTANEOUS ELECTRIC PULSE STIMULATION OF LOCAL POINTS BY USING COLOR DOPPLER ULTRASOUND DIAGNOSTIC APPARATUS
5
作者 张均倡 王岭 +2 位作者 李红 李峻 张云 《World Journal of Acupuncture-Moxibustion》 2006年第3期3-7,共5页
Objective: To evaluate the effect of transcutaneous electric pulse stimulation (TEPS) on hepatic blood flow and parenchymal microcirculation in patients with fatty liver. Methods: A total of 31 fatty liver volunteer p... Objective: To evaluate the effect of transcutaneous electric pulse stimulation (TEPS) on hepatic blood flow and parenchymal microcirculation in patients with fatty liver. Methods: A total of 31 fatty liver volunteer patients were observed in this study. Changes of color Doppler energy (CDE) images before and after TEPS of local points nearby the liver were recorded by using color Doppler ultrasound diagnostic apparatus (ACUSON 128XP/10C). Sum of color pixel area (SCPA), average of color value (ACV) and SCPA×ACV (integral) of the hepatic flow images were analyzed by an image processing system, single blind method and paired t-test. Programmed TEPS (0.5- 150 Hz / 2 000 Hz , 10- 25 V ) was applied to the right Qimen (期门 LR 14)-Jingmen (京门 GB 25), Fuai (腹哀 SP 16)-Ganshu (肝俞 BL 18) respectively for 15 min. Results: Compared with basic values of pretreatment, SCPA, ACV and SCPA×ACV increased significantly (t=2.71, P<0.02; t=3.42, P<0.01; and t=8.15, P<0.001) after TEPS, meaning improvement of hepatic blood flow supply. Conclusion: TEPS of acupoints near the liver can improve hepatic blood flow and hepatic parenchymal microcirculation in patients with fatty liver. 展开更多
关键词 Fatty liver Transcutaneous electric pulse stimulation Color doppler energy Hepatic hemodynamics
下载PDF
HPRF pulse Doppler stepped frequency radar 被引量:9
6
作者 LONG Teng REN LiXiang 《Science in China(Series F)》 2009年第5期883-893,共11页
Stepped frequency radar is a well known scheme to generate high range resolution profile (HRRP) of targets. Through appropriate radar parameter design, the radar enables both unambiguous velocity measurement and hig... Stepped frequency radar is a well known scheme to generate high range resolution profile (HRRP) of targets. Through appropriate radar parameter design, the radar enables both unambiguous velocity measurement and high resolution ranging within a single dwell in a high pulse repetition frequency (HPRF) mode. This paper analyzes in detail the design principle of the HPRF stepped frequency radar system, the solution to its ambiguity issue, as well as its signal processing method. Both theoretical analysis and simulation results demonstrate that the proposed radar scheme can work independently to solve the problem of motion compensation, and is therefore highly applicable to many new types of radar. 展开更多
关键词 DFT HPRF pulse doppler radar stepped frequency radar
原文传递
Wind Measurement with a Wind Profiling Radar
7
作者 Qi Rundong, Huang Changcheng and Tian Wenbin Beijing Institute of Radio Measurement, P. O. Box 3923, Beijing 100854, China 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 1991年第1期81-88,共8页
The first troposphere wind profiling radar in China has been in operation. The paper describes the radar parameters and characteristics with some experimental results presented.
关键词 pulsed doppler radar Wind profiler Wind measurement.
下载PDF
Computer simulation studies of pulsed Doppler signals from vortices
8
作者 CHEN Sizhong ,WANG Yuanyuan, WANG Weiqi (Electronic Engineering Department, Fudan University Shanghai 200433) 《Chinese Journal of Acoustics》 2001年第3期266-274,共9页
A computer simulation method for pulsed Doppler signals from vortices was pro- posed to generate simulated vortex Doppler signals under various given circumstances. The relative waveforms, such as the maximum frequenc... A computer simulation method for pulsed Doppler signals from vortices was pro- posed to generate simulated vortex Doppler signals under various given circumstances. The relative waveforms, such as the maximum frequency waveform, the mean frequency waveform and the bandwidth waveform, were obtained using the short time Fourier analysis of those simulated signals. The relations were studied between several spectrum parameters obtained from these waveforms and given simulation conditions, such as the position and the size of the sample volume, the distance between two vortices, the free stream velocity and the maximum tangent velocity of the vortex. The sensitive parameters were found to detect vortices using the pulsed Doppler techniques. 展开更多
关键词 Computer simulation studies of pulsed doppler signals from vortices LENGTH
原文传递
Suppression of Doppler dispersion in the target detection with multi-carrier signal 被引量:1
9
作者 Yang Chao Wang Mei +1 位作者 Zheng Lin Tang Jianming 《The Journal of China Universities of Posts and Telecommunications》 EI CSCD 2016年第2期1-5,30,共6页
The output of each individual channel in multi-carrier system can be processed to detect moving targets by the approach used in tradition narrowband pulse Doppler(PD) radar and then using non-coherent integration to... The output of each individual channel in multi-carrier system can be processed to detect moving targets by the approach used in tradition narrowband pulse Doppler(PD) radar and then using non-coherent integration to promote signal noise ratio(SNR). However, due to the difference of Doppler on sub-carriers, there occurs Doppler dispersion during non-coherent integration, which causes attenuation and extension on target's amplitude. Especially, it can deteriorate performance of target detection under wideband multicarrier system or fast-moving target scene. In this paper, a modified Fourier transform kernel is proposed to solve Doppler dispersion for multi-carrier chirp signal. It can achieve accumulation at the same frequency point for the target's Doppler of each subcarrier. The simulation results indicate that this method can effectively eliminate the integral loss caused by Doppler dispersion. 展开更多
关键词 multi-carrier chirp doppler dispersion pulse doppler(PD) doppler frequency shift(DFS)
原文传递
Changes of blood circulation of the extremity after external fixation for tibia shaft defect: an experimental study 被引量:2
10
作者 杨柳 李起鸿 周仲安 《Chinese Journal of Traumatology》 CAS 2001年第2期89-92,共4页
Objective:: To assess and compare two approaches, end to end compression with lengthening (EECL) and segmental bone transport by lengthening (STBL), for long tubular bone defect and nonunion. Methods: Ten goats were u... Objective:: To assess and compare two approaches, end to end compression with lengthening (EECL) and segmental bone transport by lengthening (STBL), for long tubular bone defect and nonunion. Methods: Ten goats were used to establish the bone defect model of the mid-tibia. The bone defect ends were shortened step by step with a sulcated half-ring external fixator. Changes of the blood flow of the distal extremity were measured with pulse-Doppler monitor and angiography. Results: The blood flow in the distal extremity was not affected when bone defect was less than 15% of the original length. Blood circulatory disorder would appear in the distal extremity when bone defect ranged 15%-20% of the original length. The necrosis would appear in the extremity because of the blood circulatory obstacle when bone defect was more than 20% of the original length.Conclusions: EECL is an appropriate alternative of treatments if bone defect is less than 15%; while SBTL may be feasible if bone defect is over 20% of the original length. When bone defect ranges between 15% and 20%, EECL should be applied with great care on condition of keeping watch on the extremity circulation with pulse-Doppler monitor. 展开更多
关键词 Blood circulation External fixators Fracture healing Ultrasonography doppler pulsed
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部