Patient dose considerations in computed tomography examinations 被引量:4
1
作者 Ioannis A Tsalafoutas Georgios V Koukourakis 《World Journal of Radiology》 CAS 2010年第7期262-268,共7页
Ionizing radiation is extensively used in medicine and its contribution to both diagnosis and therapy is undisputable.However,the use of ionizing radiation also involves a certain risk since it may cause damage to tis... Ionizing radiation is extensively used in medicine and its contribution to both diagnosis and therapy is undisputable.However,the use of ionizing radiation also involves a certain risk since it may cause damage to tissues and organs and trigger carcinogenesis.Computed tomography(CT) is currently one of the major contributors to the collective population radiation dose both because it is a relatively high dose examination and an increasing number of people are subjected to CT examinations many times during their lifetime.The evolution of CT scanner technology has greatly increased the clinical applications of CT and its availability throughout the world and made it a routine rather than a specialized examination.With the modern multislice CT scanners,fast volume scanning of the whole human body within less than 1 min is now feasible.Two dimensional images of superb quality can be reconstructed in every possible plane with respect to the patient axis(e.g.axial,sagital and coronal).Furthermore,three-dimensional images of all anatomic structures and organs can be produced with only minimal additional effort(e.g.skeleton,tracheobronchial tree,gastrointestinal system and cardiovascular system).All these applications,which are diagnostically valuable,also involve a significant radiation risk.Therefore,all medical professionals involved with CT,either as referring or examining medical doctors must be aware of the risks involved before they decide to prescribe or perform CT examinations.Ultimately,the final decision concerning justification for a prescribed CT examination lies upon the radiologist.In this paper,we summarize the basic information concerning the detrimental effects of ionizing radiation,as well as the CT dosimetry background.Furthermore,after a brief summary of the evolution of CT scanning,the current CT scanner technology and its special features with respect to patient doses are given in detail.Some numerical data is also given in order to comprehend the magnitude of the potential radiation risk involved in comparison with risk from exposure to natural background radiation levels. 展开更多
关键词 COMPUTED TOMOGRAPHY COMPUTED TOMOGRAPHY dose index dose length product Patient dose Effective dose SKIN dose Radiation risk
下载PDF
Assessment of Organ Dose and Effective Dose from Head CT Examination in a Large Hospital in South-Southern Nigeria
2
作者 R. I. Obed M. E. Ekpo 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第4期431-437,共7页
The magnitude of radiation dose imparted to patients who underwent Head Computed Tomography examination in a large tertiary hospital in South-Southern Nigeria has been estimated. CT-ExPO dosimetry software was used to... The magnitude of radiation dose imparted to patients who underwent Head Computed Tomography examination in a large tertiary hospital in South-Southern Nigeria has been estimated. CT-ExPO dosimetry software was used to determine the effective and organ doses to the head region of 40 adult patients. Scanning parameters were retrieved from the CT monitor for both contrast-enhanced and non-contrast head CT examinations. The tube potential ranged from 100 kVp to 120 kVp, while the mAs ranged from 127 mAs to 202 mAs. The mean values of the volume Computed Tomography Dose Index (CTDIvol) and Dose Length Product (DLP) for the contrast-enhanced Head CT examination were 166.4 ± 39.6 mGy and 3568.6 ± 756.1 mGy·cm, respectively, while for the non-contrast examination they were 86.6 ± 30.4 mGy and 2102.3 ± 870.3 mGy·cm, respectively. The effective doses were higher for the contrast-enhanced study than for the non-contrast study by a factor of 1.6. Results were compared with the European Union reference doses and other published data and were found to be higher. Doses to the organs which comprise of brain, red bone marrow, thyroid and eye lens were also estimated. The high variation in the doses in this study may be due to differences in imaging protocols such as large range of mAs and scan lengths and also the algorithm of the scanner. 展开更多
关键词 COMPUTED Tomography dose Index dose length product ORGAN doses Effective dose CT-ExPO Software
下载PDF
医用X射线CT主要检查类型所致成年受检者剂量研究 被引量:24
3
作者 高林峰 郑钧正 +4 位作者 卓维海 王彬 曲良勇 姚杰 钱爱君 《辐射防护》 CAS CSCD 北大核心 2013年第2期74-81,共8页
研究与掌握广泛普及的医用X射线CT(X-CT)所致受检者的剂量水平,是加强医疗照射防护的一个关键课题。在上海市"十一五"期间医疗照射水平调查研究中,根据全市拥有X-CT机各种品牌及其在各级医院实际应用比例情况,抽取全市约占30%... 研究与掌握广泛普及的医用X射线CT(X-CT)所致受检者的剂量水平,是加强医疗照射防护的一个关键课题。在上海市"十一五"期间医疗照射水平调查研究中,根据全市拥有X-CT机各种品牌及其在各级医院实际应用比例情况,抽取全市约占30%的X-CT机计45台进行现场调研。累计针对8种常见主要检查类型的500例成年受检者,调查他们进行X-CT检查时所用的扫描参数及其相关剂量学信息,借助剂量转换系数等估算其所致典型有效剂量。研究结果表明,头颅、胸部和腹部的X-CT扫描中,各自加权CT剂量指数(CTDIw)的均值分别为55.4 mGy、12.5 mGy和18.4 mGy,而相应的剂量长度乘积(DLP)的均值分别为603 mGy.cm、294 mGy.cm和415 mGy.cm。由此估算出头颅、胸部和腹部X-CT扫描所致成年受检者有效剂量的典型值分别为1.4 mSv、5.3 mSv和7.5 mSv。头颅扫描检查的CTDIw值通常高于耳道、眼部或鼻窦的诊断检查。显然,必须进一步加强X-CT扫描检查的影像质量及其所致剂量的优化匹配研究,尤其必须注意恰当选取各类X-CT检查所用的扫描参数,并不断完善相应的X-CT检查医疗照射指导(参考)水平,推动X-CT检查的医疗照射防护最优化。 展开更多
关键词 X—CT CT剂量指数 剂量长度乘积 有效剂量 诊断参考水平
下载PDF
59521例CT检查辐射剂量分析 被引量:17
4
作者 侯超 张晓东 +1 位作者 刘建新 王霄英 《放射学实践》 北大核心 2016年第12期1155-1158,共4页
目的:分析59521例CT检查的辐射剂量数据,建立医院水平的CT诊断剂量参考水平。方法:使用CT辐射剂量计算软件,回顾性分析本院2015年7月-2016年6月共59521例成人的CT检查数据。按照检查部位分别计算CT容积剂量指数(CTDIvol)、体型特异性剂... 目的:分析59521例CT检查的辐射剂量数据,建立医院水平的CT诊断剂量参考水平。方法:使用CT辐射剂量计算软件,回顾性分析本院2015年7月-2016年6月共59521例成人的CT检查数据。按照检查部位分别计算CT容积剂量指数(CTDIvol)、体型特异性剂量估计(SSDE)、剂量长度乘积(DLP)和有效剂量(ED)的中位数及四分位数间距(IQR),取CTDIvol和DLP的第3个四分位数(Q3)为诊断剂量参考水平(DRL),其中胸部CT的数据分为低剂量、单期、多期和全部扫描分别计算,腹部CT的数据分为单期、多期和全部检查分别计算。结果:各部位CTDIvol的DRL:头部为45.2mGy;胸部低剂量为1.3mGy,单期扫描为11.5mGy,多期扫描为11.4mGy,总剂量为11.8mGy;腹部单期扫描为20.6mGy,多期扫描为20.2mGy,总剂量为20.6mGy;冠状动脉为12.9mGy。各部位DLP的DRL:头部为569.8mGy·cm;胸部低剂量为42.0mGy·cm,单期扫描为399.0mGy·cm,多期扫描为968.5mGy·cm,总剂量为474.0mGy·cm;腹部单期扫描为958.0mGy·cm,多期扫描为2419.1mGy·cm,总剂量为2045.1mGy·cm;冠状动脉为328.0mGy·cm。结论:对临床日常工作中CT检查辐射剂量数据的汇总分析有助于在医院水平评估CT辐射剂量。 展开更多
关键词 体层摄影术 X线计算机 辐射剂量 剂量长度乘积 诊断参考值
下载PDF
剂量指数结合全模型迭代重建技术在降低儿童胸部CT扫描辐射剂量中的应用研究 被引量:10
5
作者 王梅 边传振 +1 位作者 张见 刘鹏 《医疗卫生装备》 CAS 2020年第7期59-63,共5页
目的:探讨各年龄段儿童胸部CT扫描时剂量指数(DoseRight index,DRI)的临界值,并对比分析全模型迭代重建(iterative model reconstruction,IMR)技术和混合迭代重建(iDose4)技术在低DRI条件下对图像质量的改善能力。方法:将行胸部CT扫描... 目的:探讨各年龄段儿童胸部CT扫描时剂量指数(DoseRight index,DRI)的临界值,并对比分析全模型迭代重建(iterative model reconstruction,IMR)技术和混合迭代重建(iDose4)技术在低DRI条件下对图像质量的改善能力。方法:将行胸部CT扫描的临床预实验组(341例)和临床实验组(137例)共478例6~16岁患儿均按年龄分为6~9岁组、10~13岁组和14~16岁组,采用飞利浦128排Brilliance iCT进行数据采集(管电压100 kV,自动曝光控制技术)。临床预实验组预设6组不同的DRI(分别为18、16、14、12、10、8)进行扫描,图像采用iDose4技术进行重建,然后对图像质量和辐射剂量进行对比分析,得到DRI临界值;采用DRI临界值扫描条件对临床实验组进行扫描,图像分别采用iDose4技术和IMR技术进行重建,并对比分析其图像质量。结果:临床预实验组中6~9岁患儿DRI的临界值是10,10~13岁患儿DRI的临界值是12,14~16岁患儿DRI的临界值是14;3组患儿的信噪比(signal-to-noise ratio,SNR)在胸大肌处及主动脉处均随着DRI的增加而增加(P<0.01);3组患儿的容积CT剂量指数(volume CT dose index,CTDIvol)及剂量长度乘积(dose length product,DLP)均随DRI的减小而降低(P<0.01)。临床实验组3组患儿的IMR图像均优于iDose4图像(P<0.05)。结论:合适的DRI结合IMR重建技术能够降低儿童胸部CT检查的辐射剂量并保证图像质量。 展开更多
关键词 胸部CT 辐射剂量 剂量指数 容积CT剂量指数 剂量长度乘积
下载PDF
64层MDCT冠状动脉成像不同心率扇区重建的应用价值 被引量:2
6
作者 缪熙音 陈刚 +4 位作者 陈文芳 陆海峰 张利军 陆秀良 曾蒙苏 《中国临床医学》 2011年第4期555-557,共3页
目的:了解扇区重建技术在冠状动脉CT成像中的应用价值。方法:58例受检者,根据心率分为3组,A组,心率〈75次/min,单扇区重建;B组,心率75~94次/min,双扇区重建;C组,心率95~115次/min,四扇区重建。分别测量冠状窦开口处增强前后CT值的变化... 目的:了解扇区重建技术在冠状动脉CT成像中的应用价值。方法:58例受检者,根据心率分为3组,A组,心率〈75次/min,单扇区重建;B组,心率75~94次/min,双扇区重建;C组,心率95~115次/min,四扇区重建。分别测量冠状窦开口处增强前后CT值的变化,并计算强化率,同时测量受检者的受辐射剂量CTD和DLP值。对三维冠状动脉重建图像质量按5个等级进行主观评分:5分无伪影;4分轻微伪影,仅主干的某一段轻微模糊,诊断不受影响;3分为中等伪影,某一支冠状动脉主干的1/2以上模糊,但可以诊断;2分为严重伪影,某一支冠状动脉主干全长均模糊不清或不连续,诊断受限;1分为冠状动脉主干不能识别,不能作出诊断。其中4分以上因伪影的干扰较少定为优良。结果:①主观评分:A组:共29例,优良率为100%;B组:共20例,优良率为85%;C组:共9例,优良率为56%;②客观评估:3组病例的强化均值、强化率、CTD和DLP值之间均存在显著差异(P〈0.05),单扇区扫描获得的图像的强化效果最佳,且受检者在检查过程中的所受到的辐射剂量最小。结论:受检者在检查前服用β受体阻滞剂控制心率,并采用单扇区重建技术能获得理想的冠状动脉诊断图像。 展开更多
关键词 体层摄影术 X线计算机 多扇区重建 CT剂量指数 剂量长度乘积
下载PDF
CT检查中辐射剂量的研究 被引量:12
7
作者 杨燕敏 曹厚德 《医学影像学杂志》 2006年第8期865-867,共3页
目的:探讨CT检查中CT扫描基本参数对辐射剂量的影响。方法:随机抽取2006年1-5月与2005年同期、同部位各30例腹部常规CT、CT血管造影(CTA)两种检查的基本参数值(mAs、层数、层厚)及辐射剂量值进行回顾性比较。结果;2006年与2005... 目的:探讨CT检查中CT扫描基本参数对辐射剂量的影响。方法:随机抽取2006年1-5月与2005年同期、同部位各30例腹部常规CT、CT血管造影(CTA)两种检查的基本参数值(mAs、层数、层厚)及辐射剂量值进行回顾性比较。结果;2006年与2005年同期腹部CT检查人次相比,在常规扫描、CTA、三维成像方面分别增加了16.12%、84.15%、300%人次(P〈0.05)。腹部CTA较常规扫描层数增加135.35%(P〈0.01)、层厚减少16.12%(P〈0.02)、mAs增加10.46%(P〈0.01)、DLP增加33.28%(P〈0.01)。结论:CT检查2006年罗2005年同期人次增加且随着mAs增加或层数增加、层厚减薄,受检者所受辐射剂量增加。 展开更多
关键词 辐射剂量 体层摄影术 X线计算机 血管造影术 容积CT加权剂量指数 剂量长度积 质量因子
下载PDF
泪道CT造影中联合三维重建的价值和辐射剂量研究 被引量:1
8
作者 李莹 胡健 贾亮 《解放军医学院学报》 CAS 2020年第7期662-665,共4页
目的评估及对比泪道CT造影检查中接受平扫与平扫联合三维重建患者所暴露的辐射剂量和获得的有效图像信息数量,探讨三维重建技术在泪道CT造影中的价值和必要性。方法回顾性分析96例因泪道阻塞需行泪道CT造影的患者,其中49例患者进行泪道C... 目的评估及对比泪道CT造影检查中接受平扫与平扫联合三维重建患者所暴露的辐射剂量和获得的有效图像信息数量,探讨三维重建技术在泪道CT造影中的价值和必要性。方法回顾性分析96例因泪道阻塞需行泪道CT造影的患者,其中49例患者进行泪道CT平扫检查(平扫组),47例患者进行泪道CT平扫+三维重建检查(重建组)。对比观察两组患者在检查过程中暴露的射线剂量,获得的总CT图片的数量,统计有泪道相关参考价值的有效CT图片数量,并进行对比分析。结果重建组较平扫组暴露更多辐射剂量[(504.7±405.8)mGy×cm vs(363.8±159.9)mGy×cm,P=0.026],得到更多的总CT数(289±74 vs 230±57,P=0.000)和有效CT数(132±36 vs 112±29,P=0.003),但重建组CT有效率降低(45.67%±0.51%vs48.70%±0.71%,P=0.000)。结论平扫联合三维重建较平扫检查需暴露更多的辐射剂量,虽得到较多有效泪道CT图像,但有效率下降;两种检查方法均应该考虑减少与泪道显影无关的射线暴露。 展开更多
关键词 泪道CT造影 三维重建 容积CT剂量指数 剂量长度乘积 辐射剂量 放射防护
下载PDF
飞利浦iCT256轴扫剂量特性和剂量安全管理建议
9
作者 刘小丽 郑海亮 +3 位作者 李兴东 冯树理 王仁贵 段永利 《北京生物医学工程》 2014年第3期285-291,299,共8页
目的验证iCT 256执行头部轴扫时辐射剂量机显值准确性,并探讨在该条件下辐射剂量安全管理方案。方法利用瑞典RTI公司的Solidose 400型辐射剂量计和中国计量科学研究院研制的T6M164型剂量体模(符合IEC 61223-2-6),按头部轴扫条件重复... 目的验证iCT 256执行头部轴扫时辐射剂量机显值准确性,并探讨在该条件下辐射剂量安全管理方案。方法利用瑞典RTI公司的Solidose 400型辐射剂量计和中国计量科学研究院研制的T6M164型剂量体模(符合IEC 61223-2-6),按头部轴扫条件重复三次测定剂量体模上5个钟点位的剂量值。结果①中心点CTDI<sub>100</sub>测量相对偏差在2%以内,而四周点位CTDI<sub>100</sub>测量相对偏差在20%以内;②CTDI<sub>vol</sub>实测值比机显值高5%<sup>1</sup>6%;③单次头部轴扫有效剂量在0.86<sup>3</sup>.63 mGy之间。结论中心点CTDI<sub>100</sub>的测量重复性好,外围四点位测量重复性差,且存在实测值略高于机显值的情况。应加强对患者累计辐射剂量的监管。 展开更多
关键词 轴扫 辐射剂量 吸收剂量 剂量长度乘积 多排CT 患者剂量卡
下载PDF
CT引导下肺部穿刺的辐射剂量控制 被引量:1
10
作者 王德红 姚国荣 陆中杰 《中国介入影像与治疗学》 CSCD 2013年第6期373-375,共3页
目的探讨减少CT引导下肺穿刺时辐射剂量的方法。方法将80例接受CT引导下肺部穿刺活检的患者平均分为A、B、C、D组。对A组使用64排CT、B组使用24排CT引导下穿刺,C组使用24排CT并用特殊激光定位配合真空垫固定,D组使用24排CT并用特殊激光... 目的探讨减少CT引导下肺穿刺时辐射剂量的方法。方法将80例接受CT引导下肺部穿刺活检的患者平均分为A、B、C、D组。对A组使用64排CT、B组使用24排CT引导下穿刺,C组使用24排CT并用特殊激光定位配合真空垫固定,D组使用24排CT并用特殊激光定位配合真空垫固定,同时采用低kV值和CARE DOSE 4D技术,比较各组的剂量长度乘积(DLP)。结果 A~D组DLP均值分别为(778.73±310.79)mGy.cm、(817.80±349.37)mGy.cm、(541.45±173.03)mGy.cm、(263.40±68.68)mGy.cm。A组与B组间DLP差异无统计学意义(P>0.05),B组与C组、C组与D组间DLP差异均有统计学意义(P均<0.05)。结论 CT引导下肺部穿刺术中,精确定位和低kV配合CARE Dose 4D技术能有效降低患者的辐射剂量。 展开更多
关键词 穿刺术 辐射剂量 剂量长度乘积
下载PDF
3种锥形束CT辐射剂量测量方法的比较分析 被引量:3
11
作者 崔兰柱 付娟 孟慧鹏 《医疗卫生装备》 CAS 2020年第8期45-48,58,共5页
目的:比较锥形束CT剂量指数(cone-beam CT dose index,CBDI)法、国际原子能机构(International Atomic Energy Agency,IAEA)5号报告建议的方法(以下简称“IAEA”)和美国医学物理学会(American Association of Physicists in Medicine,AA... 目的:比较锥形束CT剂量指数(cone-beam CT dose index,CBDI)法、国际原子能机构(International Atomic Energy Agency,IAEA)5号报告建议的方法(以下简称“IAEA”)和美国医学物理学会(American Association of Physicists in Medicine,AAPM)111工作组建议的方法(TG111)3种锥形束CT辐射剂量测量方法的结果并分析差异,为锥形束CT质量控制中辐射剂量测量方法的选择提供依据。方法:按照CBDI、IAEA、TG1113种CBCT辐射剂量测量方法,使用圆柱形有机玻璃(poly methyl methacrylate,PMMA)模体、0.6cc指形电离室或100 mm笔形电离室,测量Varian CBCT系统各种扫描协议(标准剂量头、低剂量头、高质量头、低剂量胸、盆腔)下的辐射剂量,并计算加权辐射剂量和归一化辐射剂量,最终分析比较各扫描协议不同方法的辐射剂量差异。结果:加权辐射剂量在所有的扫描协议中均表现为TG111方法的值最高、CBDI方法次之、IAEA方法最低;归一化辐射剂量的结果在各协议中差异均较小,最大差异在低剂量头协议中(TG111和IAEA的差异为1.45 mGy),最小差异在低剂量胸协议中(CBDI和IAEA的差异为0.06 mGy)。结论:TG111方法是用于Varian CBCT系统辐射剂量测量的首选方法,不推荐IAEA的方法用于该类设备的测量。 展开更多
关键词 锥形束CT 辐射剂量 CTDI模体 剂量长度乘积 扫描协议
下载PDF
个体因素对胸部CT辐射剂量的影响研究 被引量:3
12
作者 梁旭晴 姜阳 +2 位作者 陈玉洪 佘济 张德川 《中国CT和MRI杂志》 2022年第9期106-108,共3页
目的 探讨被检者个体因素对胸部CT辐射剂量的影响。方法 按照临床胸部扫描方案为基准,前贍性收集103例成人被检者资料,包括性别、年龄、身高、体重,记录每位被检者的剂量长度乘积(DLP),将所得数据进行多元回归分析。结果 图像质量对胸... 目的 探讨被检者个体因素对胸部CT辐射剂量的影响。方法 按照临床胸部扫描方案为基准,前贍性收集103例成人被检者资料,包括性别、年龄、身高、体重,记录每位被检者的剂量长度乘积(DLP),将所得数据进行多元回归分析。结果 图像质量对胸部CT辐射剂量无显著影响(P=0.407>0.05),对胸部CT辐射剂量有显著影响的个体因素是体重(P=5.52E-21<0.05)和年龄(P=8.08E-8<0.05),体重每增加1kg,DLP会增加5.543;年龄每递增1岁,DLP会增加2.191。结论 影响胸部CT辐射剂量的个体因素主要为:年龄、体重,他们与辐射剂量存在一定的线性关系,利用这一特定关系,为指导降低被检者的辐射剂量具有重要临床意义。 展开更多
关键词 个体因素 胸部CT扫描 剂量长度乘积(DLP) 多元回归分析
下载PDF
低剂量螺旋CT扫描技术在早期肺癌筛查中临床价值分析 被引量:4
13
作者 成启华 李婷婷 +1 位作者 王艳微 孙振文 《中外医疗》 2021年第12期8-10,14,共4页
目的探究低剂量螺旋CT扫描技术在早期肺癌筛查中临床应用。方法方便选取该院2018年4月-2020年4月60例早期肺癌患者为研究对象,均行常规扫描与低剂量螺旋CT诊断,并分析肺癌临床分期与病理分型,对比剂量长度乘积、容积CT剂量指数、图像质... 目的探究低剂量螺旋CT扫描技术在早期肺癌筛查中临床应用。方法方便选取该院2018年4月-2020年4月60例早期肺癌患者为研究对象,均行常规扫描与低剂量螺旋CT诊断,并分析肺癌临床分期与病理分型,对比剂量长度乘积、容积CT剂量指数、图像质量。结果 60例肺癌病理检查,42例I期,占比70.00%;12例Ⅲ期,占比20.00%;6例Ⅳ期,占比10.00%;低剂量螺旋CT扫描技术的剂量长度乘积为(56.83±14.62)mGy·cm、容积CT剂量指数为(1.87±0.69)mGy,与常规扫描组剂量长度乘积(389.94±31.76)mGy·cm、容积CT剂量指数(12.56±2.72)mGy比较,差异有统计学意义(t=73.798、29.508,P<0.05);低剂量螺旋CT扫描技术的图像质量评分为(3.72±0.84)分,常规CT扫描技术图像质量评分为(3.69±0.78)分,差异无统计学意义(t=0.203,P>0.05)。结论早期肺癌可使用胸部低剂量螺旋CT诊断,不会影响图像质量,可有效减少辐射剂量,且可提高检出率,诊断效果显著,可广泛应用于临床。 展开更多
关键词 低剂量螺旋CT扫描技术 早期肺癌 常规胸部螺旋CT 剂量长度乘积 图像质量 容积CT剂量指数
下载PDF
Diagnostic Reference Levels of Adults CT-Scan Imaging in Cameroon: A Pilot Study of Four Commonest CT-Protocols in Five Radiology Departments 被引量:1
14
作者 Boniface Moifo Jean Roger Moulion Tapouh +3 位作者 Mathurin Neossi Guena Thierry Ndzana Ndah Richard Ndi Samba Augustin Simo 《Open Journal of Medical Imaging》 2017年第1期1-8,共8页
CT-scan is the most irradiating tool in diagnostic radiology. For 5% - 10% of diagnostic X-ray procedures, it is responsible for 34% of irradiation according to UNSCEAR. Patients radiation protection must therefore be... CT-scan is the most irradiating tool in diagnostic radiology. For 5% - 10% of diagnostic X-ray procedures, it is responsible for 34% of irradiation according to UNSCEAR. Patients radiation protection must therefore be increased during CT-scan procedures. This requires the rigorous application of optimization principle which imposes to have “diagnostic reference levels”. Objective: The aim of this study was to determine the diagnostic reference levels (DRLs) of the four most frequent CT-scans examinations of adults in Cameroon. Material and Method: It was a cross-sectional pilot study carried out from April to September 2015 in five health facilities using CT-scan in Cameroon. The studied variables were: patients age and sex, type of CT-scan examination (cerebral, chest, abdomino-pelvic, lumbar spine), Used of IV contrast (IV﹣/ IV+), acquisition length, time of tube rotation, voltage (kV), mAs, pitch, thickness of slices, CTDIvol and DLP. For each type of examination, at least 30 patients were included per center, consecutively on the randomly predetermined days. The DRL for each type of examination was defined as the 75th percentile of its PDL and CTDIvol. Results: Of the 696 examinations, 41.2% were cerebral, 26.9% abdomino-pelvic, 17.7% lumbar spine and 14.2% chest. The mean age of patients was 52 ± 15 years [20 - 90 years], 58.9% were 50 years and older. The sex-ratio was 1.26 (55.9% males). The CT machines were 4, 8 and 16 multidetectors. The 75th percentile of DLP or DRLs [standard deviation] was: [1150 ± 278 mGy·cm], [770 ± 477 mGy·cm], [720 ± 170 mGy·cm] and [715 ± 187 mGy·cm] respectively for cerebral, lumbar spine, abdominopelvic and chest CT-scans. Taking in consideration the number of detectors, the 75th percentile of the Dose-Length product decreased with the increase number of detectors for cerebral examinations but was the highest with 16 MDCT for the abdominopelvic, lumbar spine and chest CT-scans. For the chest and lumbar spine examinations, there was a significant increase in patient-dose with the increase in the number of detectors. Conclusion: Our DRLs values lie between the norms of some European countries and those of some African countries. There is remarquable variation in dose for the commonest CT-scans examinations in Cameroon, requiring then an optimization process from these determined DRLs and establishment of national DRLs. Special attention to optimization should be paid when using 16 MDCT. 展开更多
关键词 Optimization DIAGNOSTIC REFERENCE LEVELS dose length product CT dose Index Patient dose Radiation Protection Best Practices
下载PDF
低剂量扫描对先天性耳聋诊断的临床应用
15
作者 赵宇 《中外医疗》 2014年第35期29-30,共2页
目的探究低剂量扫描对先天性耳聋诊断的临床应用价值,以为临床诊断提供科学依据。方法选取该院2011年5月—2014年8月收治的40(76耳)例先天性耳聋患者为研究对象,按照收治时间分为对照组与研究组各20(38耳)例,对照组采用原机标准条件(130... 目的探究低剂量扫描对先天性耳聋诊断的临床应用价值,以为临床诊断提供科学依据。方法选取该院2011年5月—2014年8月收治的40(76耳)例先天性耳聋患者为研究对象,按照收治时间分为对照组与研究组各20(38耳)例,对照组采用原机标准条件(130 k V,100 m A)进行诊断扫描,研究组采取低剂量(130 k V,50 m A)进行诊断扫描,比对两组患者临床诊断效果。结果研究组采用低剂量扫描诊断,临床诊断准确率86.8%,与对照组92.1%相比较,差异无统计学意义(P>0.05);三维重建方面,二者清晰度之间差异无统计学意义(P>0.05);研究组患者头部CTDI(32±0.8)m Gy、(850±10)m Gy·cm,与对照组(58±1.0)m Gy、(1050±15)m Gy·cm相比较,差异有统计学意义(P<0.05)。结论低剂量扫描与标准计量扫描诊断结果差异有统计学意义,患者自身受到的辐射剂量明显偏低,有利于保护患者身体健康,具有较高的临床应用价值,值得在今后临床诊断工作中推广使用。 展开更多
关键词 低剂量扫描 先天性耳聋 剂量指数 计量长度乘积 辐射剂量
下载PDF
6种CT引导下介入诊疗程序中患者的有效辐射剂量调查 被引量:2
16
作者 张凤 《内蒙古医学杂志》 2016年第11期1281-1285,共5页
目的探讨CT引导下各种操作过程中患者的有效辐射剂量。方法回顾性分析CT引导下介入诊断和治疗259例次患者的检查资料。其中包括活检、引流、射频消融、经皮瘤内无水酒精注射术、放射性125I粒子植入术、腹腔神经丛阻滞术6种操作方法。浏... 目的探讨CT引导下各种操作过程中患者的有效辐射剂量。方法回顾性分析CT引导下介入诊断和治疗259例次患者的检查资料。其中包括活检、引流、射频消融、经皮瘤内无水酒精注射术、放射性125I粒子植入术、腹腔神经丛阻滞术6种操作方法。浏览PCAS系统上的医学信息和图像,并记录患者操作方式、扫描时间、扫描次数、总毫安秒、剂量长度乘积、有效辐射剂量根据国际放射防护委员会(ICRP)制定的蒙特卡罗有效剂量转换公式进行计算。结果不同操作方法之间与扫描时间、扫描次数、总毫安秒、剂量长度乘积,有效辐射剂量的差异均具有统计学意义。有效辐射剂量与扫描时间、扫描次数、总毫安秒、剂量长度乘积均存在正相关,且相关性具有统计学意义。结论 CT引导下介入操作因手术操作复杂程度不同,有效辐射剂量差异较大,但总体上有效辐射剂量相对较小。 展开更多
关键词 CT引导下介入 有效辐射剂量 剂量长度乘积
下载PDF
The Analysis of Effective Radiation Dose during PET/CT Examination 被引量:1
17
作者 ZHANG Hong-yu LI Ying-xin 《Chinese Journal of Biomedical Engineering(English Edition)》 CSCD 2016年第3期134-138,共5页
Objective: In order to reduce the effective dose level of the patients to explore the best scanning conditions, various factors affecting the level of PET/CT examination were analyzed. Methods: The effective doses of ... Objective: In order to reduce the effective dose level of the patients to explore the best scanning conditions, various factors affecting the level of PET/CT examination were analyzed. Methods: The effective doses of CT and pet were calculated respectively during PET/CT examination, Scanning parameters of CT and PET were optimized to reduce the effective dose of patients to a minimum while maintaining the image quality. Results: The tube voltage and tube current of CT, the injection dose during PET examination can affect the effective dose of the patients significantly. Conclusion: According to different types of patients and diseases to develop personalized scanning program, the effective dose level of the patients can be significantly reduced. 展开更多
关键词 positron emission tomography/computer tomography(PET/CT) the effective dose volume CT dose index dose length product
原文传递
我国CT扫描检查中受检者剂量调查结果与分析 被引量:22
18
作者 徐辉 岳保荣 +2 位作者 尉可道 王建超 范瑶华 《中华放射医学与防护杂志》 CAS CSCD 北大核心 2019年第3期213-217,共5页
目的通过调查全国15个省市不同级别医疗机构的CT扫描参数并计算受检者剂量,分析我国CT检查中受检者剂量水平,为建立适合我国国民体质特征的CT诊断参考水平提供依据。方法按照《医用辐射危害评价与控制技术研究》实施方案要求,调查临床实... 目的通过调查全国15个省市不同级别医疗机构的CT扫描参数并计算受检者剂量,分析我国CT检查中受检者剂量水平,为建立适合我国国民体质特征的CT诊断参考水平提供依据。方法按照《医用辐射危害评价与控制技术研究》实施方案要求,调查临床实际CT扫描中受检者信息和CT扫描参数,根据临床受检者实际扫描参数,使用CT电离室测量CT设备的CT剂量指数(包括CTDI100、CTDIW和CTDIVOL),计算代表受检者剂量的剂量长度乘积(DLP)。结果共在全国15个省市的166家医院调查的483台次不同类型CT扫描设备上,调查了6524例CT扫描程序。对于头颅、胸部、腹部和腰椎等不同的CT扫描部位,其加权CT剂量指数(CTDIW)平均值分别为43、15、19和25mGy,第75百分位数分别为50、19、23和32mGy;相应DLP的平均值分别为540、397、503和376mGy·cm,第75百分位数分别为659、525、632和479mGy·cm。结论通过此次调查基本上掌握了我国部分省市CT扫描检查中受检者剂量,本次4种部位受检者剂量的第75百分位数,与其他国家和地区的出版物中给出的诊断参考水平互有高低,提示应根据我国国民体质特征,建立适合本国或者不同地区的CT检查中受检者诊断参考水平的重要性,推动CT检查的医疗照射防护最优化。 展开更多
关键词 CT CT剂量指数 剂量长度乘积 诊断参考水平
原文传递
河北省CT检查成年受检者剂量水平调查 被引量:8
19
作者 郭大伟 罗英男 +3 位作者 高艳辉 张京战 杨彦文 周开建 《职业与健康》 CAS 2021年第7期865-868,共4页
目的通过对18家医院433例CT受检者的剂量报告统计分析,初步了解河北省CT受检者辐射剂量水平。方法选择不同区域、不同级别的医院作为调查的采样医院,通过医院CT医学影像系统随机选择2017年接受CT放射诊断的成年受检者,针对样本受检者剂... 目的通过对18家医院433例CT受检者的剂量报告统计分析,初步了解河北省CT受检者辐射剂量水平。方法选择不同区域、不同级别的医院作为调查的采样医院,通过医院CT医学影像系统随机选择2017年接受CT放射诊断的成年受检者,针对样本受检者剂量报告中显示数据进行计算建立数据库,用SPSS 18.0软件对数据进行分析。结果本次调查结果各部位容积CT剂量指数(CTDIvol)及剂量长度乘积(DLP)的中位值均满足WS/T 637—2018《X射线计算机断层摄影成年人诊断参考水平》指导水平的要求,与其他省市调查结果相比,腰、胸、腹、四肢CTDIvol、加权CT剂量指数(CTDIw)或DLP的75%分位值差异较大,多处差异超出20%。结论 CT检查实践活动应在指导水平(DRL)的约束下进行,各省应当在国家级DRL的基础上通过剂量调查制定各自的省级DRL,给出更详细的剂量指导水平规范辖区内的CT检查实践。 展开更多
关键词 CT 辐射剂量 CT剂量指数 剂量长度乘积 扫描参数
原文传递
广东省MDCT机所致受检者剂量水平初探 被引量:8
20
作者 谭展 邹剑明 +2 位作者 黄伟旭 龙旋 马睿 《中国辐射卫生》 2018年第5期465-467,471,共4页
目的了解广东省MDCT机所致受检者辐射剂量水平。方法采用分层随机抽样方法,选取广东省24台MDCT机进行医疗照射剂量水平调查,分析广东省MDCT检查所致受检者的辐射剂量水平。结果成人头部、成人胸部、成人腹部、成人脊柱、成人四肢、成人... 目的了解广东省MDCT机所致受检者辐射剂量水平。方法采用分层随机抽样方法,选取广东省24台MDCT机进行医疗照射剂量水平调查,分析广东省MDCT检查所致受检者的辐射剂量水平。结果成人头部、成人胸部、成人腹部、成人脊柱、成人四肢、成人冠脉的加权CT剂量指数的均值分别为44. 5、15. 4、20. 0、23. 4、16. 9、38. 2 m Gy,而相应的剂量长度乘积的均值分别为776、482、693、691、539、1056 m Gy·cm;儿童头部、儿童胸部、儿童腹部的加权CT剂量指数的均值分别为20. 9、9. 6、15. 1 m Gy,而相应的剂量长度乘积的均值分别为257、167、472 m Gy·cm。结论调查数据可以促进对受检者的剂量控制,以更好推动辐射防护最优化。 展开更多
关键词 CT 加权CT剂量指数 剂量长度乘积 剂量水平
原文传递