期刊文献+
共找到18,346篇文章
< 1 2 250 >
每页显示 20 50 100
A Study to Compare the Safety and Efficacy of Solifenacin, Tamsulosin and Tadalafil in Relieving Double-J Stent Related Symptoms
1
作者 Appiya Ramamoorthy Balaji Pritam Pritish Patnaik +4 位作者 Javangula Venkata Surya Prakash Sattanathan Vetrichandar Krishnan Vembu Arasi Arun Kumar Paranjothi Vetrivel Natarajan 《Open Journal of Urology》 2020年第3期42-51,共10页
Objective: To evaluate and compare the safety and efficacy of Solifenacin, Tamsulosin, and Tadalafil in treating ureteral stent related symptoms (SRS) in patients with indwelling Double-J ureteral stents. Materials an... Objective: To evaluate and compare the safety and efficacy of Solifenacin, Tamsulosin, and Tadalafil in treating ureteral stent related symptoms (SRS) in patients with indwelling Double-J ureteral stents. Materials and Methods: A prospective randomized controlled study was conducted on 146 consecutive patients in the department of urology, Government Stanley Medical College & Hospital, Chennai, Tamilnadu, India between Sept 2017-March 2019, with SRS after taking informed consent and confirming DJ Stent position by X-ray KUB post-operatively. Patients were randomized into 4 groups: Group A (Placebo), Group B (Solifenacin 5 mg), and Group B (Tamsulosin 0.4 mg) and group D (Tadalafil 5 mg) at end of 1st week till the removal of DJ stent at end of 3 weeks. All patients were assessed for bothersome lower urinary tract symptoms (LUTS) using the validated Ureteral Stent Symptom Questionnaire (USSQ) at 1st week and 3 weeks after the starting of medications. Appropriate statistical analysis as carried out and the level of significance was set at P Results: LUTS, general health, and work performance improved with Solifenacin, Tamsulosin and Tadalafil and all the three were comparable in relieving urinary symptoms. Tadalafil was better at relieving body pain, additional problems and sexual problems better than Tamsulosin. Tadalafil showed comparable improvement in LUTS, better sexual health and decreased body pain compared to solifenacin, whereas the latter had better general health, additional problems & work performance scores. Conclusion: Solifenacin is more effective than Tamsulosin in alleviating LUTS associated with SRS and both show a distinctive advantage over placebo. PDE inhibitor Tadalafil can also be tried for SRS and is as effective as antimuscarinics and α-blockers in relieving urinary symptoms and is more efficacious in relieving sexual symptoms and body pain. 展开更多
关键词 DOUBLE J stent Lower Urinary Tract SYMPTOMS (LUTS) stent Related SYMPTOMS (SRS) SOLIFENACIN Tadalafil TAMSULOSIN Ureteral stent Symptom Questionnaire (USSQ)
下载PDF
Two-Stent Strategy for Bifurcation Lesions in Percutaneous Transluminal Coronary Angioplasty: Real-World Evidence
2
作者 Dilip Kumar Amit Malviya +8 位作者 Animesh Mishra Rabin Chakraborty Sanjeev S. Mukherjee Soumya Patra Arindam Pande Rana Rathor Roy Debopriyo Mondal Ashesh Halder Sumit Shanker 《World Journal of Cardiovascular Diseases》 CAS 2024年第3期140-156,共17页
Background: Bifurcation lesions pose a high risk for adverse events after percutaneous coronary intervention (PCI). Evidence supporting the benefits of the two-stent strategy (2SS) for treating coronary bifurcation le... Background: Bifurcation lesions pose a high risk for adverse events after percutaneous coronary intervention (PCI). Evidence supporting the benefits of the two-stent strategy (2SS) for treating coronary bifurcation lesions in India is limited. This study aimed to evaluate the clinical outcomes of various 2SSs for percutaneous transluminal coronary angioplasty for bifurcation lesions in India. Materials and Methods: This retrospective, observational, multicentric, real-world study included 64 patients over 8 years. Data on demographics, medical history, PCI procedures, and outcomes were recorded. Descriptive statistics were computed using the SPSS software. Results: Patients (n = 64) had an average age of 65.3 ± 11.1 years, with 78.1% males. Acute coronary syndrome was reported in 18.8%, chronic stable angina in 40.6%, and unstable angina in 34.4% of participants. Two-vessel disease was observed in 98.4% of patients, and 99.4% had true bifurcation lesions. The commonly involved vessels were the left anterior descending artery (50%), left circumflex coronary artery (34.4%), and first diagonal artery (43.8%). Mean percent diameter stenosis was 87.2% ± 10.1%. The mean number of stents used was 2.00 ± 0.34. The 2SS techniques included the T and small protrusion (TAP) (39.1%), double kissing (DK) crush (18.8%), and the culotte techniques (14.1%). Procedural and angiographic success rate was 92.18%. Major adverse cardiovascular events at 1-year follow-up occurred in 7.8% of cases. Conclusion: The 2SS for bifurcation lesions showed favorable in-hospital and follow-up outcomes. Findings can serve as a resource for bifurcation angioplasty in India. Larger real-world studies with robust methodology are needed to validate these results. 展开更多
关键词 Bifurcation stenting Coronary Bifurcation Lesions PERCUTANEOUS
下载PDF
Can we predict the incidence of high-grade Clavien-Dindo complications in patients with forgotten encrusted stents undergoing endourologic management?
3
作者 Praanjal Gupta Ramanitharan Manikandan +3 位作者 Lalgudi Narayanan Dorairajan Kodakattil Sreenivasan Sreerag Sidhartha Kalra Swapnil Singh Kushwaha 《Asian Journal of Urology》 CSCD 2024年第1期99-104,共6页
Objective:Ureteral stents are customarily inserted to facilitate urinary drainage,but they come with their own glitches of being forgotten and/or encrusted leading to serious consequences.The present study aimed to re... Objective:Ureteral stents are customarily inserted to facilitate urinary drainage,but they come with their own glitches of being forgotten and/or encrusted leading to serious consequences.The present study aimed to report the complications in patients with forgotten and encrusted stents according to the Clavien-Dindo system specific to urological procedures and identify the factors leading to high-grade(Clavien-Dindo Grade 4A or above)complications.Methods:The hospital records of patients with forgotten encrusted double-J stents over a period of 8 years were reviewed.The parameters recorded included patient demographics,indwelling time,need for percutaneous nephrostomy,hemodialysis,urine culture,blood culture,total blood counts,serum creatinine,radiologic findings,management techniques,number of surgical interventions,modified Clavien-Dindo complications,follow-up,and mortality,if any.Results:Forty patients were included in the study.The median age was 52(range 6-85)years.Of the total,25(62.5%)patients had a“significant”stent load;31(77.5%)had renal failure or acute kidney injury on presentation;19(47.5%)patients had sepsis at presentation.Among the patients presented with sepsis,11(57.9%)patients demonstrated a positive urine culture;and 7/11(63.6%)patients exhibited pan-resistant organisms.Twelve out of 40(30.0%)patients in our series developed high-grade Clavien-Dindo complications.On univariate analysis,sepsis at presentation(p=0.007),stent load(p=0.031),diabetes(p=0.023),positive urine culture(p=0.007),and stent indwelling time of more than 1 year(p=0.031)were found to be significant.On multivariate logistic regression analysis,sepsis at presentation(p=0.017)and positive urine culture(p=0.016)were significant predictors for high-grade complications.Conclusion:It is prudent to identify specific risk factors,namely sepsis at presentation and positive urine culture to triage and optimize these patients before surgical management. 展开更多
关键词 Forgotten Encrusted stent Outcome PREDICTOR Clavien-Dindo complication
下载PDF
Revolutionizing palliative care:Electrocautery-enhanced lumenapposing metal stents in endoscopic-ultrasound-guided biliary drainage for malignant obstructions
4
作者 Nirmal Kumar Reddy Onteddu Naga Sai Rasagna Mareddy +2 位作者 Sai Swarupa R Vulasala Jayabharath Onteddu Mayur Virarkar 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第7期2358-2361,共4页
Patients with malignant biliary obstruction,following endoscopic retrograde cholangiopancreatography(ERCP)failure could be referred for endoscopicultrasound-guided biliary drainage through electrocautery-enhanced(ECE)... Patients with malignant biliary obstruction,following endoscopic retrograde cholangiopancreatography(ERCP)failure could be referred for endoscopicultrasound-guided biliary drainage through electrocautery-enhanced(ECE)lumen-apposing metal stent(LAMS)placement.However,the efficacy and safety of ECE-LAMS in this scenario have remained debatable due to minimal scientific evidence.The current confirmed 91.0%clinical success,96.7%technical success,7.3%reintervention rate,and 17.5%adverse events,following the treatment of malignant biliary obstruction with ECE-LAMS delivery.Finally,ECE-LAMS proved to be a generalizable strategy for managing biliary obstruction for patients who were excluded from ERCP. 展开更多
关键词 Endoscopic retrograde cholangiopancreatography Electrocautery-enhancedlumen-apposing metal stent Biliary drainage Biliary stent Endoscopic ultrasound
下载PDF
Baerveldt glaucoma implant with Supramid© ripcord stent in neovascular glaucoma: a case series
5
作者 Yuen Keat Gan Shiivaa Manjare Birapadian +1 位作者 Muhammad Irfan Abdul Jalal Norshamsiah Md Din 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期265-271,共7页
AIM:To report the outcome of Baerveldt glaucoma implant(BGI)with Supramid©ripcord use in neovascular glaucoma(NVG).METHODS:We retrospectively evaluated the surgical outcome of the BGI with Supramid©3/0 ripco... AIM:To report the outcome of Baerveldt glaucoma implant(BGI)with Supramid©ripcord use in neovascular glaucoma(NVG).METHODS:We retrospectively evaluated the surgical outcome of the BGI with Supramid©3/0 ripcord stent in patients with NVG.No tube ligation or venting slits were performed.Supramid was removed after 3mo if the target intraocular pressure(IOP)was not achieved.Surgical success was defined as IOP≤21 mm Hg with(qualified success)or without IOP-lowering medications(complete success).RESULTS:Twenty-six eyes from 24 patients were included in the study.The median duration of follow-up was 4[interquartile range(IQR)=1-5]y,ranging from 0.5 to 5y.IOP decreased by a mean of 24.2 mm Hg(59.7%);from a mean of 40.5±12.6 mm Hg at baseline to 16.3±11.9 mm Hg,P≤0.001.The number of glaucoma medications reduced from a median of 5(IQR=5-6)to 1(IQR=0-2,P≤0.001)at the final follow-up.Overall success rates were 88.0%at 1y,34.8%at 3y,66.7%at 4y,and 50%at 5y.Hypertensive phase(HP)in the first 3mo occurred in 15/26 eyes(57.7%)with a mean IOP of 31.1 mm Hg.CONCLUSION:BGI with Supramid©ripcord stent gives close to 90%of the overall survival rate at the final follow-up without significant early hypotony.However,early HP is still a challenge. 展开更多
关键词 neovascular glaucoma Supramid ripcord stent Baerveldt glaucoma implant
下载PDF
Special stent for draining the abdominal abscess respectively from colon and duodenum:A case report
6
作者 Fu-Long Zhang Jing Xu +5 位作者 Yu-Hong Jiang Yuan-Dong Zhu Qian-Neng Wu Yan Shi Zong-Yuan Zhan Hai Wang 《World Journal of Clinical Cases》 SCIE 2024年第19期3931-3935,共5页
BACKGROUND Postoperative abdominal infections are an important and heterogeneous health challenge.Many samll abdominal abscesses are resolved with antibiotics,but larger or symptomatic abscesses may require procedural... BACKGROUND Postoperative abdominal infections are an important and heterogeneous health challenge.Many samll abdominal abscesses are resolved with antibiotics,but larger or symptomatic abscesses may require procedural management.CASE SUMMARY A 65-year-old male patient who suffered operation for the left hepatocellular carcinoma eight months ago,came to our hospital with recurrent abdominal pain,vomit,and fever for one month.Abdominal computed tomography showed that a big low-density dumbbell-shaped mass among the liver and intestine.Colonoscopy showed a submucosal mass with a fistula at colon of liver region.Gastroscopy showed a big rupture on the submucosal mass at the descending duodenum and a fistula at the duodenal bulb.Under colonoscopy,the brown liquid and pus were drained from the mass with“special stent device”.Under gastroscopy,we closed the rupture of the mass with a loop and six clips for purse stitching at the descending duodenum,and the same method as colonoscopy was used to drain the brown liquid and pus from the mass.The symptom of abdominal pain,vomit and fever were relieved after the treatment.CONCLUSION The special stent device could be effectively for draining the abdominal abscess respectively from colon and duodenum. 展开更多
关键词 Abdominal abscess stent Draining GASTROSCOPY COLONOSCOPY Case report
下载PDF
Vertebral Artery Stenting for Acute Multiple Cerebral Infarctions Caused by Vertebral Artery Dissection After Massage:A Case Report
7
作者 Ying-Xue Cui Chuan-Jin Song +3 位作者 Xue-Si Hou Gui-Lin Liu Xu Ji Shao-Song Wang 《Chinese Medical Sciences Journal》 CAS CSCD 2024年第2期149-154,共6页
Vertebral artery dissection is a rare pathology that can cause ischemic stroke in young people.Cervical massage,especially improper pulling manipulation,is a cause of vertebral artery dissection.We present a case of 3... Vertebral artery dissection is a rare pathology that can cause ischemic stroke in young people.Cervical massage,especially improper pulling manipulation,is a cause of vertebral artery dissection.We present a case of 32-year old woman who developed acute multiple posterior circulation ischemic cerebral infarctions as a result of left vertebral artery V4 segment dissection after receiving neck massage.She underwent emergency vertebral artery stent implantation at the site of the dissection.Symptoms were relieved the day after treatment.The patient recovered without adverse complications or endovascular restenosis in the following year. 展开更多
关键词 vertebral artery dissection acute ischemic stroke stent implantation endovascular therapy
下载PDF
Transparent cap adjusted the stent placed for stenosis after endoscopic injection of esophageal varices:A case report
8
作者 Fu-Long Zhang Jing Xu +8 位作者 Yuan-Dong Zhu Qian-Neng Wu Yan Shi Lei Fang Dan Zhou Hai Wang Chao-JunHuang Chun-Hua Zhou Qun Zhu 《World Journal of Clinical Cases》 SCIE 2024年第15期2614-2620,共7页
BACKGROUND The stent embedded in the esophageal mucosa is one of the complications after stenting for esophageal stricture.We present a case of stent adjustment with the aid of a transparent cap after endoscopic injec... BACKGROUND The stent embedded in the esophageal mucosa is one of the complications after stenting for esophageal stricture.We present a case of stent adjustment with the aid of a transparent cap after endoscopic injection of an esophageal varices stent.CASE SUMMARY A 61-year-old male patient came to the hospital with discomfort of the chest after the stent implanted for the stenosis because of endoscopic injection of esophageal varices.The gastroscopy was performed,and the stent embedded into the esophageal mucosa.At first,we pulled the recycling line for shrinking the stent,however,the mucosa could not be removed from the stent.Then a forceps was performed to remove the mucosa in the stent,nevertheless,the bleeding form the mucosa was obvious.And then,we used a transparent cap to scrape the mucosa along the stent,and the mucosa were removed successfully without bleeding.CONCLUSION A transparent cap helps gastroscopy to remove the mucosa embedded in the stent after endoscopic injection of the esophageal varices stent. 展开更多
关键词 stent Transparent cap STENOSIS Endoscopic injection Esophageal varices Case report
下载PDF
Long-term outcomes of titanium-nitride-oxide coated stents and drug-eluting stents in acute coronary syndrome:A systematic review and meta-analysis
9
作者 Muhammad Ahmed Ali Fahim Afia Salman +12 位作者 Hira Anas Khan Syed Muhammad Hasan Muskan FatimaBhojani Sarah Aslam Amna Zia Ul Haq Vishal Reddy Bejugam Beena Muntaha Nasir Wajiha Gul Abdul Moeed Abdelrahman S Abdalla Muhammad Majid Muhammad Sohaib Asghar Md Al Hasibuzzaman 《World Journal of Cardiology》 2024年第5期293-305,共13页
BACKGROUND In severe cases of coronary artery disease,percutaneous coronary intervention provide promising results.The stent used could be a drug-eluting stent(DES)or a titanium-nitride-oxide coated stent(TiNOS).AIM T... BACKGROUND In severe cases of coronary artery disease,percutaneous coronary intervention provide promising results.The stent used could be a drug-eluting stent(DES)or a titanium-nitride-oxide coated stent(TiNOS).AIM To compare the 5-year effectiveness and safety of the two stent types.METHODS The following systematic review and meta-analysis was conducted in accordance with the preferred reporting items for systematic reviews and meta-analysis guidelines,and PubMed/MEDLINE,Scopus,and Cochrane Central were searched from inception till August 2023.Primary outcomes were major adverse cardiac events(MACE),cardiac death,myocardial infarction(MI),cardiac death or MI,and ischemia-driven total lesion revascularization(ID-TLR).RESULTS Four randomized controlled trials(RCT),which analyzed a sum total of 3045 patients with acute coronary syndrome(ACS)after a median follow-up time of 5 years were included.Though statistically insignificant,an increase in the ID-TLR was observed in patients receiving TiNOSs vs DESs.In addition,MI,cardiac death and MI,and definite stent thrombosis(DST)were significantly decreased in the TiNOS arm.Baseline analysis revealed no significant results with meta-regression presenting non-ST elevated MI(NSTEMI)as a statistically significant covariate in the outcome of MACE.CONCLUSION TiNOS was found to be superior to DES in terms of MI,cardiac death or MI,and DST outcomes,however,the effect of the two stent types on ID-TLR and MACE was not significant.A greater number of studies are required to establish an accurate comparison of patient outcomes in TiNOS and DES. 展开更多
关键词 stentS DRUG-ELUTING Major adverse cardiac events All-cause death META-ANALYSIS
下载PDF
Numerical Study of the Biomechanical Behavior of a 3D Printed Polymer Esophageal Stent in the Esophagus by BP Neural Network Algorithm
10
作者 Guilin Wu Shenghua Huang +7 位作者 Tingting Liu Zhuoni Yang Yuesong Wu Guihong Wei Peng Yu Qilin Zhang Jun Feng Bo Zeng 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第3期2709-2725,共17页
Esophageal disease is a common disorder of the digestive system that can severely affect the quality of life andprognosis of patients. Esophageal stenting is an effective treatment that has been widely used in clinica... Esophageal disease is a common disorder of the digestive system that can severely affect the quality of life andprognosis of patients. Esophageal stenting is an effective treatment that has been widely used in clinical practice.However, esophageal stents of different types and parameters have varying adaptability and effectiveness forpatients, and they need to be individually selected according to the patient’s specific situation. The purposeof this study was to provide a reference for clinical doctors to choose suitable esophageal stents. We used 3Dprinting technology to fabricate esophageal stents with different ratios of thermoplastic polyurethane (TPU)/(Poly-ε-caprolactone) PCL polymer, and established an artificial neural network model that could predict the radial forceof esophageal stents based on the content of TPU, PCL and print parameter. We selected three optimal ratios formechanical performance tests and evaluated the biomechanical effects of different ratios of stents on esophagealimplantation, swallowing, and stent migration processes through finite element numerical simulation and in vitrosimulation tests. The results showed that different ratios of polymer stents had different mechanical properties,affecting the effectiveness of stent expansion treatment and the possibility of postoperative complications of stentimplantation. 展开更多
关键词 Finite element method 3D printing polymer esophageal stent artificial neural network
下载PDF
Arterial Duct Stenting Versus Modified Blalock-Taussig Shunt in Patient with Ductal-Dependent Pulmonary Circulation: Systematic Review & Meta-Analysis
11
作者 Ketut Putu Yasa Nyoman Satria Sadu Bhaskara Putu Febry Krisna Pertiwi 《Congenital Heart Disease》 SCIE 2024年第2期139-156,共18页
Objective:Patients with ductal-dependent pulmonary circulation require alternative bloodflow to provide and maintain adequate oxygenation.Modified Blalock-Taussig Shunt(MBTS)has been the standard for providing such a ... Objective:Patients with ductal-dependent pulmonary circulation require alternative bloodflow to provide and maintain adequate oxygenation.Modified Blalock-Taussig Shunt(MBTS)has been the standard for providing such a result.Currently,less invasive methods such as Arterial Duct(AD)stenting have been performed as alter-natives.This study aims to compare the outcome of AD stenting and MBTS.Method:Systematic research was performed in online databases using the PRISMA protocol.The outcomes measured were 30-day mortality,com-plication,unplanned intervention,oxygen saturation,duration of hospital,and ICU length of stay.Any compara-tive study provided with full text is included.The outcome of each study was analyzed using a trandom effects model with relative risk and mean difference as the effect size.Bias risk assessment was conducted using the New-castle-Ottawa Scale.All analyses were performed using Review Manager 5.4.1.Result:A total of 11 studies with 3154 samples included in this study.There is no significant difference in 30-day mortality between the two groups(p-value=0.10).However,there is significantly less complication(RR 0.53[0.35,0.82];p-value=0.004)and unplanned intervention(RR 0.59[0.38,0.92];p-value=0.02)in the AD stent group.Comparison of the Nakata index showed no significant difference(p-value=0.88).Post-operative oxygen saturation was measured signifi-cantly higher in the AD stenting(MD 1.80[0.85,2.74];p-value=0.0002).However,AD stent group shows sig-nificantly lower long-term oxygen saturation(MD-8.43[-14.38,-2.48];p-value=0.005).Both hospital and ICU length of stay was significantly shorter in the AD stent group(MD-8.30[-11.13,-5.48];p-value<0.00001;MD-5.09[-7.79,-2.38];p-value=0.0002).Conclusion:AD stenting provides comparable outcomes relative to MBTS as it provides less complication and unplanned intervention and higher post-procedural O2 saturation.However,MBTS proved its superiority in maintaining higher long-term oxygen saturation and still became the preferred option to manage complex cases where stenting is either challenging or unsuccessful. 展开更多
关键词 Duct-dependent pulmonary circulation arterial duct stenting modified Blalock-Taussig shunt
下载PDF
Role of endoscopic-ultrasound-guided biliary drainage with electrocautery-enhanced lumen-apposing metal stent for palliation of malignant biliary obstruction
12
作者 Smit S Deliwala Emad Qayed 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第7期1981-1985,共5页
In this editorial,we discuss the article by Peng et al in the recent issue of the World Journal of Gastrointestinal Surgery,focusing on the evolving role of endoscopicultrasound-guided biliary drainage(EUS-BD)with ele... In this editorial,we discuss the article by Peng et al in the recent issue of the World Journal of Gastrointestinal Surgery,focusing on the evolving role of endoscopicultrasound-guided biliary drainage(EUS-BD)with electrocautery lumen apposing metal stent(LAMS)for distal malignant biliary obstruction.Therapeutic endoscopy has rapidly advanced in decompression techniques,with growing evidence of its safety and efficacy surpassing percutaneous and surgical approaches.While endoscopic retrograde cholangiopancreatography(ERCP)has been the gold standard for biliary decompression,its failure rate approaches 10.0%,prompting the exploration of alternatives like EUS-BD.This random-effects meta-analysis demonstrated high technical and clinical success of over 90.0% and an adverse event rate of 17.5%,mainly in the form of stent dysfunction.Outcomes based on stent size were not reported but the majority used 6 mm and 8 mm stents.As the body of literature continues to demonstrate the effectiveness of this technique,the challenges of stent dysfunction need to be addressed in future studies.One strategy that has shown promise is placement of double-pigtail stents,only 18% received the prophylactic intervention in this study.We expect this to improve with time as the technique continues to be refined and standardized.The results above establish EUS-BD with LAMS as a reliable alternative after failed ERCP and considering EUS to ERCP upfront in the same session is an effective strategy.Given the promising results,studies must explore the role of EUS-BD as first-line therapy for biliary decompression. 展开更多
关键词 Endoscopic-ultrasound Malignant biliary obstruction Lumen apposing metal stent CHOLEDOCHODUODENOSTOMY Hepaticogastrostomy
下载PDF
Endoscopic ultrasound-guided tissue sampling induced pancreatic duct leak resolved by the placement of a pancreatic stent:A case report
13
作者 Ki-Hyun Kim Chang Hwan Park +1 位作者 Eunae Cho Yohan Lee 《World Journal of Clinical Cases》 SCIE 2024年第9期1677-1684,共8页
BACKGROUND Pancreatic ductal leaks complicated by endoscopic ultrasonography-guided tissue sampling(EUS-TS)can manifest as acute pancreatitis.CASE SUMMARY A 63-year-old man presented with persistent abdominal pain and... BACKGROUND Pancreatic ductal leaks complicated by endoscopic ultrasonography-guided tissue sampling(EUS-TS)can manifest as acute pancreatitis.CASE SUMMARY A 63-year-old man presented with persistent abdominal pain and weight loss.Diagnosis:Laboratory findings revealed elevated carbohydrate antigen 19-9(5920 U/mL)and carcinoembryonic antigen(23.7 ng/mL)levels.Magnetic resonance imaging of the pancreas revealed an approximately 3 cm ill-defined space-occupying lesion in the inferior aspect of the head,with severe encasement of the superior mesenteric artery.Pancreatic ductal adenocarcinoma was confirmed after pathological examination of specimens obtained by EUS-TS using the fanning method.Interventions and outcomes:The following day,the patient experienced severe abdominal pain with high amylase(265 U/L)and lipase(1173 U/L)levels.Computed tomography of the abdomen revealed edematous wall thickening of the second portion of the duodenum with adjacent fluid collections and a suspicious leak from either the distal common bile duct or the main pancreatic duct in the head.Endoscopic retrograde cholangiopancreatography revealed dye leakage in the head of the main pancreatic duct.Therefore,a 5F 7 cm linear plastic stent was deployed into the pancreatic duct to divert the pancreatic juice.The patient’s abdominal pain improved immediately after pancreatic stent insertion,and amylase and lipase levels normalized within a week.Neoadjuvant chemotherapy was then initiated.CONCLUSION Using the fanning method in EUS-TS can inadvertently cause damage to the pancreatic duct and may lead to clinically significant pancreatitis.Placing a pancreatic stent may immediately resolve acute pancreatitis and shorten the waiting time for curative therapy.When using the fanning method during EUSTS,ductal structures should be excluded to prevent pancreatic ductal leakage. 展开更多
关键词 Endoscopic ultrasound-guided tissue sampling PANCREATITIS Pancreatic duct leak Pancreatic stent Case report
下载PDF
Percutaneous transhepatic stenting for acute superior mesenteric vein stenosis after pancreaticoduodenectomy with portal vein reconstruction:A case report
14
作者 Chen Lin Zi-Yan Wang +3 位作者 Liang-Bo Dong Zhi-Wei Wang Ze-Hui Li Wei-Bin Wang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第4期1195-1202,共8页
BACKGROUND Percutaneous transhepatic stent placement has become a common strategy for the postoperative treatment of portal vein(PV)/superior mesenteric veins(SMV)stenosis/occlusion.It has been widely used after liver... BACKGROUND Percutaneous transhepatic stent placement has become a common strategy for the postoperative treatment of portal vein(PV)/superior mesenteric veins(SMV)stenosis/occlusion.It has been widely used after liver transplantation surgery;however,reports on stent placement for acute PV/SMV stenosis after pancreatic surgery within postoperative 3 d are rare.CASE SUMMARY Herein,we reported a case of intestinal edema and SMV stenosis 2 d after pancreatic surgery.The patient was successfully treated using stent grafts.Although the stenosis resolved after stent placement,complications,including bleeding,pancreatic fistula,bile leakage,and infection,made the treatment highly challenging.The use of anticoagulants was adjusted multiple times to prevent venous thromboembolism and the risk of bleeding.After careful treatment,the patient stabilized,and stent placement effectively managed postoperative PV/SMV stenosis.CONCLUSION Stent placement is effective and feasible for treating acute PV/SMV stenosis after pancreatic surgery even within postoperative 3 d. 展开更多
关键词 PANCREATICODUODENECTOMY Portal vein reconstruction Portal vein stenosis Portal vein stent Case report
下载PDF
Transarterial chemoembolization plus stent placement for hepatocellular carcinoma with main portal vein tumor thrombosis:A meta-analysis
15
作者 Wei-Fan Sui Jian-Yun Li Jian-Hua Fu 《World Journal of Clinical Oncology》 2024年第3期447-455,共9页
BACKGROUND Portal vein tumor thrombus is an important indicator of poor prognosis in patients with hepatocellular carcinoma.Transarterial chemoembolization is recommended as the standard first-line therapy for unresec... BACKGROUND Portal vein tumor thrombus is an important indicator of poor prognosis in patients with hepatocellular carcinoma.Transarterial chemoembolization is recommended as the standard first-line therapy for unresectable hepatocellular carcinoma.Portal vein stent placement is a safe and effective therapy for promptly restoring flow and relieving portal hypertension caused by tumor thrombus.AIM To assess the clinical significance of transarterial chemoembolization plus stent placement for the treatment of hepatocellular carcinoma with main portal vein tumor thrombosis.METHODS We searched English and Chinese databases,assessed the quality of the included studies,analyzed the characteristic data,tested heterogeneity,explored heterogeneity,and tested publication bias.RESULTS In total,eight clinical controlled trials were included.The results showed that the pressure in the main portal vein after stent placement was significantly lower than that with no stent placement.The cumulative stent patency and survival rates at 6 and 12 months were lower in the transarterial chemoembolization+stent placement group than in the transarterial chemoembolization+stent placement+brachytherapy/radiotherapy group.The survival rates of patients treated with transarterial chemoembolization+stent placement for 6 and 12 months were higher than those of patients treated with transarterial chemoembolization alone.CONCLUSION For Chinese patients with hepatocellular carcinoma with main portal vein tumor thrombosis,transarterial chemoembolization plus stenting is effective.Transarterial chemoembolization+stent placement is more effective than transarterial chemoembolization alone.Transarterial chemoembolization+stent placement+brachytherapy/radiotherapy is more effective than transarterial chemoembolization+stenting. 展开更多
关键词 Hepatocellular carcinoma Transarterial chemoembolization Portal vein tumor thrombus stent META-ANALYSIS
下载PDF
Recognition and management of stent malposition in the portal vein during endoscopic retrograde cholangiopancreatography:A case report
16
作者 Rui Wu Feng Zhang +4 位作者 Hao Zhu Ming-Dong Liu Yu-Zheng Zhuge Lei Wang Bin Zhang 《World Journal of Gastrointestinal Endoscopy》 2024年第7期432-438,共7页
BACKGROUND Portal vein injury is an uncommon complication of endoscopic retrograde cholangiopancreatography(ERCP),for which stent malpositioning in the portal vein is very rare and can lead to fatal events.We report a... BACKGROUND Portal vein injury is an uncommon complication of endoscopic retrograde cholangiopancreatography(ERCP),for which stent malpositioning in the portal vein is very rare and can lead to fatal events.We report a case of biliary stent migration to the portal vein and a novel method for its safe removal under the guidance of portal angiography.Moreover,we reviewed the literature and summarized reports on the identification and management of this condition.CASE SUMMARY A 59-year-old woman with pancreatic cancer presented with abdominal pain and a high fever 20 days after the placement of two plastic biliary stents under the guidance of ERCP.Blood cultures and laboratory tests revealed sepsis,which was treated with antibiotics.A contrast-enhanced computed tomography scan revealed that one of the biliary stents in the main portal vein was malpositioned.To safely remove the stent,portal angiography was performed to visualize the portal vein and to allow the management of any bleeding.The two stents were removed without obvious bleeding,and an uncovered self-expanding metal stent was placed in the common bile duct for drainage.The patient had an uneventful 6-month follow-up period,except for self-resolving portal vein thrombosis.CONCLUSION The combination of endoscopic and angiographic techniques allowed uneventful management of stent malposition in the portal vein. 展开更多
关键词 Endoscopic retrograde cholangiopancreatography stent malposition Portal vein Portal angiography Case report
下载PDF
Unveiling the potential of electrocautery-enhanced lumen-apposing metal stents in endoscopic ultrasound-guided biliary drainage
17
作者 Meer M Chisthi 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第7期1956-1959,共4页
This editorial delves into Peng et al's article,published in the World Journal of Gastrointestinal Surgery.Peng et al's meta-analysis investigates the effectiveness of electrocautery-enhanced lumen-apposing me... This editorial delves into Peng et al's article,published in the World Journal of Gastrointestinal Surgery.Peng et al's meta-analysis investigates the effectiveness of electrocautery-enhanced lumen-apposing metal stents(ECE-LAMS)in ultrasound-guided biliary drainage for alleviating malignant biliary obstruction.Examining 14 studies encompassing 620 participants,the research underscores a robust technical success rate of 96.7%,highlighting the efficacy of ECE-LAMS,particularly in challenging cases which have failed endoscopic retrograde cholangio pancreatography.A clinical success rate of 91.0% underscores its impact on symptom alleviation,while a reasonably tolerable adverse event rate of 17.5% is observed.However,the 7.3% re-intervention rate stresses the need for post-procedural monitoring.Subgroup analyses validate consistent outcomes,bolstering the applicability of ECE-LAMS.These findings advocate for the adoption of ECELAMS as an appropriate approach for biliary palliation,urging further exploration in real-world clinical contexts.They offer valuable insights for optimizing interventions targeting malignant biliary obstruction management. 展开更多
关键词 Biliary drainage Electrocautery-enhanced lumen-apposing metal stent Endoscopic retrograde cholangiopancreatography Endoscopic ultrasound Malignant biliary obstruction
下载PDF
Stent A pancreaticojejunostomy after pancreatoduodenectomy:Is it always necessary?
18
作者 Dimitrios Symeonidis Dimitris Zacharoulis +4 位作者 Georgios Tzovaras Labrini Kissa Athina A Samara Eleana Petsa Konstantinos Tepetes 《World Journal of Methodology》 2024年第3期23-29,共7页
The establishment of a postoperative pancreatic fistula(POPF)is considered the most common and,concomitantly,the most serious complication associated with pancreaticoduodenectomy(PD).The search for either technical mo... The establishment of a postoperative pancreatic fistula(POPF)is considered the most common and,concomitantly,the most serious complication associated with pancreaticoduodenectomy(PD).The search for either technical modifications of the operative technique or pharmaceutical interventions that could possibly aid in decreasing the incidence of this often-devastating complication appears justified.The stenting of the pancreatic duct,with the use of either internal or external stents,has been evaluated in this direction.In theory,it is an approach that could eliminate many pathophysiological factors responsible for the occurrence of a POPF.The purpose of the present study was to review the current data regarding the role of pancreatic duct stenting on the incidence of POPF,after PD,by using PubMed and Reference Citation Analysis.In general,previous studies seem to highlight the superiority of external stents over their internal counterparts in regard to the incidence of POPF;this is at the cost,however,of increased morbidity associated mainly with the stent removal.Certainly,the use of an internal stent is a less invasive approach with acceptable results and is definitely deprived of the drawbacks arising through the complete diversion of pancreatic juice from the gastrointestinal tract.Bearing in mind the scarcity of high-quality data on the subject,an approach of reserving stent placement for the high-risk for POPF patients and individualizing the selection between the use of an internal or an external stent according to the distinct characteristics of each individual case scenario appears appropriate. 展开更多
关键词 PANCREATICODUODENECTOMY Postoperative pancreatic fistula Pancreatic stent PANCREATICOJEJUNOSTOMY
下载PDF
Endoscopic-ultrasound-guided biliary drainage with placement of electrocautery-enhanced lumen-apposing metal stent for palliation of malignant biliary obstruction:Updated meta-analysis
19
作者 Zu-Xiang Peng Fang-Fang Chen +5 位作者 Wen Tang Xu Zeng Hong-Juan Du Ru-Xian Pi Hong-Ming Liu Xiao-Xiao Lu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第3期907-920,共14页
BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant bili... BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant biliary obstruction after endoscopic retrograde cholangiopancreatography(ERCP)failure.However,most of the studies that have assessed its efficacy and safety were small and hetero-geneous.Prior meta-analyses of six or fewer studies that were published 2 years ago were therefore underpowered to yield convincing evidence.AIM To update the efficacy and safety of ECE-LAMS for treatment of biliary ob-struction after ERCP failure.METHODS We searched PubMed,EMBASE,and Scopus databases from the inception of the ECE technique to May 13,2022.Primary outcome measure was pooled technical success rate,and secondary outcomes were pooled rates of clinical success,re-intervention,and adverse events.Meta-analysis was performed using a random-effects model following Freeman-Tukey double-arcsine transformation in R soft-ware(version 4.1.3).RESULTS Fourteen eligible studies involving 620 participants were ultimately included.The pooled rate of technical success was 96.7%,and clinical success was 91.0%.Adverse events were reported in 17.5%of patients.Overall reinter-vention rate was 7.3%.Subgroup analyses showed results were generally consistent.CONCLUSION ECE-LAMS has favorable success with acceptable adverse events in relieving biliary obstruction when ERCP is impossible.The consistency of results across most subgroups suggested that this is a generalizable approach. 展开更多
关键词 Biliary obstruction Biliary drainage Electrocautery-enhanced lumen-apposing metal stents Endoscopic ultrasound Endoscopic retrograde cholangiopancreatography failure
下载PDF
Endoscopic ultrasound-guided biliary drainage using electrocauteryenhanced lumen-apposing metal stent for malignant biliary obstruction:A promising procedure
20
作者 Si-Ze Wu 《World Journal of Clinical Cases》 SCIE 2024年第26期5859-5862,共4页
In this editorial,we comment on the article by Peng et al.Palliative drainage for biliary obstruction resulting from unresectable malignant lesions includes internal and external drainage.The procedures of biliary dra... In this editorial,we comment on the article by Peng et al.Palliative drainage for biliary obstruction resulting from unresectable malignant lesions includes internal and external drainage.The procedures of biliary drainage are usually guided by fluoroscopy or transcutaneous ultrasound,endoscopic ultrasound(EUS),or both.Endoscopic retrograde cholangiopancreatography(ERCP)has been primarily recommended for the management of biliary obstruction,while EUS-guided biliary drainage and percutaneous transhepatic biliary drainage(PTBD)are alternative choices for cases where ERCP has failed or is impossible.PTBD is limited by shortcomings of a higher rate of adverse events,more reinterventions,and severe complications.EUS-guided biliary drainage has a lower rate of adverse events than PTBD.EUS-guided biliary drainage with electrocautery-enhanced lumen-apposing metal stent(ECE-LAMS)enables EUS-guided biliaryenteric anastomosis to be performed in a single step and does not require prior bile duct puncture or a guidewire.The present meta-analysis showed that ECELAMS has a high efficacy and safety in relieving biliary obstruction in general,although the results of LAMS depending on the site of biliary obstruction.This study has highlighted the latest advances with a larger sample-based comprehensive analysis. 展开更多
关键词 Malignant biliary obstruction Biliary drainage Percutaneous transhepatic biliary drainage Electrocautery-enhanced lumen-apposing metal stents Transcutaneous ultrasound Endoscopic ultrasound Endoscopic retrograde cholangiopancreatography
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部