In large-diameter shield tunnels,applying the double-layer lining structure can improve the load-bearing properties and maintain the stability of segmental lining.The secondary lining thickness is a key parameter in t...In large-diameter shield tunnels,applying the double-layer lining structure can improve the load-bearing properties and maintain the stability of segmental lining.The secondary lining thickness is a key parameter in the design of a double lining structure,which is worth being explored.Based on an actual large-diameter shield tunnel,loading model tests are carried out to investigate the effect of the secondary lining thickness on the mechanical behaviours of the double lining structure.The test results show that within the range of secondary lining thicknesses discussed,the load-bearing limit of the double-layer lining increases with growing secondary lining thickness.As a passive support,the secondary lining acts as an auxiliary load-bearing structure by contacting the segment.And changes in secondary lining thickness have a significant effect on the contact state between the segment and secondary lining,with both the contact pressure level and the contact area between the two varying.For double-layer lining structures in large-diameter shield tunnels,it is proposed that the stiffness of the secondary lining needs to be matched to the stiffness of the segment,as this allows them to have a coordinated deformation and a good joint load-bearing effect.展开更多
This paper proposes a type of double-layer charge liner fabricated using chemical vapor deposition(CVD)that has tungsten as its inner liner.The feasibility of this design was evaluated through penetration tests.Double...This paper proposes a type of double-layer charge liner fabricated using chemical vapor deposition(CVD)that has tungsten as its inner liner.The feasibility of this design was evaluated through penetration tests.Double-layer charge liners were fabricated by using CVD to deposit tungsten layers on the inner surfaces of pure T2 copper liners.The microstructures of the tungsten layers were analyzed using a scanning electron microscope(SEM).The feasibility analysis was carried out by pulsed X-rays,slug-retrieval test and static penetration tests.The shaped charge jet forming and penetration law of inner tungsten-coated double-layer liner were studied by numerical simulation method.The results showed that the double-layer liners could form well-shaped jets.The errors between the X-ray test results and the numerical results were within 11.07%.A slug-retrieval test was found that the retrieved slug was similar to a numerically simulated slug.Compared with the traditional pure copper shaped charge jet,the penetration depth of the double-layer shaped charge liner increased by 11.4% and>10.8% respectively.In summary,the test results are good,and the numerical simulation is in good agreement with the test,which verified the feasibility of using the CVD method to fabricate double-layer charge liners with a high-density and high-strength refractory metal as the inner liner.展开更多
The Songliao Basin(SLB)covers an area of approximately 260,000 km2in northeastern Asia and preserves a continuous and complete Cretaceous terrestrial record(Wang et al.,2021).The region is the most important petrolife...The Songliao Basin(SLB)covers an area of approximately 260,000 km2in northeastern Asia and preserves a continuous and complete Cretaceous terrestrial record(Wang et al.,2021).The region is the most important petroliferous sedimentary basin in China because of its continual annual oil and gas equivalent production of tens of millions of tons(ca.220–440 million barrels per year)since 1959.The SLB was previously thought to have developed on Hercynian basement and accumulated continuous sedimentary deposits during the Late Jurassic and Cretaceous(Wan et al.,2013;Wang et al.,2016).展开更多
Double-layered microcapsule corrosion inhibitors were developed by sodium monofluorophosphate as the core material,polymethyl methacrylate as the inner wall material,and polyvinyl alcohol as the outer wall material co...Double-layered microcapsule corrosion inhibitors were developed by sodium monofluorophosphate as the core material,polymethyl methacrylate as the inner wall material,and polyvinyl alcohol as the outer wall material combining the solvent evaporation method and spray drying method.The protection by the outer capsule wall was used to prolong the service life of the corrosion inhibitor.The dispersion,encapsulation,thermal stability of microcapsules,and the degradation rate of capsule wall in concrete pore solution were analyzed by ultra-deep field microscopy,scanning electron microscopy,thermal analyzer,and sodium ion release rate analysis.The microcapsules were incorporated into mortar samples containing steel reinforcement,and the effects of double-layered microcapsule corrosion inhibitors on the performance of the cement matrix and the actual corrosion-inhibiting effect were analyzed.The experimental results show that the double-layered microcapsules have a moderate particle size and uniform distribution,and the capsules were completely wrapped.The microcapsules as a whole have good thermal stability below 230 ℃.The monolayer membrane structure microcapsules completely broke within 1 day in the simulated concrete pore solution,and the double-layer membrane structure prolonged the service life of the microcapsules to 80 days in the simulated concrete pore solution before the core material was completely released.The mortar samples containing steel reinforcement incorporated with the double-layered microcapsule corrosion inhibitors still maintained a higher corrosion potential than the monolayer microcapsule corrosion inhibitors control group at 60 days.The incorporation of double-layered microcapsules into the cement matrix has no significant adverse effect on the setting time and early strength.展开更多
To understand the mesoscopic mechanism of clayey soil in view of macroscopic behavior, it is essential to quantitatively calculate the electric double-layer repulsion between arbitrarily inclined clay particles.Howeve...To understand the mesoscopic mechanism of clayey soil in view of macroscopic behavior, it is essential to quantitatively calculate the electric double-layer repulsion between arbitrarily inclined clay particles.However, suitable calculation methods with high efficiency and accuracy are still rare at present in literature. Based on a great number of numerical calculations of the repulsion between two inclined platy clay particles, explicit empirical formulae for estimating electric double-layer repulsion between clay particles are put forward. Comparison between the empirical solutions and corresponding numerical results shows that the proposed formulae have a reasonable accuracy, and application of the presented formula is easy and efficient.展开更多
The nanocomposite BaFe12O19/α-Fe and nanocrystalline α-Fe microfibers with diameters of 1-5 μm, high aspect ratios and large specific areas are prepared by the citrate gel transformation and reduction process. The ...The nanocomposite BaFe12O19/α-Fe and nanocrystalline α-Fe microfibers with diameters of 1-5 μm, high aspect ratios and large specific areas are prepared by the citrate gel transformation and reduction process. The nanocomposite BaFe12O19/α-Fe microfibers show some exchange-coupling interactions largely arising from the magnetization hard (BaFe12019) and soft (a-Fe) nanoparticles. For the microwave absorptions, the double-layer structures consisting of the nanocomposite BaFe12O19/α-Fe and α-Fe microfibers each exhibit a wide band and strong absorption behavior. When the nanocomposite BaFel2O19/α-Fe microfibers are used as a matching layer of 2.3 mm in thickness and a-Fe microfibers as an absorbing layer of 1.2 mm in thickness, the optimal reflection loss (RL) achieves -47 dB at 15.6 GHz, the absorption bandwidth is about 12.7 GHz ranging from 5.3 to 18 GHz, exceeding -20 dB, which covers 72.5% C-band (4.2-8.2 GHz) and whole X-band (8.2-12.4 GHz) and Ku-band (12.4-18 GHz). The enhanced absorption properties of these double-layer absorbers are mainly ascribed to the improvement in impedance matching ability and microwave multi-reflection largely resulting from the dipolar polarization, interfacial polarization, exchange-coupling interaction, and small size effect.展开更多
Microwave absorption properties of the nanocrystalline strontium ferrite (SrFe12O19) and iron (α-Fe) microfibers for single-layer and double-layer structures are investigated in a frequency range of 2 GHz 18 GHz....Microwave absorption properties of the nanocrystalline strontium ferrite (SrFe12O19) and iron (α-Fe) microfibers for single-layer and double-layer structures are investigated in a frequency range of 2 GHz 18 GHz. For the singlelayer absorbers, the nanocrystalline SrFe12O19 microfibers show some microwave absorptions at 6 GHz 18 GHz, with a minimum reflection loss (RL) value of -11.9 dB at 14.1 GHz for a specimen thickness of 3.0 mm, while for the nanocrystalline α-Fe microfibers, their absorptions largely take place at 15 GHz-18 GHz with the RL value exceeding -10 dB, with a minimum .RL value of about -24 dB at 17.5 GHz for a specimen thickness of 0.7 mm. For the doublelayer absorber with an absorbing layer of α-Fe microfibers with a thickness of 0.7 mm and matching layer of SrFe12O19 microfibers with a thickness of 1.3 ram, the minimum RL value is about -63 dB at 16.4 GHz and the absorption band width is about 6.7 GHz ranging from 11.3 GHz to 18 GHz with the RL value exceeding -10 dB which covers the whole Ku-band (12.4 GHz 18 GHz) and 27% of X-band (8.2 GHz 12.4 GHz).展开更多
In order to establish the relationship between the measured dynamic response and the health status of long-span bridges, a double-layer model updating method for steel-concrete composite beam cable-stayed bridges is p...In order to establish the relationship between the measured dynamic response and the health status of long-span bridges, a double-layer model updating method for steel-concrete composite beam cable-stayed bridges is proposed. Measured frequencies are selected as the first-layer reference data, and the mass of the bridge deck, the grid density, the modulus of concrete and the ballast on the side span are modified by using a manual tuning technique. Measured global positioning system (GPS) data is selected as the second-layer reference data, and the degradation of the integral structure stiffness EI of the whole bridge is taken into account for the second-layer model updating by using the finite element iteration algorithm. The Nanpu Bridge in Shanghai is taken as a case to verify the applicability of the proposed model updating method. After the first-layer model updating, the standard deviation of modal frequencies is smaller than 7%. After the second-layer model updating, the error of the deflection of the mid-span is smaller than 10%. The integral structure stiffness of the whole bridge decreases about 20%. The research results show a good agreement between the calculated response and the measured response.展开更多
In order to increase the fatigue life (FL) of road wheels (RW), a kind of double layer rubber flange (DLRF) is put forward. It consists of two layers of rubber, where metal wires are laid in the inner layer and the ou...In order to increase the fatigue life (FL) of road wheels (RW), a kind of double layer rubber flange (DLRF) is put forward. It consists of two layers of rubber, where metal wires are laid in the inner layer and the outer layer has no inlaid metal wires. Stress, strain and temperature field of DLRF were calculated with ANSYS finite element analysis (FEA) software, FL of DLRF RW was also computed with fracture mechanics fatigue theory. The results of computation indicate that the heat generated in RW's rubber flange (RF) can be reduced by the use of DLRF, and the FL of RW can be increased without affecting the mechanical intensity of RW.展开更多
The aim of the study was to develop actarit double-layered osmotic pump tablets to overcome the weak points of actarit common tablets, such as short half-life and large plasma concentration fluctuations. Single factor...The aim of the study was to develop actarit double-layered osmotic pump tablets to overcome the weak points of actarit common tablets, such as short half-life and large plasma concentration fluctuations. Single factor experiment and orthogonal test were applied to optimize the formulation;the pharmacokinetic study was performed in beagle dogs adopting actarit common tablets as reference tablets. The optimal formulation was as follows: drug layer: 150 mg actarit, 240 mg PEO-N80, 50 mg NaCl;push layer: 140 mg PEO-WSR303, 20 mg NaCl;coating solution: 30 g cellulose acetate and 6 g PEG 4000 in 1000 ml 94% acetone solution, 60 mg coating weight gain. The pharmacokinetic study showed that T max was prolonged by the contrast of commercial common tablets with constant drug release rate, but the bioavailability was equivalent. And a good in vivo –in vitro correlation of the actarit osmotic pump tablets was also established. The designed actarit osmotic pump tablets can be applied for rheumatoid arthritis, proposing a promising replacement for the marked common products.展开更多
AIM To investigate the efficacy of double-layered covered stent in the treatment of malignant oesophageal obstructions.METHODS A systematic review and meta-analysis was performed following the PRISMA process. Pub Med(...AIM To investigate the efficacy of double-layered covered stent in the treatment of malignant oesophageal obstructions.METHODS A systematic review and meta-analysis was performed following the PRISMA process. Pub Med(Medline),EMBASE(Excerpta Medical Database),AMED(Allied and Complementary medicine Database),Scopus and online content,were searched for studies reporting on the Ni Ti-S polyurethane-covered double oesophageal stent for the treatment of malignant dysphagia. Weighted pooled outcomes were synthesized with a random effects model to account for clinical heterogeneity. All studies reporting the outcome of palliative management of dysphagia due to histologically confirmed malignant oesophageal obstruction using double-layered covered nitinol stent were included. The level of statistical significance was set at α = 0.05.RESULTS Six clinical studies comprising 250 patients in total were identified. Pooled technical success of stent insertion was 97.2%(95%CI: 94.8%-98.9%; I2 = 5.8%). Pooled complication rate was 27.6%(95%CI: 20.7%-35.2%; I2 = 41.9%). Weighted improvement of dysphagia on a scale of 0-5 scoring system was-2.00 [95%CI:-2.29%-(-1.72%); I2 = 87%]. Distal stent migration was documented in 10 out of the 250 cases examined.Pooled stent migration rate was 4.7%(95%CI: 2.5%-7.7%; I2 = 0%). Finally,tumour overgrowth was reported in 34 out of the 250 cases with pooled rate of tumour overgrowth of 11.2%(95%CI: 3.7%-22.1%; I2 = 82.2%). No funnel plot asymmetry to suggest publication bias(bias = 0.39,P = 0.78). In the sensitivity analysis all results were largely similar between the fixed and random effects models.CONCLUSION The double-layered nitinol stent provides immediate relief of malignant dysphagia with low rates of stent migration and tumour展开更多
Based on non-Darcian flow law described by exponent and threshold gradient within a double-layered soil, the classic theory of one-dimensional consolidation of double-layered soil was modified to consider the change o...Based on non-Darcian flow law described by exponent and threshold gradient within a double-layered soil, the classic theory of one-dimensional consolidation of double-layered soil was modified to consider the change of vertical total stress with depth and time together. Because of the complexity of governing equations, the numerical solutions were obtained in detail by finite difference method. Then, the numerical solutions were compared with the analytical solutions in condition that non-Darcian flow law was degenerated to Dary's law, and the comparison results show that numerical solutions are reliable. Finally, consolidation behavior of double-layered soil with different parameters was analyzed, and the results show that the consolidation rate of double-layered soil decreases with increasing the value of exponent and threshold of non-Darcian flow, and the exponent and threshold gradient of the first soil layer greatly influence the consolidation rate of double-layered soil. The larger the ratio of the equivalent water head of external load to the total thickness of double-layered soil, the larger the rate of the consolidation, and the similitude relationship in classical consolidation theory of double-layered soil is not satisfied. The other consolidation behavior of double-layered soil with non-Darcian flow is the same as that with Darcy's law.展开更多
As an important scheme of future global mobile satellite communication systems to provide multimedia service, a Double-Layer Satellite Network (DLSN) with MEO satellites and LEO satellites is proposed. The Inter-Orb...As an important scheme of future global mobile satellite communication systems to provide multimedia service, a Double-Layer Satellite Network (DLSN) with MEO satellites and LEO satellites is proposed. The Inter-Orbit-Links (IOLs) between layers is an essential factor, which affects the performances of the DLSN systems. Considering certain constellation parameters, the geometric characteristics of IOLs are described and the connectivity of MEO satellites and LEO satellites in the DLSN is analyzed. By computer simulation, the results show that IOLs should be selectively established according to certain parameters rather than the simple in-sight principle.展开更多
The velocity structures of flow through vertically double-layered vegetation(VDLV)as well as single-layered rigid vegetation(SLV)were investigated computationally with a three-dimensional(3D)Reynolds stress turbulence...The velocity structures of flow through vertically double-layered vegetation(VDLV)as well as single-layered rigid vegetation(SLV)were investigated computationally with a three-dimensional(3D)Reynolds stress turbulence model,using the computational fluid dynamics(CFD)code FLUENT.The detailed velocity distribution was explored with a varying initial Froude number(Fr),with consideration of the steady subcritical flow conditions of an inland tsunami.In VDLV flows,the numerical model successfully captured the inflection point in the profiles of mean streamwise velocities in the mixing-layer region around the top of short submerged vegetation.An upward and downward movement of flow occurred at the positions located just behind the tall and short vegetation,respectively.Overall,higher streamwise velocities were observed in the upper vegetation layer due to high porosity,with Pr=98%(sparse vegetation,where Pr is the porosity),as compared to those in the lower vegetation layer,which had comparatively low porosity,with Pr=91%(dense vegetation).A rising trend of velocities was found as the flow passed through the vegetation region,followed by a clear sawtooth distribution,as compared to the regions just upstream and downstream of vegetation where the flow was almost uniform.In VDLV flows,a rising trend in the flow resistance was observed with the increase in the initial Froude number,i.e.,Fr?0.67,0.70,and 0.73.However,the flow resistance in the case of SLV was relatively very low.The numerical results also show the flow structures within the vicinity of short and tall vegetation,which are difficult to attain through experimental measurements.展开更多
A simple, precise and accurate method was developed and validated for the determination of allicin release from alliin/alliinase double-layer tablets. According to Appendix XC Ⅱ of Chinese Pharmacopoeia 2010 edition ...A simple, precise and accurate method was developed and validated for the determination of allicin release from alliin/alliinase double-layer tablets. According to Appendix XC Ⅱ of Chinese Pharmacopoeia 2010 edition Volume II, a small glass-method was adopted at the rotational speed of 100 r/min using 100 mL phosphate buffer (pH 6.8) as release medium. The release amount was determined by HPLC with a C18 column (250 mm × 4.6 mm, 5 μm) using the mobile phase consisting of methanol -0.4% carboxylic acid (65:35) at a flow rate of 1 mL/min and UV detection at 242 nm. The current method demonstrates good linearity over the range 4.052- 405.2 μg/mL (r2=0.9999) with an average recovery of 105.5%(RSD= 1.25%). The accumulative release of alliin/alliinase double-layer tablets had good homogeneity for withinand betweenbatches. The method established is simple, accurate and repeatable for the determination of allicin release from alliin/alliinase double-layer tablets.展开更多
Numerous models have been proposed to reduce the classification error of Naive Bayes by weakening its attribute independence assumption and some have demonstrated remarkable error performance. Considering that ensembl...Numerous models have been proposed to reduce the classification error of Naive Bayes by weakening its attribute independence assumption and some have demonstrated remarkable error performance. Considering that ensemble learning is an effective method of reducing the classifmation error of the classifier, this paper proposes a double-layer Bayesian classifier ensembles (DLBCE) algorithm based on frequent itemsets. DLBCE constructs a double-layer Bayesian classifier (DLBC) for each frequent itemset the new instance contained and finally ensembles all the classifiers by assigning different weight to different classifier according to the conditional mutual information. The experimental results show that the proposed algorithm outperforms other outstanding algorithms.展开更多
To further investigate the one-dimensional(1D)rheological consolidation mechanism of double-layered soil,the fractional derivative Merchant model(FDMM)and the non-Darcian flow model with the non-Newtonian index are re...To further investigate the one-dimensional(1D)rheological consolidation mechanism of double-layered soil,the fractional derivative Merchant model(FDMM)and the non-Darcian flow model with the non-Newtonian index are respectively introduced to describe the deformation of viscoelastic soil and the flow of pore water in the process of consolidation.Accordingly,an 1D rheological consolidation equation of double-layered soil is obtained,and its numerical analysis is performed by the implicit finite difference method.In order to verify its validity,the numerical solutions by the present method for some simplified cases are compared with the results in the related literature.Then,the influence of the revelent parameters on the rheological consolidation of double-layered soil are investigated.Numerical results indicate that the parameters of non-Darcian flow and FDMM of the first soil layer greatly influence the consolidation rate of double-layered soil.As the decrease of relative compressibility or the increase of relative permeability between the lower soil and the upper soil,the dissipation rate of excess pore water pressure and the settlement rate of the ground will be accelerated.Increasing the relative thickness of soil layer with high permeability or low compressibility will also accelerate the consolidation rate of double-layered soil.展开更多
The adsorption capacity and absorption rate for electrolyte onto activated carbon are important parameters used to characterize activated carbon electric double-layer capacitor electrodes. In this paper the pore struc...The adsorption capacity and absorption rate for electrolyte onto activated carbon are important parameters used to characterize activated carbon electric double-layer capacitor electrodes. In this paper the pore structure of typical commercial activated carbons, and various Mn-doped activated carbons prepared on a laboratory scale, are described. The pore structure was character-ized by N2 adsorption/desorption isotherms. Isotherms for K+ adsorption onto these activated carbons from the aqueous phase were also obtained. The experimental, equilibrium K+ adsorption data were fitted to the Langmuir, Freundlich or Temkin equations. Adsorption of K+ onto the activated carbons was measured and plotted as a function of time. The adsorption kinetic data were modeled by either pseudo-first or pseudo-second order equations. The Elvoich equation, a liquid film diffusion and an intra-particle diffusion model were used to fit the kinetic data. The results indicate that the adsorption of K+ onto activated carbon is influenced by many factors including pore size distribution, specific surface area and the surface chemistry of the activated carbons. The Temkin equation best describes the equilibrium adsorption data. The pseudo-second order model exactly describes the whole adsorption process, which is controlled by both liquid film and intra-particle diffusion.展开更多
The transmission upper limit of a double-layer frequency selective surface (FSS) with two infinitely thin metal arrays is pre- sented based on the study of the general equivalent transmission line model of a double-...The transmission upper limit of a double-layer frequency selective surface (FSS) with two infinitely thin metal arrays is pre- sented based on the study of the general equivalent transmission line model of a double-layer FSS. Results of theoretical analyses, numerical simulations and experiments show that this transmis- sion upper limit is independent of the array and the element, which indicates that it is impossible to achieve a transmission upper limit higher than this one under a given incident and dielectric- supporting condition by the design of the periodic array. Both the applicable condition and the possible application of the transmis- sion upper limit are discussed. The results show that the transmis- sion upper limit not only has a good reachability, but also provides a key to effectively improve the transmission performance of a double-layer FSS or more complex frequency selective structures.展开更多
For delivering the nanoscaled extraordinary characteristics in macroscopical bulk,it is essential to integrate two-dimensional nanosheets into threedimensional(3D)porous monoliths,alternatively called as 3D architectu...For delivering the nanoscaled extraordinary characteristics in macroscopical bulk,it is essential to integrate two-dimensional nanosheets into threedimensional(3D)porous monoliths,alternatively called as 3D architectures,3D networks,or aerogels.The intersupported structure of porous monolithic 3D graphene(3DG)can prevent aggregation or restacking of graphene individuals,and the interconnected sp^(2) network of 3DG not only can provide the highway for the transport of electron/phonon but also can present continual cavities/channels for mass transfer.This review summarizes the synthesis methodology of 3DG porous monoliths and highlights the application for electric double-layer capacitors.Present challenges and future prospects about the manufacture and application of 3DG are also discussed.展开更多
基金supported by the National Natural Science Foundation of China(Grant Nos.52178398,51991394,and 51278424).
文摘In large-diameter shield tunnels,applying the double-layer lining structure can improve the load-bearing properties and maintain the stability of segmental lining.The secondary lining thickness is a key parameter in the design of a double lining structure,which is worth being explored.Based on an actual large-diameter shield tunnel,loading model tests are carried out to investigate the effect of the secondary lining thickness on the mechanical behaviours of the double lining structure.The test results show that within the range of secondary lining thicknesses discussed,the load-bearing limit of the double-layer lining increases with growing secondary lining thickness.As a passive support,the secondary lining acts as an auxiliary load-bearing structure by contacting the segment.And changes in secondary lining thickness have a significant effect on the contact state between the segment and secondary lining,with both the contact pressure level and the contact area between the two varying.For double-layer lining structures in large-diameter shield tunnels,it is proposed that the stiffness of the secondary lining needs to be matched to the stiffness of the segment,as this allows them to have a coordinated deformation and a good joint load-bearing effect.
基金funded by the China Postdoctoral Science Foundation(Grant No.2022M721614)the opening project of State Key Laboratory of Explosion Science and Technology,Beijing Institute of Technology(Grant No.KFJJ23-07M)。
文摘This paper proposes a type of double-layer charge liner fabricated using chemical vapor deposition(CVD)that has tungsten as its inner liner.The feasibility of this design was evaluated through penetration tests.Double-layer charge liners were fabricated by using CVD to deposit tungsten layers on the inner surfaces of pure T2 copper liners.The microstructures of the tungsten layers were analyzed using a scanning electron microscope(SEM).The feasibility analysis was carried out by pulsed X-rays,slug-retrieval test and static penetration tests.The shaped charge jet forming and penetration law of inner tungsten-coated double-layer liner were studied by numerical simulation method.The results showed that the double-layer liners could form well-shaped jets.The errors between the X-ray test results and the numerical results were within 11.07%.A slug-retrieval test was found that the retrieved slug was similar to a numerically simulated slug.Compared with the traditional pure copper shaped charge jet,the penetration depth of the double-layer shaped charge liner increased by 11.4% and>10.8% respectively.In summary,the test results are good,and the numerical simulation is in good agreement with the test,which verified the feasibility of using the CVD method to fabricate double-layer charge liners with a high-density and high-strength refractory metal as the inner liner.
基金supports from the International Continental Scientific Drilling Programfunded by the National Natural Science Foundation of China(Grant Nos.41790453,41472304,42102129,42102135 and 41972313)+2 种基金Natural Science Foundation of Jilin Province(Grant No.20170101001JC)the National Key Research&Development Program of China(Grant No.2019YFC0605402)China Geological Survey(Grant No.DD20189702)。
文摘The Songliao Basin(SLB)covers an area of approximately 260,000 km2in northeastern Asia and preserves a continuous and complete Cretaceous terrestrial record(Wang et al.,2021).The region is the most important petroliferous sedimentary basin in China because of its continual annual oil and gas equivalent production of tens of millions of tons(ca.220–440 million barrels per year)since 1959.The SLB was previously thought to have developed on Hercynian basement and accumulated continuous sedimentary deposits during the Late Jurassic and Cretaceous(Wan et al.,2013;Wang et al.,2016).
基金Fund by the National Key Technology Research and Development Program of the Ministry of Science and Technology of China (No.2018YFD1101002-03)。
文摘Double-layered microcapsule corrosion inhibitors were developed by sodium monofluorophosphate as the core material,polymethyl methacrylate as the inner wall material,and polyvinyl alcohol as the outer wall material combining the solvent evaporation method and spray drying method.The protection by the outer capsule wall was used to prolong the service life of the corrosion inhibitor.The dispersion,encapsulation,thermal stability of microcapsules,and the degradation rate of capsule wall in concrete pore solution were analyzed by ultra-deep field microscopy,scanning electron microscopy,thermal analyzer,and sodium ion release rate analysis.The microcapsules were incorporated into mortar samples containing steel reinforcement,and the effects of double-layered microcapsule corrosion inhibitors on the performance of the cement matrix and the actual corrosion-inhibiting effect were analyzed.The experimental results show that the double-layered microcapsules have a moderate particle size and uniform distribution,and the capsules were completely wrapped.The microcapsules as a whole have good thermal stability below 230 ℃.The monolayer membrane structure microcapsules completely broke within 1 day in the simulated concrete pore solution,and the double-layer membrane structure prolonged the service life of the microcapsules to 80 days in the simulated concrete pore solution before the core material was completely released.The mortar samples containing steel reinforcement incorporated with the double-layered microcapsule corrosion inhibitors still maintained a higher corrosion potential than the monolayer microcapsule corrosion inhibitors control group at 60 days.The incorporation of double-layered microcapsules into the cement matrix has no significant adverse effect on the setting time and early strength.
基金the financial support from"The Fundamental Research Funds for the Central Universities"(Grant No.2017XKQY052)
文摘To understand the mesoscopic mechanism of clayey soil in view of macroscopic behavior, it is essential to quantitatively calculate the electric double-layer repulsion between arbitrarily inclined clay particles.However, suitable calculation methods with high efficiency and accuracy are still rare at present in literature. Based on a great number of numerical calculations of the repulsion between two inclined platy clay particles, explicit empirical formulae for estimating electric double-layer repulsion between clay particles are put forward. Comparison between the empirical solutions and corresponding numerical results shows that the proposed formulae have a reasonable accuracy, and application of the presented formula is easy and efficient.
基金supported by the National Natural Science Foundation of China(Grant Nos.51274106 and 51202091)the Natural Science Foundation ofJiangsu Provincial Higher Education,China(Grant No.12KJA430001)+2 种基金the Science and Technology Support Program of Jiangsu Province,China(GrantNos.BE2012143 and BE2013071)the Jiangsu Provincial Postgraduate Cultivation and Innovation Project,China(Grant No.CXZZ13 0662)the PriorityAcademic Program Development of Jiangsu Higher Education Institutions,China(Grant No.1033000003)
文摘The nanocomposite BaFe12O19/α-Fe and nanocrystalline α-Fe microfibers with diameters of 1-5 μm, high aspect ratios and large specific areas are prepared by the citrate gel transformation and reduction process. The nanocomposite BaFe12O19/α-Fe microfibers show some exchange-coupling interactions largely arising from the magnetization hard (BaFe12019) and soft (a-Fe) nanoparticles. For the microwave absorptions, the double-layer structures consisting of the nanocomposite BaFe12O19/α-Fe and α-Fe microfibers each exhibit a wide band and strong absorption behavior. When the nanocomposite BaFel2O19/α-Fe microfibers are used as a matching layer of 2.3 mm in thickness and a-Fe microfibers as an absorbing layer of 1.2 mm in thickness, the optimal reflection loss (RL) achieves -47 dB at 15.6 GHz, the absorption bandwidth is about 12.7 GHz ranging from 5.3 to 18 GHz, exceeding -20 dB, which covers 72.5% C-band (4.2-8.2 GHz) and whole X-band (8.2-12.4 GHz) and Ku-band (12.4-18 GHz). The enhanced absorption properties of these double-layer absorbers are mainly ascribed to the improvement in impedance matching ability and microwave multi-reflection largely resulting from the dipolar polarization, interfacial polarization, exchange-coupling interaction, and small size effect.
基金supported by the Aviation Science Foundation,China (Grant No.2009ZF52063)the Research Fund for the Doctoral Program of Higher Education of China (Grant No.20103227110006)the Jiangsu Provincial Postgraduate Cultivation and Innovation Project,China (Grant No.CX10B-257Z)
文摘Microwave absorption properties of the nanocrystalline strontium ferrite (SrFe12O19) and iron (α-Fe) microfibers for single-layer and double-layer structures are investigated in a frequency range of 2 GHz 18 GHz. For the singlelayer absorbers, the nanocrystalline SrFe12O19 microfibers show some microwave absorptions at 6 GHz 18 GHz, with a minimum reflection loss (RL) value of -11.9 dB at 14.1 GHz for a specimen thickness of 3.0 mm, while for the nanocrystalline α-Fe microfibers, their absorptions largely take place at 15 GHz-18 GHz with the RL value exceeding -10 dB, with a minimum .RL value of about -24 dB at 17.5 GHz for a specimen thickness of 0.7 mm. For the doublelayer absorber with an absorbing layer of α-Fe microfibers with a thickness of 0.7 mm and matching layer of SrFe12O19 microfibers with a thickness of 1.3 ram, the minimum RL value is about -63 dB at 16.4 GHz and the absorption band width is about 6.7 GHz ranging from 11.3 GHz to 18 GHz with the RL value exceeding -10 dB which covers the whole Ku-band (12.4 GHz 18 GHz) and 27% of X-band (8.2 GHz 12.4 GHz).
基金The Special Project of the Ministry of Construction ofChina (No.20060909).
文摘In order to establish the relationship between the measured dynamic response and the health status of long-span bridges, a double-layer model updating method for steel-concrete composite beam cable-stayed bridges is proposed. Measured frequencies are selected as the first-layer reference data, and the mass of the bridge deck, the grid density, the modulus of concrete and the ballast on the side span are modified by using a manual tuning technique. Measured global positioning system (GPS) data is selected as the second-layer reference data, and the degradation of the integral structure stiffness EI of the whole bridge is taken into account for the second-layer model updating by using the finite element iteration algorithm. The Nanpu Bridge in Shanghai is taken as a case to verify the applicability of the proposed model updating method. After the first-layer model updating, the standard deviation of modal frequencies is smaller than 7%. After the second-layer model updating, the error of the deflection of the mid-span is smaller than 10%. The integral structure stiffness of the whole bridge decreases about 20%. The research results show a good agreement between the calculated response and the measured response.
文摘In order to increase the fatigue life (FL) of road wheels (RW), a kind of double layer rubber flange (DLRF) is put forward. It consists of two layers of rubber, where metal wires are laid in the inner layer and the outer layer has no inlaid metal wires. Stress, strain and temperature field of DLRF were calculated with ANSYS finite element analysis (FEA) software, FL of DLRF RW was also computed with fracture mechanics fatigue theory. The results of computation indicate that the heat generated in RW's rubber flange (RF) can be reduced by the use of DLRF, and the FL of RW can be increased without affecting the mechanical intensity of RW.
文摘The aim of the study was to develop actarit double-layered osmotic pump tablets to overcome the weak points of actarit common tablets, such as short half-life and large plasma concentration fluctuations. Single factor experiment and orthogonal test were applied to optimize the formulation;the pharmacokinetic study was performed in beagle dogs adopting actarit common tablets as reference tablets. The optimal formulation was as follows: drug layer: 150 mg actarit, 240 mg PEO-N80, 50 mg NaCl;push layer: 140 mg PEO-WSR303, 20 mg NaCl;coating solution: 30 g cellulose acetate and 6 g PEG 4000 in 1000 ml 94% acetone solution, 60 mg coating weight gain. The pharmacokinetic study showed that T max was prolonged by the contrast of commercial common tablets with constant drug release rate, but the bioavailability was equivalent. And a good in vivo –in vitro correlation of the actarit osmotic pump tablets was also established. The designed actarit osmotic pump tablets can be applied for rheumatoid arthritis, proposing a promising replacement for the marked common products.
文摘AIM To investigate the efficacy of double-layered covered stent in the treatment of malignant oesophageal obstructions.METHODS A systematic review and meta-analysis was performed following the PRISMA process. Pub Med(Medline),EMBASE(Excerpta Medical Database),AMED(Allied and Complementary medicine Database),Scopus and online content,were searched for studies reporting on the Ni Ti-S polyurethane-covered double oesophageal stent for the treatment of malignant dysphagia. Weighted pooled outcomes were synthesized with a random effects model to account for clinical heterogeneity. All studies reporting the outcome of palliative management of dysphagia due to histologically confirmed malignant oesophageal obstruction using double-layered covered nitinol stent were included. The level of statistical significance was set at α = 0.05.RESULTS Six clinical studies comprising 250 patients in total were identified. Pooled technical success of stent insertion was 97.2%(95%CI: 94.8%-98.9%; I2 = 5.8%). Pooled complication rate was 27.6%(95%CI: 20.7%-35.2%; I2 = 41.9%). Weighted improvement of dysphagia on a scale of 0-5 scoring system was-2.00 [95%CI:-2.29%-(-1.72%); I2 = 87%]. Distal stent migration was documented in 10 out of the 250 cases examined.Pooled stent migration rate was 4.7%(95%CI: 2.5%-7.7%; I2 = 0%). Finally,tumour overgrowth was reported in 34 out of the 250 cases with pooled rate of tumour overgrowth of 11.2%(95%CI: 3.7%-22.1%; I2 = 82.2%). No funnel plot asymmetry to suggest publication bias(bias = 0.39,P = 0.78). In the sensitivity analysis all results were largely similar between the fixed and random effects models.CONCLUSION The double-layered nitinol stent provides immediate relief of malignant dysphagia with low rates of stent migration and tumour
基金Projects(50878191,51109092)supported by the National Natural Science Foundation of China
文摘Based on non-Darcian flow law described by exponent and threshold gradient within a double-layered soil, the classic theory of one-dimensional consolidation of double-layered soil was modified to consider the change of vertical total stress with depth and time together. Because of the complexity of governing equations, the numerical solutions were obtained in detail by finite difference method. Then, the numerical solutions were compared with the analytical solutions in condition that non-Darcian flow law was degenerated to Dary's law, and the comparison results show that numerical solutions are reliable. Finally, consolidation behavior of double-layered soil with different parameters was analyzed, and the results show that the consolidation rate of double-layered soil decreases with increasing the value of exponent and threshold of non-Darcian flow, and the exponent and threshold gradient of the first soil layer greatly influence the consolidation rate of double-layered soil. The larger the ratio of the equivalent water head of external load to the total thickness of double-layered soil, the larger the rate of the consolidation, and the similitude relationship in classical consolidation theory of double-layered soil is not satisfied. The other consolidation behavior of double-layered soil with non-Darcian flow is the same as that with Darcy's law.
基金National Natural Science Foundation of China(60532030)
文摘As an important scheme of future global mobile satellite communication systems to provide multimedia service, a Double-Layer Satellite Network (DLSN) with MEO satellites and LEO satellites is proposed. The Inter-Orbit-Links (IOLs) between layers is an essential factor, which affects the performances of the DLSN systems. Considering certain constellation parameters, the geometric characteristics of IOLs are described and the connectivity of MEO satellites and LEO satellites in the DLSN is analyzed. By computer simulation, the results show that IOLs should be selectively established according to certain parameters rather than the simple in-sight principle.
文摘The velocity structures of flow through vertically double-layered vegetation(VDLV)as well as single-layered rigid vegetation(SLV)were investigated computationally with a three-dimensional(3D)Reynolds stress turbulence model,using the computational fluid dynamics(CFD)code FLUENT.The detailed velocity distribution was explored with a varying initial Froude number(Fr),with consideration of the steady subcritical flow conditions of an inland tsunami.In VDLV flows,the numerical model successfully captured the inflection point in the profiles of mean streamwise velocities in the mixing-layer region around the top of short submerged vegetation.An upward and downward movement of flow occurred at the positions located just behind the tall and short vegetation,respectively.Overall,higher streamwise velocities were observed in the upper vegetation layer due to high porosity,with Pr=98%(sparse vegetation,where Pr is the porosity),as compared to those in the lower vegetation layer,which had comparatively low porosity,with Pr=91%(dense vegetation).A rising trend of velocities was found as the flow passed through the vegetation region,followed by a clear sawtooth distribution,as compared to the regions just upstream and downstream of vegetation where the flow was almost uniform.In VDLV flows,a rising trend in the flow resistance was observed with the increase in the initial Froude number,i.e.,Fr?0.67,0.70,and 0.73.However,the flow resistance in the case of SLV was relatively very low.The numerical results also show the flow structures within the vicinity of short and tall vegetation,which are difficult to attain through experimental measurements.
文摘A simple, precise and accurate method was developed and validated for the determination of allicin release from alliin/alliinase double-layer tablets. According to Appendix XC Ⅱ of Chinese Pharmacopoeia 2010 edition Volume II, a small glass-method was adopted at the rotational speed of 100 r/min using 100 mL phosphate buffer (pH 6.8) as release medium. The release amount was determined by HPLC with a C18 column (250 mm × 4.6 mm, 5 μm) using the mobile phase consisting of methanol -0.4% carboxylic acid (65:35) at a flow rate of 1 mL/min and UV detection at 242 nm. The current method demonstrates good linearity over the range 4.052- 405.2 μg/mL (r2=0.9999) with an average recovery of 105.5%(RSD= 1.25%). The accumulative release of alliin/alliinase double-layer tablets had good homogeneity for withinand betweenbatches. The method established is simple, accurate and repeatable for the determination of allicin release from alliin/alliinase double-layer tablets.
基金supported by National Natural Science Foundation of China (Nos. 61073133, 60973067, and 61175053)Fundamental Research Funds for the Central Universities of China(No. 2011ZD010)
文摘Numerous models have been proposed to reduce the classification error of Naive Bayes by weakening its attribute independence assumption and some have demonstrated remarkable error performance. Considering that ensemble learning is an effective method of reducing the classifmation error of the classifier, this paper proposes a double-layer Bayesian classifier ensembles (DLBCE) algorithm based on frequent itemsets. DLBCE constructs a double-layer Bayesian classifier (DLBC) for each frequent itemset the new instance contained and finally ensembles all the classifiers by assigning different weight to different classifier according to the conditional mutual information. The experimental results show that the proposed algorithm outperforms other outstanding algorithms.
基金Project(51578511)supported by the National Natural Science Foundation of China。
文摘To further investigate the one-dimensional(1D)rheological consolidation mechanism of double-layered soil,the fractional derivative Merchant model(FDMM)and the non-Darcian flow model with the non-Newtonian index are respectively introduced to describe the deformation of viscoelastic soil and the flow of pore water in the process of consolidation.Accordingly,an 1D rheological consolidation equation of double-layered soil is obtained,and its numerical analysis is performed by the implicit finite difference method.In order to verify its validity,the numerical solutions by the present method for some simplified cases are compared with the results in the related literature.Then,the influence of the revelent parameters on the rheological consolidation of double-layered soil are investigated.Numerical results indicate that the parameters of non-Darcian flow and FDMM of the first soil layer greatly influence the consolidation rate of double-layered soil.As the decrease of relative compressibility or the increase of relative permeability between the lower soil and the upper soil,the dissipation rate of excess pore water pressure and the settlement rate of the ground will be accelerated.Increasing the relative thickness of soil layer with high permeability or low compressibility will also accelerate the consolidation rate of double-layered soil.
基金the financial support from the Research Fund for the Doctoral Program of Higher Education of China (No.2006 0290006)
文摘The adsorption capacity and absorption rate for electrolyte onto activated carbon are important parameters used to characterize activated carbon electric double-layer capacitor electrodes. In this paper the pore structure of typical commercial activated carbons, and various Mn-doped activated carbons prepared on a laboratory scale, are described. The pore structure was character-ized by N2 adsorption/desorption isotherms. Isotherms for K+ adsorption onto these activated carbons from the aqueous phase were also obtained. The experimental, equilibrium K+ adsorption data were fitted to the Langmuir, Freundlich or Temkin equations. Adsorption of K+ onto the activated carbons was measured and plotted as a function of time. The adsorption kinetic data were modeled by either pseudo-first or pseudo-second order equations. The Elvoich equation, a liquid film diffusion and an intra-particle diffusion model were used to fit the kinetic data. The results indicate that the adsorption of K+ onto activated carbon is influenced by many factors including pore size distribution, specific surface area and the surface chemistry of the activated carbons. The Temkin equation best describes the equilibrium adsorption data. The pseudo-second order model exactly describes the whole adsorption process, which is controlled by both liquid film and intra-particle diffusion.
文摘The transmission upper limit of a double-layer frequency selective surface (FSS) with two infinitely thin metal arrays is pre- sented based on the study of the general equivalent transmission line model of a double-layer FSS. Results of theoretical analyses, numerical simulations and experiments show that this transmis- sion upper limit is independent of the array and the element, which indicates that it is impossible to achieve a transmission upper limit higher than this one under a given incident and dielectric- supporting condition by the design of the periodic array. Both the applicable condition and the possible application of the transmis- sion upper limit are discussed. The results show that the transmis- sion upper limit not only has a good reachability, but also provides a key to effectively improve the transmission performance of a double-layer FSS or more complex frequency selective structures.
基金The authors acknowledge the support from National Natural Science Foundation of China(51972168,51672124,21603096)Program for Innovative Talents and Entrepreneur in Jiangsu,State Key Laboratory of Catalytic Materials and Reaction Engineering(RIPP,SINOPEC),and Technical Center of Nano Fabrication and Characterization of Nanjing University.
文摘For delivering the nanoscaled extraordinary characteristics in macroscopical bulk,it is essential to integrate two-dimensional nanosheets into threedimensional(3D)porous monoliths,alternatively called as 3D architectures,3D networks,or aerogels.The intersupported structure of porous monolithic 3D graphene(3DG)can prevent aggregation or restacking of graphene individuals,and the interconnected sp^(2) network of 3DG not only can provide the highway for the transport of electron/phonon but also can present continual cavities/channels for mass transfer.This review summarizes the synthesis methodology of 3DG porous monoliths and highlights the application for electric double-layer capacitors.Present challenges and future prospects about the manufacture and application of 3DG are also discussed.