Objective: To assess the value of helical CT in the di- agnosis of liver diseases. Methods: 59 patients with different liver diseases were examined by two-phase or multi-phase dynamic helical CT. Results: Small hepato...Objective: To assess the value of helical CT in the di- agnosis of liver diseases. Methods: 59 patients with different liver diseases were examined by two-phase or multi-phase dynamic helical CT. Results: Small hepatocellular carcinoma showed a higher density in the arterial phase, and a lower den- sity in the portal vein phase. Large hepatic carcino- ma showed a mixed pattern of higher-density in the arterial phase, and a lower density in the portal vein phase. Metastasis carcinoma showed an 'oxeye sign' in the portal vein phase. Hemangioma was not obvi- ously enhanced in the early arterial phase, marginal- ly enhanced in the arterial phase, and equally-densed in the balanced phase. Conclusion: Two-phase helical CT is of value in im- proving the detection rate of or determining the fea- tures of hepatic diseases by two-phase helical dyna- mic scan (2.0-3.0 ml/s speed, and delay time 25- 30 s and 70-85 s).展开更多
In helical cone-beam computed tomography(CT), Feldkamp-Davis-Kress(FDK) based image reconstruction algorithms are by far the most popular. However, artifacts are commonly met in the presence of lateral projection trun...In helical cone-beam computed tomography(CT), Feldkamp-Davis-Kress(FDK) based image reconstruction algorithms are by far the most popular. However, artifacts are commonly met in the presence of lateral projection truncation. The reason is that the ramp filter is global. To restrain the truncation artifacts, an approximate reconstruction formula is proposed based on the Derivative-Hilbert-Backprojection(DHB) framework. In the method, the first order derivative filter is followed by the Hilbert transform. Since the filtered projection values are almost zero by the first order derivative filter, the following Hilbert transform has little influence on the projection values, even though the projections are laterally truncated. The proposed method has two main advantages. First, it has comparable computational efficiency and image quality as well as the conventional helical FDK algorithm for non-truncated projections. The second advantage is that images can be reconstructed with acceptable quality and much lower computational cost in comparison to the Laplace operator based algorithm in cases with truncated projections. To point out the advantages of our method, simulations on the computer and real data experiments on our laboratory industrial cone-beam CT are conducted. The simulated and experimental results demonstrate that the method is feasible for image reconstruction in the case of projection truncation.展开更多
To explore the value of helical CT volume rendering technique (VRT) in post-operative evaluation of screw fixation of axis fractures.Methods There were 21 cases of screw fixation of axis fractures between February 200...To explore the value of helical CT volume rendering technique (VRT) in post-operative evaluation of screw fixation of axis fractures.Methods There were 21 cases of screw fixation of axis fractures between February 2002 and May 2004 in the study including six cases with fractures on axis body,five on odontoid process and 10 on axis body and odontoid process.All cases received X-ray plain film,helical CT scanning,multi-planar reformatting(MPR) and VRT.Results Screw fixation through axis body and massa lateralis atlantis was performed in 10 cases and that through axis body and odontoid process in 11.VRT could clearly display full aperture of screw orbit,location of screw and angle of fixation and hence was superior to X-ray plain film and MPR.Multi-angle VRT displayed asymmetrical space of odontoid process and massa lateralis atlantis in four cases and medial deviation of 2~5 mm of half screw in screw fixation through axis body and massa lateralis atlantis in six.Conclusion VRT can eliminate false shadow of fixation screw,clearly display full aperture of screw orbit and hence supply improtant imaging evidence for post-operative evaluation of screw fixation of axis fractures.7 refs,1 fig,1 tab.展开更多
文摘Objective: To assess the value of helical CT in the di- agnosis of liver diseases. Methods: 59 patients with different liver diseases were examined by two-phase or multi-phase dynamic helical CT. Results: Small hepatocellular carcinoma showed a higher density in the arterial phase, and a lower den- sity in the portal vein phase. Large hepatic carcino- ma showed a mixed pattern of higher-density in the arterial phase, and a lower density in the portal vein phase. Metastasis carcinoma showed an 'oxeye sign' in the portal vein phase. Hemangioma was not obvi- ously enhanced in the early arterial phase, marginal- ly enhanced in the arterial phase, and equally-densed in the balanced phase. Conclusion: Two-phase helical CT is of value in im- proving the detection rate of or determining the fea- tures of hepatic diseases by two-phase helical dyna- mic scan (2.0-3.0 ml/s speed, and delay time 25- 30 s and 70-85 s).
基金Supported by the National High Technology Research and Development Program of China(No.2012AA011603)National Nature Science Foundation of China(No.61372172)
文摘In helical cone-beam computed tomography(CT), Feldkamp-Davis-Kress(FDK) based image reconstruction algorithms are by far the most popular. However, artifacts are commonly met in the presence of lateral projection truncation. The reason is that the ramp filter is global. To restrain the truncation artifacts, an approximate reconstruction formula is proposed based on the Derivative-Hilbert-Backprojection(DHB) framework. In the method, the first order derivative filter is followed by the Hilbert transform. Since the filtered projection values are almost zero by the first order derivative filter, the following Hilbert transform has little influence on the projection values, even though the projections are laterally truncated. The proposed method has two main advantages. First, it has comparable computational efficiency and image quality as well as the conventional helical FDK algorithm for non-truncated projections. The second advantage is that images can be reconstructed with acceptable quality and much lower computational cost in comparison to the Laplace operator based algorithm in cases with truncated projections. To point out the advantages of our method, simulations on the computer and real data experiments on our laboratory industrial cone-beam CT are conducted. The simulated and experimental results demonstrate that the method is feasible for image reconstruction in the case of projection truncation.
文摘To explore the value of helical CT volume rendering technique (VRT) in post-operative evaluation of screw fixation of axis fractures.Methods There were 21 cases of screw fixation of axis fractures between February 2002 and May 2004 in the study including six cases with fractures on axis body,five on odontoid process and 10 on axis body and odontoid process.All cases received X-ray plain film,helical CT scanning,multi-planar reformatting(MPR) and VRT.Results Screw fixation through axis body and massa lateralis atlantis was performed in 10 cases and that through axis body and odontoid process in 11.VRT could clearly display full aperture of screw orbit,location of screw and angle of fixation and hence was superior to X-ray plain film and MPR.Multi-angle VRT displayed asymmetrical space of odontoid process and massa lateralis atlantis in four cases and medial deviation of 2~5 mm of half screw in screw fixation through axis body and massa lateralis atlantis in six.Conclusion VRT can eliminate false shadow of fixation screw,clearly display full aperture of screw orbit and hence supply improtant imaging evidence for post-operative evaluation of screw fixation of axis fractures.7 refs,1 fig,1 tab.