期刊文献+
共找到953篇文章
< 1 2 48 >
每页显示 20 50 100
Analytical Model and Topology Optimization of Doubly-fed Induction Generator
1
作者 Lu Sun Haoyu Kang +4 位作者 Jin Wang Zequan Li Jianjun Liu Yiming Ma Libing Zhou 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期162-169,共8页
As the core component of energy conversion for large wind turbines,the output performance of doubly-fed induction generators (DFIGs) plays a decisive role in the power quality of wind turbines.To realize the fast and ... As the core component of energy conversion for large wind turbines,the output performance of doubly-fed induction generators (DFIGs) plays a decisive role in the power quality of wind turbines.To realize the fast and accurate design optimization of DFIGs,this paper proposes a novel hybriddriven surrogate-assisted optimization method.It firstly establishes an accurate subdomain model of DFIGs to analytically predict performance indexes.Furthermore,taking the inexpensive analytical dataset produced by the subdomain model as the source domain and the expensive finite element analysis dataset as the target domain,a high-precision surrogate model is trained in a transfer learning way and used for the subsequent multi-objective optimization process.Based on this model,taking the total harmonic distortion of electromotive force,cogging torque,and iron loss as objectives,and the slot and inner/outer diameters as parameters for optimizing the topology,achieve a rapid and accurate electromagnetic design for DFIGs.Finally,experiments are carried out on a 3MW DFIG to validate the effectiveness of the proposed method. 展开更多
关键词 doubly-fed induction generators Accurate subdomain model Surrogate-assisted Transfer learning
下载PDF
Modeling and small-signal stability analysis of doubly-fed induction generator integrated system 被引量:1
2
作者 Tianming Gu Puyu Wang +3 位作者 Dingyuan Liu Ao Sun Dejian Yang Gangui Yan 《Global Energy Interconnection》 EI CSCD 2023年第4期438-449,共12页
Owing to their stability,doubly-fed induction generator(DFIG)integrated systems have gained considerable interest and are the most widely implemented type of wind turbines and due to the increasing escalation of the w... Owing to their stability,doubly-fed induction generator(DFIG)integrated systems have gained considerable interest and are the most widely implemented type of wind turbines and due to the increasing escalation of the wind generation penetration rate in power systems.In this study,we investigate a DFIG integrated system comprising four modules:(1)a wind turbine that considers the maximum power point tracking and pitch-angle control,(2)induction generator,(3)rotor/grid-side converter with the corresponding control strategy,and(4)AC power grid.The detailed small-signal modeling of the entire system is performed by linearizing the dynamic characteristic equation at the steady-state value.Furthermore,a dichotomy method is proposed based on the maximum eigenvalue real part function to obtain the critical value of the parameters.Root-locus analysis is employed to analyze the impact of changes in the phase-locked loop,short-circuit ratio,and blade inertia on the system stability.Lastly,the accuracy of the small-signal model and the real and imaginary parts of the calculated dominant poles in the theoretical analysis are verified using PSCAD/EMTDC. 展开更多
关键词 doubly-fed induction generator(dfig) Maximum power point tracking DICHOTOMY Small-signal stability
下载PDF
Robust Position Observer for Sensorless Direct Voltage Control of Stand-Alone Ship Shaft Brushless Doubly-Fed Induction Generators 被引量:4
3
作者 Mohamed G.Hussien Yi Liu Wei Xu 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第4期363-376,共14页
The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position obser... The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position observer using the space vector flux relations of BDFIG may achieve the desired voltage control of the power winding(PW)in terms of magnitude and frequency,without any speed/position sensors.The proposed algorithm does not require any additional observers for obtaining the generator speed.The proposed technique can directly achieve the desired DVC based on the estimated rotor position,which may reduce the overall system cost.The stability analysis of the proposed observer is investigated and confirmed with the concept of quadratic Lyapunov function and using the multi-model representation.In addition,the sensitivity analysis of the presented method is confirmed under different issues of parameter uncertainties.Comprehensive results from both simulation and experiments are realized with a prototype wound-rotor BDFIG,which demonstrate the capability and efficacy of the proposed sensorless DVC strategy with good transient behavior under different operating conditions.Furthermore,the analysis confirms the robustness of the proposed observer via the machine parameter changes. 展开更多
关键词 Brushless doubly-fed induction generator(Bdfig) direct voltage control(DVC) PW voltage-oriented vector control rotor position observer ship shaft applications.
下载PDF
Effects of Wind Turbines Equipped with Doubly-fed Induction Generators on Distance Protection 被引量:1
4
作者 Hossein Kazemi KAREGAR Maryam KHODDAM 《电力系统自动化》 EI CSCD 北大核心 2012年第8期128-131,共4页
Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipp... Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipped with doubly-fed induction generators differ fundamentally from synchronous generators.Therefore,more considerations are needed to analyze the performances of the distance protection relays.The protection of a wind farm with distance relay is inspected.By changing the conditions of the wind farm,the characteristics of the distance relay are studied. 展开更多
关键词 距离保护 双馈异步发电机 风力发电机组 配备 可再生能源资源 双馈感应发电机 距离继电器 同步发电机
下载PDF
A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support
5
作者 沈阳武 柯德平 +3 位作者 孙元章 Daniel Kirschen 王轶申 胡元朝 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第7期52-63,共12页
A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient volt... A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter(GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter(RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive(priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method. 展开更多
关键词 doubly-fed induction generator transient rotor current control superconducting magnetic energy storage voltage support
下载PDF
Step-Loading Characteristics of Gas Engine Cogeneration System Using Doubly-Fed Induction Generator in Stand-Alone Operation
6
作者 Tetsuji Daido Yushi Miura +1 位作者 Toshifumi Ise Yuki Sato 《Journal of Energy and Power Engineering》 2014年第3期530-542,共13页
Application of a DFIG (doubly-fed induction generator), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supp... Application of a DFIG (doubly-fed induction generator), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supply is one of important roles for the gas engine eogeneration system. In the case of conventional constant speed of synchronous generator, the amount of the allowed step load is limited to around 30% of the rated power. On the other hand, DFIG is expected to increase the amount of step load during the stand-alone operation. In this paper, it has been demonstrated that an increase in the gas engine speed resulted in an increase in the maximum amount of step load using experimental equipment with a real gas engine. It has been concluded that the proposed system can improve the performance of an emergency power supply at step-loading. 展开更多
关键词 Step load change doubly-fed induction generator gas engine cogeneration system stand-alone operation.
下载PDF
Parameter Deviation Effect Study of the Power Generation Unit on a Doubly-Fed Induction Machine-based Shipboard Propulsion System 被引量:2
7
作者 Kai Ni Yihua Hu Chun Gan 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期339-348,共10页
To lower the difficulty of fault protection,a doubly-fed induction machine based shipboard propulsion system(DFIM-SPS)that is partially power decoupled is presented.In such an intrinsically safe SPS architecture,a syn... To lower the difficulty of fault protection,a doubly-fed induction machine based shipboard propulsion system(DFIM-SPS)that is partially power decoupled is presented.In such an intrinsically safe SPS architecture,a synchronous generator(SG)is employed for power generation,and the accuracy of the parameters of power generation unit(PGU)plays an important role in SPS stable operation.In this paper,the PGU parameter deviations are studied to evaluate the effects on system performance.The models of salient-pole SG,type DC1A excitation system(EXS)and DFIM are illustrated first.Besides,the corresponding control scheme is explained.For the 16 important parameters of PGU,up to 40%of parameter deviations are applied to implement parameter sensitivity analysis.Then,simulation studies are carried out to evaluate the parameter deviation effects on system performance in detail.By defining three parameter deviation effect indicators(PDEIs),the effects on the PGU output variables,which are the terminal voltage and output active power,are studied.Moreover,the increasing rates of PDEIs with different degrees of parameter deviations for the key parameters are analyzed.Furthermore,the overall system performance is investigated for the two most influential PGU parameters.This paper provides some vital clues on SG and EXS parameter identification for DFIM-SPS. 展开更多
关键词 shipboard propulsion system partially power decoupled doubly-fed induction machine synchronous generator parameter deviation
下载PDF
Steady State Analysis of a Doubly Fed Induction Generator 被引量:3
8
作者 Ahmad M. Alkandari S. A. Soliman Mansour H. Abdel-Rahman 《Energy and Power Engineering》 2011年第4期393-400,共8页
In this paper, we present the steady state analysis of a double-fed induction generator (DFIG) adopted for wind power generation. The three-phase induction machine connected to the network, to work as a generator for ... In this paper, we present the steady state analysis of a double-fed induction generator (DFIG) adopted for wind power generation. The three-phase induction machine connected to the network, to work as a generator for wind farms, is excited on the rotor circuit by a slip-frequency current injected to the rotor, from an exciter mounted on the same shaft of the machine. The resulting rotating magnetic field rotates at synchronous speed;as such the generated power has a constant frequency independent of the shaft speed. Effects of the excitation voltage magnitude and phase angle on the active and reactive power are studied, when the machine runs at constant speed. It has been shown that by controlling the excitation voltage magnitude and phase angle would control the mode of operation of the machine;motor mode or generator mode. Furthermore, the effects of the shaft speed on the active and reactive power at constant excitation voltage magnitude and constant phase angle are also investigated. 展开更多
关键词 ASYNCHRONOUS Operation Double FEED induction generator (dfig) WIND Power
下载PDF
An analytic electromagnetic calculation method for performance evolution of doubly fed induction generators for wind turbines 被引量:1
9
作者 张文娟 黄守道 +1 位作者 高剑 CHEN Zhe 《Journal of Central South University》 SCIE EI CAS 2013年第10期2763-2774,共12页
An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of D... An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of DFIG, the modeling for electromagnetic calculation of DFIG was proposed. The electromagnetic calculation of DFIG was divided into three steps: the magnetic flux calculation, parameters derivation and performance checks. For each step, the detailed numeric calculation formulas were all derived. Combining the calculation formulas, the whole electromagnetic calculation procedure was established, which consisted of three iterative calculation loops, including magnetic saturation coefficient, electromotive force and total output power. All of the electromagnetic and performance data of DIFG can be calculated conveniently by the established calculation procedure, which can be used to evaluate the new designed machine. A 1.5 MW DFIG designed by the proposed procedure was built, for which the whole type tests including no-load test, load test and temperature rising test were carried out. The test results have shown that the DFIG satisfies technical requirements and the test data fit well with the calculation results which prove the correctness of the presented calculation method. 展开更多
关键词 ELECTROMAGNETIC calculation DOUBLY fed induction generator(dfig) wind TURBINE
下载PDF
High Voltage Ride-through Control Strategy of Doubly Fed Induction Wind Generators Based on Virtual Impedance 被引量:2
10
作者 XIE Zhen ZHANG Xing YANG Shuying SONG Haihua QU Tingyu 《中国电机工程学报》 EI CSCD 北大核心 2012年第27期I0001-I0001,共1页
关键词 双馈感应发电机 风力发电机组 高电压 虚拟阻抗 控制策略 电网干扰 异步 无功补偿装置
下载PDF
Probabilistic Load Flow Algorithm with the Power Performance of Double-Fed Induction Generators
11
作者 CAO Ruilin XING Jie HOU Meiqian 《Journal of Donghua University(English Edition)》 CAS 2021年第3期206-213,共8页
Probabilistic load flow(PLF)algorithm has been regained attention,because the large-scale wind power integration into the grid has increased the uncertainty of the stable and safe operation of the power system.The PLF... Probabilistic load flow(PLF)algorithm has been regained attention,because the large-scale wind power integration into the grid has increased the uncertainty of the stable and safe operation of the power system.The PLF algorithm is improved with introducing the power performance of double-fed induction generators(DFIGs)for wind turbines(WTs)under the constant power factor control and the constant voltage control in this paper.Firstly,the conventional Jacobian matrix of the alternating current(AC)load flow model is modified,and the probability distributions of the active and reactive powers of the DFIGs are derived by combining the power performance of the DFIGs and the Weibull distribution of wind speed.Then,the cumulants of the state variables in power grid are obtained by improved PLF model and more accurate power probability distributions.In order to generate the probability density function(PDF)of the nodal voltage,Gram-Charlier,Edgeworth and Cornish-Fisher expansions based on the cumulants are applied.Finally,the effectiveness and accuracy of the improved PLF algorithm is demonstrated in the IEEE 14-RTS system with wind power integration,compared with the results of Monte Carlo(MC)simulation using deterministic load flow calculation. 展开更多
关键词 probabilistic load flow(PLF) cumulant method double-fed induction generator(dfig) power performance series expansion
下载PDF
Control of Doubly Fed Induction Generator under Unbalanced Voltages for Reduction of Torque Pulsation
12
作者 S. Wangsathitwong S. Sirisumrannukul +1 位作者 S. Chatratana W. Deleroi 《Journal of Energy and Power Engineering》 2011年第3期243-251,共9页
The unbalanced voltages cause negative effects on the doubly fed induction generator (DFIG) sucn as torque pulsation,and increased stator current. Based on the symmetrical component theory, the torque pulsation is t... The unbalanced voltages cause negative effects on the doubly fed induction generator (DFIG) sucn as torque pulsation,and increased stator current. Based on the symmetrical component theory, the torque pulsation is the consequence of the interaction of stator and rotor currents of different sequences. This paper presents a control technique to reduce the effect of unbalanced voltages on the DFIG in wind energy conversion systems. The negative sequence stator voltage is derived from the unbalanced three phase stator voltages. The compensated rotor voltage in terms of the derived negative sequence stator voltage and slip which minimizes the negative stator and rotor currents is proposed. The results from the simulation of control system with steady state model and dynamic model of the DFIG show that additional control loop with compensated voltage can significantly reduce torque and reactive power pulsations. 展开更多
关键词 Doubly fed induction generator (dfig unbalanced voltages symmetrical components.
下载PDF
Reactive Current Allocation and Control Strategies Improvement of Low Voltage Ride Though for Doubly Fed Induction Wind Turbine Generation System 被引量:36
13
作者 LI Hui FU Bo +2 位作者 YANG Chao ZHAO Bin TANG Xianhu 《中国电机工程学报》 EI CSCD 北大核心 2012年第22期I0004-I0004,22,共1页
为满足风电机组低电压穿越(low voltage ride through,LVRT)的测试要求及其电气模型一致性评估需要,提出考虑向电网注入无功电流的双馈风电机组LVRT的控制策略。在阐述风电机组LVRT测试要求及控制原理的基础上,推导双馈发电机(doubly... 为满足风电机组低电压穿越(low voltage ride through,LVRT)的测试要求及其电气模型一致性评估需要,提出考虑向电网注入无功电流的双馈风电机组LVRT的控制策略。在阐述风电机组LVRT测试要求及控制原理的基础上,推导双馈发电机(doubly fed induction generator,DFIG)定子侧及网侧变流器输出无功电流极限表达式,研究电网电压跌落深度和发电机总输出有功功率对其无功电流极限值的影响规律,进而提出DFIG在LVRT期间的无功电流分配算法和改进的有功、无功功率控制策略。最后,以某实际2 MW双馈风电机组为例,分别对风速为5和12 m/s、电网电压对称跌落至20%和50%工况下的LVRT运行性能进行仿真比较和样机测试。与传统LVRT控制方法的对比表明,所提改进控制策略能更好地满足风电机组LVRT的测试要求。样机测试结果进一步证明了改进控制策略和仿真模型的有效性。 展开更多
关键词 风力涡轮机 发电系统 控制策略 无功电流 分配算法 低电压 异步 双馈
下载PDF
A novel control strategy of a variable-speed doubly-fed-induction-generator-based wind energy conversion system
14
作者 Shibani Prasad Mohapatra Pradipta Kishore Dash 《Clean Energy》 EI CSCD 2024年第1期153-170,共18页
This paper aims to address the issue of control of a variable-speed wind turbine based on doubly-fed induction generators. In this work,an effort is made to extract the maximum efficiency from a doubly-fed induction g... This paper aims to address the issue of control of a variable-speed wind turbine based on doubly-fed induction generators. In this work,an effort is made to extract the maximum efficiency from a doubly-fed induction generator-based variable-speed wind turbine by controlling the rotor current. In the first step, a maximum power point tracking technique is used to extract the maximum power from theturbine. Then a stator-flux-oriented vector control strategy is employed to control the rotor-side current. Subsequently, a grid voltagevector-oriented control strategy is used to control the grid-side system of the grid-connected generator. Considering the nonlinearityand parameter uncertainty of the system, an active disturbance rejection controller with a sliding-mode-based extended-state observeris developed for the above-mentioned control strategies. Furthermore, the stability of the controller is tested and the performance of thecontroller is compared with the classical proportional-integral controller based on disturbance rejection, robustness and tracking capability in a highly non-linear wind speed variation scenario. Modelling, control and comparison are conducted in the MATLAB®/Simulink®environment. Finally, a real-time hardware set-up is presented using the dSPACE ds-1104 R&D processing board to validate the controlscheme. From the result of the experiments, it is seen that the proposed controller takes 10-15 control cycles to settle to its steady-statevalues, depending on the control loop, whereas the conventional proportional-integral controller takes 60-75 control cycles. As a result,the settling time for the proposed control scheme is shorter than that of the proportional-integral controller. 展开更多
关键词 doubly-fed induction generator variable-speed wind turbine vector control active disturbance rejection controller stability analysis
原文传递
Coordination between Fault-Ride-Through Capability and Over-current Protection of DFIG Generators for Wind Farms
15
作者 B. Bak-Jensen T.A. Kawady M.H. Abdel-Rahman 《Journal of Energy and Power Engineering》 2010年第4期20-29,共10页
Fault Ride-Through (FRT) capabilities set up according to the grid codes may affect the performance of related protective elements during fault periods. Therefore, in this paper the coordination between the FRT capa... Fault Ride-Through (FRT) capabilities set up according to the grid codes may affect the performance of related protective elements during fault periods. Therefore, in this paper the coordination between the FRT capability and over-current protection of DFIG Wind Generators in MV networks is investigated. Simulation test cases using MATLAB-Simulink are implemented on a 365-MW wind farm in AL-Zaafarana, Egypt. The simulation results show the influence of the FRT capability on the protective relaying coordination in wind farms, showing that the FRT may work in situations where is were expected not to work, and then disabling the over-current protection, which should have worked in this situation. 展开更多
关键词 Wind farms protection dynamic modeling MATLAB-SIMULINK FUSE doubly-fed induction generators
下载PDF
适应并离网模式切换的DFIG电磁暂态仿真建模
16
作者 于光耀 杨帮宇 +3 位作者 李振斌 崇志强 李惠玲 黄丽妍 《电网与清洁能源》 CSCD 北大核心 2024年第2期95-102,共8页
目前,常用的商业仿真软件中的双馈式感应发电机(double-fed Induction Generator,DFIG)模型通常不支持离网运行模式,难以实现风力发电系统由离网到并网的全过程电磁暂态仿真,对电力系统仿真分析工作带来极大不便。研究适应并离网模式切... 目前,常用的商业仿真软件中的双馈式感应发电机(double-fed Induction Generator,DFIG)模型通常不支持离网运行模式,难以实现风力发电系统由离网到并网的全过程电磁暂态仿真,对电力系统仿真分析工作带来极大不便。研究适应并离网模式切换的DFIG电磁暂态仿真建模方法。基于模块化思想分别对风力机、异步电机、变流器以及断路器进行建模,在系统组装形成DFIG风力发电系统电磁暂态仿真模型。提出了适应并离网模式切换的DFIG受控源等效电路模型和离散时间域实现方法,通过设计状态变量矩阵元素的截取和扩充算法实现了模型在并离网模式下的无缝衔接。在MATLAB/Simulink中搭建DFIG发电系统模型对所提方法和模型进行验证,仿真结果表明,所提建模方法能够很好地支持DFIG离网运行模式,实现DFIG由离网到并网的全过程电磁暂态仿真。 展开更多
关键词 双馈式感应发电机(dfig) 并离网切换 电磁暂态仿真 建模方法
下载PDF
Application of fuzzy logic control algorithm as stator power controller of a grid-connected doubly-fed induction generator 被引量:1
17
作者 Ridha CHEIKH Arezki MENACER +1 位作者 Said DRID Mourad TIAR 《Frontiers in Energy》 SCIE CSCD 2013年第1期49-55,共7页
This paper discusses the power outputs control of a grid-connected doubly-fed induction generator (DFIG) for a wind power generation systems. The DFIG structure control has a six diode rectifier and a PWM IGBT conve... This paper discusses the power outputs control of a grid-connected doubly-fed induction generator (DFIG) for a wind power generation systems. The DFIG structure control has a six diode rectifier and a PWM IGBT converter in order to control the power outputs of the DFIG driven by wind turbine. So, to supply commercially the electrical power to the grid without any problems related to power quality, the active and reactive powers (Ps, Qs) at the stator side of the DFIG are strictly controlled at a required level, which, in this paper, is realized with an optimized fuzzy logic controller based on the grid flux oriented control, which gives an optimal operation of the DFIG in sub-synchronous region, and the control of the stator power flow with the possibility of keeping stator power factor at a unity. 展开更多
关键词 doubly-fed induction generator (dfig vector control fuzzy logic controller optimization power factor unity active and reactive power
原文传递
Doubly-fed induction generator drive based WECS using fuzzy logic controller 被引量:1
18
作者 Abdelhak DIDA Djilani BEN ATTOUS 《Frontiers in Energy》 SCIE CSCD 2015年第3期272-281,共10页
The purpose of this paper is to improve the control performance of the variable speed, constant frequency doubly-fed induction generator in the wind turbine generation system by using fuzzy logic controllers. The cont... The purpose of this paper is to improve the control performance of the variable speed, constant frequency doubly-fed induction generator in the wind turbine generation system by using fuzzy logic controllers. The control of the rotor-side converter is realized by stator flux oriented control, whereas the control of the grid-side converter is performed by a control strategy based on grid voltage orientation to maintain the DC-link voltage stability. An intelligent fuzzy inference system is proposed as an alternative of the conventional proportional and integral (PI) controller to overcome any disturbance, such as fast wind speed variation, short grid voltage fault, parameter variations and so on. Five fuzzy logic controllers are used in the rotor side converter (RSC) for maximum power point tracking (MPPT) algorithm, active and reactive power control loops, and another two fuzzy logic controllers for direct and quadratic rotor currents components control loops. The performances have been tested on 1.5 MW doubly-fed induction generator (DFIG) in a Matlab/Simulink software environment. 展开更多
关键词 fuzzy logic wind turbine vector control doubly-fed induction generator (dfig
原文传递
A Long-Range Generalized Predictive Control Algorithm for a DFIG Based Wind Energy System 被引量:1
19
作者 J.S.Solis-Chaves Lucas L.Rodrigues +1 位作者 C.M.Rocha-Osorio Alfeu J.Sguarezi Filho 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2019年第5期1209-1219,共11页
This paper presents a new Long-range generalized predictive controller in the synchronous reference frame for a wind energy system doubly-fed induction generator based. This controller uses the state space equations t... This paper presents a new Long-range generalized predictive controller in the synchronous reference frame for a wind energy system doubly-fed induction generator based. This controller uses the state space equations that consider the rotor current and voltage as state and control variables, to execute the predictive control action. Therefore, the model of the plant must be transformed into two discrete transference functions, by means of an auto-regressive moving average model, in order to attain a discrete and decoupled controller, which makes it possible to treat it as two independent single-input single-output systems instead of a magnetic coupled multiple-input multiple-output system. For achieving that, a direct power control strategy is used, based on the past and future rotor currents and voltages estimation. The algorithm evaluates the rotor current predictors for a defined prediction horizon and computes the new rotor voltages that must be injected to controlling the stator active and reactive powers. To evaluate the controller performance, some simulations were made using Matlab/Simulink. Experimental tests were carried out with a small-scale prototype assuming normal operating conditions with constant and variable wind speed profiles. Finally, some conclusions respect to the dynamic performance of this new controller are summarized. 展开更多
关键词 Direct power CONTROL doubly-fed induction generator flux oriented CONTROL generalized PREDICTIVE CONTROL LONG-RANGE PREDICTIVE CONTROL wind energy systems
下载PDF
Modern Control Strategies of Doubly-Fed Induction Generator Based Wind Turbine System 被引量:2
20
作者 Dao Zhou Yipeng Song Frede Blaabjerg 《Chinese Journal of Electrical Engineering》 2016年第1期13-23,共11页
A doubly-fed induction generator(DFIG)based configuration is still preferred by wind turbine manufacturers due to the cost-effective power converter and independent control of the active power and reactive power.To co... A doubly-fed induction generator(DFIG)based configuration is still preferred by wind turbine manufacturers due to the cost-effective power converter and independent control of the active power and reactive power.To cope with stricter grid codes(e.g.reactive power compensation,low voltage ride-through operation,as well as steady and safe operation during long-term distorted grid),control strategies are continuously evolving.This paper starts with a control strategy using the combined reactive power compensation from both the back-to-back power converters for their optimized lifetime distribution under normal grid conditions.Afterwards,an advanced demagnetizing control is proposed to keep the minimum thermal stress of the rotor-side converter in the case of the short-term grid fault.A modularized control strategy of the DFIG system under unbalanced and distorted grid voltage is discussed,with the control targets of the smooth active and reactive power or the balanced and sinusoidal current of the rotor-side converter and the grid-side converte。Finally,a bandwidth based repetitive controller is evaluated to improve the DFIG system's robustness against grid frequency deviation. 展开更多
关键词 doubly-fed induction generator reactive power low voltage ride-through unbalanced and distorted grid.
原文传递
上一页 1 2 48 下一页 到第
使用帮助 返回顶部