Robust Position Observer for Sensorless Direct Voltage Control of Stand-Alone Ship Shaft Brushless Doubly-Fed Induction Generators 被引量:4
1
作者 Mohamed G.Hussien Yi Liu Wei Xu 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第4期363-376,共14页
The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position obser... The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position observer using the space vector flux relations of BDFIG may achieve the desired voltage control of the power winding(PW)in terms of magnitude and frequency,without any speed/position sensors.The proposed algorithm does not require any additional observers for obtaining the generator speed.The proposed technique can directly achieve the desired DVC based on the estimated rotor position,which may reduce the overall system cost.The stability analysis of the proposed observer is investigated and confirmed with the concept of quadratic Lyapunov function and using the multi-model representation.In addition,the sensitivity analysis of the presented method is confirmed under different issues of parameter uncertainties.Comprehensive results from both simulation and experiments are realized with a prototype wound-rotor BDFIG,which demonstrate the capability and efficacy of the proposed sensorless DVC strategy with good transient behavior under different operating conditions.Furthermore,the analysis confirms the robustness of the proposed observer via the machine parameter changes. 展开更多
关键词 Brushless doubly-fed induction generator(BDFIG) direct voltage control(DVC) PW voltage-oriented vector control rotor position observer ship shaft applications.
下载PDF
Effects of Wind Turbines Equipped with Doubly-fed Induction Generators on Distance Protection 被引量:1
2
作者 Hossein Kazemi KAREGAR Maryam KHODDAM 《电力系统自动化》 EI CSCD 北大核心 2012年第8期128-131,共4页
Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipp... Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipped with doubly-fed induction generators differ fundamentally from synchronous generators.Therefore,more considerations are needed to analyze the performances of the distance protection relays.The protection of a wind farm with distance relay is inspected.By changing the conditions of the wind farm,the characteristics of the distance relay are studied. 展开更多
关键词 距离保护 双馈异步发电机 风力发电机组 配备 可再生能源资源 双馈感应发电机 距离继电器 同步发电机
下载PDF
Analytical Model and Topology Optimization of Doubly-fed Induction Generator
3
作者 Lu Sun Haoyu Kang +4 位作者 Jin Wang Zequan Li Jianjun Liu Yiming Ma Libing Zhou 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期162-169,共8页
As the core component of energy conversion for large wind turbines,the output performance of doubly-fed induction generators (DFIGs) plays a decisive role in the power quality of wind turbines.To realize the fast and ... As the core component of energy conversion for large wind turbines,the output performance of doubly-fed induction generators (DFIGs) plays a decisive role in the power quality of wind turbines.To realize the fast and accurate design optimization of DFIGs,this paper proposes a novel hybriddriven surrogate-assisted optimization method.It firstly establishes an accurate subdomain model of DFIGs to analytically predict performance indexes.Furthermore,taking the inexpensive analytical dataset produced by the subdomain model as the source domain and the expensive finite element analysis dataset as the target domain,a high-precision surrogate model is trained in a transfer learning way and used for the subsequent multi-objective optimization process.Based on this model,taking the total harmonic distortion of electromotive force,cogging torque,and iron loss as objectives,and the slot and inner/outer diameters as parameters for optimizing the topology,achieve a rapid and accurate electromagnetic design for DFIGs.Finally,experiments are carried out on a 3MW DFIG to validate the effectiveness of the proposed method. 展开更多
关键词 doubly-fed induction generators Accurate subdomain model Surrogate-assisted Transfer learning
下载PDF
Modeling and small-signal stability analysis of doubly-fed induction generator integrated system 被引量:1
4
作者 Tianming Gu Puyu Wang +3 位作者 Dingyuan Liu Ao Sun Dejian Yang Gangui Yan 《Global Energy Interconnection》 EI CSCD 2023年第4期438-449,共12页
Owing to their stability,doubly-fed induction generator(DFIG)integrated systems have gained considerable interest and are the most widely implemented type of wind turbines and due to the increasing escalation of the w... Owing to their stability,doubly-fed induction generator(DFIG)integrated systems have gained considerable interest and are the most widely implemented type of wind turbines and due to the increasing escalation of the wind generation penetration rate in power systems.In this study,we investigate a DFIG integrated system comprising four modules:(1)a wind turbine that considers the maximum power point tracking and pitch-angle control,(2)induction generator,(3)rotor/grid-side converter with the corresponding control strategy,and(4)AC power grid.The detailed small-signal modeling of the entire system is performed by linearizing the dynamic characteristic equation at the steady-state value.Furthermore,a dichotomy method is proposed based on the maximum eigenvalue real part function to obtain the critical value of the parameters.Root-locus analysis is employed to analyze the impact of changes in the phase-locked loop,short-circuit ratio,and blade inertia on the system stability.Lastly,the accuracy of the small-signal model and the real and imaginary parts of the calculated dominant poles in the theoretical analysis are verified using PSCAD/EMTDC. 展开更多
关键词 doubly-fed induction generator(DFIG) Maximum power point tracking DICHOTOMY Small-signal stability
下载PDF
Parameter Deviation Effect Study of the Power Generation Unit on a Doubly-Fed Induction Machine-based Shipboard Propulsion System 被引量:2
5
作者 Kai Ni Yihua Hu Chun Gan 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期339-348,共10页
To lower the difficulty of fault protection,a doubly-fed induction machine based shipboard propulsion system(DFIM-SPS)that is partially power decoupled is presented.In such an intrinsically safe SPS architecture,a syn... To lower the difficulty of fault protection,a doubly-fed induction machine based shipboard propulsion system(DFIM-SPS)that is partially power decoupled is presented.In such an intrinsically safe SPS architecture,a synchronous generator(SG)is employed for power generation,and the accuracy of the parameters of power generation unit(PGU)plays an important role in SPS stable operation.In this paper,the PGU parameter deviations are studied to evaluate the effects on system performance.The models of salient-pole SG,type DC1A excitation system(EXS)and DFIM are illustrated first.Besides,the corresponding control scheme is explained.For the 16 important parameters of PGU,up to 40%of parameter deviations are applied to implement parameter sensitivity analysis.Then,simulation studies are carried out to evaluate the parameter deviation effects on system performance in detail.By defining three parameter deviation effect indicators(PDEIs),the effects on the PGU output variables,which are the terminal voltage and output active power,are studied.Moreover,the increasing rates of PDEIs with different degrees of parameter deviations for the key parameters are analyzed.Furthermore,the overall system performance is investigated for the two most influential PGU parameters.This paper provides some vital clues on SG and EXS parameter identification for DFIM-SPS. 展开更多
关键词 shipboard propulsion system partially power decoupled doubly-fed induction machine synchronous generator parameter deviation
下载PDF
A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support
6
作者 沈阳武 柯德平 +3 位作者 孙元章 Daniel Kirschen 王轶申 胡元朝 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第7期52-63,共12页
A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient volt... A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter(GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter(RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive(priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method. 展开更多
关键词 doubly-fed induction generator transient rotor current control superconducting magnetic energy storage voltage support
下载PDF
Step-Loading Characteristics of Gas Engine Cogeneration System Using Doubly-Fed Induction Generator in Stand-Alone Operation
7
作者 Tetsuji Daido Yushi Miura +1 位作者 Toshifumi Ise Yuki Sato 《Journal of Energy and Power Engineering》 2014年第3期530-542,共13页
Application of a DFIG (doubly-fed induction generator), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supp... Application of a DFIG (doubly-fed induction generator), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supply is one of important roles for the gas engine eogeneration system. In the case of conventional constant speed of synchronous generator, the amount of the allowed step load is limited to around 30% of the rated power. On the other hand, DFIG is expected to increase the amount of step load during the stand-alone operation. In this paper, it has been demonstrated that an increase in the gas engine speed resulted in an increase in the maximum amount of step load using experimental equipment with a real gas engine. It has been concluded that the proposed system can improve the performance of an emergency power supply at step-loading. 展开更多
关键词 Step load change doubly-fed induction generator gas engine cogeneration system stand-alone operation.
下载PDF
A Novel Grid Synchronization Control of Doubly-fed Induction Generator
8
作者 ZHAN Liang-yu JIN Xin-min ZHANG Lu 《电力电子技术》 CSCD 北大核心 2012年第4期38-42,共5页
The dynamic performance of doubly-fed induction generator(DFIG) before and after connection is analyzed based on corresponding mathematical models and transfer functions in decoupled vector control.The parameter tunin... The dynamic performance of doubly-fed induction generator(DFIG) before and after connection is analyzed based on corresponding mathematical models and transfer functions in decoupled vector control.The parameter tuning methods of rotor current regulator before and after connection are given.To reach same dynamic performance the parameters should take different values and be switched before and after connection.However on one hand the closing moment of stator contactor is difficult to get as the feedback signal is usually twenty millisecond delay or so.The delay in parameter switching will affect rotor current and torque dynamics during the delayed period after connection. On the other hand parameter switching is troublesome.Hence a synchronization control strategy without parameter switching is proposed and analyzed in detail,which has linear rising exciting current to avoid current overshooting. The dynamic performance of the proposed strategy is analyzed in frequency domain and implemented on a DFIG experimental platform subsequently.The proposed synchronization strategy is validated by experimental results. 展开更多
关键词 摘要 编辑部 编辑工作 读者
下载PDF
An analytic electromagnetic calculation method for performance evolution of doubly fed induction generators for wind turbines 被引量:1
9
作者 张文娟 黄守道 +1 位作者 高剑 CHEN Zhe 《Journal of Central South University》 SCIE EI CAS 2013年第10期2763-2774,共12页
An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of D... An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of DFIG, the modeling for electromagnetic calculation of DFIG was proposed. The electromagnetic calculation of DFIG was divided into three steps: the magnetic flux calculation, parameters derivation and performance checks. For each step, the detailed numeric calculation formulas were all derived. Combining the calculation formulas, the whole electromagnetic calculation procedure was established, which consisted of three iterative calculation loops, including magnetic saturation coefficient, electromotive force and total output power. All of the electromagnetic and performance data of DIFG can be calculated conveniently by the established calculation procedure, which can be used to evaluate the new designed machine. A 1.5 MW DFIG designed by the proposed procedure was built, for which the whole type tests including no-load test, load test and temperature rising test were carried out. The test results have shown that the DFIG satisfies technical requirements and the test data fit well with the calculation results which prove the correctness of the presented calculation method. 展开更多
关键词 ELECTROMAGNETIC calculation DOUBLY fed induction generator(DFIG) wind TURBINE
下载PDF
High Voltage Ride-through Control Strategy of Doubly Fed Induction Wind Generators Based on Virtual Impedance 被引量:2
10
作者 XIE Zhen ZHANG Xing YANG Shuying SONG Haihua QU Tingyu 《中国电机工程学报》 EI CSCD 北大核心 2012年第27期I0001-I0001,共1页
关键词 双馈感应发电机 风力发电机组 高电压 虚拟阻抗 控制策略 电网干扰 异步 无功补偿装置
下载PDF
Sensorless Vector Control of Induction Generators for Variable-Speed Wind Turbines Using Micro-2407
11
作者 Rabinarayana Parida Bibhu Prasad Nanda Jibanananda Mishra 《Energy and Power Engineering》 2012年第4期248-254,共7页
A sensorless vector-control strategy for an induction generator in a grid-connected wind energy conversion system is presented. The sensorless control system is based on a model reference adaptive system (MRAS) to est... A sensorless vector-control strategy for an induction generator in a grid-connected wind energy conversion system is presented. The sensorless control system is based on a model reference adaptive system (MRAS) to estimate the rotational speed. In order to tune the MRAS observer and compensate for the parameter variation and uncertainties, a separate estimation of the speed is obtained from the rotor slot harmonics using an algorithm for spectral analysis. This algorithm can track fast dynamic changes in the rotational speed, with high accuracy. Two back to back pulse width modulated (PWM) inverters are used to interface the induction generator with the grid. The front-end converter is also vector controlled. The dc link voltage is regulated using a PI fuzzy controller. The proposed sensorless control strategy has been experimentally verified on a 2.5-kW experimentally set up with an induction generator driven by a wind turbine emulator. The emulation of the wind turbine is performed using a novel strategy that allows the emulation of high-order wind turbine models, preserving all of the dynamic characteristics. The experimental results show the high level of performance obtained with the proposed sensorless vector-control method. 展开更多
关键词 Fuzzy LOGIC induction generATOR induction MOTOR DRIVES Spectral Analysis WIND Energy
下载PDF
Probabilistic Load Flow Algorithm with the Power Performance of Double-Fed Induction Generators
12
作者 CAO Ruilin XING Jie HOU Meiqian 《Journal of Donghua University(English Edition)》 CAS 2021年第3期206-213,共8页
Probabilistic load flow(PLF)algorithm has been regained attention,because the large-scale wind power integration into the grid has increased the uncertainty of the stable and safe operation of the power system.The PLF... Probabilistic load flow(PLF)algorithm has been regained attention,because the large-scale wind power integration into the grid has increased the uncertainty of the stable and safe operation of the power system.The PLF algorithm is improved with introducing the power performance of double-fed induction generators(DFIGs)for wind turbines(WTs)under the constant power factor control and the constant voltage control in this paper.Firstly,the conventional Jacobian matrix of the alternating current(AC)load flow model is modified,and the probability distributions of the active and reactive powers of the DFIGs are derived by combining the power performance of the DFIGs and the Weibull distribution of wind speed.Then,the cumulants of the state variables in power grid are obtained by improved PLF model and more accurate power probability distributions.In order to generate the probability density function(PDF)of the nodal voltage,Gram-Charlier,Edgeworth and Cornish-Fisher expansions based on the cumulants are applied.Finally,the effectiveness and accuracy of the improved PLF algorithm is demonstrated in the IEEE 14-RTS system with wind power integration,compared with the results of Monte Carlo(MC)simulation using deterministic load flow calculation. 展开更多
关键词 probabilistic load flow(PLF) cumulant method double-fed induction generator(DFIG) power performance series expansion
下载PDF
Brushless Doubly-Fed Induction Machine as a Variable Frequency Transformer
13
作者 Ayman Abdel-Khalik Ahmed Elserougi +1 位作者 Ahmed Massoud Shehab Ahmed 《Journal of Energy and Power Engineering》 2013年第1期110-117,共8页
VFT (variable frequency transformer) has been recently used as art alternative to HVDC (high voltage direct current) to control power flow between asynchronous networks. VFT consumes less reactive power than a bac... VFT (variable frequency transformer) has been recently used as art alternative to HVDC (high voltage direct current) to control power flow between asynchronous networks. VFT consumes less reactive power than a back-to-back HVDC system, provides faster initial transient recovery, and has better natural damping capability. VFT is simply a DFIM (doubly-fed induction machine) where the machine torque controls the power flow from stator to rotor and vice versa. The main disadvantage of this VFT is the slip rings and brushes required for the rotor circuit, especially in bulk power transmission. The BDFM (brushless doubly-fed machine) with nested cage rotor machine is proved to be a comparable alternative to conventional DFIM in many applications with the advantage that all windings being in the stator frame with fixed output terminals. In this paper, the BDFM is used as a BVFT (brushless variable frequency transformer). A prototype machine is designed and simulated to verify the system validity. 展开更多
关键词 Variable frequency transformer brushless doubly-fed machines AC machines induction machine.
下载PDF
OPTIMAL DESIGN OF DUAL STATOR-WINDING INDUCTION GENERATOR WITH PWM CONVERTER 被引量:2
14
作者 刘陵顺 胡育文 黄文新 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2006年第3期185-193,共9页
To minimize the reactive power of the converter of the control winding in the novel dual stator-winding induction generator based on the PWM converter, design features of the induction generator with a rectified load ... To minimize the reactive power of the converter of the control winding in the novel dual stator-winding induction generator based on the PWM converter, design features of the induction generator with a rectified load are proposed. The optimization method of excited capacitors to minimize the reactive power of the control winding at a variable speed is given. The calculation capacity of the machine with a diode bridge rectifier load is proposed. To achieve global searching, the integrated method with the improved real-coded genetic algorithm and the twodimensional finite element method (FEM) is introduced. Design results of the sample show that reactive power can be reduced by the method, and the converter capacity can be decreased to 1/3 of output rated power at the speed ratio of 1 : 3, thus reducing the volume and the mass of the inverter. 展开更多
关键词 dual stator-winding induction generator variable speed PWM converter genetic algorithm FEM optimal design
下载PDF
Steady State Analysis of a Doubly Fed Induction Generator 被引量:3
15
作者 Ahmad M. Alkandari S. A. Soliman Mansour H. Abdel-Rahman 《Energy and Power Engineering》 2011年第4期393-400,共8页
In this paper, we present the steady state analysis of a double-fed induction generator (DFIG) adopted for wind power generation. The three-phase induction machine connected to the network, to work as a generator for ... In this paper, we present the steady state analysis of a double-fed induction generator (DFIG) adopted for wind power generation. The three-phase induction machine connected to the network, to work as a generator for wind farms, is excited on the rotor circuit by a slip-frequency current injected to the rotor, from an exciter mounted on the same shaft of the machine. The resulting rotating magnetic field rotates at synchronous speed;as such the generated power has a constant frequency independent of the shaft speed. Effects of the excitation voltage magnitude and phase angle on the active and reactive power are studied, when the machine runs at constant speed. It has been shown that by controlling the excitation voltage magnitude and phase angle would control the mode of operation of the machine;motor mode or generator mode. Furthermore, the effects of the shaft speed on the active and reactive power at constant excitation voltage magnitude and constant phase angle are also investigated. 展开更多
关键词 ASYNCHRONOUS Operation Double FEED induction generATOR (DFIG) WIND Power
下载PDF
Research on Control Strategy of Grid-connected Brushless Doubly-fed Wind Power System Based on Virtual Synchronous Generator Control 被引量:5
16
作者 Shuai Liang Shi Jin Long Shi 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第4期404-412,共9页
The brushless doubly-fed wind power system based on conventional power control strategies lacks ‘inertia’ and the ability to support grid,which leads to the decline of grid stability.Therefore,a control strategy of ... The brushless doubly-fed wind power system based on conventional power control strategies lacks ‘inertia’ and the ability to support grid,which leads to the decline of grid stability.Therefore,a control strategy of brushless doubly-fed reluctance generator(BDFRG) based on virtual synchronous generator(VSG) control is proposed to solve the problem in this paper.The output characteristics of BDFRG based on VSG are similar to a synchronous generator(SG),which can support the grid frequency and increase the system ‘inertia’.According to the mathematical model of BDFRG,the inner loop voltage source control of BDFRG is derived.In addition,the specific structure and parameter selection principle of outer loop VSG control are expounded.The voltage source control inner loop of BDFRG is combined with the VSG control outer loop to establish the overall architecture of BDFRG-VSG control strategy.Finally,the effectiveness and feasibility of the proposed strategy are verified in the simulation. 展开更多
关键词 Virtual synchronous generator Brushless doubly-fed relutance generator Grid support ability Voltage source control
下载PDF
Behavior an Induction Generator without and with a Voltage Regulator 被引量:4
17
作者 M. L. Elhafyani S. Zouggar +1 位作者 M. Benkaddour A. Aziz 《Smart Grid and Renewable Energy》 2014年第9期207-219,共13页
During the isolated use of a wind system, the output voltage of the self-excited induction generator depends on the variation characteristic of its parameters: the excitation condensers, the drive speed and the load. ... During the isolated use of a wind system, the output voltage of the self-excited induction generator depends on the variation characteristic of its parameters: the excitation condensers, the drive speed and the load. Therefore, the regulation of the tension appears to be of great interest. We focused on the use of an analogical regulator of tension, with the aim of controlling the tension at the exit of the self-excited induction generator. So we modelled, implanted and simulated a wind system (Self-excited induction generator, converters (AC/DC, DC/DC) and load it) in the Orcad/Pspice environment. In the first time the behaviour of the asynchronous generator was analyzed when the load, the excitation capacitor and the drive speed vary in the absence of any form of regulation. This analysis was conducted with the aim of defining the limits of the machine exploitation. In the second time the functioning mode is controlled by an analogical control of tension. The results of simulation show the good performances of the system during the application of the proposed voltage regulator. 展开更多
关键词 WIND Power Self-Excited induction generATOR CONVERTERS (Buck-Boost) Regulation
下载PDF
PSO Based Controlled Six-phase Grid Connected Induction Generator for Wind Energy Generation 被引量:7
18
作者 Arif Iqbal Girish Kumar Singh 《CES Transactions on Electrical Machines and Systems》 CSCD 2021年第1期41-49,共9页
This paper deals a detailed performance investigation of asymmetrical six-phase grid connected induction generator(GCIG)in two proposed configurations in variable speed operation.During the system development,regulati... This paper deals a detailed performance investigation of asymmetrical six-phase grid connected induction generator(GCIG)in two proposed configurations in variable speed operation.During the system development,regulation of DC-link voltage has been proposed using particle swarm optimization(PSO)based PI controller,ensuring the power flow to utility grid through back to back converters.The closed loop operation of asymmetrical six-phase GCIG using indirect field oriented control in different configurations has been carried out in Matlab/Simulink environment.Analytical results have been verified using real time test results on virtual platform of Typhoon HIL supported with some experimental validation. 展开更多
关键词 Six-phase induction generator particle swarm optimization(PSO) indirect field oriented control
下载PDF
Reactive Current Allocation and Control Strategies Improvement of Low Voltage Ride Though for Doubly Fed Induction Wind Turbine Generation System 被引量:36
19
作者 LI Hui FU Bo +2 位作者 YANG Chao ZHAO Bin TANG Xianhu 《中国电机工程学报》 EI CSCD 北大核心 2012年第22期I0004-I0004,22,共1页
为满足风电机组低电压穿越(low voltage ride through,LVRT)的测试要求及其电气模型一致性评估需要,提出考虑向电网注入无功电流的双馈风电机组LVRT的控制策略。在阐述风电机组LVRT测试要求及控制原理的基础上,推导双馈发电机(doubly... 为满足风电机组低电压穿越(low voltage ride through,LVRT)的测试要求及其电气模型一致性评估需要,提出考虑向电网注入无功电流的双馈风电机组LVRT的控制策略。在阐述风电机组LVRT测试要求及控制原理的基础上,推导双馈发电机(doubly fed induction generator,DFIG)定子侧及网侧变流器输出无功电流极限表达式,研究电网电压跌落深度和发电机总输出有功功率对其无功电流极限值的影响规律,进而提出DFIG在LVRT期间的无功电流分配算法和改进的有功、无功功率控制策略。最后,以某实际2 MW双馈风电机组为例,分别对风速为5和12 m/s、电网电压对称跌落至20%和50%工况下的LVRT运行性能进行仿真比较和样机测试。与传统LVRT控制方法的对比表明,所提改进控制策略能更好地满足风电机组LVRT的测试要求。样机测试结果进一步证明了改进控制策略和仿真模型的有效性。 展开更多
关键词 风力涡轮机 发电系统 控制策略 无功电流 分配算法 低电压 异步 双馈
下载PDF
Isolated MicroGrid’s Voltage and Frequency Characteristic with Induction Generator Based Wind Turbine 被引量:1
20
作者 Woo-Kyu Chae Hak-Ju Lee +2 位作者 Sung-Wook Hwang Il-Keun Song Jae-Eon Kim 《Smart Grid and Renewable Energy》 2014年第7期180-192,共13页
To save on the island area's power supply cost and protect the clean environment, the Isolated MicroGrid is being duly considered. Consisting of the Wind Turbine Generator (WT), photovoltaic generator, battery sys... To save on the island area's power supply cost and protect the clean environment, the Isolated MicroGrid is being duly considered. Consisting of the Wind Turbine Generator (WT), photovoltaic generator, battery system, back-up diesel generator, etc., Isolated MicroGrid, which usually uses the inverter to maintain voltage and frequency of the system, is very weak in terms of voltage and frequency stability compared to the large-scale electrical power system. If wind turbine generator is applied to this weak power system, it could experience many problems in terms of maintaining its voltage and frequency. In this paper, the measurement result of voltage and frequency is presented for MicroGrid, which consists of the Wind Turbine Generator adopting the induction generator and the battery system. MicroGrid’s voltage waveform distortion and Wind Turbine Generator’s output oscillation problems are analyzed using PSCAD/EMTDC. Based on the analyzed result, the importance of type and capacity choice has been suggested in case the Wind Turbine Generator is applied to the Isolated MicroGrid. 展开更多
关键词 MICROGRID Wind TURBINE induction generator Battery VOLTAGE Frequency PSCAD/EMTDC