BACKGROUND Intracranial arterial narrowing is a significant factor leading to brief episodes of reduced blood flow to the brain,known as transient ischemic attacks,or fullblown strokes.While atherosclerosis is commonl...BACKGROUND Intracranial arterial narrowing is a significant factor leading to brief episodes of reduced blood flow to the brain,known as transient ischemic attacks,or fullblown strokes.While atherosclerosis is commonly associated with intracranial arterial narrowing,it is frequently of a non-atherosclerotic nature in younger patients.CASE SUMMARY Here,we present the case of a young stroke patient with narrowing of the middle cerebral artery(MCA),characterized as non-atherosclerotic lesions,who experienced an ischemic stroke despite receiving standard drug therapy.The patient underwent digital subtraction angiography(DSA)to assess the entire network of blood vessels in the brain,revealing significant narrowing(approximately 80%)in the M1 segment of the right MCA.Subsequently,the patient underwent Drug-Coated Balloon Angioplasty to treat the stenosis in the right MCA's M1 segment.Follow-up DSA confirmed the resolution of stenosis in this segment.Although the remaining branches showed satisfactory blood flow,the vessel wall exhibited irregularities.A review of DSA conducted six months later showed no evident stenosis in the right MCA,with a smooth vessel wall.CONCLUSION The use of drug-coated balloon angioplasty demonstrated favorable outcomes in repairing and reshaping the blood vessel wall in young patients.Therefore,it may be considered a promising treatment option for similar cases.展开更多
The incidence of acute myocardial infarction (AMI) is increasing year by year, which seriously endangers human health around the world. The preferred treatment strategy for AMI patients is the use of drug-eluting sten...The incidence of acute myocardial infarction (AMI) is increasing year by year, which seriously endangers human health around the world. The preferred treatment strategy for AMI patients is the use of drug-eluting stents (DES), as there is ample evidence to suggest that stent implantation can reduce major adverse cardiovascular events (MACEs). With the application of drug-coated balloons (DCBs) and the enhancement of the concept of interventional without implantation, the question is whether DCBs can be safely and effectively used in patients with AMI? The purpose of this study was to investigate the safety and effectiveness of DCBs in the treatment of AMI. A retrospective review of clinical data was conducted on 55 AMI patients who underwent primary percutaneous coronary intervention (PCI) from January 2020 to December 2021. Of these patients, 25 were treated with DCBs and 30 were treated with DESs. Optical coherence tomography (OCT) was used to measure the minimum lumen diameter, lumen stenosis, and coronary artery dissection before and after surgery, and angina pectoris attacks and various MACEs were recorded at 1, 6, and 12 months after surgery. The results showed that there were no significant differences in clinical baseline data between the two groups. However, the minimum lumen diameter of the DCB group immediately after the operation was smaller than that of the DES group, and the stenosis degree of the lumen in the DCB group was higher than that in the DES group. The incidence of coronary artery dissection in the DCB group was significantly higher than that in the DES group, but the majority of them were type B. At 1, 6, and 12 months after treatment, there was no significant difference in the occurrence of MACEs between the two groups. In conclusion, DCBs is a safe and effective treatment for AMI. However, the incidence of coronary artery dissection in DCB patients is higher than that in DES patients, but the majority of them are type B. .展开更多
Background:Previous single-center studies have demonstrated that drug-coated balloons(DCBs)may reduce restenosis rates,which is an important factor affecting the prognosis for intracranial interventional therapy.Howev...Background:Previous single-center studies have demonstrated that drug-coated balloons(DCBs)may reduce restenosis rates,which is an important factor affecting the prognosis for intracranial interventional therapy.However,currently available cardiac DCBs are not always suitable for the treatment of intracranial atherosclerotic stenosis(ICAS).This study aimed to evaluate the safety and efficacy of a novel DCB catheter designed for patients with severely symptomatic ICAS.Methods:This prospective,multicenter,single-arm,target-value clinical trial was conducted in 9 Chinese stroke centers to evaluate the safety and efficacy of a novel DCB catheter for treating symptomatic severe ICAS.Primary metrics and other indicators were collected and analyzed using SAS version 9.4(SAS Institute,Cary,NC,USA).Results:A total of 155 patients were enrolled in this study.The preliminary collection of follow-up data has been completed,while data quality control is ongoing.Conclusion:Results of this study demonstrated the patency rate,safety,and effectiveness of a novel on-label paclitaxel DCB designed for the treatment of ICAS.Ethics and dissemination:This study,involving human participants,was reviewed and approved by the Ethics Committee of Drugs(Devices)Clinical Experiment at Henan Provincial People’s Hospital(reference number:2020-145-03)and other research centers participating in the clinical trial.The results of this study will be presented at international conferences and sent to peer-reviewed journals for publication.Standard protocol items:The Recommendations for Interventional Trials checklist was used when drafting the study protocol.Trial registration number:Registered with the Chinese Clinical Trial Registry on June 11,2021(Chi CTR2100047223).展开更多
BACKGROUND Percutaneous transluminal coronary angioplasty,while an effective intervention,can frequently lead to acute occlusion with severe consequences.Although clinical trials have demonstrated the efficacy of drug...BACKGROUND Percutaneous transluminal coronary angioplasty,while an effective intervention,can frequently lead to acute occlusion with severe consequences.Although clinical trials have demonstrated the efficacy of drug-coated balloons(DCB)in treating acute coronary artery occlusion and in preventing restenosis,there has been limited exploration on the use of DCB in treating de novo lesions in large vessels.Currently,DCB are only recommended for patients with small vessel lesions and in-stent restenosis lesions,those at high risk of bleeding,and other special groups of patients.CASE SUMMARY This report presents a case of successful drug-coated balloon treatment of de novo lesions in large coronary vessels.Postoperatively,the patient demonstrated favorable recovery,with subsequent examination results revealing no significant differences from the previous examination.CONCLUSION The successful treatment of the patient in our case highlights the potential of DCB in the treatment of de novo lesions in large coronary vessels.展开更多
BACKGROUND Controversy exists as to the optimal treatment approach for ostial left anterior descending(LAD)or ostial left circumflex artery(LCx)lesions.Drug-coated balloons(DCB)may overcome some of the limitations of ...BACKGROUND Controversy exists as to the optimal treatment approach for ostial left anterior descending(LAD)or ostial left circumflex artery(LCx)lesions.Drug-coated balloons(DCB)may overcome some of the limitations of drug-eluting stents(DES).Therefore,we investigated the security and feasibility of the DCB policy in patients with ostial LAD or ostial LCx lesions,and compared it with the conventional DES-only strategy.METHODS We retrospectively enrolled patients with de novo ostial lesions in the LAD or LCx who underwent interventional treatment.They were categorized into two groups based on their treatment approach:the DCB group and the DES group.The treatment strategies in the DCB group involved the use of either DCB-only or hybrid strategies,whereas the DES group utilized crossover or precise stenting techniques.Two-year target lesion revascularization was the primary endpoint,while the rates of major adverse cardiovascular events,cardiac death,target vessel myocardial infarction,and vessel thrombosis were the secondary endpoints.Using propensity score matching,we assembled a cohort with comparable baseline characteristics.To ensure result analysis reliability,we conducted sensitivity analyses,including interaction,and stratified analyses.RESULTS Among the 397 eligible patients,6.25%of patients who were planned to undergo DCB underwent DES.A total of 108 patients in each group had comparable propensity scores and were included in the analysis.Two-year target lesion revascularization occurred in 5 patients(4.90%)and 16 patients(16.33%)in the DCB group and the DES group,respectively(odds ratio=0.264,95%CI:0.093–0.752,P=0.008).Compared with the DES group,the DCB group demonstrated a lower major adverse cardiovascular events rate(7.84%vs.19.39%,P=0.017).However,differences with regard to cardiac death,non-periprocedural target vessel myocardial infarction,and definite or probable vessel thrombosis between the groups were non-significant.CONCLUSIONS The utilization of the DCB approach signifies an innovative and discretionary strategy for managing isolated ostial lesions in the LAD or LCx.Nevertheless,a future randomized trial investigating the feasibility and safety of DCB compared to the DES-only strategy specifically for de novo ostial lesions in the LAD or LCx is highly warranted.展开更多
In recent decades, the outcomes of coronary heart disease (CHD) have markedly improved, which can be partly attributed to the use of novel drugs (especially statins and antiplatelet drugs) and partly to the evolut...In recent decades, the outcomes of coronary heart disease (CHD) have markedly improved, which can be partly attributed to the use of novel drugs (especially statins and antiplatelet drugs) and partly to the evolution ofpercutaneous coronary intervention (PCI). From percutaneous transluminal coronary angioplasty to bare-metal stent and then to drug-eluting stent, every step of PCI is attractive to interventional cardiologist, great progress has been made for patients with CHD. In the past few years, some successor devices for treating CHD have cmerged. Undoubtedly, drug-coated balloon (DCB), which was recommended by 2014 ESC Guidelines on myocardial revascularization, is a "shining star" among them. DCB involves a semi-compliant angioplasty balloon coated with an anti-proliferative agent that can exert antirestenotic efficacy by permeating into the vessel wall during balloon contact. This review discusses the conception and merits, preclinical data, emerging clinical indications, and results from clinical trials of this novel interventional technology. Although DCB has shown authentic efficacy in the treatment ofin-stent restenosis, its use in de novo coronary lesions is still in dispute. Hence, concerns and the future direction of DCB are also covered in this paper.展开更多
BACKGROUND The in-stent restenosis(ISR)rates are reportedly inconsistent despite the increased use of second-generation drug eluting stent(DES).Although bioresorbable vascular scaffold(BVS)have substantial advantages ...BACKGROUND The in-stent restenosis(ISR)rates are reportedly inconsistent despite the increased use of second-generation drug eluting stent(DES).Although bioresorbable vascular scaffold(BVS)have substantial advantages with respect to vascular restoration,the rate of scaffold thrombosis is higher with BVS than with DES.Optimal treatment strategies have not been established for DES-ISR to date.CASE SUMMARY We report on a case of a 60-year-old man patient with acute coronary syndrome.He had a history of ST-segment elevation myocardial infarction associated with very late scaffold thrombosis and treated with a DES.Coronary angiography revealed significant stenosis,suggesting DES-ISR on the previous BVS.Optical coherence tomography(OCT)identified a plaque rupture and a disrupted scaffold strut in the neointimal proliferation of DES.To treat the DES-ISR on the previous BVS,we opted for a drug-coated balloon(DCB)after a balloon angioplasty using a semi-compliant and non-compliant balloon.The patient did not experience adverse cardiovascular events on using a DCB following the use of intensive dual antiplatelet therapy and statin for 24 mo.CONCLUSION This case highlights the importance of OCT as an imaging modality for characterizing the mechanism of target lesion failure.The use of a DCB following the administration of optimal pharmacologic therapy may be an optimal strategy for the treatment and prevention of recurrent BVS thrombosis and DES-ISR.展开更多
Objective:To evaluate the clinical efficacy of a drug-eluting stent(DES)combined with a drug-coated balloon(DCB)in the treatment of left main coronary artery bifurcation lesions.Methods:A retrospective analysis was co...Objective:To evaluate the clinical efficacy of a drug-eluting stent(DES)combined with a drug-coated balloon(DCB)in the treatment of left main coronary artery bifurcation lesions.Methods:A retrospective analysis was conducted on the clinical data of eight patients with left main coronary artery bifurcation lesions treated with a DES combined with a DCB who were admitted to our hospital from July 2016 to July 2017.These eight patients all underwent DES treatment for their left main coronary artery and left anterior descending coronary artery lesions,and DCB treatment at the ostium of the left circumflex artery;six of the patients underwent surgical procedures under the guidance of intravascular ultrasonography.Immediate postoperative angiography was used to evaluate the patency of the diseased vessels,and the restenosis rate at the 6-month follow-up after the operation and the incidence of serious clinical events within 6 months were assessed as well.Results:The use of a DES combined with a DCB in the treatment of left main coronary artery bifurcation lesions had a low restenosis rate(left main coronary artery(8.4±5.3)%,left anterior descending coronary artery(18.2±5.0)%,left circumflex artery(30.5±16.5)%).No serious clinical events occurred in any patients.Conclusion:A DES combined with a DCB is a safe and effective interventional treatment for left main artery coro-nary bifurcation lesions.展开更多
We evaluated the clinical feasibility of using drugcoated balloon(DCB) angioplasty in patients undergoingprimary percutaneous coronary intervention(PPCI). Between January 2010 to September 2014,89 STelevation myocardi...We evaluated the clinical feasibility of using drugcoated balloon(DCB) angioplasty in patients undergoingprimary percutaneous coronary intervention(PPCI). Between January 2010 to September 2014,89 STelevation myocardial infarction patients(83% male,mean age 59 ± 14 years) with a total of 89 coronary lesions were treated with DCB during PPCI. Clinical outcomes are reported at 30 d follow-up. Left anterior descending artery was the most common target vessel for PCI(37%). Twenty-eight percent of the patients had underlying diabetes mellitus. Mean left ventricular ejection fraction was 44% ± 11%. DCB-only PCI was the predominant approach(96%) with the remaining 4% of patients receiving bail-out stenting. Thrombolysis in Myocardial Infarction(TIMI) 3 flow was successfully restored in 98% of patients. An average of 1.2 ± 0.5 DCB were used per patient,with mean DCB diameter of 2.6 ± 0.5 mm and average length of 23.2 ± 10.2 mm. At 30-d follow-up,there were 4 deaths(4.5%). No patients experienced abrupt closure of the infarctrelated artery and there was no reported target-lesion failure. Our preliminary experience showed that DCB angioplasty in PPCI was feasible and associated with a high rate of TIMI 3 flow and low 30-d ischaemic event.展开更多
Objective:The aim of this study was to compare the efficacy,safety and treatment costs of superficial femoral artery revascularization(SFA)with drug-coated balloon(DCB)versus avoiding revascularization strategy for th...Objective:The aim of this study was to compare the efficacy,safety and treatment costs of superficial femoral artery revascularization(SFA)with drug-coated balloon(DCB)versus avoiding revascularization strategy for the treatment of symptomatic SFA disease.Methods:This retrospective single-center study reviewed 96 patients(113 limbs)with severe stenosis and occlusive SFA disease.All patients underwent either DCB(Group 1:n=55 limbs)or nonrevascularization(Group2:n=58 limbs)between March 2015 and June 2019.The improvement of Rutherford class,walking impairment questionnaire score(WIQ),target limb reintervention,perioperative major adverse events,the catheterization laboratory cost and length of hospital stay were compared.The limb salvage and survival rates were calculated using the Kaplan-Meier method.Univariate and multivariate logistic regression analysis were performed to assess the association between factors and the improvement of Rutherford category at 12 months.Results:The median follow-up time of Groups 1 and 2 was 17 and 33 months,respectively.At 12 months,the Rutherford category significantly decreased in both groups(P<0.001),with no significant difference(79.7%vs.64.3%,P=0.074).Furthermore,multivariate analysis showed that the selected therapeutic method was not an influential factor for the improvement of Rutherford class at 12 months.The WIQ overall score as well as three subscales scores(distance,speed and stair-climbing),the survival rate,limb salvage rate and the length of stay between the two groups were comparable.The perioperative adverse events rate and catheterization laboratory cost in Group 2 was significantly lower compared to Group 1[(34253.69±28172.87)yuan vs.(56936.76±41278.36)yuan,P=0.001].Conclusions:This study suggests that avoiding superficial femoral artery revascularization strategy has favorable efficacy and safety outcomes compared to combining revascularization with DCB in selected patients.展开更多
This retrospective single-center registry study included all consecutive patients who underwent percutaneous coronary intervention (PCI) for a de novo left main coronary artery lesion using drug coated-balloon (DCB)-o...This retrospective single-center registry study included all consecutive patients who underwent percutaneous coronary intervention (PCI) for a de novo left main coronary artery lesion using drug coated-balloon (DCB)-only strategy between August 2011 and December 2018. To best of our knowledge, no previous studies of DCB-only strategy of treating de novo left main coronary artery disease, exist. The primary endpoint was major adverse cardiovascular events (MACEs) including cardiac death, non-fatal myocardial infarction, and target lesion revascularization (TLR). The cohort was divided into two groups depending on weather the lesion preparation was done according to the international consensus group guidelines. Sixty-six patients (mean age 75±8.6, 72% male), 52% of whom had acute coronary syndrome, underwent left main PCI with the DCB-only strategy. No procedural mortality and no acute closures of the treated left main occurred. At 12 months, MACE and TLR occurred in 24% and 6% of the whole cohort, respectively. If the lesion preparation was done according to the guidelines, the MACE and TLR rates were 21.2% and 1.9%. Left main PCI with the DCB only-strategy is safe leading to acceptable MACE and low TLR rates at one year, if the lesion preparation is done according to the guidelines.展开更多
Background:Drug-coated balloons(DCBs)have emerged as potential alternatives to drug-eluting stents in specific lesion subsets for de novo coronary lesions.Quantitative flow ratio(QFR)is a method based on the three-dim...Background:Drug-coated balloons(DCBs)have emerged as potential alternatives to drug-eluting stents in specific lesion subsets for de novo coronary lesions.Quantitative flow ratio(QFR)is a method based on the three-dimensional quantitative coronary angiography and contrast flow velocity during coronary angiography(CAG),obviating the need for an invasive fractional flow reserve procedural.This study aimed to assess the serial angiographic changes of de novo lesions post-DCB therapy and further explore the cut-off values of lesion and vessel QFR,which predict vessel restenosis(diameter stenosis[DS]≥50%)at mid-term follow-up.Methods:The data of patients who underwent DCB therapy between January 2014 and December 2019 from the multicenter hospital were retrospectively collected for QFR analysis.From their QFR performances,which were analyzed by CAG images at follow-up,we divided them into two groups:group A,showing target vessel DS≥50%,and group B,showing target vessel DS<50%.The median follow-up time was 287 days in group A and 227 days in group B.We compared the clinical characteristics,parameters during DCB therapy,and QFR performances,which were analyzed by CAG images between the two groups,in need to explore the cut-off value of lesion/vessel QFR which can predict vessel restenosis.Student's t test was used for the comparison of normally distributed continuous data,Mann-Whitney U test for the comparison of non-normally distributed continuous data,and receiver operating characteristic(ROC)curves for the evaluation of QFR performance which can predict vessel restenosis(DS≥50%)at mid-term follow-up using the area under the curve(AUC).Results:A total of 112 patients with 112 target vessels were enrolled in this study.Group A had 41 patients,while group B had 71.Vessel QFR and lesion QFR were lower in group A than in group B post-DCB therapy,and the cut-off values of lesion QFR and vessel QFR in the ROC analysis to predict target vessel DS≥50%post-DCB therapy were 0.905(AUC,0.741[95%confidence interval,CI:0.645,0.837];sensitivity,0.817;specificity,0.561;P<0.001)and 0.890(AUC,0.796[95%CI:0.709,0.882];sensitivity,0.746;specificity,0.780;P<0.001).Conclusions:The cut-off values of lesion QFR and vessel QFR can assist in predicting the angiographic changes post-DCB therapy.When lesion/vessel QFR values are<0.905/0.890 post-DCB therapy,a higher risk of vessel restenosis is potentially predicted at follow-up.展开更多
Background:Drug-coated balloons(DCBs)are an up-and-coming tactic in treating in-stent restenosis and coronary artery small vessel disease,but their efficacy in treating acute myocardial infarction needs to be further ...Background:Drug-coated balloons(DCBs)are an up-and-coming tactic in treating in-stent restenosis and coronary artery small vessel disease,but their efficacy in treating acute myocardial infarction needs to be further explored.Methods:A meta-analysis of 7 studies was conducted to make a comparison with the results of DCB and drug-eluting stent implantation after a median follow-up of 15 months.Results:A total of 922 patients were included in this analysis in total,including 375 patients in the DCB group and 547 patients in the stent group.A total of 962 vascular diseases were manifested in the 2 groups.After 6 to 24 months of follow-up,there was no statistically significant difference with respect to major adverse cardiovascular events(odds ratio[OR]:0.82;95%confidence interval[CI]:0.52–1.29;Z=0.85;P=0.39),cardiac death(OR:0.92;95%CI:0.39–2.12;Z=0.21;P=0.84),target lesion revascularization(OR:1.09;95%CI:0.53–2.25;Z=0.24;P=0.81),late lumen loss(MD:−0.05;95%CI:−0.15 to 0.06;Z=0.85;P=0.40),or dual antiplatelet therapy(DAPT)(OR:1.04;95%CI:0.53–2.05;Z=0.11;P=0.91)between the 2 groups.In the DCB group,persistent residual stenosis or C-F dissection occurrence necessitated that a total of 30 patients receive extra bailout implantations.The rate of bailout stenting was 11.8%(95%CI:7.1–16).Moreover,the DCB group had a shorter DAPT duration compared with the stent group.Conclusion:Drug-coated balloons with shorter DAPT durations may be as effective and safe as stent therapy in treating acute myocardial infarction.展开更多
Percutaneous coronary interventions have progressed through the era of plain balloon dilation, bare-metal stent insertion to drug-eluting stent treatment, which has significantly reduced the acute occlusion and resten...Percutaneous coronary interventions have progressed through the era of plain balloon dilation, bare-metal stent insertion to drug-eluting stent treatment, which has significantly reduced the acute occlusion and restenosis rates of target vessels and improved patient prognosis, making drug-eluting stents the mainstream interventional treatment for coronary artery disease. In recent years, drug-coated balloons(DCBs) have become a new treatment strategy for coronary artery disease, and the drugs used in the coating and the coating technology have progressed in the past years. Without permanent implant, a DCB delivers antiproliferative drugs rapidly and uniformly into the vessel wall via the excipient during a single balloon dilation. Many evidence suggests that DCB angioplasty is an effective measure for dealing with in-stent restenosis and de novo lesions in small coronary vessels.As more clinical studies are published, new evidence is emerging for the use of DCB angioplasty in a wide range of coronary diseases, and the indications are expanding internationally. Based on the latest research from China and elsewhere, the Expert Writing Committee of the Chinese Expert Consensus on Clinical Applications of Drug-Coated Balloon has updated the previous DCB consensus after evidence-based discussions and meetings in terms of adequate preparation of in-stent restenosis lesions, expansion of the indications for coronary de novo lesions, and precise guidance of DCB treatment by intravascular imaging and functional evaluation.展开更多
Aortic stenosis(AS)stands out as the most prevalent individual valvular defect globally.The onset and progression of AS mirror an active process akin to atherosclerosis,and the traditional triad of symptoms includes c...Aortic stenosis(AS)stands out as the most prevalent individual valvular defect globally.The onset and progression of AS mirror an active process akin to atherosclerosis,and the traditional triad of symptoms includes chest pain,breathlessness,and loss of consciousness.Prognosis takes a significant downturn when symptoms manifest,with mortality reaching approximately 50%-85% within the subsequent 5 years after symptom onset.展开更多
The X-ray sources of the universe are extraterrestrial in nature which emit X-ray photons.The closest strong X-ray source is the Sun,which is followed by various compact sources such as neutron stars,black holes,the C...The X-ray sources of the universe are extraterrestrial in nature which emit X-ray photons.The closest strong X-ray source is the Sun,which is followed by various compact sources such as neutron stars,black holes,the Crab pulsar,etc.In this paper,we analyze the data received from several low-cost lightweight meteorological balloon-borne missions launched by the Indian Centre for Space Physics.Our main interest is to study the variation of the vertical intensity of secondary cosmic rays,the detection of strong X-ray sources,and their spectra in the energy band of^(1)0–80 keV during the complete flights.Due to the lack of an onboard pointing system,low exposure time,achieving a maximum altitude of only~42 km,and freely rotating the payload about its axis,we modeled the background radiation flux for the X-ray detector using physical assumptions.We also present the source detection method,observation of the pulsation of the Crab(^(3)3 Hz),and spectra of some sources such as the quiet Sun and the Crab pulsar.展开更多
Objective:To prospectively follow up a cohort of anterior urethral stricture disease patients managed with balloon dilation(BD)for 3 years to evaluate the long-term outcomes and to study factors that contribute to rec...Objective:To prospectively follow up a cohort of anterior urethral stricture disease patients managed with balloon dilation(BD)for 3 years to evaluate the long-term outcomes and to study factors that contribute to recurrence.Methods:This study included men who had urethral BD for significant anterior urethral stricture disease between January 2017 and March 2019.Data about the patient age,stricture characteristics,and recurrence date were recorded,along with information on postoperative indwelling catheter use and operative complications.Furthermore,information about the self-calibration procedure was collected and where available,free flow(FF)measurements during the follow-up period were recorded and analyzed.Success was defined as a lack of symptoms and acceptable FF rates(maximum flow rate>12 mL/s).Results:The final analysis was conducted on 187 patients.The mean follow-up period was 37 months.The long-term overall success rate at the end of our study was 66.8%.Our recurrence rate was 7.4%at 12 months,24.7%at 24 months,and reached 33.2%at the end of our study.The time to recurrence ranged from 91 days to 1635 days,with a mean of 670 days.The stricture-free survival was significantly shorter with lengthy peno-bulbar(p=0.031)and multiple strictures(p=0.015),and in the group of patients who were not committed to self-calibration protocol(p<0.011).However,post-procedural self-calibration was the most important factor that may have decreased the incidence of recurrence(odds ratioZ5.85).Adjuvant self-calibration after BD not only reduced the recurrence rate from 85.4%in the non-self-calibration group to 15.1%in the self-calibration one(p<0.001),but also improved the overall stricture-free survival and FF parameters.展开更多
BACKGROUND:Resuscitative endovascular balloon occlusion of the aorta(REBOA)can temporarily control traumatic bleeding.However,its prolonged use potentially leads to ischemia-reperfusion injury(IRI).Partial REBOA(pREBO...BACKGROUND:Resuscitative endovascular balloon occlusion of the aorta(REBOA)can temporarily control traumatic bleeding.However,its prolonged use potentially leads to ischemia-reperfusion injury(IRI).Partial REBOA(pREBOA)can alleviate ischemic burden;however,its security and eff ectiveness prior to operative hemorrhage control remains unknown.Hence,we aimed to estimate the effi cacy of pREBOA in a swine model of liver injury using an experimental sliding-chamber ballistic gun.METHODS:Twenty Landrace pigs were randomized into control(no aortic occlusion)(n=5),intervention with complete REBOA(cREBOA)(n=5),continuous pREBOA(C-pREBOA)(n=5),and sequential pREBOA(S-pREBOA)(n=5)groups.In the cREBOA and C-pREBOA groups,the balloon was inflated for 60 min.The hemodynamic and laboratory values were compared at various observation time points.Tissue samples immediately after animal euthanasia from the myocardium,liver,kidneys,and duodenum were collected for histological assessment using hematoxylin and eosin staining.RESULTS:Compared with the control group,the survival rate of the REBOA groups was prominently improved(all P<0.05).The total volume of blood loss was markedly lower in the cREBOA group(493.14±127.31 mL)compared with other groups(P<0.01).The pH was significantly lower at 180 min in the cREBOA and S-pREBOA groups(P<0.05).At 120 min,the S-pREBOA group showed higher alanine aminotransferase(P<0.05)but lower blood urea nitrogen compared with the cREBOA group(P<0.05).CONCLUSION:In this trauma model with liver injury,a 60-minute pREBOA resulted in improved survival rate and was effective in maintaining reliable aortic pressure,despite persistent hemorrhage.Extended tolerance time for aortic occlusion in Zone I for non-compressible torso hemorrhage was feasible with both continuous partial and sequential partial measures,and the significant improvement in the severity of acidosis and distal organ injury was observed in the sequential pREBOA.展开更多
BACKGROUND Over one-third of Americans carry the diagnosis of obesity,many also with obesity-related comorbidities.This can place patients at increased risk of operative and postoperative complications.The intragastri...BACKGROUND Over one-third of Americans carry the diagnosis of obesity,many also with obesity-related comorbidities.This can place patients at increased risk of operative and postoperative complications.The intragastric balloon has been shown to aid in minor weight loss,however its weight recidivism in patients requiring short interval weight loss has not been well studied.AIM To evaluate weight loss,ability to undergo successful elective surgery after intragastric balloon placement,and weight management after balloon removal.METHODS This study is a retrospective review of patients in a single academic institution undergoing intragastric balloon placement from 2019-2023 to aid in weight loss prior to undergoing elective surgery.Clinical outcomes including weight loss,duration of balloon placement,successful elective surgery,weight regain postballoon and post-procedure complications were assessed.Exclusion criteria included those with balloon in place at time of study.RESULTS Thirty-three patients completed intragastric balloon therapy from 2019-2023 as a bridge to elective surgery.All patients were required to participate in a 12-month weight management program to be eligible for balloon therapy.Elective surgeries included incisional hernia repair,umbilical hernia repair,inguinal hernia repair,and knee and hip replacements.The average age at placement was 53 years±11 years,majority(91%)were male.The average duration of intragastric balloon therapy was 186 days±41 days.The average weight loss was 14.0 kg±7.4 kg and with an average percent excess body weight loss of 30.0%(7.9%-73.6%).Over half of the patients(52.0%)achieved the goal of 30-50 lbs(14-22 kg)weight loss.Twenty-one patients(64%)underwent their intended elective surgery,2 patients(6%)deferred surgery due to symptom relief with weight loss alone.Twenty-one of the patients(64%)have documented weights in 3 months after balloon removal,in these patients the majority(76%)gained weight after balloon removed.In patients with weight regain at 3 months,they averaged 5.8 kg after balloon removal in the first 3 months,this averaged 58.4%weight regain of the initial weight lost.CONCLUSION Intragastric balloon placement is an option for short-term weight management,as a bridge to elective surgery in patients with body mass index(BMI)>35.Patients lost an average of 14 kg with the balloon,allowing two-thirds of patients to undergo elective surgery at a healthy BMI.However,most patients regained an average of 58%of the original weight lost after balloon removal.The intragastric balloon successfully serves as a tool for rapid weight loss,though patients must be educated on the risks including weight regain.展开更多
BACKGROUND Endoscopic retrograde cholangiopancreatography(ERCP),with its clinical ad-vantages of less trauma and faster recovery,has become the primary treatment for choledocholithiasis.AIM To investigate the effects ...BACKGROUND Endoscopic retrograde cholangiopancreatography(ERCP),with its clinical ad-vantages of less trauma and faster recovery,has become the primary treatment for choledocholithiasis.AIM To investigate the effects of different ERCP procedures on the sphincter of Oddi.METHODS The clinical data of 91 patients who underwent ERCP at Yixing Hospital of Traditional Chinese Medicine between February 2018 and February 2021 were analyzed retrospectively.The patients were divided into endoscopic sphinc-terotomy(EST,n=24)and endoscopic papillary balloon dilation(EPBD,n=67)groups.The duration of operation,pancreatic development,pancreatic sphinc-terotomy,intubation difficulties,stone recurrence,and incidence of reflux cho-langitis and cholecystitis were statistically analyzed in patients with a history of choledocholithiasis,pancreatitis,and Oddi sphincter dysfunction in the EST and EPBD groups.RESULTS Differences in hypertension,diabetes,increased bilirubin,small diameter of the common bile duct,or ampullary diverticulum between the two groups were not significant.Statistically significant differences were observed between the two groups concerning sex and age(<60 years).Patients with a history of choledocholithiasis,pancreatitis,and Oddi sphincter dysfunction were higher in the EST group than in the EPBD group.The number of cases of pancreatic development,pancreatic duct sphincterotomy,and difficult intubation were higher in the EST group than in the EPBD group.The number of Oddi’s sphincter manometries,ERCP surgical outcomes,and guidewires entering the pancreatic duct several times in EST group were lower than those in the EPBD group.The numbers of stone recurrences,reflux cholangitis,and cholecystitis were higher in the EST group than in the EPBD group.CONCLUSION In summary,common bile duct stones,pancreatitis history,and multiple guided wire introductions into the pancreatic duct are independent risk factors for EST and EPBD.Based on this evidence,this study can provide actionable insights for clinicians and researchers.展开更多
文摘BACKGROUND Intracranial arterial narrowing is a significant factor leading to brief episodes of reduced blood flow to the brain,known as transient ischemic attacks,or fullblown strokes.While atherosclerosis is commonly associated with intracranial arterial narrowing,it is frequently of a non-atherosclerotic nature in younger patients.CASE SUMMARY Here,we present the case of a young stroke patient with narrowing of the middle cerebral artery(MCA),characterized as non-atherosclerotic lesions,who experienced an ischemic stroke despite receiving standard drug therapy.The patient underwent digital subtraction angiography(DSA)to assess the entire network of blood vessels in the brain,revealing significant narrowing(approximately 80%)in the M1 segment of the right MCA.Subsequently,the patient underwent Drug-Coated Balloon Angioplasty to treat the stenosis in the right MCA's M1 segment.Follow-up DSA confirmed the resolution of stenosis in this segment.Although the remaining branches showed satisfactory blood flow,the vessel wall exhibited irregularities.A review of DSA conducted six months later showed no evident stenosis in the right MCA,with a smooth vessel wall.CONCLUSION The use of drug-coated balloon angioplasty demonstrated favorable outcomes in repairing and reshaping the blood vessel wall in young patients.Therefore,it may be considered a promising treatment option for similar cases.
文摘The incidence of acute myocardial infarction (AMI) is increasing year by year, which seriously endangers human health around the world. The preferred treatment strategy for AMI patients is the use of drug-eluting stents (DES), as there is ample evidence to suggest that stent implantation can reduce major adverse cardiovascular events (MACEs). With the application of drug-coated balloons (DCBs) and the enhancement of the concept of interventional without implantation, the question is whether DCBs can be safely and effectively used in patients with AMI? The purpose of this study was to investigate the safety and effectiveness of DCBs in the treatment of AMI. A retrospective review of clinical data was conducted on 55 AMI patients who underwent primary percutaneous coronary intervention (PCI) from January 2020 to December 2021. Of these patients, 25 were treated with DCBs and 30 were treated with DESs. Optical coherence tomography (OCT) was used to measure the minimum lumen diameter, lumen stenosis, and coronary artery dissection before and after surgery, and angina pectoris attacks and various MACEs were recorded at 1, 6, and 12 months after surgery. The results showed that there were no significant differences in clinical baseline data between the two groups. However, the minimum lumen diameter of the DCB group immediately after the operation was smaller than that of the DES group, and the stenosis degree of the lumen in the DCB group was higher than that in the DES group. The incidence of coronary artery dissection in the DCB group was significantly higher than that in the DES group, but the majority of them were type B. At 1, 6, and 12 months after treatment, there was no significant difference in the occurrence of MACEs between the two groups. In conclusion, DCBs is a safe and effective treatment for AMI. However, the incidence of coronary artery dissection in DCB patients is higher than that in DES patients, but the majority of them are type B. .
基金funded by The Henan Province Young and Middle-aged Health Science and Technology Innovation Young Talent Training Project(,Grant/Award Number:YXKC20200041)National Health Commission Capacity Building and Continuing Education Project(Grant/Award Number:GWJJ2023100101)
文摘Background:Previous single-center studies have demonstrated that drug-coated balloons(DCBs)may reduce restenosis rates,which is an important factor affecting the prognosis for intracranial interventional therapy.However,currently available cardiac DCBs are not always suitable for the treatment of intracranial atherosclerotic stenosis(ICAS).This study aimed to evaluate the safety and efficacy of a novel DCB catheter designed for patients with severely symptomatic ICAS.Methods:This prospective,multicenter,single-arm,target-value clinical trial was conducted in 9 Chinese stroke centers to evaluate the safety and efficacy of a novel DCB catheter for treating symptomatic severe ICAS.Primary metrics and other indicators were collected and analyzed using SAS version 9.4(SAS Institute,Cary,NC,USA).Results:A total of 155 patients were enrolled in this study.The preliminary collection of follow-up data has been completed,while data quality control is ongoing.Conclusion:Results of this study demonstrated the patency rate,safety,and effectiveness of a novel on-label paclitaxel DCB designed for the treatment of ICAS.Ethics and dissemination:This study,involving human participants,was reviewed and approved by the Ethics Committee of Drugs(Devices)Clinical Experiment at Henan Provincial People’s Hospital(reference number:2020-145-03)and other research centers participating in the clinical trial.The results of this study will be presented at international conferences and sent to peer-reviewed journals for publication.Standard protocol items:The Recommendations for Interventional Trials checklist was used when drafting the study protocol.Trial registration number:Registered with the Chinese Clinical Trial Registry on June 11,2021(Chi CTR2100047223).
基金Supported by Shandong Provincial TCM Science and Technology Development Program Project,No.2019-0481Jining City Science and Technology Key Research and Development Program,No.2021YXNS069.
文摘BACKGROUND Percutaneous transluminal coronary angioplasty,while an effective intervention,can frequently lead to acute occlusion with severe consequences.Although clinical trials have demonstrated the efficacy of drug-coated balloons(DCB)in treating acute coronary artery occlusion and in preventing restenosis,there has been limited exploration on the use of DCB in treating de novo lesions in large vessels.Currently,DCB are only recommended for patients with small vessel lesions and in-stent restenosis lesions,those at high risk of bleeding,and other special groups of patients.CASE SUMMARY This report presents a case of successful drug-coated balloon treatment of de novo lesions in large coronary vessels.Postoperatively,the patient demonstrated favorable recovery,with subsequent examination results revealing no significant differences from the previous examination.CONCLUSION The successful treatment of the patient in our case highlights the potential of DCB in the treatment of de novo lesions in large coronary vessels.
基金supported by the Medical Science and Technique Research Plan of He’nan Province(Provincial and Ministerial Co-construction Project)(SB201901027).
文摘BACKGROUND Controversy exists as to the optimal treatment approach for ostial left anterior descending(LAD)or ostial left circumflex artery(LCx)lesions.Drug-coated balloons(DCB)may overcome some of the limitations of drug-eluting stents(DES).Therefore,we investigated the security and feasibility of the DCB policy in patients with ostial LAD or ostial LCx lesions,and compared it with the conventional DES-only strategy.METHODS We retrospectively enrolled patients with de novo ostial lesions in the LAD or LCx who underwent interventional treatment.They were categorized into two groups based on their treatment approach:the DCB group and the DES group.The treatment strategies in the DCB group involved the use of either DCB-only or hybrid strategies,whereas the DES group utilized crossover or precise stenting techniques.Two-year target lesion revascularization was the primary endpoint,while the rates of major adverse cardiovascular events,cardiac death,target vessel myocardial infarction,and vessel thrombosis were the secondary endpoints.Using propensity score matching,we assembled a cohort with comparable baseline characteristics.To ensure result analysis reliability,we conducted sensitivity analyses,including interaction,and stratified analyses.RESULTS Among the 397 eligible patients,6.25%of patients who were planned to undergo DCB underwent DES.A total of 108 patients in each group had comparable propensity scores and were included in the analysis.Two-year target lesion revascularization occurred in 5 patients(4.90%)and 16 patients(16.33%)in the DCB group and the DES group,respectively(odds ratio=0.264,95%CI:0.093–0.752,P=0.008).Compared with the DES group,the DCB group demonstrated a lower major adverse cardiovascular events rate(7.84%vs.19.39%,P=0.017).However,differences with regard to cardiac death,non-periprocedural target vessel myocardial infarction,and definite or probable vessel thrombosis between the groups were non-significant.CONCLUSIONS The utilization of the DCB approach signifies an innovative and discretionary strategy for managing isolated ostial lesions in the LAD or LCx.Nevertheless,a future randomized trial investigating the feasibility and safety of DCB compared to the DES-only strategy specifically for de novo ostial lesions in the LAD or LCx is highly warranted.
文摘In recent decades, the outcomes of coronary heart disease (CHD) have markedly improved, which can be partly attributed to the use of novel drugs (especially statins and antiplatelet drugs) and partly to the evolution ofpercutaneous coronary intervention (PCI). From percutaneous transluminal coronary angioplasty to bare-metal stent and then to drug-eluting stent, every step of PCI is attractive to interventional cardiologist, great progress has been made for patients with CHD. In the past few years, some successor devices for treating CHD have cmerged. Undoubtedly, drug-coated balloon (DCB), which was recommended by 2014 ESC Guidelines on myocardial revascularization, is a "shining star" among them. DCB involves a semi-compliant angioplasty balloon coated with an anti-proliferative agent that can exert antirestenotic efficacy by permeating into the vessel wall during balloon contact. This review discusses the conception and merits, preclinical data, emerging clinical indications, and results from clinical trials of this novel interventional technology. Although DCB has shown authentic efficacy in the treatment ofin-stent restenosis, its use in de novo coronary lesions is still in dispute. Hence, concerns and the future direction of DCB are also covered in this paper.
文摘BACKGROUND The in-stent restenosis(ISR)rates are reportedly inconsistent despite the increased use of second-generation drug eluting stent(DES).Although bioresorbable vascular scaffold(BVS)have substantial advantages with respect to vascular restoration,the rate of scaffold thrombosis is higher with BVS than with DES.Optimal treatment strategies have not been established for DES-ISR to date.CASE SUMMARY We report on a case of a 60-year-old man patient with acute coronary syndrome.He had a history of ST-segment elevation myocardial infarction associated with very late scaffold thrombosis and treated with a DES.Coronary angiography revealed significant stenosis,suggesting DES-ISR on the previous BVS.Optical coherence tomography(OCT)identified a plaque rupture and a disrupted scaffold strut in the neointimal proliferation of DES.To treat the DES-ISR on the previous BVS,we opted for a drug-coated balloon(DCB)after a balloon angioplasty using a semi-compliant and non-compliant balloon.The patient did not experience adverse cardiovascular events on using a DCB following the use of intensive dual antiplatelet therapy and statin for 24 mo.CONCLUSION This case highlights the importance of OCT as an imaging modality for characterizing the mechanism of target lesion failure.The use of a DCB following the administration of optimal pharmacologic therapy may be an optimal strategy for the treatment and prevention of recurrent BVS thrombosis and DES-ISR.
基金Support for this study was provided by the Funding Project of the National Natural Science Foundation of China(81774076)the Clinical Special Project of Shanghai Health and Family Planning Commission(201840247)+2 种基金the Shanghai Key Medical Specialties Construction Project(ZK2019A11)the Young Elite Scientists Sponsorship Program of CAST(QNRC2-B03)the Clinical Advantage Discipline of Health System of Putuo District in Shanghai(2019ysxk01).
文摘Objective:To evaluate the clinical efficacy of a drug-eluting stent(DES)combined with a drug-coated balloon(DCB)in the treatment of left main coronary artery bifurcation lesions.Methods:A retrospective analysis was conducted on the clinical data of eight patients with left main coronary artery bifurcation lesions treated with a DES combined with a DCB who were admitted to our hospital from July 2016 to July 2017.These eight patients all underwent DES treatment for their left main coronary artery and left anterior descending coronary artery lesions,and DCB treatment at the ostium of the left circumflex artery;six of the patients underwent surgical procedures under the guidance of intravascular ultrasonography.Immediate postoperative angiography was used to evaluate the patency of the diseased vessels,and the restenosis rate at the 6-month follow-up after the operation and the incidence of serious clinical events within 6 months were assessed as well.Results:The use of a DES combined with a DCB in the treatment of left main coronary artery bifurcation lesions had a low restenosis rate(left main coronary artery(8.4±5.3)%,left anterior descending coronary artery(18.2±5.0)%,left circumflex artery(30.5±16.5)%).No serious clinical events occurred in any patients.Conclusion:A DES combined with a DCB is a safe and effective interventional treatment for left main artery coro-nary bifurcation lesions.
文摘We evaluated the clinical feasibility of using drugcoated balloon(DCB) angioplasty in patients undergoingprimary percutaneous coronary intervention(PPCI). Between January 2010 to September 2014,89 STelevation myocardial infarction patients(83% male,mean age 59 ± 14 years) with a total of 89 coronary lesions were treated with DCB during PPCI. Clinical outcomes are reported at 30 d follow-up. Left anterior descending artery was the most common target vessel for PCI(37%). Twenty-eight percent of the patients had underlying diabetes mellitus. Mean left ventricular ejection fraction was 44% ± 11%. DCB-only PCI was the predominant approach(96%) with the remaining 4% of patients receiving bail-out stenting. Thrombolysis in Myocardial Infarction(TIMI) 3 flow was successfully restored in 98% of patients. An average of 1.2 ± 0.5 DCB were used per patient,with mean DCB diameter of 2.6 ± 0.5 mm and average length of 23.2 ± 10.2 mm. At 30-d follow-up,there were 4 deaths(4.5%). No patients experienced abrupt closure of the infarctrelated artery and there was no reported target-lesion failure. Our preliminary experience showed that DCB angioplasty in PPCI was feasible and associated with a high rate of TIMI 3 flow and low 30-d ischaemic event.
文摘Objective:The aim of this study was to compare the efficacy,safety and treatment costs of superficial femoral artery revascularization(SFA)with drug-coated balloon(DCB)versus avoiding revascularization strategy for the treatment of symptomatic SFA disease.Methods:This retrospective single-center study reviewed 96 patients(113 limbs)with severe stenosis and occlusive SFA disease.All patients underwent either DCB(Group 1:n=55 limbs)or nonrevascularization(Group2:n=58 limbs)between March 2015 and June 2019.The improvement of Rutherford class,walking impairment questionnaire score(WIQ),target limb reintervention,perioperative major adverse events,the catheterization laboratory cost and length of hospital stay were compared.The limb salvage and survival rates were calculated using the Kaplan-Meier method.Univariate and multivariate logistic regression analysis were performed to assess the association between factors and the improvement of Rutherford category at 12 months.Results:The median follow-up time of Groups 1 and 2 was 17 and 33 months,respectively.At 12 months,the Rutherford category significantly decreased in both groups(P<0.001),with no significant difference(79.7%vs.64.3%,P=0.074).Furthermore,multivariate analysis showed that the selected therapeutic method was not an influential factor for the improvement of Rutherford class at 12 months.The WIQ overall score as well as three subscales scores(distance,speed and stair-climbing),the survival rate,limb salvage rate and the length of stay between the two groups were comparable.The perioperative adverse events rate and catheterization laboratory cost in Group 2 was significantly lower compared to Group 1[(34253.69±28172.87)yuan vs.(56936.76±41278.36)yuan,P=0.001].Conclusions:This study suggests that avoiding superficial femoral artery revascularization strategy has favorable efficacy and safety outcomes compared to combining revascularization with DCB in selected patients.
文摘This retrospective single-center registry study included all consecutive patients who underwent percutaneous coronary intervention (PCI) for a de novo left main coronary artery lesion using drug coated-balloon (DCB)-only strategy between August 2011 and December 2018. To best of our knowledge, no previous studies of DCB-only strategy of treating de novo left main coronary artery disease, exist. The primary endpoint was major adverse cardiovascular events (MACEs) including cardiac death, non-fatal myocardial infarction, and target lesion revascularization (TLR). The cohort was divided into two groups depending on weather the lesion preparation was done according to the international consensus group guidelines. Sixty-six patients (mean age 75±8.6, 72% male), 52% of whom had acute coronary syndrome, underwent left main PCI with the DCB-only strategy. No procedural mortality and no acute closures of the treated left main occurred. At 12 months, MACE and TLR occurred in 24% and 6% of the whole cohort, respectively. If the lesion preparation was done according to the guidelines, the MACE and TLR rates were 21.2% and 1.9%. Left main PCI with the DCB only-strategy is safe leading to acceptable MACE and low TLR rates at one year, if the lesion preparation is done according to the guidelines.
文摘Background:Drug-coated balloons(DCBs)have emerged as potential alternatives to drug-eluting stents in specific lesion subsets for de novo coronary lesions.Quantitative flow ratio(QFR)is a method based on the three-dimensional quantitative coronary angiography and contrast flow velocity during coronary angiography(CAG),obviating the need for an invasive fractional flow reserve procedural.This study aimed to assess the serial angiographic changes of de novo lesions post-DCB therapy and further explore the cut-off values of lesion and vessel QFR,which predict vessel restenosis(diameter stenosis[DS]≥50%)at mid-term follow-up.Methods:The data of patients who underwent DCB therapy between January 2014 and December 2019 from the multicenter hospital were retrospectively collected for QFR analysis.From their QFR performances,which were analyzed by CAG images at follow-up,we divided them into two groups:group A,showing target vessel DS≥50%,and group B,showing target vessel DS<50%.The median follow-up time was 287 days in group A and 227 days in group B.We compared the clinical characteristics,parameters during DCB therapy,and QFR performances,which were analyzed by CAG images between the two groups,in need to explore the cut-off value of lesion/vessel QFR which can predict vessel restenosis.Student's t test was used for the comparison of normally distributed continuous data,Mann-Whitney U test for the comparison of non-normally distributed continuous data,and receiver operating characteristic(ROC)curves for the evaluation of QFR performance which can predict vessel restenosis(DS≥50%)at mid-term follow-up using the area under the curve(AUC).Results:A total of 112 patients with 112 target vessels were enrolled in this study.Group A had 41 patients,while group B had 71.Vessel QFR and lesion QFR were lower in group A than in group B post-DCB therapy,and the cut-off values of lesion QFR and vessel QFR in the ROC analysis to predict target vessel DS≥50%post-DCB therapy were 0.905(AUC,0.741[95%confidence interval,CI:0.645,0.837];sensitivity,0.817;specificity,0.561;P<0.001)and 0.890(AUC,0.796[95%CI:0.709,0.882];sensitivity,0.746;specificity,0.780;P<0.001).Conclusions:The cut-off values of lesion QFR and vessel QFR can assist in predicting the angiographic changes post-DCB therapy.When lesion/vessel QFR values are<0.905/0.890 post-DCB therapy,a higher risk of vessel restenosis is potentially predicted at follow-up.
基金the Natural Science Foundation of China(no.81700321).
文摘Background:Drug-coated balloons(DCBs)are an up-and-coming tactic in treating in-stent restenosis and coronary artery small vessel disease,but their efficacy in treating acute myocardial infarction needs to be further explored.Methods:A meta-analysis of 7 studies was conducted to make a comparison with the results of DCB and drug-eluting stent implantation after a median follow-up of 15 months.Results:A total of 922 patients were included in this analysis in total,including 375 patients in the DCB group and 547 patients in the stent group.A total of 962 vascular diseases were manifested in the 2 groups.After 6 to 24 months of follow-up,there was no statistically significant difference with respect to major adverse cardiovascular events(odds ratio[OR]:0.82;95%confidence interval[CI]:0.52–1.29;Z=0.85;P=0.39),cardiac death(OR:0.92;95%CI:0.39–2.12;Z=0.21;P=0.84),target lesion revascularization(OR:1.09;95%CI:0.53–2.25;Z=0.24;P=0.81),late lumen loss(MD:−0.05;95%CI:−0.15 to 0.06;Z=0.85;P=0.40),or dual antiplatelet therapy(DAPT)(OR:1.04;95%CI:0.53–2.05;Z=0.11;P=0.91)between the 2 groups.In the DCB group,persistent residual stenosis or C-F dissection occurrence necessitated that a total of 30 patients receive extra bailout implantations.The rate of bailout stenting was 11.8%(95%CI:7.1–16).Moreover,the DCB group had a shorter DAPT duration compared with the stent group.Conclusion:Drug-coated balloons with shorter DAPT durations may be as effective and safe as stent therapy in treating acute myocardial infarction.
文摘Percutaneous coronary interventions have progressed through the era of plain balloon dilation, bare-metal stent insertion to drug-eluting stent treatment, which has significantly reduced the acute occlusion and restenosis rates of target vessels and improved patient prognosis, making drug-eluting stents the mainstream interventional treatment for coronary artery disease. In recent years, drug-coated balloons(DCBs) have become a new treatment strategy for coronary artery disease, and the drugs used in the coating and the coating technology have progressed in the past years. Without permanent implant, a DCB delivers antiproliferative drugs rapidly and uniformly into the vessel wall via the excipient during a single balloon dilation. Many evidence suggests that DCB angioplasty is an effective measure for dealing with in-stent restenosis and de novo lesions in small coronary vessels.As more clinical studies are published, new evidence is emerging for the use of DCB angioplasty in a wide range of coronary diseases, and the indications are expanding internationally. Based on the latest research from China and elsewhere, the Expert Writing Committee of the Chinese Expert Consensus on Clinical Applications of Drug-Coated Balloon has updated the previous DCB consensus after evidence-based discussions and meetings in terms of adequate preparation of in-stent restenosis lesions, expansion of the indications for coronary de novo lesions, and precise guidance of DCB treatment by intravascular imaging and functional evaluation.
文摘Aortic stenosis(AS)stands out as the most prevalent individual valvular defect globally.The onset and progression of AS mirror an active process akin to atherosclerosis,and the traditional triad of symptoms includes chest pain,breathlessness,and loss of consciousness.Prognosis takes a significant downturn when symptoms manifest,with mortality reaching approximately 50%-85% within the subsequent 5 years after symptom onset.
文摘The X-ray sources of the universe are extraterrestrial in nature which emit X-ray photons.The closest strong X-ray source is the Sun,which is followed by various compact sources such as neutron stars,black holes,the Crab pulsar,etc.In this paper,we analyze the data received from several low-cost lightweight meteorological balloon-borne missions launched by the Indian Centre for Space Physics.Our main interest is to study the variation of the vertical intensity of secondary cosmic rays,the detection of strong X-ray sources,and their spectra in the energy band of^(1)0–80 keV during the complete flights.Due to the lack of an onboard pointing system,low exposure time,achieving a maximum altitude of only~42 km,and freely rotating the payload about its axis,we modeled the background radiation flux for the X-ray detector using physical assumptions.We also present the source detection method,observation of the pulsation of the Crab(^(3)3 Hz),and spectra of some sources such as the quiet Sun and the Crab pulsar.
文摘Objective:To prospectively follow up a cohort of anterior urethral stricture disease patients managed with balloon dilation(BD)for 3 years to evaluate the long-term outcomes and to study factors that contribute to recurrence.Methods:This study included men who had urethral BD for significant anterior urethral stricture disease between January 2017 and March 2019.Data about the patient age,stricture characteristics,and recurrence date were recorded,along with information on postoperative indwelling catheter use and operative complications.Furthermore,information about the self-calibration procedure was collected and where available,free flow(FF)measurements during the follow-up period were recorded and analyzed.Success was defined as a lack of symptoms and acceptable FF rates(maximum flow rate>12 mL/s).Results:The final analysis was conducted on 187 patients.The mean follow-up period was 37 months.The long-term overall success rate at the end of our study was 66.8%.Our recurrence rate was 7.4%at 12 months,24.7%at 24 months,and reached 33.2%at the end of our study.The time to recurrence ranged from 91 days to 1635 days,with a mean of 670 days.The stricture-free survival was significantly shorter with lengthy peno-bulbar(p=0.031)and multiple strictures(p=0.015),and in the group of patients who were not committed to self-calibration protocol(p<0.011).However,post-procedural self-calibration was the most important factor that may have decreased the incidence of recurrence(odds ratioZ5.85).Adjuvant self-calibration after BD not only reduced the recurrence rate from 85.4%in the non-self-calibration group to 15.1%in the self-calibration one(p<0.001),but also improved the overall stricture-free survival and FF parameters.
基金supported by military logistics scientific research project(AHJ16J004)。
文摘BACKGROUND:Resuscitative endovascular balloon occlusion of the aorta(REBOA)can temporarily control traumatic bleeding.However,its prolonged use potentially leads to ischemia-reperfusion injury(IRI).Partial REBOA(pREBOA)can alleviate ischemic burden;however,its security and eff ectiveness prior to operative hemorrhage control remains unknown.Hence,we aimed to estimate the effi cacy of pREBOA in a swine model of liver injury using an experimental sliding-chamber ballistic gun.METHODS:Twenty Landrace pigs were randomized into control(no aortic occlusion)(n=5),intervention with complete REBOA(cREBOA)(n=5),continuous pREBOA(C-pREBOA)(n=5),and sequential pREBOA(S-pREBOA)(n=5)groups.In the cREBOA and C-pREBOA groups,the balloon was inflated for 60 min.The hemodynamic and laboratory values were compared at various observation time points.Tissue samples immediately after animal euthanasia from the myocardium,liver,kidneys,and duodenum were collected for histological assessment using hematoxylin and eosin staining.RESULTS:Compared with the control group,the survival rate of the REBOA groups was prominently improved(all P<0.05).The total volume of blood loss was markedly lower in the cREBOA group(493.14±127.31 mL)compared with other groups(P<0.01).The pH was significantly lower at 180 min in the cREBOA and S-pREBOA groups(P<0.05).At 120 min,the S-pREBOA group showed higher alanine aminotransferase(P<0.05)but lower blood urea nitrogen compared with the cREBOA group(P<0.05).CONCLUSION:In this trauma model with liver injury,a 60-minute pREBOA resulted in improved survival rate and was effective in maintaining reliable aortic pressure,despite persistent hemorrhage.Extended tolerance time for aortic occlusion in Zone I for non-compressible torso hemorrhage was feasible with both continuous partial and sequential partial measures,and the significant improvement in the severity of acidosis and distal organ injury was observed in the sequential pREBOA.
文摘BACKGROUND Over one-third of Americans carry the diagnosis of obesity,many also with obesity-related comorbidities.This can place patients at increased risk of operative and postoperative complications.The intragastric balloon has been shown to aid in minor weight loss,however its weight recidivism in patients requiring short interval weight loss has not been well studied.AIM To evaluate weight loss,ability to undergo successful elective surgery after intragastric balloon placement,and weight management after balloon removal.METHODS This study is a retrospective review of patients in a single academic institution undergoing intragastric balloon placement from 2019-2023 to aid in weight loss prior to undergoing elective surgery.Clinical outcomes including weight loss,duration of balloon placement,successful elective surgery,weight regain postballoon and post-procedure complications were assessed.Exclusion criteria included those with balloon in place at time of study.RESULTS Thirty-three patients completed intragastric balloon therapy from 2019-2023 as a bridge to elective surgery.All patients were required to participate in a 12-month weight management program to be eligible for balloon therapy.Elective surgeries included incisional hernia repair,umbilical hernia repair,inguinal hernia repair,and knee and hip replacements.The average age at placement was 53 years±11 years,majority(91%)were male.The average duration of intragastric balloon therapy was 186 days±41 days.The average weight loss was 14.0 kg±7.4 kg and with an average percent excess body weight loss of 30.0%(7.9%-73.6%).Over half of the patients(52.0%)achieved the goal of 30-50 lbs(14-22 kg)weight loss.Twenty-one patients(64%)underwent their intended elective surgery,2 patients(6%)deferred surgery due to symptom relief with weight loss alone.Twenty-one of the patients(64%)have documented weights in 3 months after balloon removal,in these patients the majority(76%)gained weight after balloon removed.In patients with weight regain at 3 months,they averaged 5.8 kg after balloon removal in the first 3 months,this averaged 58.4%weight regain of the initial weight lost.CONCLUSION Intragastric balloon placement is an option for short-term weight management,as a bridge to elective surgery in patients with body mass index(BMI)>35.Patients lost an average of 14 kg with the balloon,allowing two-thirds of patients to undergo elective surgery at a healthy BMI.However,most patients regained an average of 58%of the original weight lost after balloon removal.The intragastric balloon successfully serves as a tool for rapid weight loss,though patients must be educated on the risks including weight regain.
文摘BACKGROUND Endoscopic retrograde cholangiopancreatography(ERCP),with its clinical ad-vantages of less trauma and faster recovery,has become the primary treatment for choledocholithiasis.AIM To investigate the effects of different ERCP procedures on the sphincter of Oddi.METHODS The clinical data of 91 patients who underwent ERCP at Yixing Hospital of Traditional Chinese Medicine between February 2018 and February 2021 were analyzed retrospectively.The patients were divided into endoscopic sphinc-terotomy(EST,n=24)and endoscopic papillary balloon dilation(EPBD,n=67)groups.The duration of operation,pancreatic development,pancreatic sphinc-terotomy,intubation difficulties,stone recurrence,and incidence of reflux cho-langitis and cholecystitis were statistically analyzed in patients with a history of choledocholithiasis,pancreatitis,and Oddi sphincter dysfunction in the EST and EPBD groups.RESULTS Differences in hypertension,diabetes,increased bilirubin,small diameter of the common bile duct,or ampullary diverticulum between the two groups were not significant.Statistically significant differences were observed between the two groups concerning sex and age(<60 years).Patients with a history of choledocholithiasis,pancreatitis,and Oddi sphincter dysfunction were higher in the EST group than in the EPBD group.The number of cases of pancreatic development,pancreatic duct sphincterotomy,and difficult intubation were higher in the EST group than in the EPBD group.The number of Oddi’s sphincter manometries,ERCP surgical outcomes,and guidewires entering the pancreatic duct several times in EST group were lower than those in the EPBD group.The numbers of stone recurrences,reflux cholangitis,and cholecystitis were higher in the EST group than in the EPBD group.CONCLUSION In summary,common bile duct stones,pancreatitis history,and multiple guided wire introductions into the pancreatic duct are independent risk factors for EST and EPBD.Based on this evidence,this study can provide actionable insights for clinicians and researchers.