All-solid-state lithium-sulfur batteries(ASSLSBs)employing sulfide solid electrolytes are one of the most promising next-generation energy storage systems due to their potential for higher energy density and safety.Ho...All-solid-state lithium-sulfur batteries(ASSLSBs)employing sulfide solid electrolytes are one of the most promising next-generation energy storage systems due to their potential for higher energy density and safety.However,scalable fabrication of sheet-type sulfur cathodes with high sulfur loading and excellent performances remains challenging.In this work,sheet-type freestanding sulfur cathodes with high sulfur loading were fabricated by dry electrode technology.The unique fibrous morphologies of polytetrafluoroethylene(PTFE)binders in dry electrodes not only provides excellent mechanical properties but also uncompromised ionic/electronic conductance.Even employed with thickened dry cathodes with high sulfur loading of 2 mg cm^(-2),ASSLSBs still exhibit outstanding rate performance and cycle stability.Moreover,the all-solid-state lithium-sulfur monolayer pouch cells(9.2 m Ah)were also demonstrated and exhibited excellent safety under a harsh test situation.This work verifies the potential of dry electrode technology in the scalable fabrication of thickened sulfur cathodes and will promote the practical applications of ASSLSBs.展开更多
Microneedle array(MNA)electrodes are an effective solution to achieve high-quality surface biopotential recording without the coordination of conductive gel and are thus very suitable for long-term wearable applicatio...Microneedle array(MNA)electrodes are an effective solution to achieve high-quality surface biopotential recording without the coordination of conductive gel and are thus very suitable for long-term wearable applications.Existing schemes are limited by flexibility,biosafety,and manufacturing costs,which create large barriers for wider applications.Here,we present a novel flexible MNA electrode that can simultaneously achieve flexibility of the substrate to fit a curved body surface,robustness of microneedles to penetrate the skin without fracture,and a simplified process to allow mass production.The compatibility with wearable wireless systems and the short preparation time of the electrodes significantly improves the comfort and convenience of electrophysiological recording.The normalized electrode–skin contact impedance reaches 0.98 kΩcm^(2)at 1 kHz and 1.50 kΩcm^(2)at 10 Hz,a record low value compared to previous reports and approximately 1/250 of the standard electrodes.The morphology,biosafety,and electrical/mechanical properties are fully characterized,and wearable recordings with a high signal-to-noise ratio and low motion artifacts are realized.The first reported clinical study of microneedle electrodes for surface electrophysiological monitoring was conducted in tens of healthy and sleep-disordered subjects with 44 nights of recording(over 8 h per night),providing substantial evidence that the electrodes can be leveraged to substitute for clinical standard electrodes.展开更多
Long-term biopotential monitoring requires high-performance biocompatible wearable dry electrodes.But currently,it is challenging to establish a form-preserving fit with the skin,resulting in high interface impedance ...Long-term biopotential monitoring requires high-performance biocompatible wearable dry electrodes.But currently,it is challenging to establish a form-preserving fit with the skin,resulting in high interface impedance and motion artifacts.This research aims to present an innovative solution using an all-green organic dry electrode that eliminates the aforementioned challenges.The dry electrode is prepared by introducing biocompatible maltitol into the chosen conductive polymer,poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate).Thanks to the secondary doping and plasticizer effect of maltitol,the dry electrode exhibits good stretchability(62%),strong self-adhesion(0.46 N/cm),high conductivity(102 S/cm),and low Young's modulus(7 MPa).It can always form a conformal contact with the skin even during body movements.Together with good electrical properties,the electrode enables a lower skin contact impedance compared to the current standard Ag/AgCl gel electrode.Consequently,the application of this dry electrode in bioelectrical signal measurement(electromyography,electrocardiography,electroencephalogra-phy)and long-term biopotential monitoring was successfully demonstrated.展开更多
Electroencephalogram(EEG) signals provide important brain information in healthcare settings. Wet electrodes have several limitations, including their time-consuming preparation and no long-term acquisition, and dry e...Electroencephalogram(EEG) signals provide important brain information in healthcare settings. Wet electrodes have several limitations, including their time-consuming preparation and no long-term acquisition, and dry electrodes have become a promising candidate. However, dry electrodes face several challenges related to signal quality, comfort, conductivity and cost.This study aims to develop and evaluate a novel dry electrode for EEG recordings. The electrode material properties are characterized by electrochemical, mechanical force, and skin measurements. The electrode performance is evaluated by comparing the impedance, signal-to-noise ratio(SNR), and EEG signal features of the proposed electrode with those of a wet electrode and two commercial dry electrodes. The dry electrode design is based on the biological structure of the sea anemone and demonstrates an improved scalp fit and reduced signal noise and motion artifacts. The electrode materials include advanced conducting polymers combined with thermoplastic elastomers(TPEs) and carbon nanotubes(CNTs), which exhibit good electrical conductivity, mechanical properties, and safety. A low-cost injection molding fabrication method is proposed. The dry electrodes show a scalp contact impedance of 7 kΩ at 20 Hz, which is lower than that of wet and commercial dry electrodes.Resting-state EEG and event-related potential signals collected by the anemone dry electrode achieved more than 90% similarity with signals acquired by wet electrodes. Thus, a low-cost, comfortable anemone dry electrode that exhibits excellent EEG recording performance is presented. The anemone dry electrode represents an important technological advance in material and structural design for EEG recording sensors.展开更多
This paper describes a low-power portable sensor interface dedicated to sensing and processing elec- trocardiogram (ECG) signals. Dry electrodes were employed in this ECG sensor, which eliminates the need of conduct...This paper describes a low-power portable sensor interface dedicated to sensing and processing elec- trocardiogram (ECG) signals. Dry electrodes were employed in this ECG sensor, which eliminates the need of conductive gel and avoids complicated and mandatory skin preparation before electrode attachment. This ECG sensor system consists of two ICs, an analog front-end (AFE) and a successive approximation register analog-to- digital converter (SAR ADC) containing a relaxation oscillator. This proposed design was fabricated in a 0.18 #m 1P6M standard CMOS process. The AFE for extracting the biopotential signals is essential in this ECG sensor. In measurements, the AFE obtains a mid-band gain of 45 dB, referred noise of 2.8μV rms while consuming 1μW from the a bandwidth from 0.6 to 160 Hz, and a total input 1.8 V supply. The noise efficiency factor (NEF) of our design is 3.4. After conditioning, the amplified ECG signal is digitized by a 12-bit SAR ADC with 61.8 dB SNDR and 220 fJ/conversion-step. Finally, a complete ECG sensor interface with three dry copper electrodes is demonstrated in real-word setting, showing successful recordings of a capture ECG waveform.展开更多
Electrocardiogram(ECG)monitoring is used to diagnose cardiovascular diseases,for which wearable electronics have attracted much attention due to their lightweight,comfort,and long-term use.This study developed a weara...Electrocardiogram(ECG)monitoring is used to diagnose cardiovascular diseases,for which wearable electronics have attracted much attention due to their lightweight,comfort,and long-term use.This study developed a wearablemultilead ECG sensing system with on-skin stretchable and conductive silver(Ag)-coated fiber/silicone(AgCF-S)dry adhesives.Tangential and normal adhesion to pigskin(0.43 and 0.20 N/cm2,respectively)was optimized by the active control of fiber density and mixing ratio,resulting in close contact in the electrode–skin interface.The breathableAgCF-S dry electrodewas nonallergenic after continuous fit for 24 h and can be reused/cleaned(>100 times)without loss of adhesion.The AgCF encapsulated inside silicone elastomers was overlapped to construct a dynamic network under repeated stretching(10%strain)and bending(90°)deformations,enabling small intrinsic impedance(0.3,0.1 Hz)and contact impedance variation(0.7 k)in high-frequency vibration(70 Hz).All hard/soft modules of the multilead ECG system were integrated into lightweight clothing and equipped with wireless transmission for signal visualization.By synchronous acquisition of I–III,aVR,aVL,aVF,and V4 lead data,the multilead ECG sensing system was suitable for various scenarios,such as exercise,rest,and sleep,with extremely high signal-to-noise ratios.展开更多
基金supported by the National Key Research and Development Program of China(2021YFB2500300)the National Natural Science Foundation of China(22075029,22108151,22109084)the China Postdoctoral Science Foundation(2021TQ0164)。
文摘All-solid-state lithium-sulfur batteries(ASSLSBs)employing sulfide solid electrolytes are one of the most promising next-generation energy storage systems due to their potential for higher energy density and safety.However,scalable fabrication of sheet-type sulfur cathodes with high sulfur loading and excellent performances remains challenging.In this work,sheet-type freestanding sulfur cathodes with high sulfur loading were fabricated by dry electrode technology.The unique fibrous morphologies of polytetrafluoroethylene(PTFE)binders in dry electrodes not only provides excellent mechanical properties but also uncompromised ionic/electronic conductance.Even employed with thickened dry cathodes with high sulfur loading of 2 mg cm^(-2),ASSLSBs still exhibit outstanding rate performance and cycle stability.Moreover,the all-solid-state lithium-sulfur monolayer pouch cells(9.2 m Ah)were also demonstrated and exhibited excellent safety under a harsh test situation.This work verifies the potential of dry electrode technology in the scalable fabrication of thickened sulfur cathodes and will promote the practical applications of ASSLSBs.
基金supported by the China Capital Health Research and Development of Special (No. 2018-14111)the National Natural Science Foundation of China (grant No. 62004007 and No. 82027805)the China Postdoctoral Science Foundation Grant (No. 2021M700258)
文摘Microneedle array(MNA)electrodes are an effective solution to achieve high-quality surface biopotential recording without the coordination of conductive gel and are thus very suitable for long-term wearable applications.Existing schemes are limited by flexibility,biosafety,and manufacturing costs,which create large barriers for wider applications.Here,we present a novel flexible MNA electrode that can simultaneously achieve flexibility of the substrate to fit a curved body surface,robustness of microneedles to penetrate the skin without fracture,and a simplified process to allow mass production.The compatibility with wearable wireless systems and the short preparation time of the electrodes significantly improves the comfort and convenience of electrophysiological recording.The normalized electrode–skin contact impedance reaches 0.98 kΩcm^(2)at 1 kHz and 1.50 kΩcm^(2)at 10 Hz,a record low value compared to previous reports and approximately 1/250 of the standard electrodes.The morphology,biosafety,and electrical/mechanical properties are fully characterized,and wearable recordings with a high signal-to-noise ratio and low motion artifacts are realized.The first reported clinical study of microneedle electrodes for surface electrophysiological monitoring was conducted in tens of healthy and sleep-disordered subjects with 44 nights of recording(over 8 h per night),providing substantial evidence that the electrodes can be leveraged to substitute for clinical standard electrodes.
基金Chongqing Funds for Distinguished Young Scientists,Grant/Award Number:cstc2021jcyj-jqX0033Key Laboratory of Flexible Electronics of Zhejiang Province,Grant/Award Number:2022FE003+4 种基金Youth Talent Support Program of Chongqing,Grant/Award Numbers:CQYC2021059206,cstc2021ycjhbgzxm0334National Key Research and Development Program of China,Grant/Award Number:2022YFB3803300National Natural Science Foundation of China,Grant/Award Numbers:52203211,62074022Natural Science Foundation of Chongqing Municipality,Grant/Award Number:cstc2020jcyjmsxmX0851High-Level Medical Reserved Personnel Training Project of Chongqing,Grant/Award Number:2020GDRC019。
文摘Long-term biopotential monitoring requires high-performance biocompatible wearable dry electrodes.But currently,it is challenging to establish a form-preserving fit with the skin,resulting in high interface impedance and motion artifacts.This research aims to present an innovative solution using an all-green organic dry electrode that eliminates the aforementioned challenges.The dry electrode is prepared by introducing biocompatible maltitol into the chosen conductive polymer,poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate).Thanks to the secondary doping and plasticizer effect of maltitol,the dry electrode exhibits good stretchability(62%),strong self-adhesion(0.46 N/cm),high conductivity(102 S/cm),and low Young's modulus(7 MPa).It can always form a conformal contact with the skin even during body movements.Together with good electrical properties,the electrode enables a lower skin contact impedance compared to the current standard Ag/AgCl gel electrode.Consequently,the application of this dry electrode in bioelectrical signal measurement(electromyography,electrocardiography,electroencephalogra-phy)and long-term biopotential monitoring was successfully demonstrated.
基金supported by the National Natural Science Foundation of China (Grant Nos. U20A20191, 82202291, 61727807, and 12104049)。
文摘Electroencephalogram(EEG) signals provide important brain information in healthcare settings. Wet electrodes have several limitations, including their time-consuming preparation and no long-term acquisition, and dry electrodes have become a promising candidate. However, dry electrodes face several challenges related to signal quality, comfort, conductivity and cost.This study aims to develop and evaluate a novel dry electrode for EEG recordings. The electrode material properties are characterized by electrochemical, mechanical force, and skin measurements. The electrode performance is evaluated by comparing the impedance, signal-to-noise ratio(SNR), and EEG signal features of the proposed electrode with those of a wet electrode and two commercial dry electrodes. The dry electrode design is based on the biological structure of the sea anemone and demonstrates an improved scalp fit and reduced signal noise and motion artifacts. The electrode materials include advanced conducting polymers combined with thermoplastic elastomers(TPEs) and carbon nanotubes(CNTs), which exhibit good electrical conductivity, mechanical properties, and safety. A low-cost injection molding fabrication method is proposed. The dry electrodes show a scalp contact impedance of 7 kΩ at 20 Hz, which is lower than that of wet and commercial dry electrodes.Resting-state EEG and event-related potential signals collected by the anemone dry electrode achieved more than 90% similarity with signals acquired by wet electrodes. Thus, a low-cost, comfortable anemone dry electrode that exhibits excellent EEG recording performance is presented. The anemone dry electrode represents an important technological advance in material and structural design for EEG recording sensors.
基金supported by the National High Technology Research and Development Program of China(No.2100AA100701)the National Natural Science Foundation of China(Nos.61076027,61177021)the State Key Laboratory of ASIC & System,Fudan University
文摘This paper describes a low-power portable sensor interface dedicated to sensing and processing elec- trocardiogram (ECG) signals. Dry electrodes were employed in this ECG sensor, which eliminates the need of conductive gel and avoids complicated and mandatory skin preparation before electrode attachment. This ECG sensor system consists of two ICs, an analog front-end (AFE) and a successive approximation register analog-to- digital converter (SAR ADC) containing a relaxation oscillator. This proposed design was fabricated in a 0.18 #m 1P6M standard CMOS process. The AFE for extracting the biopotential signals is essential in this ECG sensor. In measurements, the AFE obtains a mid-band gain of 45 dB, referred noise of 2.8μV rms while consuming 1μW from the a bandwidth from 0.6 to 160 Hz, and a total input 1.8 V supply. The noise efficiency factor (NEF) of our design is 3.4. After conditioning, the amplified ECG signal is digitized by a 12-bit SAR ADC with 61.8 dB SNDR and 220 fJ/conversion-step. Finally, a complete ECG sensor interface with three dry copper electrodes is demonstrated in real-word setting, showing successful recordings of a capture ECG waveform.
基金supported by the Natural Science Foundation of Guangdong Province,China(No.2021B1515020087)the National Natural Science Foundation of China(No.51905178)the Climbing Program Foundation of Guangdong Province(No.pdjh2022a0024).
文摘Electrocardiogram(ECG)monitoring is used to diagnose cardiovascular diseases,for which wearable electronics have attracted much attention due to their lightweight,comfort,and long-term use.This study developed a wearablemultilead ECG sensing system with on-skin stretchable and conductive silver(Ag)-coated fiber/silicone(AgCF-S)dry adhesives.Tangential and normal adhesion to pigskin(0.43 and 0.20 N/cm2,respectively)was optimized by the active control of fiber density and mixing ratio,resulting in close contact in the electrode–skin interface.The breathableAgCF-S dry electrodewas nonallergenic after continuous fit for 24 h and can be reused/cleaned(>100 times)without loss of adhesion.The AgCF encapsulated inside silicone elastomers was overlapped to construct a dynamic network under repeated stretching(10%strain)and bending(90°)deformations,enabling small intrinsic impedance(0.3,0.1 Hz)and contact impedance variation(0.7 k)in high-frequency vibration(70 Hz).All hard/soft modules of the multilead ECG system were integrated into lightweight clothing and equipped with wireless transmission for signal visualization.By synchronous acquisition of I–III,aVR,aVL,aVF,and V4 lead data,the multilead ECG sensing system was suitable for various scenarios,such as exercise,rest,and sleep,with extremely high signal-to-noise ratios.