期刊文献+
共找到40,329篇文章
< 1 2 250 >
每页显示 20 50 100
Gadolinium Enhances Dual-energy Computed Tomography Scan of Pulmonary Artery
1
作者 An XIE Wen-jie SUN +3 位作者 Yan-feng ZENG Peng LIU Jian-bin LIU Feng HUANG 《Current Medical Science》 SCIE CAS 2022年第6期1310-1318,共9页
Objective To evaluate the feasibility of using gadopentetate dimeglumine(Gd-DTPA)for dual-energy computed tomography pulmonary angiography(CTPA).Methods Sixty-six patients were randomly divided into three groups and u... Objective To evaluate the feasibility of using gadopentetate dimeglumine(Gd-DTPA)for dual-energy computed tomography pulmonary angiography(CTPA).Methods Sixty-six patients were randomly divided into three groups and underwent CTPA.Group A had a turbo flash scan using an iohexol injection,Group B had a turbo flash scan using Gd-DTPA,and Group C had a dual-energy scan using Gd-DTPA.The original images of Group C were linearly blended with a blending factor of 0.5 or reconstructed at 40,50,60,70,80,90,100,and 110 keV,respectively.The groups were compared in terms of pulmonary artery CT value,image quality,and radiation dose.Results The pulmonary artery CT values were significantly higher in Group C40keV than in Groups B and C,but lower than in Group A.There was no significant difference in the image noise of Groups C40keV,B,and C.Moreover,Group A had the largest beam hardening artifacts of the superior vena cava(SVC),followed by Groups B and C.Group C40keV showed better vascular branching than the other three groups,among which Group B was superior to Group A.The subjective score of the image quality of Groups A,B,and C showed no significant difference,but the score was significantly higher in Group C40keV than in Groups A and B.The radiation dose was significantly lower in Group B than in Groups A and C.Conclusion Gd-CTPA is recommended to patients who are unsuitable for receiving an iodine-based CTPA.Furthermore,a turbo flash scan could surpass a dual-energy scan without consideration for virtual monoenergetic imaging. 展开更多
关键词 gadopentetate dimeglumine computed tomography pulmonary angiography dual-energy scan turbo flash scan virtual monoenergetic imaging
下载PDF
Dual-Energy X-Ray Computed Tomography Scanner Using Two Different Energy-Selection Electronics and a Lutetium-Oxyorthosilicate Photomultiplier Detector
2
作者 Osahiko Hagiwara Eiichi Sato +6 位作者 Yasuyuki Oda Satoshi Yamaguchi Yuichi Sato Hiroshi Matsukiyo Toshiyuki Enomoto Manabu Watanabe Shinya Kusachi 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2017年第3期266-279,共14页
To obtain two kinds of tomograms at two different X-ray energy ranges simultaneously, we have constructed a dual-energy X-ray photon counter with a lutetium-oxyorthosilicate photomultiplier detector system, three comp... To obtain two kinds of tomograms at two different X-ray energy ranges simultaneously, we have constructed a dual-energy X-ray photon counter with a lutetium-oxyorthosilicate photomultiplier detector system, three comparators, two microcomputers, and two frequency-voltage converters. X-ray photons are detected using the detector system, and the event pulses are input to three comparators simultaneously to determine threshold energies. At a tube voltage of 100 kV, the three threshold energies are 16, 35 and 52 keV, and two energy ranges are 16 - 35 and 52 - 100 keV. X-ray photons in the two ranges are counted using microcomputers, and the logical pulses from the two microcomputers are input to two frequency-voltage converters. In dual-energy computed tomography (CT), the tube voltage and current were 100 kV and 0.29 mA, respectively. Two tomograms were obtained simultaneously at two energy ranges. The energy ranges for gadolinium-L-edge and K-edge CT were 16 - 35 and 52 - 100 keV, respectively. The maximum count rate of dual-energy CT was 105 kilocounts per second with energies ranging from 16 to 100 keV, and the exposure time for tomography was 19.6 min. 展开更多
关键词 X-Ray Photon Counting LSO-PMT DETECTOR dual-energy Counter Energy-Dispersive CT Gd-L-Edge CT Gd-K-Edge CT
下载PDF
A landslide monitoring method using data from unmanned aerial vehicle and terrestrial laser scanning with insufficient and inaccurate ground control points 被引量:1
3
作者 Jiawen Zhou Nan Jiang +1 位作者 Congjiang Li Haibo Li 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第10期4125-4140,共16页
Non-contact remote sensing techniques,such as terrestrial laser scanning(TLS)and unmanned aerial vehicle(UAV)photogrammetry,have been globally applied for landslide monitoring in high and steep mountainous areas.These... Non-contact remote sensing techniques,such as terrestrial laser scanning(TLS)and unmanned aerial vehicle(UAV)photogrammetry,have been globally applied for landslide monitoring in high and steep mountainous areas.These techniques acquire terrain data and enable ground deformation monitoring.However,practical application of these technologies still faces many difficulties due to complex terrain,limited access and dense vegetation.For instance,monitoring high and steep slopes can obstruct the TLS sightline,and the accuracy of the UAV model may be compromised by absence of ground control points(GCPs).This paper proposes a TLS-and UAV-based method for monitoring landslide deformation in high mountain valleys using traditional real-time kinematics(RTK)-based control points(RCPs),low-precision TLS-based control points(TCPs)and assumed control points(ACPs)to achieve high-precision surface deformation analysis under obstructed vision and impassable conditions.The effects of GCP accuracy,GCP quantity and automatic tie point(ATP)quantity on the accuracy of UAV modeling and surface deformation analysis were comprehensively analyzed.The results show that,the proposed method allows for the monitoring accuracy of landslides to exceed the accuracy of the GCPs themselves by adding additional low-accuracy GCPs.The proposed method was implemented for monitoring the Xinhua landslide in Baoxing County,China,and was validated against data from multiple sources. 展开更多
关键词 Landslide monitoring Data fusion Terrestrial laser scanning(TLS) Unmanned aerial vehicle(UAV) Model reconstruction
下载PDF
Acousto-optic scanning multi-photon lithography with high printing rate
4
作者 Minghui Hong 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2024年第2期1-3,共3页
As a manufacturing method that is focused on end-users,3D printing has gained a lot of attention in recent years due to its unique advantages in fabricating complex three-dimensional structures.Various new micro-nano ... As a manufacturing method that is focused on end-users,3D printing has gained a lot of attention in recent years due to its unique advantages in fabricating complex three-dimensional structures.Various new micro-nano 3D printing methods have been developed to meet the demand for high-precision and high-yield manufacturing1-9.Among them,multi-photon-photon lithography(MPL) is a promising 3D nanofabrication technology due to its capability of true 3D digital processing and nanoscale processing resolution beyond the diffraction limit.It has been widely used to fabricate microoptics10,11,photonic crystals12,microfluidics13,meta-surfaces14,and mechanical metamaterials15. 展开更多
关键词 PHOTON Acous scanNING
下载PDF
Ultrasound Scanning Competencies in Midwifery Education in Zambia: Findings from a Desk Review and Needs Assessment
5
作者 Mutinke Zulu Sebean Mayimbo Patricia Katowa-Mukwato 《Health》 2024年第6期535-552,共18页
Introduction: Ultrasound is an essential component of antenatal care. Midwives provide most of the antenatal care but they do not perform ultrasound as it has been beyond their scope of practice. This leaves many wome... Introduction: Ultrasound is an essential component of antenatal care. Midwives provide most of the antenatal care but they do not perform ultrasound as it has been beyond their scope of practice. This leaves many women in Low and Middle-Income Countries without access to ultrasound scanning. The aim of this study was to identify competencies in ultrasound scanning in midwifery education. Methods: A desk review and needs assessment were conducted between July and October 2023. Articles and curricula on the internet, Google scholar and PubMed were searched for content on ultrasound scanning competencies. A Google form consisting of 20 questions was administered via email and WhatsApp to 135 participants. Descriptive statistics were used to analyse data. Results: The desk review showed that it is feasible to train midwives in ultrasound scanning. The training programs for midwives in obstetric ultrasound were conducted for 1 week to 3 months with most of them running for 4 weeks. Content included introduction to general principles of ultrasound, physics, basic knowledge in embryology, obstetrics, anatomy, measuring foetal biometry, estimating amniotic fluid and gestational age. Experts like sonographers trained midwives. Theory and hands on were the teaching methods used. Written and practical assessments were conducted. Needs assessment revealed that majority of participants 71 (53%) knew about basic ultrasound training for midwives. All participants (100%) said it is necessary to train midwives in basic ultrasound scan in Zambia. Some content should include, anatomy, measuring foetal biometry, assessing amniotic fluid level, and gestational age determination. Most participants 91 (67%) suggested that the appropriate duration of training is 4 - 6 weeks. Conclusion: Empowering every midwife with ultrasound scanning skills will enable early detection of any abnormality among pregnant women and prompt intervention to save lives. 展开更多
关键词 Ultrasound scanning Midwifery Education Competencies
下载PDF
Investigation of reflection anisotropy induced by micropipe defects on the surface of a 4H-SiC single crystal using scanning anisotropy microscopy
6
作者 黄威 俞金玲 +7 位作者 刘雨 彭燕 王利军 梁平 陈堂胜 徐现刚 刘峰奇 陈涌海 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期630-637,共8页
Optical reflection anisotropy microscopy mappings of micropipe defects on the surface of a 4H-SiC single crystal are studied by the scanning anisotropy microscopy(SAM)system.The reflection anisotropy(RA)image with a&#... Optical reflection anisotropy microscopy mappings of micropipe defects on the surface of a 4H-SiC single crystal are studied by the scanning anisotropy microscopy(SAM)system.The reflection anisotropy(RA)image with a'butterfly pattern'is obtained around the micropipes by SAM.The RA image of the edge dislocations is theoretically simulated based on dislocation theory and the photoelastic principle.By comparing with the Raman spectrum,it is verified that the micropipes consist of edge dislocations.The different patterns of the RA images are due to the different orientations of the Burgers vectors.Besides,the strain distribution of the micropipes is also deduced.One can identify the dislocation type,the direction of the Burgers vector and the optical anisotropy from the RA image by using SAM.Therefore,SAM is an ideal tool to measure the optical anisotropy induced by the strain field around a defect. 展开更多
关键词 scanning anisotropy microscopy SiC reflection anisotropy edge dislocation
下载PDF
Prophylactic Pattern Scanning Laser Retinal Photocoagulation for Diabetic Retinopathy in Spontaneously Diabetic Torii Fatty Rats: Preliminary Experimental Results
7
作者 Rina Takagi Yoshiaki Tanaka +6 位作者 Tetsuya Hasegawa Masami Shinohara Yasushi Kageyama Tomohiko Sasase Machiko Shimmura-Tomita Akihiro Kakehashi Toshikatsu Kaburaki 《Journal of Diabetes Mellitus》 CAS 2024年第3期153-165,共13页
Research Background and Purpose: The number of diabetic patients is rapidly increasing, making it crucial to find methods to prevent diabetic retinopathy (DR), a leading cause of blindness. We investigated the effects... Research Background and Purpose: The number of diabetic patients is rapidly increasing, making it crucial to find methods to prevent diabetic retinopathy (DR), a leading cause of blindness. We investigated the effects of prophylactic pattern scanning laser retinal photocoagulation on DR development in Spontaneously Diabetic Torii (SDT) fatty rats as a new prevention approach. Methods: Photocoagulation was applied to the right eyes of 8-week-old Spontaneously Diabetic Torii (SDT) fatty rats, with the left eyes serving as untreated controls. Electroretinography at 9 and 39 weeks of age and pathological examinations, including immunohistochemistry for vascular endothelial growth factor and glial fibrillary acidic protein at 24 and 40 weeks of age, were performed on both eyes. Results: There were no significant differences in amplitude and prolongation of the OP waves between the right and left eyes in SDT fatty rats at 39 weeks of age. Similarly, no significant differences in pathology and immunohistochemistry were observed between the right and left eyes in SDT fatty rats at 24 and 40 weeks of age. Conclusion: Prophylactic pattern scanning retinal laser photocoagulation did not affect the development of diabetic retinopathy in SDT fatty rats. 展开更多
关键词 Diabetes Pattern scanning Laser Diabetic Retinopathy Spontaneously Diabetic Torii Fatty Rats ELECTRORETINOGRAPHY
下载PDF
Uniformity Control of Scanned Beam in 300 MeV Proton and Heavy Ion Accelerator Complex at SESRI
8
作者 HOU Lingxiao YUAN Youjin +10 位作者 SHEN Guodong RUAN Shuang LIU Jie ZHU Yunpeng WANG Geng GUO Hongliang LYU Mingbang GAO Daqing XU Zhiguo SHENG Lina YANG Jiancheng 《原子能科学技术》 EI CAS CSCD 北大核心 2024年第4期705-713,共9页
In recent years,heavy ion accelerator technology has been rapidly developing worldwide and widely applied in the fields of space radiation simulation and particle therapy.Usually,a very high uniformity in the irradiat... In recent years,heavy ion accelerator technology has been rapidly developing worldwide and widely applied in the fields of space radiation simulation and particle therapy.Usually,a very high uniformity in the irradiation area is required for the extracted ion beams,which is crucial because it directly affects the experimental precision and therapeutic effect.Specifically,ultra-large-area and high-uniformity scanning are crucial requirements for spacecraft radiation effects assessment and serve as core specification for beamline terminal design.In the 300 MeV proton and heavy ion accelerator complex at the Space Environment Simulation and Research Infrastructure(SESRI),proton and heavy ion beams will be accelerated and ultimately delivered to three irradiation terminals.In order to achieve the required large irradiation area of 320 mm×320 mm,horizontal and vertical scanning magnets are used in the extraction beam line.However,considering the various requirements for beam species and energies,the tracking accuracy of power supplies(PSs),the eddy current effect of scanning magnets,and the fluctuation of ion bunch structure will reduce the irradiation uniformity.To mitigate these effects,a beam uniformity optimization method based on the measured beam distribution was proposed and applied in the accelerator complex at SESRI.In the experiment,the uniformity is successfully optimized from 75%to over 90%after five iterations of adjustment to the PS waveforms.In this paper,the method and experimental results were introduced. 展开更多
关键词 heavy ion accelerator beam uniformity scanning magnet MIC
下载PDF
Accuracy of tree mapping based on hand-held laser scanning comparing leaf-on and leaf-off conditions in mixed forests
9
作者 Frederico Tupinambá-Simões Adrián Pascual +3 位作者 Juan Guerra-Hernández Cristóbal Ordóñez Tiago de Conto Felipe Bravo 《Journal of Forestry Research》 SCIE EI CAS CSCD 2024年第5期14-25,共12页
The use of mobile laser scanning to survey forest ecosystems is a promising,scalable technology to describe forest 3D structures at high resolution.To confirm the con-sistency in the retrieval of forest structural par... The use of mobile laser scanning to survey forest ecosystems is a promising,scalable technology to describe forest 3D structures at high resolution.To confirm the con-sistency in the retrieval of forest structural parameters using hand-held laser scanning(HLS),before operationalizing the method,confirming the data is crucial.We analyzed the per-formance of tree-level mapping based on HLS under differ-ent phenology conditions on a mixed forest in western Spain comprising Pinus pinaster and two deciduous species,Alnus glutinosa and Quercus pyrenaica.The area was surveyed twice during the growing season(July 2022)and once in the deciduous season(February 2022)using several scan-ning paths.Ground reference data(418 trees,15 snags)was used to calibrate the HLS data and to assess the influence of phenology when converting 3D data into tree-level attrib-utes(DBH,height and volume).The HLS-based workflow was robust at isolating tree positions and recognizing stems despite changes in phenology.Ninety-six percent of all pairs matched below 65 cm.For DBH,phenology barely altered estimates.We observed a strong agreement when comparing HLS-based tree height distributions.The values exceeded 2 m when comparing height measurements,confirming height data should be carefully used as reference in remote sensing-based inventories,especially for deciduous species.Tree volume was more precise for pines(r=0.95,and rela-tive RMSE=21.3–23.8%)compared to deciduous species(r=0.91–0.96,and relative RMSE=27.3–30.5%).HLS data and the forest structural complexity tool performed remark-ably,especially in tree positioning considering mixed forests and mixed phenology conditions. 展开更多
关键词 Precision forestry Forest monitoring Mobile laser scanning Forest inventory
下载PDF
A review of understanding electrocatalytic reactions in energy conversion and energy storage systems via scanning electrochemical microscopy
10
作者 Jihye Park Jong Hwan Lim +4 位作者 Jin-Hyuk Kang Jiheon Lim Ho Won Jang Hosun Shin Sun Hwa Park 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第4期155-177,共23页
To address climate change and promote environmental sustainability,electrochemical energy conversion and storage systems emerge as promising alternative to fossil fuels,catering to the escalating demand for energy.Ach... To address climate change and promote environmental sustainability,electrochemical energy conversion and storage systems emerge as promising alternative to fossil fuels,catering to the escalating demand for energy.Achieving optimal energy efficiency and cost competitiveness in these systems requires the strategic design of electrocatalysts,coupled with a thorough comprehension of the underlying mechanisms and degradation behavior occurring during the electrocatalysis processes.Scanning electrochemical microscopy(SECM),an analytical technique for studying surface electrochemically,stands out as a powerful tool offering electrochemical insights.It possesses remarkable spatiotemporal resolution,enabling the visualization of the localized electrochemical activity and surface topography.This review compiles crucial research findings and recent breakthroughs in electrocatalytic processes utilizing the SECM methodology,specifically focusing on applications in electrolysis,fuel cells,and metal–oxygen batteries within the realm of energy conversion and storage systems.Commencing with an overview of each energy system,the review introduces the fundamental principles of SECM,and aiming to provide new perspectives and broadening the scope of applied research by describing the major research categories within SECM. 展开更多
关键词 scanning electrochemical microscopy ELECTROCATALYST ELECTROCATALYSIS Water splitting Fuel cell Metal-oxygen battery
下载PDF
Imaging of human parafoveal area with large field of view in adaptive optics line scanning ophthalmoscope
11
作者 Wen Kong Yiwei Chen +1 位作者 Guohua Shi Yi He 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第6期41-51,共11页
The parafoveal area,with its high concentration of photoreceptors andfine retinal capillaries,is crucial for central vision and often exhibits early signs of pathological changes.The current adaptive optics scanning l... The parafoveal area,with its high concentration of photoreceptors andfine retinal capillaries,is crucial for central vision and often exhibits early signs of pathological changes.The current adaptive optics scanning laser ophthalmoscope(AOSLO)provides an excellent tool to acquire accurate and detailed information about the parafoveal area with cellular resolution.However,limited by the scanning speed of two-dimensional scanning,thefield of view(FOV)in the AOSLO system was usually less than or equal to 2,and the stitching for the parafoveal area required dozens of images,which was time-consuming and laborious.Unfortunately,almost half of patients are unable to obtain stitched images because of their poorfixation.To solve this problem,we integrate AO technology with the line-scan imaging method to build an adaptive optics line scanning ophthalmoscope(AOLSO)system with a larger FOV.In the AOLSO,afocal spherical mirrors in pairs are nonplanar arranged and the distance and angle between optical elements are optimized to minimize the aberrations,two cylinder lenses are orthogonally placed before the imaging sensor to stretch the point spread function(PSF)for sufficiently digitizing light energy.Captured human retinal images show the whole parafoveal area with 55FOV,60 Hz frame rate and cellular resolutions.Take advantage of the 5FOV of the AOLSO,only 9 frames of the retina are captured with several minutes to stitch a montage image with an FOV of 99,in which photoreceptor counting is performed within approximately 5eccentricity.The AOLSO system not only provides cellular resolution but also has the capability to capture the parafoveal region in a single frame,which offers great potential for noninvasive studying of the parafoveal area. 展开更多
关键词 Adaptive optics line scanning retinal imaging system parafoveal capillary vasculature.
下载PDF
Influence of pore structure heterogeneity on channeling channels during hot water flooding in heavy oil reservoir based on CT scanning
12
作者 Qing-Jun Du Hao-Yu Zheng +3 位作者 Jian Hou Yong-Ge Liu Jian-Fang Sun Dong Zhao 《Petroleum Science》 SCIE EI CAS CSCD 2024年第4期2407-2419,共13页
Hot water flooding is an effective way to develop heavy oil reservoirs.However,local channeling channels may form,possibly leading to a low thermal utilization efficiency and high water cut in the reservoir.The pore s... Hot water flooding is an effective way to develop heavy oil reservoirs.However,local channeling channels may form,possibly leading to a low thermal utilization efficiency and high water cut in the reservoir.The pore structure heterogeneity is an important factor in forming these channels.This study proposes a method that mixes quartz sand with different particle sizes to prepare weakly heterogeneous and strongly heterogeneous models through which hot water flooding experiments are conducted.During the experiments,computer tomography(CT)scanning identifies the pore structure and micro remaining oil saturation distribution to analyze the influence of the pore structure heterogeneity on the channeling channels.The oil saturation reduction and average pore size are divided into three levels to quantitatively describe the relationship between the channeling channel distribution and pore structure heterogeneity.The zone where oil saturation reduction exceeds 20%is defined as a channeling channel.The scanning area is divided into 180 equally sized zones based on the CT scanning images,and threedimensional(3D)distributions of the channeling channels are developed.Four micro remaining oil distribution patterns are proposed,and the morphology characteristics of micro remaining oil inside and outside the channeling channels are analyzed.The results show that hot water flooding is more balanced in the weakly heterogeneous model,and the oil saturation decreases by more than 20%in most zones without narrow channeling channels forming.In the strongly heterogeneous model,hot water flooding is unbalanced,and three narrow channeling channels of different lengths form.In the weakly heterogeneous model,the oil saturation reduction is greater in zones with larger pores.The distribution range of the average pore size is larger in the strongly heterogeneous model.The network remaining oil inside the channeling channels is less than outside the channeling channels,and the hot water converts the network remaining oil into cluster,film,and droplet remaining oil. 展开更多
关键词 Heavy oil Hot water flooding Pore structure Channeling channels CT scanning
下载PDF
Fatigue properties and damage constitutive model of salt rock based on CT scanning
13
作者 Junbao Wang Xiao Liu +3 位作者 Qiang Zhang Xinrong Liu Zhanping Song Shijin Feng 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2024年第2期245-259,共15页
To investigate the macroscopic fatigue properties and the mesoscopic pore evolution characteristics of salt rock under cyclic loading,fatigue tests under different upper-limit stresses were carried out on salt rock,an... To investigate the macroscopic fatigue properties and the mesoscopic pore evolution characteristics of salt rock under cyclic loading,fatigue tests under different upper-limit stresses were carried out on salt rock,and the mesoscopic pore structures of salt rock before and after fatigue tests and under different cycle numbers were measured using CT scanning instrument.Based on the test results,the effects of the cycle number and the upper-limit stress on the evolution of cracks,pore morphology,pore number,pore volume,pore size,plane porosity,and volume porosity of salt rock were analyzed.The failure path of salt rock specimens under cyclic loading was analyzed using the distribution law of plane porosity.The damage variable of salt rock under cyclic loading was defined on basis of the variation of volume porosity with cycle number.In order to describe the fatigue deformation behavior of salt rock under cyclic loading,the nonlinear Burgers damage constitutive model was further established.The results show that the model established can better reflect the whole development process of fatigue deformation of salt rock under cyclic loading. 展开更多
关键词 Salt rock Cyclic loading CT scanning Mesoscopic pore evolution Constitutive model
下载PDF
Assessing the dynamics of O_(2) desorption from cobalt phthalocyanine by in situ electrochemical scanning tunneling microscopy
14
作者 Yu-Qi Wang Yue Feng +1 位作者 Xiang Wang Dong Wang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第11期144-148,共5页
We report here the in situ electrochemical scanning tunneling microscopy(ECSTM) study of cobalt phthalocyanine(CoPc)-catalyzed O_(2) evolution reaction(OER) and the dynamics of CoPc-O_(2) dissociation.The self-assembl... We report here the in situ electrochemical scanning tunneling microscopy(ECSTM) study of cobalt phthalocyanine(CoPc)-catalyzed O_(2) evolution reaction(OER) and the dynamics of CoPc-O_(2) dissociation.The self-assembled CoPc monolayer is fabricated on Au(111) substrate and resolved by ECSTM in 0.1 M KOH electrolyte.The OH^(-)adsorption on CoPc prior to OER is observed in ECSTM images.During OER,the generated O_(2) adsorbed on Co Pc is observed in the CoPc monolayer.Potential step experiment is employed to monitor the desorption of OER-generated O_(2) from CoPc,which results in the decreasing surface coverage of CoPc-O_(2) with time.The rate constant of O_(2) desorption is evaluated through data fitting.The insights into the dynamics of Co-O_(2) dissociation at the molecular level via in situ imaging help understand the role of Co-O_(2) in oxygen reduction reaction(ORR) and OER. 展开更多
关键词 Electrochemical scanning tunneling microscopy Oxygen evolution reaction Cobalt phthalocyanine
下载PDF
Contribution of CT Scanning in the Investigation of Cranioencephalic Lesions in Bangui
15
作者 Bangue Songrou Francky Kouandongui Timothée Mobima +5 位作者 Borel Tambala Yannick Héritier Sombot-Soule Stéphane Kouzou Judith Guiaba Kette Euloge Tapiade Bidan Richard Bazogo 《Open Journal of Radiology》 2024年第3期156-165,共10页
Introduction: Cranioencephalic exploration has always played a major role in CT scans. In the Central Africa Republic (CAR), the lack of cross-sectional imaging before the year 2020 meant that no study had focused on ... Introduction: Cranioencephalic exploration has always played a major role in CT scans. In the Central Africa Republic (CAR), the lack of cross-sectional imaging before the year 2020 meant that no study had focused on cranioencephalic lesions. The aim of this study was to contribute to improving the management of cranioencephalic pathologies in CAR. Patients and Method: The study took place at the Bangui National Medical Imaging Centre (CNIMB). It was a retrospective study over a two-year period (March 1, 2021 to February 30, 2023). All patients referred for cranioencephalic CT scans were included, regardless of age or sex. Results: 1745 CT scans were performed, 575 of which were cranioencephalic CT scans. The majority of patients were male (53%). Most lived in the capital Bangui (90.9%). Patients aged 61 and over were the most representative. The distribution of patients by requesting department showed that the reception and emergency department was one of the least requesting departments. The main abnormalities observed were strokes, 82.1% of which were ischaemic strokes and 17.9% haemorrhagic strokes. Strokes were followed by degenerative lesions. Post-traumatic injuries included haemorrhagic contusions (38.3%), subdural haematomas in 20.5% of cases, and extradural haematomas (9.3%). Craniofacial lesions (fractures) were observed in 45.8% of cases. Conclusion: Cranioencephalic scans accounted for 1/3 of CT examinations performed during the study period. It revealed pathologies that could not be detected by conventional means. All in all, CT scans contributed to the diagnosis of cerebral pathologies. 展开更多
关键词 Cranioencephalic scan National Medical Imaging Centre Bangui
下载PDF
Study on Joint Method of 3D Acoustic Emission Source Localization Simplex and Grid Search Scanning
16
作者 Liu Wei-jian Wang Hao-nan +4 位作者 Xiao Yang Hou Meng-jie Dong Sen-sen Zhang Zhi-zeng Lu Gao-ming 《Applied Geophysics》 SCIE CSCD 2024年第3期456-467,617,共13页
Acoustic emission(AE)source localization is a fundamental element of rock fracture damage imaging.To improve the efficiency and accuracy of AE source localization,this paper proposes a joint method comprising a three-... Acoustic emission(AE)source localization is a fundamental element of rock fracture damage imaging.To improve the efficiency and accuracy of AE source localization,this paper proposes a joint method comprising a three-dimensional(3D)AE source localization simplex method and grid search scanning.Using the concept of the geometry of simplexes,tetrahedral iterations were first conducted to narrow down the suspected source region.This is followed by a process of meshing the region and node searching to scan for optimal solutions,until the source location is determined.The resulting algorithm was tested using the artificial excitation source localization and uniaxial compression tests,after which the localization results were compared with the simplex and exhaustive methods.The results revealed that the localization obtained using the proposed method is more stable and can be effectively avoided compared with the simplex localization method.Furthermore,compared with the global scanning method,the proposed method is more efficient,with an average time of 10%–20%of the global scanning localization algorithm.Thus,the proposed algorithm is of great significance for laboratory research focused on locating rupture damages sustained by large-sized rock masses or test blocks. 展开更多
关键词 acoustic emission simplex form grid search scan locating the epicenter
下载PDF
Algorithm of automatic identification of diabetic retinopathy foci based on ultra-widefield scanning laser ophthalmoscopy
17
作者 Jie Wang Su-Zhen Wang +7 位作者 Xiao-Lin Qin Meng Chen Heng-Ming Zhang Xin Liu Meng-Jun Xiang Jian-Bin Hu Hai-Yu Huang Chang-Jun Lan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期610-615,共6页
AIM:To propose an algorithm for automatic detection of diabetic retinopathy(DR)lesions based on ultra-widefield scanning laser ophthalmoscopy(SLO).METHODS:The algorithm utilized the FasterRCNN(Faster Regions with CNN ... AIM:To propose an algorithm for automatic detection of diabetic retinopathy(DR)lesions based on ultra-widefield scanning laser ophthalmoscopy(SLO).METHODS:The algorithm utilized the FasterRCNN(Faster Regions with CNN features)+ResNet50(Residua Network 50)+FPN(Feature Pyramid Networks)method for detecting hemorrhagic spots,cotton wool spots,exudates,and microaneurysms in DR ultra-widefield SLO.Subimage segmentation combined with a deeper residual network FasterRCNN+ResNet50 was employed for feature extraction to enhance intelligent learning rate.Feature fusion was carried out by the feature pyramid network FPN,which significantly improved lesion detection rates in SLO fundus images.RESULTS:By analyzing 1076 ultra-widefield SLO images provided by our hospital,with a resolution of 2600×2048 dpi,the accuracy rates for hemorrhagic spots,cotton wool spots,exudates,and microaneurysms were found to be 87.23%,83.57%,86.75%,and 54.94%,respectively.CONCLUSION:The proposed algorithm demonstrates intelligent detection of DR lesions in ultra-widefield SLO,providing significant advantages over traditional fundus color imaging intelligent diagnosis algorithms. 展开更多
关键词 diabetic retinopathy ultra-widefield scanning laser ophthalmoscopy intelligent diagnosis system
下载PDF
Characterization of tumors of jaw:Additive value of contrast enhancement and dual-energy computed tomography
18
作者 Deepak Justine Viswanathan Ashu Seith Bhalla +3 位作者 Smita Manchanda Ajoy Roychoudhury Deepika Mishra Asit Ranjan Mridha 《World Journal of Radiology》 2024年第4期82-93,共12页
BACKGROUND Currently,the differentiation of jaw tumors is mainly based on the lesion’s morphology rather than the enhancement characteristics,which are important in the differentiation of neoplasms across the body.Th... BACKGROUND Currently,the differentiation of jaw tumors is mainly based on the lesion’s morphology rather than the enhancement characteristics,which are important in the differentiation of neoplasms across the body.There is a paucity of literature on the enhancement characteristics of jaw tumors.This is mainly because,even though computed tomography(CT)is used to evaluate these lesions,they are often imaged without intravenous contrast.This study hypothesised that the enhancement characteristics of the solid component of jaw tumors can aid in the differentiation of these lesions in addition to their morphology by dual-energy CT,therefore improving the ability to differentiate between various pathologies.AIM To evaluate the role of contrast enhancement and dual-energy quantitative parameters in CT in the differentiation of jaw tumors.METHODS Fifty-seven patients with jaw tumors underwent contrast-enhanced dual-energy CT.Morphological analysis of the tumor,including the enhancing solid component,was done,followed by quantitative analysis of iodine concentration(IC),water concentration(WC),HU,and normalized IC.The study population was divided into four subgroups based on histopathological analysis-central giant cell granuloma(CGCG),ameloblastoma,odontogenic keratocyst(OKC),and other jaw tumors.A one-way ANOVA test for parametric variables and the Kruskal-Wallis test for nonparametric variables were used.If significant differences were found,a series of independent t-tests or Mann-Whitney U tests were used.RESULTS Ameloblastoma was the most common pathology(n=20),followed by CGCG(n=11)and OKC.CGCG showed a higher mean concentration of all quantitative parameters than ameloblastomas(P<0.05).An IC threshold of 31.35×100μg/cm^(3) had the maximum sensitivity(81.8%)and specificity(65%).Between ameloblastomas and OKC,the former showed a higher mean concentration of all quantitative parameters(P<0.001),however when comparing unilocular ameloblastomas with OKCs,the latter showed significantly higher WC.Also,ameloblastoma had a higher IC and lower WC compared to“other jaw tumors”group.CONCLUSION Enhancement characteristics of solid components combined with dual-energy parameters offer a more precise way to differentiate between jaw tumors. 展开更多
关键词 Jaw neoplasms Ameloblastomas dual-energy computed tomography Iodine quantification Mandibular neoplasms Maxillary neoplasms
下载PDF
Assessment of Dose and Lifetime Risk of Exposure Induced Cancer in Adult Common Computed Tomography Scans in Douala-Cameroon
19
作者 Celestin Mpeke Mokubangele Alexandre Ngwa Ebongue +1 位作者 Daniel Bongue Boniface Moifo 《Open Journal of Radiology》 2024年第3期135-146,共12页
Background: Among medical technologies that use ionizing radiation, CT is currently the radio diagnostic technic that can deliver the highest radiation to the Patient compared with other conventional procedures. In de... Background: Among medical technologies that use ionizing radiation, CT is currently the radio diagnostic technic that can deliver the highest radiation to the Patient compared with other conventional procedures. In developing countries, the uses and risks of CT have not been well characterized. Objective: To estimate the lifetime attributable risk (LAR) incidence and mortality for cancer for each procedure for adult’s patients who had Computed Tomography examinations in 10 imaging centers in the city of Douala-Cameroon so as to provide a reference data. Materials and Methods: We conducted a cross-sectional study describing radiation dose associated with the 8 most common types of diagnostic CT studies performed on 1287 consecutive adult patients at 10 Douala radiology department. We estimated lifetime attributable risks of cancer by study type from these measured doses. Estimation of LAR for cancer incidence and mortality was based on the effective dose, patient’s sex and age at exposure using the BIER VII preferred models. Results: Mean effective dose from CT scans examinations varied from: 0.30 and 8.81 mSv. The highest doses were observed for lumbar spine CT (8.81 mSv), followed by abdomen-pelvis procedure (6.46 mSv), chest-abdomen-pelvic CT (6.61 mSv), chest CT (3.90 mSv), cervical Spine CT (3.05 mSv), head CT (1.7 mSv) and lower for sinus CT (0.30 mSv). The LAR values of all cancer from patients’ CT scans obtained vary from 67.13 excess per 100,000 (about 1 in 1489) and 0.45 excess per 100,000 (about 1 in 222,222). All cancer risk was high for lumbar spine CT in women 20 years old (67.13 excess deaths in 100,000 scans) followed by chest-abdomen-pelvic CT (50.36 excess deaths in 100,000 scans) and abdomen-pelvic CT (49.22 excess deaths in 100,000 scans) for the same age group. The LAR of incidence and mortality values were higher from female’s patients than males and higher for younger than older patients. Conclusion: This study was set out to estimate the LAR values associated with adult common CT scans procedures. The data indicates, LAR risks related to induced cancer from CT exposures were estimated to be low. This risk can be relatively significant for younger age group compared to older age group. The LAR values obtained will help to better evaluate radiation exposure risk, before ordering a CT scans examinations. 展开更多
关键词 Patient Dose CT scan BEIIR VII Report Cancer Risk Assessment
下载PDF
Phase behavior of gas condensate in porous media using real-time computed tomography scanning
20
作者 Wen-Long Jing Lei Zhang +5 位作者 Ai-Fen Li Jun-Jie Zhong Hai Sun Yong-Fei Yang Yu-Long Cheng Jun Yao 《Petroleum Science》 SCIE EI CAS CSCD 2024年第2期1032-1043,共12页
The phase behavior of gas condensate in reservoir formations differs from that in pressure-volume-temperature(PVT)cells because it is influenced by porous media in the reservoir formations.Sandstone was used as a samp... The phase behavior of gas condensate in reservoir formations differs from that in pressure-volume-temperature(PVT)cells because it is influenced by porous media in the reservoir formations.Sandstone was used as a sample to investigate the influence of porous media on the phase behavior of the gas condensate.The pore structure was first analyzed using computed tomography(CT)scanning,digital core technology,and a pore network model.The sandstone core sample was then saturated with gas condensate for the pressure depletion experiment.After each pressure-depletion state was stable,realtime CT scanning was performed on the sample.The scanning results of the sample were reconstructed into three-dimensional grayscale images,and the gas condensate and condensate liquid were segmented based on gray value discrepancy to dynamically characterize the phase behavior of the gas condensate in porous media.Pore network models of the condensate liquid ganglia under different pressures were built to calculate the characteristic parameters,including the average radius,coordination number,and tortuosity,and to analyze the changing mechanism caused by the phase behavior change of the gas condensate.Four types of condensate liquid(clustered,branched,membranous,and droplet ganglia)were then classified by shape factor and Euler number to investigate their morphological changes dynamically and elaborately.The results show that the dew point pressure of the gas condensate in porous media is 12.7 MPa,which is 0.7 MPa higher than 12.0 MPa in PVT cells.The average radius,volume,and coordination number of the condensate liquid ganglia increased when the system pressure was between the dew point pressure(12.7 MPa)and the pressure for the maximum liquid dropout,Pmax(10.0 MPa),and decreased when it was below Pmax.The volume proportion of clustered ganglia was the highest,followed by branched,membranous,and droplet ganglia.This study provides crucial experimental evidence for the phase behavior changing process of gas condensate in porous media during the depletion production of gas condensate reservoirs. 展开更多
关键词 Gas condensate Pressure depletion Real-time micro-computed tomography scanning Distribution of condensate liquid
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部