期刊文献+
共找到54篇文章
< 1 2 3 >
每页显示 20 50 100
Computation of satellite clock-ephemeris augmentation parameters for dual-frequency multi-constellation satellite-based augmentation system 被引量:2
1
作者 CHEN Jie HUANG Zhigang LI Rui 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2018年第6期1111-1123,共13页
Dual-frequency multi-constellation(DFMC) satellitebased augmentation system(SBAS) does not broadcast fast correction, which is important in reducing range error in L1-only SBAS.Meanwhile, the integrity bound of a sate... Dual-frequency multi-constellation(DFMC) satellitebased augmentation system(SBAS) does not broadcast fast correction, which is important in reducing range error in L1-only SBAS.Meanwhile, the integrity bound of a satellite at low elevation is so loose that the service availability is decreased near the boundary of the service area. Therefore, the computation of satellite clockephemeris(SCE) augmentation parameters needs improvement.We propose a method introducing SCE prediction to eliminate most of the SCE error resulting from global navigation satellite system GNSS broadcast message. Compared with the signal-inspace(SIS) after applying augmentation parameters broadcast by the wide area augmentation system(WAAS), SIS accuracy after applying augmentation parameters computed by the proposed algorithm is improved and SIS integrity is ensured. With global positioning system(GPS) only, the availability of category-I(CAT-I)with a vertical alert level of 15 m in continental United States is about 90%, while the availability in the other part of the WAAS service area is markedly improved. With measurements made by the stations from the crustal movement observation network of China,users in some part of China can obtain CAT-I(vertical alert limit is 15 m) service with GPS and global navigation satellite system(GLONASS). 展开更多
关键词 dual-frequency multi-constellation(DFMC) satellitebased augmentation system(SBAS) orbit determination integrity
下载PDF
Understanding the spatial interaction of ultrasounds based on three-dimensional dual-frequency ultrasonic field numerical simulation
2
作者 Zhao-yang Yin Qi-chi Le +3 位作者 Yan-chao Jiang Da-zhi Zhao Qi-yu Liao Qi Zou 《China Foundry》 SCIE EI CAS CSCD 2024年第1期29-43,共15页
A transient 3D model was established to investigate the effect of spatial interaction of ultrasounds on the dual-frequency ultrasonic field in magnesium alloy melt.The effects of insertion depth and tip shape of the u... A transient 3D model was established to investigate the effect of spatial interaction of ultrasounds on the dual-frequency ultrasonic field in magnesium alloy melt.The effects of insertion depth and tip shape of the ultrasonic rods,input pressures and their ratio on the acoustic field distribution were discussed in detail.Additionally,the spacing,angle,and insertion depth of two ultrasonic rods significantly affect the interaction between distinct ultrasounds.As a result,various acoustic pressure distributions and cavitation regions are obtained.The spherical rods mitigate the longitudinal and transversal attenuation of acoustic pressure and expand the cavitation volume by 53.7%and 31.7%,respectively,compared to the plate and conical rods.Increasing the input pressure will enlarge the cavitation region but has no effect on the acoustic pressure distribution pattern.The acoustic pressure ratio significantly affects the pressure distribution and the cavitation region,and the best cavitation effect is obtained at the ratio of 2:1(P15:P20). 展开更多
关键词 dual-frequency ultrasonic numerical model acoustic pressure spatial interaction magnesium alloy
下载PDF
Design and preliminary test of a 105/140 GHz dual-frequency MW-level gyrotron 被引量:3
3
作者 胡林林 孙迪敏 +11 位作者 黄麒力 卓婷婷 马国武 蒋艺 龚胜刚 曾造金 郭子星 杜朝海 李繁宏 陈洪斌 孟凡宝 马弘舸 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第3期162-169,共8页
A dual-frequency(105/140 GHz)MW-level continuous-wave gyrotron was developed for fusion application at Institute of Applied Electronics,China Academy of Engineering Physics.This gyrotron employs a cylindrical cavity w... A dual-frequency(105/140 GHz)MW-level continuous-wave gyrotron was developed for fusion application at Institute of Applied Electronics,China Academy of Engineering Physics.This gyrotron employs a cylindrical cavity working in the TE18,7 mode at 105 GHz and the TE24,9 mode at 140 GHz.A triode magnetron injection gun and a built-in quasi-optical mode converter were designed to operate at these two frequencies.For the proof-test phase,the gyrotron was equipped with a single-disk boron nitride window to achieve radio frequency output with a power of~500 k W for a short-pulse duration.In the preliminary short-pulse proof-test in the first quarter of2021,the dual-frequency gyrotron achieved output powers of 300 k W at 105 GHz and 540 k W at140 GHz,respectively,under 5 Hz 1 ms continuous pulse-burst operations.Power upgrade and pulse-width extension were hampered by the limitation of the high-voltage power supply and output window.This gyrotron design was preliminarily validated. 展开更多
关键词 GYROTRON MEGAWATT plasma heating fusion application dual-frequency
下载PDF
Analytical Expressions of Dual-Frequency Plasma Diagnostic Theory 被引量:3
4
作者 程立 时家明 许波 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第1期37-39,共3页
Based on the fundamental ideas concerning microwave attenuation in plasma, we obtain a new expression of transmission attenuation of microwaves as a function of the incident wave frequency. And with reasonable hypothe... Based on the fundamental ideas concerning microwave attenuation in plasma, we obtain a new expression of transmission attenuation of microwaves as a function of the incident wave frequency. And with reasonable hypothesis, analytical forms of the electron density and the electron-neutral collision frequency are derived from the equations of the transmission attenuation of microwaves at two near frequencies. This method gives an effective and easy approach to diagnose the unmagnetized plasma. 展开更多
关键词 PLASMA diagnosis dual-frequency ATTENUATION electron density electron-neutral collision frequency
下载PDF
Optical feedback characteristics in a dual-frequency laser during laser cavity tuning 被引量:2
5
作者 刘刚 张书练 +1 位作者 李岩 朱钧 《Chinese Physics B》 SCIE EI CAS CSCD 2005年第10期1984-1989,共6页
The optical feedback characteristics in a Zeeman-birefringence dual-frequency laser are studied during the laser cavity tuning in three different kinds of optical feedback conditions: (i) only //-light is fed back;... The optical feedback characteristics in a Zeeman-birefringence dual-frequency laser are studied during the laser cavity tuning in three different kinds of optical feedback conditions: (i) only //-light is fed back; (ii) only ⊥-light is fed back; (iii) both lights are fed back. A compact displacement sensor is designed using the experimental result that there is a nearly 90 degrees phase delay between the two lights' cosine optical feedback signals when both lights are fed back into the laser cavity. The priority order that the two lights' intensity curves appear can be used for direction discrimination. The resolution of the displacement sensor is at least 79 rim, and the sensor can discriminate the target's moving direction easily. 展开更多
关键词 dual-frequency laser optical feedback SELF-MIXING displacement sensor
下载PDF
DEFORMATION MEASUREMENT USING DUAL-FREQUENCY PROJECTION GRATING PHASE-SHIFT PROFILOMETRY 被引量:2
6
作者 Yanming Chen Yuming He Eryi Hu Hongmao Zhu 《Acta Mechanica Solida Sinica》 SCIE EI 2008年第2期110-115,共6页
2π phase ambiguity problem is very important in phase measurement when a deformed object has a large out of plane displacement. The dual-frequency projection grating phaseshifting profilometry (PSP) can be used to ... 2π phase ambiguity problem is very important in phase measurement when a deformed object has a large out of plane displacement. The dual-frequency projection grating phaseshifting profilometry (PSP) can be used to solve such an issue. In the measurement, two properchosen frequency gratings are utilized to synthesize an equivalent wavelength grating which ensures the computed phase in a principal phase range. Thus, the error caused by the phase unwrapping process with the conventional phase reconstruct algorithm can be eliminated. Finally, experimental result of a specimen with large plastic deformation is given to prove that the proposed method is effective to handle the phase discontinuity. 展开更多
关键词 dual-frequency phase-shift profilometry projection grating phase unwrapping DEFORMATION
下载PDF
Difference-frequency ultrasound generation from microbubbles under dual-frequency excitation 被引量:1
7
作者 马青玉 邱媛媛 +2 位作者 黄蓓 章东 龚秀芬 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第9期437-442,共6页
The difference-frequency (DF) ultrasound generated by using parametric effect promises to improve detection depth owing to its low attenuation, which is beneficial for deep tissue imaging. With ultrasound contrast a... The difference-frequency (DF) ultrasound generated by using parametric effect promises to improve detection depth owing to its low attenuation, which is beneficial for deep tissue imaging. With ultrasound contrast agents infusion, the harmonic components scattered from the microbubbles, including DF, can be generated due to the nonlinear vibration. A theoretical study on the DF generation from microbubbles under the dual-frequency excitation is proposed in formula based on the solution of the RPNNP equation. The optimisation of the DF generation is discussed associated with the applied acoustic pressure, frequency, and the microbubble size. Experiments are performed to validate the theoretical predictions by using a dual-frequency signal to excite microbubbles. Both the numerical and experimental results demonstrate that the optimised DF ultrasound can be achieved as the difference frequency is close to the resonance frequency of the microbubble and improve the contrast-to-tissue ratio in imaging. 展开更多
关键词 difference-frequency MICROBUBBLE dual-frequency excitation parametric effect
下载PDF
Effect of Low-frequency Power on F, CF_2 Relative Density and F/CF_2 Ratio in Fluorocarbon Dual-Frequency Plasmas 被引量:1
8
作者 黄宏伟 叶超 +3 位作者 徐轶君 袁圆 施国峰 宁兆元 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第5期566-570,共5页
Effect of low-frequency power on F, CF2 relative density and F/CF2 ratio, in C2F6, C4F8 and CHF3 dual-frequency capacitively couple discharge driven by the power of 13.56 MHz/2 MHz, was investigated by using optical e... Effect of low-frequency power on F, CF2 relative density and F/CF2 ratio, in C2F6, C4F8 and CHF3 dual-frequency capacitively couple discharge driven by the power of 13.56 MHz/2 MHz, was investigated by using optical emission spectroscopy. High F, CF2 relative density and high F/CF2 ratio were obtained in a CHF3 plasma. But for C2F6 and C4Fs plasmas, the F, CF2 relative density and F/CF2 ratio all decreased significantly due to the difference in both reactive paths and reactive energy. The increase of LF power caused simultaneous increase of F and CF2 radical relative densities in C4Fs and CHF3 plasmas, but led to increase of F with the decrease in CF2 relative densities in C2F6 plasma due to the increase of lower energy electrons and the decrease of higher energy electrons in electron energy distribution function (EEDF). 展开更多
关键词 fluorocarbon plasma dual-frequency discharge low-k films etching
下载PDF
Improved Double-Probe Technique for Spatially Resolved Diagnosis of Dual-Frequency Capacitive Plasmas 被引量:1
9
作者 陆文琪 蒋相站 +6 位作者 刘永新 杨烁 张权治 李小松 徐勇 朱爱民 王友年 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第6期511-515,共5页
The conventional double-probe technique was improved with a combination of selfpowering and radio-frequency(RF) choking.RF perturbations in dual-frequency capacitively coupled discharge were effectively eliminated,a... The conventional double-probe technique was improved with a combination of selfpowering and radio-frequency(RF) choking.RF perturbations in dual-frequency capacitively coupled discharge were effectively eliminated,as judged by the disappearance of self-bias on the probes.The improved technique was tested by spatially resolved measurements of the electron temperature and ion density in both the axial and radial directions of a dual-frequency capacitive plasma.The measured data in the axial direction were compared with simulation results,and they were excellently consistent with each other.The measured radial distributions of the ion density and electron temperature were influenced significantly by the lower frequency(LF) power.It was shown that superposition of the lower frequency to the higher frequency(HF) power shifted the maximum ion density from the radial center to the edge region,while the trend for the electron temperature profile was the opposite.The changing feature of the ion density distribution is qualitatively consistent with that of the optical emission intensity reported. 展开更多
关键词 dual-frequency capacitive plasma double probe plasma diagnosis
下载PDF
Investigation of Capacitively Coupled Argon Plasma Driven by Dual-Frequency with Different Frequency Configurations 被引量:1
10
作者 虞一青 辛煜 +1 位作者 陆文琪 宁兆元 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第5期571-574,共4页
Low pressure argon dual-frequency (DF) capacitively coupled plasma (CCP) is generated by using different frequency configurations, such as 13.56/2, 27/2, 41/2, and 60/2 MHz. Characteristics of the plasma are inves... Low pressure argon dual-frequency (DF) capacitively coupled plasma (CCP) is generated by using different frequency configurations, such as 13.56/2, 27/2, 41/2, and 60/2 MHz. Characteristics of the plasma are investigated by using a floating double electrical probe and optical emission spectroscopy (OES). It is shown that in the DF-CCPs, the electron temperature Te decreases with the increase in exciting frequency, while the onset of 2 MHz induces a sudden increase in Te and the electron density increases basically with the increase in low frequency (LF) power. The intensity of 750.4 nm emission line increases with the LF power in the case of 13.56/2 MHz, while different tendencies of line intensity with the LF power appear for other configurations. The reason for this is also discussed. 展开更多
关键词 dual-frequency capacitively coupled plasma double probe optical emission spectroscopy
下载PDF
Effect of Discharge Parameters on Properties of Diamond-Like Carbon Films Prepared by Dual-Frequency Capacitively Coupled Plasma Source 被引量:1
11
作者 杨磊 辛煜 +2 位作者 徐海鹏 虞一青 宁兆元 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第1期53-58,共6页
Diamond-like carbon (DLC) films were prepared with CH4-Ar using a capacitively coupled plasma enhanced chemical vapor deposition (CCP-CVD) method driven by dual-frequency of 41 MHz and 13.56 MHz in combination. Du... Diamond-like carbon (DLC) films were prepared with CH4-Ar using a capacitively coupled plasma enhanced chemical vapor deposition (CCP-CVD) method driven by dual-frequency of 41 MHz and 13.56 MHz in combination. Due to a coupling via bulk plasma, the self-bias voltage depended not only on the radiofrequency (RF) power of the corresponding electrode but also on another RF power of the counter electrode. The influence of the discharge parameters on the deposition rate, optical and Raman properties of the deposited films was investigated. The optical band decreased basically with the increase in the input power of both the low frequency and high frequency. Raman measurements show that the deposited films have a maximal sp3 content with an applied negative self-bias voltage of -150 V, while high frequency power causes a continuous increase in the sp3 content. The measurement of atomic force microscope (AFM) shows that the surface of the deposited films under ion-bombardment becomes smoother than those with non-intended self-bias voltage. 展开更多
关键词 dual-frequency capacitively coupled discharge DLC Raman spectroscopy
下载PDF
Deposition of organosilicone thin film from hexamethyldisiloxane(HMDSO)with 50kHz/33MHz dual-frequency atmospheric-pressure plasma jet 被引量:1
12
作者 李娇娇 袁强华 +3 位作者 常小伟 王勇 殷桂琴 董晨钟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第4期92-98,共7页
The deposition of organosilicone thin films from hexamethyldisiloxane(HMDSO) by using a dual-frequency (50 kHz/33 MHz) atmospheric-pressure micro-plasma jet with an admixture of a small volume of HMDSO and Ar was ... The deposition of organosilicone thin films from hexamethyldisiloxane(HMDSO) by using a dual-frequency (50 kHz/33 MHz) atmospheric-pressure micro-plasma jet with an admixture of a small volume of HMDSO and Ar was investigated.The topography was measured by using scanning electron microscopy.The chemical bond and composition of these films were analyzed by Fourier transform infrared spectroscopy (FTIR) and x-ray photoelectron spectroscopy.The results indicated that the as-deposited film was constituted by silicon,carbon,and oxygen elements,and FTIR suggested the films are organosilicon with the organic component (-CHx) and hydroxyl functional group(-OH) connected to the Si-O-Si backbone.Thin-film hardness was recorded by an MH-5-VM Digital Micro-Hardness Tester.Radio frequency power had a strong impact on film hardness and the hardness increased with increasing power. 展开更多
关键词 organosilicone thin film HEXAMETHYLDISILOXANE dual-frequency atmospheric-pressureplasma jet
下载PDF
Effect of Low-Frequency Power on Etching Characteristics of 6H-SiC in C4F8/Ar Dual-Frequency Capacitively Coupled Plasma 被引量:1
13
作者 XU Yijun 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第10期1066-1070,共5页
Dry etching of 6H silicon carbide (6H-SiC) wafers in a C4Fs/Ar dual-frequency capacitively coupled plasma (DF-CCP) was investigated. Atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS) wer... Dry etching of 6H silicon carbide (6H-SiC) wafers in a C4Fs/Ar dual-frequency capacitively coupled plasma (DF-CCP) was investigated. Atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS) were used to measure the SiC surface structure and compositions, respectively. Optical emission spectroscopy (OES) was used to measure the relative concentration of F radicals in the plasma. It was found that the roughness of the etched SiC surface and the etching rate are directly related to the power of low-frequency (LF) source. At lower LF power, a smaller surface roughness and a lower etching rate are obtained due to weak bombardment of low energy ions on the SiC wafers. At higher LF power the etching rate can be efficiently increased, but the surface roughness increases too. Compared with other plasma dry etching methods, the DF-CCP can effectively inhibit CχFγ films' deposition, and reduce surface residues. 展开更多
关键词 SIC plasma etching dual-frequency capacitively coupled plasma X-ray photoelectron spectroscopy optical emission spectroscopy
下载PDF
The Performance of Dual-Frequency Polarimetric Scatterometer in Sea Surface Wind Retrieval
14
作者 LIU Shubo WEI Enbo +2 位作者 JIN Xu LV Ailing DANG Hongxing 《Journal of Ocean University of China》 SCIE CAS CSCD 2019年第5期1051-1060,共10页
The wind retrieval performance of HY-2 A scanning scatterometer operating at Ku-band in HH and VV polarizations has been well evaluated in the wind speed range of 0–25 m s^-1.In order to obtain more accurate ocean wi... The wind retrieval performance of HY-2 A scanning scatterometer operating at Ku-band in HH and VV polarizations has been well evaluated in the wind speed range of 0–25 m s^-1.In order to obtain more accurate ocean wind field,a potential extension of dual-frequency(C-band and Ku-band)polarimetric measurements is investigated for both low and very high wind speeds,from 5 to 45 m s^-1.Based on the geophysical model functions of C-band and Ku-band,the simulation results show that the polarimetric measurements of Ku-band can improve the wind vector retrieval over the entire scatterometer swath,especially in nadir area,with the wind direction root-mean-square error(RMSE)less than 12?in the wind speed range of 5–25 m s^-1.Furthermore,the results also show that C-band cross-polarization plays a very important role in improving the wind speed retrieval,with the wind speed retrieval accuracy better than 2 m s^-1 for all wind conditions(0–45 m s^-1).For extreme winds,the C-band HH backscatter coefficients modeled by CMOD5.N(H)and the ocean co-polarization ratio model at large incidence are used to retrieve sea surface wind vector.This result reveals that there is a big decrease of wind direction retrieval RMSE for extreme wind fields,and the retrieved result of C-band HH polarization is nearly the same as that of C-band VV polarization for low-to-high wind speed(5–25 m s^-1).Thus,to improve the wind retrieval for all wind conditions,the dual-frequency polarimetric scatterometer with C-band and Ku-band horizontal polarization in inner beam,and C-band horizontal and Ku-band vertical polarization in outer beam,can be used to measure ocean winds.This study will contribute to the wind retrieval with merged satellites data and the future spaceborne scatterometer. 展开更多
关键词 dual-frequency polarimetric SCATTEROMETER WIND VECTOR RETRIEVAL
下载PDF
Dual-Frequency Operation of Bow-Tie Microstrip Antenna
15
作者 钟顺时 张需溥 《Journal of Shanghai University(English Edition)》 CAS 2005年第3期234-236,共3页
Characteristics of a single-feed dual-frequency bow-tie microstrip antenna are studied. By using the variation method, simple formulas for resonant frequencies of the bow-tie microstrip antenna are derived. It is show... Characteristics of a single-feed dual-frequency bow-tie microstrip antenna are studied. By using the variation method, simple formulas for resonant frequencies of the bow-tie microstrip antenna are derived. It is shown that the dual-frequency ratio can be controlled easily by choosing the parameters of the antenna. This design gives compact antenna size and simple antenna structure. Experimental results are presented, verifying the validity of the design. 展开更多
关键词 microstrip antennas resonant frequency dual-frequency miniature design.
下载PDF
Effects of HF frequency on plasma characteristics in dual-frequency helium discharge at atmospheric pressure by fluid modeling
16
作者 王一男 李帅星 +3 位作者 王莉 金莹 张艳华 刘悦 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第11期76-83,共8页
On the basis of the fluid theory and the drift-diffusion approximation, a numerical model for dual-frequency atmospheric pressure helium discharge is established, in order to investigate the effects of the high freque... On the basis of the fluid theory and the drift-diffusion approximation, a numerical model for dual-frequency atmospheric pressure helium discharge is established, in order to investigate the effects of the high frequency source (HF) on the characteristics of dual-frequency atmospheric pressure helium discharge. The numerical results showed that the electron heating rate increases with enhancing HF frequency, as well as the particles densities, electron dissipation rate, current density, net electron generation and bulk plasma region. Moreover, it is also observed that the efficient electron heating region moves when the HF frequency has been changed. The plasma parameters are not linear change with the HF frequency linearly increasing. 展开更多
关键词 dual-frequency numerical study electron energy mechanisms
下载PDF
Simulation of Capacitively Coupled Dual-Frequency N_2,O_2,N_2/O_2 Discharges:Effects of External Parameters on Plasma Characteristics
17
作者 尤左伟 戴忠玲 王友年 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第4期335-343,共9页
A one-dimensional fluid model is adopted to simulate the characteristics of N2, O2, and N2/O2 dual-frequency (DF) capacitively coupled plasmas (CCPs) under typical conditions in PECVD technologies. Not only the gr... A one-dimensional fluid model is adopted to simulate the characteristics of N2, O2, and N2/O2 dual-frequency (DF) capacitively coupled plasmas (CCPs) under typical conditions in PECVD technologies. Not only the ground, the excited states but also the vibration levels of the main species are considered. The study focuses on the influence of external parameters such as matching of the high-frequency (HF) and low-frequency (LF), HF and LF of the voltage sources, as well as discharge pressures, on physical characteristics of discharges. The results show that the decoupling of the two sources is possible by increasing the applied HF, the electron density and ion flux are determined only by the HF of the voltage source, whereas the LF has a little influence on the plasma characteristics. In addition, the matching of frequency affects the characteristics of discharges to some extent. Fhrthermore, the pressure is a main external parameter affecting the characteristics of discharges, and a small amount of oxygen in N2 plasma can efficiently increase N+ ion flux incident onto the electrode and the density of N atom. 展开更多
关键词 CCP dual-frequency fluid model N2 discharge O2 discharge
下载PDF
A METHOD FOR DUAL-FREQUENCY IONOSPHERIC TIME-DELAY CORRECTING USING A C/A CODE GPS RECEIVER
18
作者 Zhang Mengyang Lu Baowei Song Wenmiao(Institute of Electronics, Chinese Academy of Sciences, Beijing 100080) 《Journal of Electronics(China)》 1999年第1期66-72,共7页
The ionospheric time delay is one of the main error sources in C/A code GPS navigation and positioning applications. In this paper, a method is proposed for real-time dual-frequency ionospheric time-delay correcting u... The ionospheric time delay is one of the main error sources in C/A code GPS navigation and positioning applications. In this paper, a method is proposed for real-time dual-frequency ionospheric time-delay correcting using a C/A code GPS receiver, and the principle of the circuit block diagram for this method is analyzed with its feasibility theoretically demonstrated. 展开更多
关键词 GPS system IONOSPHERIC TIME-DELAY C/A CODE dual-frequency CORRECTING
下载PDF
Optimization of Nonlinear Energy Sink for Vibration Suppression of Systems Under Dual-Frequency Excitation
19
作者 Sun Bin Wu Zhiqiang 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2018年第6期986-991,共6页
Aiming to decrease the vibration of wing induced by dual-rotor civil turbofan engines,the dynamic models of a single-degree of freedom (DOF) linear main oscillator coupled with single-DOF and two-DOF nonlinear energy ... Aiming to decrease the vibration of wing induced by dual-rotor civil turbofan engines,the dynamic models of a single-degree of freedom (DOF) linear main oscillator coupled with single-DOF and two-DOF nonlinear energy sink (NES) are established.According to the related energy criteria for the optimization of the dynamic vibration absorber,focusing on the effects of external excitation on the kinetic energy of the primary mass and total system energy,the vibration suppression effects of single-DOF,two-DOF serial and parallel NES on the main oscillator system are studied.Under the condition that the characteristic parameters of the main oscillator system and additional total mass of the vibration absorber remain unchanged,results show that the two-DOF parallel NES has the best vibration energy suppression effects,which can provide data reference for the optimal design of NES vibration suppression under dual-frequency excitation. 展开更多
关键词 nonlinear energy sink(NES) CIVIL TURBOFAN engine dual-frequency vibration suppression OPTIMIZATION
下载PDF
Deposition of Polymer Thin Film Using an Atmospheric Pressure Micro-Plasma Driven by Dual-Frequency Excitation
20
作者 王晓敏 袁强华 +2 位作者 周永杰 殷桂琴 董晨钟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第1期68-72,共5页
Polymer thin film deposition using an atmospheric pressure micro-plasma jet driven by dual-frequency excitations is described in this paper. The discharge process was operated with a mixture of argon (6 slm) and a s... Polymer thin film deposition using an atmospheric pressure micro-plasma jet driven by dual-frequency excitations is described in this paper. The discharge process was operated with a mixture of argon (6 slm) and a small amount of acetone (0-2100 ppm). Plasma composition was measured by optical emission spectroscopy (OES). In addition to a large number of Ar spectra lines, we observed some spectra of C, CN, CH and C2. Through changing acetone content mixed in argon, we found that the optimum discharge condition for deposition can be characterized by the maximum concentration of carbonaceous species. The deposited film was characterized by scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared (FTIR) spectroscopy. The XPS indicated that the film was mostly composed of C with trace amount of O and N elements. The FTIR suggested different carbon-containing bonds (-CHx, C=O, C=C, C-O-C) presented in the deposited film. 展开更多
关键词 atmospheric pressure plasma dual-frequency excitation polymer thin film
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部