期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Exploration the Method of Low Dose Coronary Artery Imaging with Dual-Source CT
1
作者 Zhiwei Huang Bo Xiao Lisha Zhong 《Journal of Biosciences and Medicines》 2013年第1期6-10,共5页
Objective: On the premise that the image quality meets the requirements of clinical diagnosis, we explored the methods to reduce the radiation dose of coronary artery imaging with Dual-Source CT (DSCT). Methods: We ra... Objective: On the premise that the image quality meets the requirements of clinical diagnosis, we explored the methods to reduce the radiation dose of coronary artery imaging with Dual-Source CT (DSCT). Methods: We randomly selected 200 patients with coronary heat disease (BIM 0.05). The average image noise in group A is (41.76 ± 7.98) HU, in group B the average image noise is (43.97 ± 3.88) HU, the dif- ference between the two groups was not statistically significant (P>0.05). The average CTDIvol of group A and B were (20.63 ± 2.24) mGy, (38.11 ± 10.69) mGy, respectively, then P <0.01. The average DLP of group A and B are (235.75 ± 28.64) mGycm and (492.59 ± 125.49) mGycm respectively, then P <0.01, the dif- ference of radiation dose had statistical significance (P<0.05). Conclusions: For coronary artery imaging with DSCT the heart electric pulse (AUTO) regulation technology can meet the diagnostic requirements and effectively reduce the radiation dose. 展开更多
关键词 dual-source ct(DSct) CORONARY ct angiography Low DOSE Noise
下载PDF
Application of Dual-Source CT TurboFlash Coarse Pitch Scanning in Coronary Artery Imaging
2
作者 Shuiqing Zhuo Xiaoling Chen +3 位作者 Jingping Yu Haoqiang He Guixiao Xu Chuanmiao Xie 《Open Journal of Medical Imaging》 2018年第3期64-72,共9页
Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scannin... Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scanning mode. Methods: The imaging data of 100 patients who underwent CT coronary angiography (CCTA) using Siemens force CT retrospective gated triggering spiral scan (RES-SPIRAL), adaptive prospective gated triggering sequence scan (SEQ) and prospective coarse pitch scan (TurboFlash) retrospectively was collected. The image quality was evaluated by objective and subjective methods. The effective radiation dose of patients was compared and analyzed, and the indications of the three scanning modes were analyzed. The application value of dual-source CT TurboFlash coarse pitch scanning in coronary artery imaging was evaluated. Results: The results showed that the left main coronary artery, the right coronary artery and their tertiary branches could be clearly displayed in the three groups of images: the left anterior descending branch, the left circumflex branch, and their three-level branches. There was no statistical difference in subjective image quality among the three groups of pictures (P > 0.05). There was no statistical difference in objective evaluation indexes, such as CT value, SNR, CNR and Noise among the three groups (P > 0.05). The patient radiation dose results showed that the effective radiation dose ED of RES-SPIRA scan was (9.22 ± 1.33) mSv. The dose of SEQ was (2.88 ± 2.47) mSv, and the dose of TurboFlash was (0.51 ± 0.16) mSv. There was significant difference in comparison of the three groups (P 0.05). RES-spiral scanning had the highest radiation dose and TurboFlash coarse pitch scanning (TurboFlash) had the lowest radiation dose. Conclusion: TurboFlash coarse pitch scanning is low in dosage, fast in speed and wide in adaptability. It is especially suitable for the elderly, children, coma and other patients who cannot cooperate with breath-holding examination, as well as for the screening and examination of coronary artery diseases in asymptomatic population. Undoubtedly, it is a worthy method of heart coronary artery examination. 展开更多
关键词 dual-source ct CORONARY COMPUTED Tomographic angiography Coarse PITCH SPIRAL SCANNING Image Quality Radiation Dose
下载PDF
双源CT在腹腔镜胃癌根治术术前血管评估中的应用 被引量:4
3
作者 于晶 刘芳 尹家俊 《消化肿瘤杂志(电子版)》 2011年第4期237-239,共3页
目的探讨双源CT血管造影(CT angiography,CTA)对进展期胃癌胃周血管的三维重建能力,评价其对腹腔镜胃癌根治术的指导意义。方法25例拟行腹腔镜胃癌D2根治术患者行腹部双源CT增强扫描,用容积再现技术(volume rendering technique,VRT)进... 目的探讨双源CT血管造影(CT angiography,CTA)对进展期胃癌胃周血管的三维重建能力,评价其对腹腔镜胃癌根治术的指导意义。方法25例拟行腹腔镜胃癌D2根治术患者行腹部双源CT增强扫描,用容积再现技术(volume rendering technique,VRT)进行三维血管重建,根据其CTA表现评价胃周血管的空间解剖特征,将所得的解剖学资料与腹腔镜下血管解剖对比。结果双源CT血管重建准确显示胃左动脉25例,胃右动脉15例,胃左静脉5例,肝动脉、胃十二指肠动脉全部显示,其中肝右动脉起自肠系膜上动脉1例,胃左静脉直接汇入门静脉2例。脾动脉起源相对固定。根据CTA结果指导腹腔镜下进展期胃癌D2根治术,手术均顺利完成,无中转开腹。重建的胃周血管与术中活体解剖完全吻合。结论双源CTA能清晰显示腹腔干及其分支动脉,以及部分静脉血管,对腹腔镜进展期胃癌D2根治术具有重要的指导意义。 展开更多
关键词 双源ct血管造影 腹腔镜 胃癌根治术
下载PDF
Application of Dual-Energy CT Non-Linear Fusion Technology in Improving CTA Image Quality of Renal Cancer 被引量:1
4
作者 Shuiqing Zhuo Xiaoling Chen +2 位作者 Jingping Yu Sihui Zeng Lizhi Liu 《Open Journal of Medical Imaging》 2018年第3期73-80,共8页
Objective: To explore the significance of dual-energy CT non-linear fusion technique in improving the quality of CTA image of renal cancer. Methods: The CTA images of 100 patients who had been confirmed by pathology a... Objective: To explore the significance of dual-energy CT non-linear fusion technique in improving the quality of CTA image of renal cancer. Methods: The CTA images of 100 patients who had been confirmed by pathology as renal cancer were collected and were randomly divided into experimental group and control group with 50 cases respectively. The two groups of patients were treated with iodine concentration of 300 mg/ml and 350 mg/ml non-ionic contrast agent, with a dosage of 1.5 ml/kg and an injection rate of 4 ml/s. The contrast agent intelligently tracking method was adopted bolus. The control group used the conventional CTA scanning, with a reference tube voltage/tube current of 100 kv/ref150 mas. The experimental group adopted the double energy scanning, with ball tube A and ball tube B. The reference tube voltage/tube current was 100 kv/ref250 mas and sn150 kv/ref125 mas respectively. The images of the experimental group were non-linear fused to obtain the Mono+ 55 kev single-energy images. The CT value, SNR contrast ratio of the abdominal aorta, renal artery and tumor tissue of the experimental group images and the 100 KV images and the Mono+ 55 kev images of the control group were compared. The objective evaluation and subjective evaluation of the image quality of the three groups of images was performed. Results: The results showed that the 100 kV images of the experimental group were statistically different from those of the control group (P05) in CT value, SNR and CNR (P 0.05). And there was no statistically significant difference between the non-linear fusion single-energy Mono+ 55 kev images and the control group images in CT value, SNR and CNR (P > 0.05). The subjective evaluation of image quality showed that there was no significant difference between Mono+ 55 kev images and control group images, and the quality of Mono+ 55 kev images was higher than that of experimental group 100 kV images. Conclusion: The dual-energy CT non-linear fusion technique can improve the quality of CTA image in patients with renal cancer, and it is possible to obtain high quality CTA images with low iodine concentration contrast agent. 展开更多
关键词 dual-source ct NON-LINEAR FUSION Technology RENAL Cancer COMPUTED Tomographic angiography Image Quality
下载PDF
Significance of an Advanced Image-Based Virtual Monoenergetic Reconstruction of Dual Source Dual-Energy CT Data at Low keV Increases Image Quality for Portal Vein System of Pancreatic Cancer Patients
5
作者 Shuiqing Zhuo Sihui Zeng +1 位作者 Jingping Yu Lizhi Liu 《Journal of Cancer Therapy》 2018年第10期827-837,共11页
Purpose: To explore the significance of dual-source computed tomography (DECT) virtual monoenergetic reconstructions technology in improving image quality for portal vein system of pancreatic cancer patients. Material... Purpose: To explore the significance of dual-source computed tomography (DECT) virtual monoenergetic reconstructions technology in improving image quality for portal vein system of pancreatic cancer patients. Materials and methods: 47 patients with clinically suspected pancreatic cancer (all confirmed by pathology) were collected. Routine plain scan was performed with Siemens Force dual-source dual-energy CT followed by 3 scans respectively carried out in arterial phase, portal phase and delayed phase. Traditional virtual monoenergetic reconstructions (Mono_E) and new generation of virtual monoenergetic reconstructions (Mono+) were respectively performed on portal vein images to obtain virtual single energy images including Mono_ E70 keV, Mono_E 55 keV and Mono+ 70 keV and Mono+ 55 keV. The signal-to-noise ratio (SNR) and noise of portal vein, normal pancreatic tissues and pancreatic lesions of 100 kV, Mono_E and Mono+ images were compared. In addition, the contrast noise ratio of portal vein and lesions as well as pancreatic tissues and lesions (CNR PV, CNRtumor) were also compared. At the same time, two imaging physicians with rich clinical experiences read the films and scored the images of each group by using the 5-point scoring method. Results: Mono+ 55 keV images including SNRpv, SNRpanc, SNRtumor, Noise, CNRpv, CNRtumor were statistically different from 100 KV images and Mono_E images (P < 0.05). As for the subjective score, Mono+ 55 keV image score also had the highest score, which had statistical significance (P < 0.05). The results showed that Mono+ 55 keV images had the best quality. Conclusion: The new generation of virtual Mono+ post-treatment can reduce image noise. Low energy Mono+ images can improve the contrast between pancreatic cancer lesions and portal of pancreatic cancer patients. 展开更多
关键词 dual-source VIRTUAL Monoenergetic RECONSTRUctIONS Computed Tomography PANCREATIC Tumors Portal VEIN SYSTEM ct angiography Image Quality
下载PDF
Comparison of low-dose sequences of dual-source CT and echocardiography for preoperative evaluation of aortic valve disease 被引量:2
6
作者 FENG Juan WANG Xi-ming +4 位作者 JI Xiao-peng LI Hai-ou LI Qiao GUO Wen-bin WANG Zheng-jun 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第23期4423-4429,共7页
Background Accurate evaluation of coronary artery,aortic valve annulus diameter (AVAD),and cardiac function in patients with aortic valve disease is of great significance for surgical strategy.In this study,we explo... Background Accurate evaluation of coronary artery,aortic valve annulus diameter (AVAD),and cardiac function in patients with aortic valve disease is of great significance for surgical strategy.In this study,we explored the preoperative evaluation of low-dose sequence (MinDose sequence) scan of dual-source CT (DSCT) for those patients.Methods Forty patients suspected for aortic valve disease (the experimental group) underwent MinDose sequence of DSCT to observe coronary artery,AVAD,and left ventricular ejection fraction (LVEF).Another 33 subjects suspected for coronary artery disease (the control group) underwent conventional retrospective electrocardiographically-gated sequence of DSCT.Two-dimensional transthoracic echocardiography (2D-TTE) and four-dimensional transthoracic echocardiography (4D-TTE) were applied in the experimental group to measure AVAD and LVEF and compared with MinDose-DSCT.Results There was a strong correlation between LVEFs measured by 2D-TTE and MinDose-DSCT (r=0.87,P <0.01),as well as between 4D-TTE and MinDose-DSCT (r=0.90,P <0.01).AVAD measured by MinDose-DSCT was in good agreement with corresponding measurements by 2D-TTE (r=0.90,P <0.01).The effective dose in the experimental group was 63.54% lower than that in the control group.Conclusions MinDose sequence of DSCT with a low radiation dose serving as a one-stop preoperative evaluation makes effective assessment of the coronary artery,AVAD,and LVEF for patients with aortic valve disease. 展开更多
关键词 radiation dose coronary ct angiography dual-source ct cardiac function aortic valve annulus diameters
原文传递
心脏电机械偶联与Flash双源CT冠状动脉成像在高心率患者中的应用(英文) 被引量:3
7
作者 韩瑞娟 孙凯 +1 位作者 李立刚 陈九宏 《中华临床医师杂志(电子版)》 CAS 2011年第21期6342-6350,共9页
Objective To assess the image quality and effective radiation dose of prospectively electrocardiogram-triggered high-pitch spiral acquisition (flash spiral mode)dual-source CT coronary angiography in patients with hig... Objective To assess the image quality and effective radiation dose of prospectively electrocardiogram-triggered high-pitch spiral acquisition (flash spiral mode)dual-source CT coronary angiography in patients with high heart rate(HR).Methods From 1321 consecutive patients,seventy patients with HR≥70 bpm (group A) and seventy patients with HR<70 bpm (group B) underwent CT angiography and were prospectively included in this study.The start phase for image acquisition of the most cranial slice was selected at 20%-30% of the R-R interval for group A and at 60% of the RR interval for group B.Assessed the image quality and effective radiation dose of two group.Results (1)There were no significant differences in age,sex,BMI and scan time between the two groups.(2)Image qualities:The segments with non-diagnostic image quality occurred (i.e.score 3) had no significant difference between group A and group B (2.1% vs.1.5%,P=0.48).Non-diagnostic image quality was most often found in the RCA and LCX in both groups.(3)The estimated radiation dose was on average (1.00±0.15) mSv(0.7-1.82 mSv) in group A and (1.01±0.16)mSv (0.65-1.82 mSv) in group B.Conclusions Patients with high heart rates can be performed CTCA with high-pitch spiral acquisition mode.20%-30% of the R-R interval window for data acquisition for high-pitch dual-source CTCA may probably obtain good image quality with low doses.The highest HRs are 100 bpm with good image quality.HR variability is a great effect factor of image quality.The estimated radiation dose is about 1 mSv. 展开更多
关键词 Coronary angiography Heart rate High pitch dual-source ct Prospectively ECG-triggered
原文传递
心房颤动患者的低剂量、大螺距双源CT冠状动脉成像的可行性研究(英文) 被引量:1
8
作者 孙凯 韩瑞娟 +3 位作者 马利军 王利军 李立刚 陈九宏 《中华临床医师杂志(电子版)》 CAS 2011年第20期6027-6032,共6页
Objective The objective was to attempt to rule out whether high-pitch spiral acquisition dual-source computed tomography coronary angiography(CTCA)can be performed in patients with atrial fibrillation at low dose.Meth... Objective The objective was to attempt to rule out whether high-pitch spiral acquisition dual-source computed tomography coronary angiography(CTCA)can be performed in patients with atrial fibrillation at low dose.Methods Ten patients with atrial fibrillation who were admitted for a first diagnostic coronary angiogram were screened for participation.All patients underwent dual-source CT.Patients were performed CTCA using the prospectively ECG-gated high-pitch mode and retrospective ECG gating spiral acquisition respectively with their permissions.The start phase for image acquisition of the most cranial slice was selected at 20%-30% of the R-R interval in all patients.Results Image qualities of prospectively ECG-gated high-pitch mode were rated as being excellent in 7 cases of all the patients and only 3 cases′ image qualities were graded score 2.By using retrospective ECG gating spiral acquisition mode,non-diagnostic image quality (score 3) occurred in 4 patients which were observed in RCA and 1 patient in LCX.The estimated radiation dose ranges from 0.68 to 1.887 mSv in flash mode and the radiation dose of spiral mode were very high ranging from 14.92 to 29.308 mSv.Conclusions Our case series suggest that patients with atrial fibrillation rhythm can be performed CTCA with high-pitch spiral acquisition mode.20%-30% of the RR interval window for data acquisition for high-pitch dual-source CTCA may probably obtain good image quality with low doses. 展开更多
关键词 Coronary angiography Atrial fibrillation dual-source ct High pitch
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部