期刊文献+
共找到3,884篇文章
< 1 2 195 >
每页显示 20 50 100
Effectiveness of magnetic resonance imaging and spiral computed tomography in the staging and treatment prognosis of colorectal cancer
1
作者 Lu-Na Bai Lu-Xian Zhang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第7期2135-2144,共10页
BACKGROUND Colorectal cancer(CRC)is a prevalent cancer type in clinical settings;its early signs can be difficult to detect,which often results in late-stage diagnoses in many patients.The early detection and diagnosi... BACKGROUND Colorectal cancer(CRC)is a prevalent cancer type in clinical settings;its early signs can be difficult to detect,which often results in late-stage diagnoses in many patients.The early detection and diagnosis of CRC are crucial for improving treatment success and patient survival rates.Recently,imaging techniques have been hypothesized to be essential in managing CRC,with magnetic resonance imaging(MRI)and spiral computed tomography(SCT)playing a significant role in enhancing diagnostic and treatment approaches.AIM To explore the effectiveness of MRI and SCT in the preoperative staging of CRC and the prognosis of laparoscopic treatment.METHODS Ninety-five individuals admitted to Zhongshan Hospital Xiamen University underwent MRI and SCT and were diagnosed with CRC.The precision of MRI and SCT for the presurgical classification of CRC was assessed,and pathological staging was used as a reference.Receiver operating characteristic curves were used to evaluate the diagnostic efficacy of blood volume,blood flow,time to peak,permeability surface,blood reflux constant,volume transfer constant,and extracellular extravascular space volume fraction on the prognosis of patients with CRC.RESULTS Pathological biopsies confirmed the following CRC stages:23,23,32,and 17 at T1,T2,T3,and T4,respectively.There were 39 cases at the N0 stage,22 at N1,34 at N2,44 at M0 stage,and 51 at M1.Using pathological findings as the benchmark,the combined use of MRI and SCT for preoperative TNM staging in patients with CRC demonstrated superior sensitivity,specificity,and accuracy compared with either modality alone,with a statistically significant difference in accuracy(P<0.05).Receiver operating characteristic curve analysis revealed the predictive values for laparoscopic treatment prognosis,as indicated by the areas under the curve for blood volume,blood flow,time to peak,and permeability surface,blood reflux constant,volume transfer constant,and extracellular extravascular space volume fraction were 0.750,0.683,0.772,0.761,0.709,0.719,and 0.910,respectively.The corresponding sensitivity and specificity values were also obtained(P<0.05).CONCLUSION MRI with SCT is effective in the clinical diagnosis of patients with CRC and is worthy of clinical promotion. 展开更多
关键词 Magnetic resonance imaging spiral computed tomography Colorectal cancer PROGNOSIS Receiver operating characteristic curve Retrospective study
下载PDF
Non-enhanced Low-tube-voltage High-pitch Dual-source Computed Tomography with Sinogram Affirmed Iterative Reconstruction Algorithm of the Abdomen and Pelvis 被引量:3
2
作者 Hao Sun Hua-dan Xue +5 位作者 Zheng-yu Jin Xuan Wang Yu Chen Yong-lan He Da-ming Zhang Liang Zhu 《Chinese Medical Sciences Journal》 CAS CSCD 2014年第4期214-220,共7页
Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-... Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-enhanced abdominal and pelvic scans. Methods This institutional review board-approved prospective study included 64 patients who gave written informed consent for additional abdominal and pelvic scan with DSCT in the period from November to December 2012. The patients underwent standard non-enhanced CT scans(protocol 1) [tube voltage of 120 k Vp/pitch of 0.9/filtered back-projection(FBP) reconstruction] followed by high-pitch non-enhanced CT scans(protocol 2)(100 k Vp/3.0/SAFIRE). The total scan time, mean CT number, signal-to-noise ratio(SNR), image quality, lesion detectability and radiation dose were compared between the two protocols. Results The total scan time of protocol 2 was significantly shorter than that of protocol 1(1.4±0.1 seconds vs. 7.6±0.6 seconds, P<0.001). There was no significant difference between protocol 1 and protocol 2 in mean CT number of all organs(liver, 55.4±6.3 HU vs. 56.1±6.8 HU, P=0.214; pancreas, 43.6±5.9 HU vs. 43.7±5.8 HU, P=0.785; spleen, 47.9±3.9 HU vs. 49.4±4.3 HU, P=0.128; kidney, 32.2±2.3 HU vs. 33.1±2.3 HU, P=0.367; abdominal aorta, 44.8±5.6 HU vs. 45.0±5.5 HU, P=0.499; psoas muscle, 50.7±4.1 HU vs. 50.3±4.5 HU, P=0.279). SNR on images of protocol 2 was higher than that of protocol 1(liver, 5.0±1.2 vs. 4.5±1.1, P<0.001; pancreas, 4.0±1.0 vs. 3.6±0.8, P<0.001; spleen, 4.7±1.0 vs. 4.1±0.9, P<0.001; kidney, 3.1±0.6 vs. 2.8±0.6, P<0.001; abdominal aorta, 4.1±1.0 vs. 3.8±1.0, P<0.001; psoas muscle, 4.5±1.1 vs. 4.3±1.2, P=0.012). The overall image noise of protocol 2 was lower than that of protocol1(9.8±3.1 HU vs. 11.1±3.0 HU, P<0.001). Image quality of protocol 2 was good but lower than that of protocol 1(4.1±0.7 vs. 4.6±0.5, P<0.001). Protocol 2 perceived 229 of 234 lesions(97.9%) that were detected in protocol 1 in the abdomen and pelvis. Radiation dose of protocol 2 was lower than that of protocol 1(4.4±0.4 m Sv vs. 7.3±2.4 m Sv, P<0.001) and the mean dose reduction was 41.4%. Conclusion The high-pitch DSCT with SAFIRE can shorten scan time and reduce radiation dose while preserving image quality in non-enhanced abdominal and pelvic scans. 展开更多
关键词 high PITCH dual-source computed tomography iterative reconstruction imagequality radiation DOSE
下载PDF
Truncus arteriosus:Diagnosis with dual-source computed tomography angiography and low radiation dose 被引量:2
3
作者 Mustafa Koplay Derya Cimen +4 位作者 Mesut Sivri Osman Güvenc Derya Arslan Alaaddin Nayman Bulent Oran 《World Journal of Radiology》 CAS 2014年第11期886-889,共4页
Truncus arteriosus is an uncommon congenital cardiac abnormality which is characterized by a single arterial trunk origin from the heart that supplies both the systemic,pulmonary and coronary circulation.We present a ... Truncus arteriosus is an uncommon congenital cardiac abnormality which is characterized by a single arterial trunk origin from the heart that supplies both the systemic,pulmonary and coronary circulation.We present a preterm newborn female patient with type 2 truncusarteriosus,left superior vena cava and aberrant subclavian artery diagnosed with low dose dual-source cardiac computed tomography(CT).We discuss that low dose dual-source cardiac CT has more advantages than other imaging methods and it is an important modality for assessment of patients with conotruncal anomalies such as truncusarteriosus. 展开更多
关键词 Truncusarteriosus Type 2 dual-source computed tomography ANGIOGRAPHY Radiation dose
下载PDF
Assessment of Intracardiac and Extracardiac Deformities in Patients with Various Types of Pulmonary Atresia by Dual-Source Computed Tomography
4
作者 Wenlei Qian Xinzhu Zhou +4 位作者 Ke Shi Li Jiang Xi Liu Liting Shen Zhigang Yang 《Congenital Heart Disease》 SCIE 2023年第1期113-125,共13页
Background:Pulmonary atresia(PA)is a group of heterogeneous complex congenital heart disease.Only one study modality might not get a correct diagnosis.This study aims to investigate the diagnostic power of dualsource ... Background:Pulmonary atresia(PA)is a group of heterogeneous complex congenital heart disease.Only one study modality might not get a correct diagnosis.This study aims to investigate the diagnostic power of dualsource computed tomography(DSCT)for all intracardiac and extracardiac deformities in patients with PA compared with transthoracic echocardiography(TTE).Materials and Methods:This retrospective study enrolled 79 patients and divided them into three groups according to their main diagnosis.All associated malformations and clinical information,including treatments,were recorded and compared among the three groups.The diagnostic power of DSCT and TTE on all associated malformations were compared.The surgical index(McGoon ratio,pulmonary arterials index(PAI),and total neopulmonary arterial index)and radiation dose were calculated on the basis of DSCT.Results:Of the patients,32,30,and 17 were divided into the groups of PA with ventricular septal defect(VSD),PA with VSD and major aortopulmonary collateral arteries,and PA with other major malformations,respectively.Consequently,182,162,and 13 intracardiac,extracardiac,and other major malformations were diagnosed,respectively.Moreover,DSCT showed a better diagnostic performance in extracardiac deformities(154 vs.117,p<0.001),whereas TTE could diagnose intracardiac deformities better(159 vs.139,p=0.001).The McGoon ratio,PAI,and treatment methods were significantly different among the three groups(p=0.014,p=0.008,and p=0.018,respectively).Conclusion:More than one imaging modality should be used to make a correct diagnosis when clinically suspecting PA.DSCT is superior to TTE in diagnosing extracardiac deformities and could be used to roughly calculate surgical indices to optimize treatment strategy. 展开更多
关键词 Pulmonary atresia complex congenital heart diseases dual-source computed tomography transthoracic echocardiography
下载PDF
Diagnostic ability of multi-detector spiral computed tomography for pathological lymph node metastasis of advanced gastric cancer 被引量:7
5
作者 Zhi-Yong Jiang Shinichi Kinami +5 位作者 Naohiko Nakamura Takashi Miyata Hideto Fujita Hiroyuki Takamura Nobuhiko Ueda Takeo Kosaka 《World Journal of Gastrointestinal Oncology》 SCIE CAS 2020年第4期435-446,共12页
BACKGROUND The reliability of preoperative nodal diagnosis of advanced gastric cancer by multi-detector spiral computed tomography(MDCT)is still unclear.AIM To examine the diagnostic ability of MDCT more precisely by ... BACKGROUND The reliability of preoperative nodal diagnosis of advanced gastric cancer by multi-detector spiral computed tomography(MDCT)is still unclear.AIM To examine the diagnostic ability of MDCT more precisely by using data on intranodal pathological metastatic patterns.METHODS A total of 108 patients with advanced gastric cancer who underwent MDCT and curative gastrectomy at Kanazawa Medical University Hospital were enrolled in this study.The nodal sizes measured on computed tomography(CT)images were compared with the pathology results.A receiver-operating characteristic curve was constructed,from which the critical value(CV)was calculated by using the data of the first 69 patients retrospectively.By using the CV,sensitivity and specificity were calculated with prospectively collected data from 39 consecutive patients.This enabled a more precise one-to-one correspondence of lymph nodes between CT and pathological examination by using the size data of lymph node mapping.The intranodal pathological metastatic patterns were classified into the following four types:Small nodular,peripheral,large nodular,and diffuse.RESULTS Although all the cases were clinically suspected as having metastasis,81 had lymph node metastasis and 27 had no metastasis.The number of dissected,detected on CT,and metastatic nodes were,4241,897,and 801,respectively.The CV obtained from the receiver-operating characteristic was 7.6 mm for the long axis.The sensitivity was 91.4%and the specificity was 47.3%in the prospective phase.The large nodular and diffuse metastases were easy to diagnose becausemetastatic nodes with a large axis often exhibit these forms.CONCLUSION The ability of MDCT to contribute to a nodal diagnosis of advanced gastric cancer was examined prospectively with precise size data from node mapping,using a CV of 7.6 mm for the long axis that was calculated from the retrospectively collected data.The sensitivity was as high as 91%,and would be improved when referring to the enhanced patterns.However,its specificity was as low as 47%,because most of metastatic nodes in gastric cancer being small in size.The small nodular or peripheral type metastatic nodes were often small and considered difficult to diagnose. 展开更多
关键词 Advanced GASTRIC cancer LYMPH node METASTASIS Multi-detector spiral computed tomography PATHOLOGICAL diagnosis
下载PDF
Segmental radiofrequency ablation of pulmonary vein ostia for patients with refractory paroxysmal atrial fibrillation using multi-slice spiral computed tomography guidance 被引量:6
6
作者 JIANG Chen-yang(蒋晨阳) +7 位作者 WANG Jian-an(王建安) HE Hong(何红) SUN Yong(孙勇) ZHOU Bin-quan(周斌全) 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2005年第12期1153-1156,共4页
Objective: To evaluate the safety and clinical efficacy of segmental radiofrequency ablation of pulmonary vein (PV) ostia for patients with refractory paroxysmal atrial fibrillation (AF) under multi-slice spiral ... Objective: To evaluate the safety and clinical efficacy of segmental radiofrequency ablation of pulmonary vein (PV) ostia for patients with refractory paroxysmal atrial fibrillation (AF) under multi-slice spiral computed tomography (MSCT) guidance before the procedure. Methods: A series of 58 consecutive patients with refractory paroxysmal AF were enrolled to undergo segmental radiofrequency ablation ofPV ostia. The 36 male and 22 female patients with mean age of (57.4±9.5) (32-79) years and no obvious organic heart disease. Before ablation, patients received MSCT to generate 3-dimentional image of the left atrium (LA) and proximal PVs. Patients then underwent segmental radiofrequency ablation ofPV ostia using PV circular mapping catheter manipulated several times to ensure complete isolation between PVs and LA. Results: No complications occurred during the procedure. One patient developed delayed cardiac tamponade, which was drained percutaneously. The mean follow-up time was (17.1±9.3) months. Forty-one patients (95%) experienced improved quality of life one month after the procedure. Thirty-six patients (83%) showed stable sinus rhythm, while 10 patients (23%) required additional anti-arrhythmic drugs. AF returned≥1 time in 6 (14%) patients who underwent anti-arrhythmic drug therapy, but the number of episodes was less than that before the procedure. However, one patient experienced recurrent episodes of atrial flutter. Conclusion: It is safe and effective to perform segmental radiofrequency ablation of PV ostia for patients with refractory paroxysmal AF using MSCT guidance mappening. 展开更多
关键词 Atrial fibrillation Pulmonary vein Radiofrequency ablation Multi-slice spiral computed tomography
下载PDF
Multi-slice spiral computed tomography in differential diagnosis of gastric stromal tumors and benign gastric polyps,and gastric stromal tumor risk stratification assessment 被引量:5
7
作者 Xiao-Long Li Peng-Fei Han +2 位作者 Wei Wang Li-Wei Shao Ying-Wei Wang 《World Journal of Gastrointestinal Oncology》 SCIE 2022年第10期2004-2013,共10页
BACKGROUND The biological characteristics of gastric stromal tumors are complex,and their incidence has increased in recent years.Gastric stromal tumors(GST)have potential malignant tendencies,and the probability of t... BACKGROUND The biological characteristics of gastric stromal tumors are complex,and their incidence has increased in recent years.Gastric stromal tumors(GST)have potential malignant tendencies,and the probability of transformation into malignant tumors is as high as 20%-30%.AIM To investigate the value of multi-slice spiral computed tomography(MSCT)in the differential diagnosis of GST and benign gastric polyps,and GST risk stratification assessment.METHODS We included 64 patients with GST(GST group)and 60 with benign gastric polyps(control group),confirmed by pathological examination after surgery in PLA General Hospital,from January 2016 to June 2021.The differences in the MSCT imaging characteristic parameters and enhanced CT values between the two groups before surgery were compared.According to the National Institutes of Health’s standard,GST is divided into low-and high-risk groups for MSCT imaging characteristic parameters and enhanced CT values.RESULTS The incidences of extraluminal growth,blurred boundaries,and ulceration in the GST group were significantly higher than those in the control group(P<0.05).The CT values and enhanced peak CT values in the arterial phase in the CST group were higher than those in the control group(P<0.05).The MSCT differential diagnosis of GST and gastric polyp sensitivity,specificity,misdiagnosis rate,missed diagnosis rate,and areas under the curve(AUCs)were 73.44%,83.33%,26.56%,16.67%,0.784,respectively.The receiver operating characteristic curves were plotted with the arterial CT value and enhanced peak CT value,with a statistical difference.The results showed that the sensitivity,specificity,misdiagnosis rate,missed diagnosis rate,and AUC value of arterial CT in the differential diagnosis of GST and gastric polyps were 80.18%,62.20%,19.82%,37.80%,and 0.710,respectively.The sensitivity,specificity,misdiagnosis rate,missed diagnosis rate,and AUC value of the enhanced peak CT value in the differential diagnosis of GST and gastric polyps were 67.63%,60.40%,32.37%,39.60%,and 0.710,respectively.The incidence of blurred lesion boundaries and ulceration in the high-risk group was significantly higher than that in the low-risk group(P<0.05).The arterial phase and enhanced peak CT values in the high-risk group were significantly higher than those in the low-risk group(P<0.05).CONCLUSION Presurgical MSCT examination has important value in the differential diagnosis of GST and gastric benign polyps and can effectively evaluate the risk grade of GST patients. 展开更多
关键词 Multi-slice spiral computed tomography Differential diagnosis Gastric stromal tumor Benign gastric polyps Risk stratification
下载PDF
Multi-slice spiral computed tomography in diagnosing unstable pelvic fractures in elderly and effect of less invasive stabilization 被引量:5
8
作者 Jian-Guo Huang Zhi-Yuan Zhang +2 位作者 Liang Li Guang-Bao Liu Xiong Li 《World Journal of Clinical Cases》 SCIE 2022年第14期4470-4479,共10页
BACKGROUND Older people are more likely to experience pelvic fractures than younger people.Multi-slice spiral computed tomography(CT)uses three-dimensional(3D)reconstruction technology to generate 3D images that can c... BACKGROUND Older people are more likely to experience pelvic fractures than younger people.Multi-slice spiral computed tomography(CT)uses three-dimensional(3D)reconstruction technology to generate 3D images that can clearly demonstrate the 3D space of fractures and detect fractures at a higher rate.AIM To investigate the clinical value of multi-slice spiral CT 3D reconstruction in the diagnosis of unstable pelvic fractures in the elderly as well as the effect of less invasive stabilization.METHODS A total of 86 patients with unstable pelvic fractures treated between March 2016 and March 2019 underwent femoral supracondylar bone traction before surgery.Pelvic radiography and multi-row spiral CT were performed successively once the patient’s vital signs and hemodynamic indices were stable.Secondary processing of the original data was performed to obtain 3D reconstruction images and determine the vertical displacement of the pelvis.After basic or complete reduction,minimally invasive internal fixation using hollow lag screws was performed.The detection rates of fracture location and classification by X-ray and CT reconstruction were compared.Patients were divided into two groups according to the presence or absence of preoperative 3D reconstruction to compare postoperative reduction,wound healing time,fracture healing time,hospitalization time,visual analog scale(VAS)score,poor internal fixation,and functional recovery.RESULTS The diagnostic coincidence rates of X-rays for pubic symphysis,ilium wing,sacroiliac periarticular,and sacral fractures were lower than those of CT reconstruction.The coincidence rate of CT reconstruction in the clinical classification of pelvic fractures was 100%,whereas 11 cases were misdiagnosed by X-ray;the total coincidence rate was 87.21%.The total excellent and good rates of postoperative reduction were significantly higher in the study group than in the control group(P<0.05).The wound healing,fracture healing,and hospitalization times were significantly shorter in the study group than in the control group(P<0.05).The VAS scores decreased in both groups postoperatively and were lower in the study group than in the control group(P<0.05).The total incidence of poor postoperative internal fixation was significantly lower in the study group than in the control group(P<0.05).The overall rate of postoperative functional recovery was significantly higher in the study group than in the control group(P<0.05).CONCLUSION Multi-slice spiral CT has high guiding significance for the diagnosis,classification,and treatment of unstable pelvic fractures in the elderly.Preoperative 3D reconstruction can effectively shorten the operation time and promote fracture healing,while minimally invasive internal fixation can effectively reduce pain and promote functional recovery of fracture sites,making it worthy of clinical application. 展开更多
关键词 Multi-slice spiral computed tomography Three-dimensional reconstruction Unstable pelvic fracture Minimally invasive internal fixation Diagnostic value
下载PDF
Efficacy of multi-slice spiral computed tomography in evaluating gastric cancer recurrence after endoscopic submucosal dissection 被引量:2
9
作者 Jian-Jun Yin Xiao Hu +1 位作者 Sen Hu Guo-Hong Sheng 《World Journal of Gastrointestinal Oncology》 SCIE 2023年第9期1636-1643,共8页
BACKGROUND Recurrence is the major challenge facing endoscopic submucosal dissection(ESD)-based treatment therapies for early gastric cancer(EGC).Urgent development of simple and easy surveillance approaches will enha... BACKGROUND Recurrence is the major challenge facing endoscopic submucosal dissection(ESD)-based treatment therapies for early gastric cancer(EGC).Urgent development of simple and easy surveillance approaches will enhance clinical treatment of the disease.AIM To explore the role of computed tomography(CT)recurrence in evaluating EGC after ESD treatment.METHODS We retrospectively recruited patients from our endoscopy department,between January 2002 and December 2015,and analyzed their basic characteristics,including symptoms,CT results,and results of endoscopy with biopsy,among others.RESULTS Among a total of 2150 patients EGC patients surveyed,1362 met our inclusion and exclusion criteria and were therefore enrolled in our study.The cohort’s sensitivity of CT for recurrent GC and specificity were 44.22%and 43.86%,respectively,with negative and positive predictive values of 40.15%(275/685)and 48.01%(325/677),respectively.The area under the curve of arterial and venous CT values for recurrent EGC were 0.545,and 0.604,respectively.Receiver operating characteristic curve revealed no statistically significant differences between arterial and venous CT values for recurrent EGC.CONCLUSION Enhanced CT has superior diagnostic efficacy,but less accuracy,compared to gold standard techniques in patients with recurrent EGC. 展开更多
关键词 computed tomography Early gastric cancer Gastric cancer Multi-slice spiral computed tomography
下载PDF
3D Reconstruction with Spiral Computed Tomography in Choroidal Osteoma 被引量:1
10
作者 Francisco Javier Ascaso Laura Herrera +4 位作者 Laura Villén Rafael Lasierra Juan Ibanez Diana Pérez José Angel Cristóbal 《Open Journal of Ophthalmology》 2013年第1期4-6,共3页
Choroidal osteoma (CO) is a rare, ossifying benign tumor originated in the choroid that typically occurs in otherwise healthy young women (1,2). It is characterized by a yellowish, well demarcated lesion in the juxtap... Choroidal osteoma (CO) is a rare, ossifying benign tumor originated in the choroid that typically occurs in otherwise healthy young women (1,2). It is characterized by a yellowish, well demarcated lesion in the juxtapapillary or macular area. The diagnosis is clinical and can be confirmed with the use of fluorescein or indocyanine angiography, optical coherence tomography, computed tomography or magnetic resonance imaging. Choroidal neovascularization or subretinal fluid, the main causes for vision loss, can be treated with laser therapy, photodynamic therapy or intravitreal antivascular endothelial growth factor therapy. We present a case of choroidal osteoma, showing the role of the high resolution 3D spiral computed tomography. 展开更多
关键词 Choroidal Osteoma 3D spiral computed tomography ULTRASONOGRAPHY Fluorescein Angiography
下载PDF
Computed tomography-based radiomics for prediction of neoadjuvant chemotherapy outcomes in locally advanced gastric cancer: A pilot study 被引量:21
11
作者 Zhenhui Li Dafu Zhang +6 位作者 Youguo Dai Jian Dong Lin Wu Yajun Li Zixuan Cheng Yingying Ding Zaiyi Liu 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 2018年第4期406-414,共9页
Objective: The standard treatment for patients with locally advanced gastric cancer has relied on perioperativeradio-chemotherapy or chemotherapy and surgery. The aim of this study was to investigate the wealth of ra... Objective: The standard treatment for patients with locally advanced gastric cancer has relied on perioperativeradio-chemotherapy or chemotherapy and surgery. The aim of this study was to investigate the wealth of radiomicsfor pre-treatment computed tomography (CT) in the prediction of the pathological response of locally advancedgastric cancer with preoperative chemotherapy.Methods: Thirty consecutive patients with CT-staged Ⅱ/Ⅲ gastric cancer receiving neoadjuvant chemotherapywere enrolled in this study between December 2014 and March 2017. All patients underwent upper abdominal CTduring the unenhanced, late arterial phase (AP) and portal venous phase (PP) before the administration ofneoadjuvant chemotherapy. In total, 19,985 radiomics features were extracted in the AP and PP for each patient.Four methods were adopted during feature selection and eight methods were used in the process of building theclassifier model. Thirty-two combinations of feature selection and classification methods were examined. Receiveroperating characteristic (ROC) curves were used to evaluate the capability of each combination of feature selectionand classification method to predict a non-good response (non-GR) based on tumor regression grade (TRG).Results: The mean area under the curve (AUC) ranged from 0.194 to 0.621 in the AP, and from 0.455 to 0.722in the PP, according to different combinations of feature selection and the classification methods. There was onlyone cross-combination machine-learning method indicating a relatively higher AUC (〉0.600) in the AP, while 12cross-combination machine-learning methods presented relatively higher AUCs (all 〉0.600) in the PP. The featureselection method adopted by a filter based on linear discriminant analysis + classifier of random forest achieved asignificantly prognostic performance in the PP (AUC, 0.722~0.108; accuracy, 0.793; sensitivity, 0.636; specificity,0.889; Z=2.039; P=0.041).Conclusions: It is possible to predict non-GR after neoadiuvant chemotherapy in locally advanced gastriccancers based on the radiomics of CT. 展开更多
关键词 Gastric cancer neoadjuvant chemotherapy radiomics tomography spiral computed
下载PDF
Feasibility and Diagnostic Accuracy for Assessment of Coronary Artery Stenosis of Prospectively Electrocardiogram-gated High-pitch Spiral Acquisition Mode Dual-source CT Coronary Angiography in Patients with Relatively Higher Heart Rates: in Comparison wit 被引量:4
12
作者 Kai Sun Rui-juan Han +5 位作者 Li-fang Cui Rui-ping Zhao Li-jun Ma Li-jun Wang Li-gang Li Chang-yong Li 《Chinese Medical Sciences Journal》 CAS CSCD 2012年第4期213-219,共7页
Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography corona... Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch spiral acquisition mode with image acquired timing set at 20%-30% of the R-R interval provides a high diagnostic accuracy for the assessment of coronary stenoses combined with a 1.5% of non-diagnostic coronary segments and a radiation dose below 1 mSv. 展开更多
关键词 dual-source computed tomography coronary angiography high pitch prospectively electrocardiogram-triggered spiral mode high heart rate diagnostic accuracy
下载PDF
Portal vein computed tomography imaging characteristics and their relationship with bleeding risk in patients with liver cirrhosis undergoing interventional therapy 被引量:3
13
作者 Xue-Jing Song Jing-Lei Liu +1 位作者 Shu-Ya Jia Kai Zhang 《World Journal of Clinical Cases》 SCIE 2023年第18期4277-4286,共10页
BACKGROUND This study aimed to analyze the predictive value of multi-slice spiral computed tomography(CT)perfusion imaging for upper gastrointestinal bleeding in patients with cirrhotic portal hypertension.A total of ... BACKGROUND This study aimed to analyze the predictive value of multi-slice spiral computed tomography(CT)perfusion imaging for upper gastrointestinal bleeding in patients with cirrhotic portal hypertension.A total of 62 patients with cirrhotic portal hypertension and 28 healthy individuals were included.The results showed that multi-slice spiral CT perfusion imaging had a significant predictive value for upper gastrointestinal bleeding in patients with cirrhotic portal hypertension.The vascular area,number of vascular cross-sections,and gastric coronary vein diameter(GCVD)showed high predictive values,with the vascular area having the best predictive value.AIM To investigate the predictive accuracy of multi-slice spiral CT perfusion imaging for upper gastrointestinal bleeding in patients with cirrhosis and portal hypertension.METHODS This study included 62 patients with cirrhotic portal hypertension(disease group)and 28 healthy individuals(control group).The disease group was further divided into two subgroups:Group A(n=27,bleeding)and group B(n=35,no bleeding).All patients underwent multi-slice spiral CT perfusion imaging at our hospital,and we compared various parameters such as liver blood flow,vein size,number of blood vessels,and blood vessel area between the two groups.We employed statistical analysis to identify factors associated with upper gastrointestinal bleeding and created a graph comparing the predictive value of different factors for bleeding.RESULTS We found no difference in hepatic artery(HAP)levels among the three groups(all P>0.05).The portal vein levels in groups A and B were much lower than in the control group;group A was much lower than group B(all P<0.05).The HAP perfusion index levels in groups A and B were much higher than in the control group;group A was much higher than group B(all P<0.05).The portal vein diameter,splenic vein diameter,and GCVD levels in groups A and B were much higher than in the control group;those in group A were much higher than those in group B(all P<0.05).The number of blood vessels and blood vessel area in groups A and B were much higher than in the control group;those in group A were much higher than those in group B(all P<0.05).The statistical method showed a strong link between GCVD,number of blood vessels,blood vessel area,and upper gastrointestinal bleeding(odds ratio=1.275,1.346,1.397,P<0.05).The graph showed that GCVD,number of blood vessels,and blood vessel area could predict bleeding well,with blood vessel area having the best prediction power.CONCLUSION That multi-slice spiral CT perfusion imaging can predict upper gastrointestinal bleeding well in patients with cirrhosis and high blood pressure in the portal vein.GCVD,number of blood vessels,and blood vessel area had high prediction power.The blood vessel area had the best prediction power,with an area under the curve of 0.831. 展开更多
关键词 Multi-slice spiral computed tomography PERFUSION CIRRHOSIS Portal hypertension Upper gastrointestinal bleeding Predictive value
下载PDF
Dose Efficiency in Dual Source High-Pitch Computed Tomography of the Chest
14
作者 Boris Bodelle Thomas Lehnert +2 位作者 Martin Beeres Thomas Josef Vogl Boris Schulz 《Advances in Computed Tomography》 2014年第4期51-58,共8页
Objectives: Evaluation of radiation efficiency of dual source high-pitch (DSHP) chest CT in comparison to single source technique with special regards to individual patient anatomy. Methods: 150 consecutive patients w... Objectives: Evaluation of radiation efficiency of dual source high-pitch (DSHP) chest CT in comparison to single source technique with special regards to individual patient anatomy. Methods: 150 consecutive patients who underwent chest CT with automated tube current modulation were evaluated retrospectively and divided into three study groups, each with an equal quantity of 50 patients (DSHP vs. single source 128 slices vs. single source 16 slices). By using a dedicated workstation, volumetric analyses of each of the scanned anatomic area were performed and correlated to the individual dose length product (DLP). The calculated result was defined as dose efficiency. Results: DLP was 203 mGycm (DSHP), vs. 269 mGycm (single source) vs. 273 mGycm (16 slice CT). The total patient volume was lowest in the dual source group with 18956.3 cm3 (vs. 22481.2 cm3 vs. 22133.8 cm3). With regards to the DLP, the calculated dose efficiency of dual source CT was better than the 128 slice CT (p = 0.045) and the 16 slice CT (p < 0.01). Conclusions: DSHP CT has considerably better dose efficiency compared to 16 slice CT. Compared to 128 slice single source technique, the high-pitch mode does not cause any dose penalty when performing chest CT. 展开更多
关键词 computed tomography LUNG Radiation Exposure Imaging dual-source
下载PDF
Intravenous Contrast Material Administration at High-pitch Dual-source CT Coronary Angiography: Bolus-tracking Technique with Shortened Time of Respiratory Instruction Versus Test Bolus Technique 被引量:2
15
作者 Kai Sun Guo-rong Liu +5 位作者 Yue-chun Li Rui-juan Han Li-fang Cui Li-jun Ma Li-gang Li Chang-yong Li 《Chinese Medical Sciences Journal》 CAS CSCD 2012年第4期225-231,共7页
Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acqu... Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acquisition mode (Flash mode) coronary computed tomography angiography (CCTA) compared with test bolus technique. Methods One hundred and eighty-four consecutive patients with mean heart rate ≤65 beats per minute undergoing CCTA were prospectively included in this study. The patients were randomly divided into two groups. Patients in the group A (n=92) instructed to shorten respiratory time received CCTA using bolus-tracking technique with high-pitch spiral acquisition mode (Flash mode), while those in the group B (n=92) underwent CCTA with test bolus technique. The attenuation in the ascending aorta, image noise, contrast-to-noise ratio and radiation doses of the two groups were assessed. Results There were no significant differences in the mean attenuation values in the ascending aorta (483.18±59.07 HU vs. 498.7±83.51 HU, P=0.183), image noise (21.4±4.5 HU vs. 20.9±4.3 HU, P=0.414), contrast-to-noise ratio (12.1±4.2 vs. 13.8±5.1, P=0.31) between the groups A and B. There were no significant differences in the radiation dose of dynamic monitoring scans (0.056±0.026 mSv vs. 0.062±0.018 mSv, P=0.068) and radiation dose of angiography (0.94±0.07 mSv vs. 0.96±0.15 mSv,P=0.926) between the two groups, while 15 mL less contrast material volume was administered in the group A than the group B. Conclusion Bolus-tracking technique with shortened time of respiratory in Flash mode of dual-source CT yields the similar homogeneous enhancement with less contrast material in comparison to the test bolus technique. 展开更多
关键词 dual-source computed tomography coronary angiography contrastenhancement test bolus technique bolus-tracking technique
下载PDF
Application of Dual-Source CT TurboFlash Coarse Pitch Scanning in Coronary Artery Imaging
16
作者 Shuiqing Zhuo Xiaoling Chen +3 位作者 Jingping Yu Haoqiang He Guixiao Xu Chuanmiao Xie 《Open Journal of Medical Imaging》 2018年第3期64-72,共9页
Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scannin... Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scanning mode. Methods: The imaging data of 100 patients who underwent CT coronary angiography (CCTA) using Siemens force CT retrospective gated triggering spiral scan (RES-SPIRAL), adaptive prospective gated triggering sequence scan (SEQ) and prospective coarse pitch scan (TurboFlash) retrospectively was collected. The image quality was evaluated by objective and subjective methods. The effective radiation dose of patients was compared and analyzed, and the indications of the three scanning modes were analyzed. The application value of dual-source CT TurboFlash coarse pitch scanning in coronary artery imaging was evaluated. Results: The results showed that the left main coronary artery, the right coronary artery and their tertiary branches could be clearly displayed in the three groups of images: the left anterior descending branch, the left circumflex branch, and their three-level branches. There was no statistical difference in subjective image quality among the three groups of pictures (P > 0.05). There was no statistical difference in objective evaluation indexes, such as CT value, SNR, CNR and Noise among the three groups (P > 0.05). The patient radiation dose results showed that the effective radiation dose ED of RES-SPIRA scan was (9.22 ± 1.33) mSv. The dose of SEQ was (2.88 ± 2.47) mSv, and the dose of TurboFlash was (0.51 ± 0.16) mSv. There was significant difference in comparison of the three groups (P 0.05). RES-spiral scanning had the highest radiation dose and TurboFlash coarse pitch scanning (TurboFlash) had the lowest radiation dose. Conclusion: TurboFlash coarse pitch scanning is low in dosage, fast in speed and wide in adaptability. It is especially suitable for the elderly, children, coma and other patients who cannot cooperate with breath-holding examination, as well as for the screening and examination of coronary artery diseases in asymptomatic population. Undoubtedly, it is a worthy method of heart coronary artery examination. 展开更多
关键词 dual-source CT CORONARY computed Tomographic ANGIOGRAPHY Coarse PITCH spiral SCANNING Image Quality Radiation Dose
下载PDF
儿童新型冠状病毒感染并发纵隔气肿八例影像学及临床特点研究
17
作者 付强 任作雷 +5 位作者 林志强 龚剑峰 王长征 王婷 胡雅兰 谭举方 《中国全科医学》 CAS 北大核心 2025年第4期510-515,共6页
背景儿童新型冠状病毒感染(COVID-19)影像学与成人有一定差异,主要表现为胸膜下磨玻璃影、斑片状高密度影、实变影等,合并纵隔气肿者并不多见。大量气肿形成可严重影响呼吸及循环功能,导致明显喘憋、低氧血症,需积极处理。目的分析并总... 背景儿童新型冠状病毒感染(COVID-19)影像学与成人有一定差异,主要表现为胸膜下磨玻璃影、斑片状高密度影、实变影等,合并纵隔气肿者并不多见。大量气肿形成可严重影响呼吸及循环功能,导致明显喘憋、低氧血症,需积极处理。目的分析并总结儿童COVID-19并发纵隔气肿的影像学及临床特征。方法回顾分析2022-12-01—2023-01-30在长江大学附属荆州医院儿科住院的8例COVID-19并发纵隔气肿的患儿年龄、性别、影像学、临床特点及诊疗情况。结果8例患儿年龄3岁7个月~12岁,男女比3∶5,高分辨率CT(HRCT)均显示双肺感染合并纵隔气肿。气肿多同时累及颈部及胸壁。肺部表现多种多样:胸膜下磨玻璃影、实变、树芽征、支气管血管束增粗、支气管壁增厚及网格征等,未见大片实变及“白肺”。1例患儿合并少量胸腔积液。临床表现除有发热、咳嗽外,均有明显气促,肺部听诊干湿啰音可不显著。4例合并肺炎支原体感染、1例合并卡他布兰汉菌感染。合并肺炎支原体感染者应用阿奇霉素,合并卡他布兰汉菌感染者给予头孢噻肟治疗。8例患儿均给予氧疗。1例患儿白细胞总数及超敏C反应蛋白明显升高,明显气急,低氧血症,常规治疗无好转,给予有创呼吸机治疗3d后好转撤机。5例应用静脉丙种球蛋白(IVIG),3例使用糖皮质激素。1周后复查胸部CT,纵隔气肿均完全吸收,肺部病灶明显好转。结论COVID-19并发纵隔气肿者多为学龄前期或学龄期儿童,婴幼儿少见。可同时合并颈部及胸壁积气。肺部病变可累及间质或实质、双肺均受累,表现形式多样。起病多有明显气急,积极氧疗。白细胞计数明显升高,同时超敏C反应蛋白明显升高者,要密切关注呼吸情况,积极使用IVIG,适时适量应用糖皮质激素,必要时采用呼吸机人工辅助通气。 展开更多
关键词 新型冠状病毒感染 纵隔气肿 临床特征 体层摄影术 螺旋计算机 儿童
下载PDF
Diagnostic Value of Prospective Electrocardiogram-triggered Dual-source Computed Tomography Angiography for Infants and Children with Interrupted Aortic Arch
18
作者 Hai-Ou Li Xi-Ming Wang +4 位作者 Pei Nie Xiao-Peng Ji Zhao-Ping Cheng Jiu-Hong Chen Zhuo-Dong Xu 《Chinese Medical Journal》 SCIE CAS CSCD 2015年第9期1184-1189,共6页
Background:Accurate assessment of intra-as well as extra-cardiac malformations and radiation dosage concerns are especially crucial to infants and children with interrupted aortic arch (IAA).The purpose of this stu... Background:Accurate assessment of intra-as well as extra-cardiac malformations and radiation dosage concerns are especially crucial to infants and children with interrupted aortic arch (IAA).The purpose of this study is to investigate the value of prospective electrocardiogram (ECG)-triggered dual-source computed tomography (DSCT) angiography with low-dosage techniques in the diagnosis of IAA.Methods:Thirteen patients with suspected IAA underwent prospective ECG-triggered DSCT scan and transthoracic echocardiography (TTE).Surgery was performed on all the patients.A five-point scale was used to assess image quality.The diagnostic accuracy ofDSCT angiography and TTE was compared with the surgical findings as the reference standard.A nonparametric Chi-square test was used for comparative analysis.P<0.05 was considered as a significant difference.The mean effective radiation dose (ED) was calculated.Results:Diagnostic DSCT images were obtained for all the patients.Thirteen IAA cases with 60 separate cardiovascular anomalies were confirmed by surgical findings.The diagnostic accuracy of TTE and DSCT for total cardiovascular malformations was 93.7% and 97.9% (P>0.05),and that for extra-cardiac vascular malformations was 92.3% and 99.0% (P < 0.05),respectively.The mean score of image quality was 3.77 ± 0.83.The mean ED was 0.30 ± 0.04 mSv (range from 0.23 mSv to 0.39 mSv).Conclusions:In infants and children with IAA,prospective ECG-triggered DSCT with low radiation exposure and high diagnostic efficiency has higher accuracy compared to TTE in detection of extra-cardiac vascular anomalies. 展开更多
关键词 dual-source computed tomography Image Quality Interrupted Aortic Arch Prospective ECG-triggered Radiation Dose
原文传递
Expression of nm23, KAI1 and spiral computed tomography findings in primary gallbladder carcinoma 被引量:9
19
作者 JIANG Wen-xia SONG Bo-gen WANG Pei-jun 《Chinese Medical Journal》 SCIE CAS CSCD 2009年第21期2666-2668,共3页
Primary gallbladder carcinoma is the most common malignant tumor of the biliary system. There is a reduced likelihood for radical cure of primary gallbladder carcinomas because of the insidious onset.1 Spiral computed... Primary gallbladder carcinoma is the most common malignant tumor of the biliary system. There is a reduced likelihood for radical cure of primary gallbladder carcinomas because of the insidious onset.1 Spiral computed tomography (SCT) scanning is an important means for diagnosing lesions involving the gallbladder. We determined the expression of anti-metastasis protein nm23 and KAI1 using immunohistochemical method and analyzed the relationship between their expression and the pre-operatively SCT imaging findings, the histopathologic grade, clinical stage, 5-year survival rate in 35 cases of primary gallbladder cancer. 展开更多
关键词 gallbladder carcinoma spiral computed tomography NM23 KAI1
原文传递
Observation of the effect of targeted therapy of 64-slice spiral CT combined with cryoablation for liver cancer 被引量:23
20
作者 Qiao-Huan Yan Dian-Guo Xu +4 位作者 Yan-Feng Shen Ding-Ling Yuan Jun-Hui Bao Hai-Bin Li Ying-Gang Lv 《World Journal of Gastroenterology》 SCIE CAS 2017年第22期4080-4089,共10页
AIM to observe the effect of targeted therapy with 64-slice spiral computed tomography (CT) combined with cryoablation for liver cancer. METHODS A total of 124 patients ( 142 tumors) were enrolled into this study. Acc... AIM to observe the effect of targeted therapy with 64-slice spiral computed tomography (CT) combined with cryoablation for liver cancer. METHODS A total of 124 patients ( 142 tumors) were enrolled into this study. According to the use of dual-slice spiral CT or 64-slice spiral CT as a guide technology, patients were divided into two groups: dual-slice group (n = 56, 65 tumors) and 64-slice group (n = 8, 77 tumors). All patients were accepted and received targeted therapy by an argon-helium superconducting surgery system. The guided scan times of the two groups was recorded and compared. In the two groups, the lesion ice coverage in diameter of >= 3 cm and < 3 cm were recorded, and freezing effective rate was compared. Hepatic perfusion values [ hepatic artery perfusion (HAP), portal vein perfusion (PVP), and the hepatic arterial perfusion index (HAPI)] of tumor tissues, adjacent tissues and normal liver tissues at preoperative and postoperative four weeks in the two groups were compared. Local tumor changes were recorded and efficiency was compared at four weeks post-operation. Adverse events were recorded and compared between the two groups, including fever, pain, frostbite, nausea, vomiting, pleural effusion and abdominal bleeding. RESULTS Guided scan times in the dual-slice group was longer than that in the 64-slice group (t = 11.445, P = 0.000). The freezing effective rate for tumors < 3 cm in diameter in the dual-slice group (81.58%) was lower than that in the 64-slice group (92.86%) (chi(2) = 5.707, P = 0.017). The HAP and HAPI of tumor tissues were lower at four weeks post-treatment than at pretreatment in both groups (all P < 0.05), and those in the 64-slice group were lower than that in the dual-slice group ( all P < 0.05). HAP and PVP were lower and HAPI was higher in tumor adjacent tissues at post-treatment than at pre-treatment ( all P < 0.05). Furthermore, the treatment effect and therapeutic efficacy in the dual-slice group were lower than the 64-slice group at four weeks post-treatment (all P < 0.05). Moreover, pleural effusion and intraperitoneal hemorrhage occurred in patients in the dual-slice group, while no complications occurred in the 64-slice group (all P < 0.05). CONCLUSION 64-slice spiral CT applied with cryoablation in targeted therapy for liver cancer can achieve a safe and effective freezing treatment, so it is worth being used. 展开更多
关键词 64-slice spiral computed tomography CRYOABLATION Liver cancer
下载PDF
上一页 1 2 195 下一页 到第
使用帮助 返回顶部