期刊文献+
共找到26篇文章
< 1 2 >
每页显示 20 50 100
Filtration performance and modeling of granular bed for dust removal from coal pyrolytic vapors
1
作者 Shuaiqiang Yang Lin Du +3 位作者 Guangchao Ding Runguo Liu Wenli Song Songgeng Li 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第1期35-42,共8页
Dust removal from pyrolytic vapors at high temperatures is an obstacle to the industrialization of the coal pyrolysis process.In this work,a granular bed with expanded perlites as filtration media was designed and int... Dust removal from pyrolytic vapors at high temperatures is an obstacle to the industrialization of the coal pyrolysis process.In this work,a granular bed with expanded perlites as filtration media was designed and integrated into a 10 t·d^(–1)coal pyrolysis facility.The testing results showed that around 97.56%dust collection efficiency was achieved.As a result,dust content in tar was significantly lowered.The pressure drop of the granular bed maintained in the range of 356 Pa to 489 Pa.The dust size in the effluent after filtration exhibited a bimodal distribution,which was attributed to the heterogeneity of the dust components.The effects of filtration bed on pyrolytic product yields were also discussed.A modified filtration model based on the macroscopic phenomenological theory was proposed to describe the performance of the granular bed.The computation results were well agreed with the experimental data. 展开更多
关键词 Granular bed filtration dust removal PYROLYSIS FILTRATION FIXED-BED
下载PDF
Design and Numerical Simulation of Dust Removal System for Sutomotive Iongitudinal Beam Plasma Cutting
2
作者 Wenqiang GAO Xudong MA Heyu TIAN 《Mechanical Engineering Science》 2024年第1期30-34,共5页
To improve the poor efficiency of the dust removal system in the plasma cutting station of automotive longitudinal beams,and reduce the cutting surface quality degradation due to dust,a bottom-side suction dust remova... To improve the poor efficiency of the dust removal system in the plasma cutting station of automotive longitudinal beams,and reduce the cutting surface quality degradation due to dust,a bottom-side suction dust removal system is designed,and the dust removal effect is optimized through the setting of the following dampers and diversion plates.The result of numerical simulation indicates that the particle collection rate can reach 99.44%,and the field test also proves the effectiveness of the dust removal system,which is of guiding significance for the transformation of other similar dust removal systems. 展开更多
关键词 plasma cutting dust removal equipment SIMULATION
下载PDF
Effect of photovoltaic panel electric field on the wind speed required for dust removal from the panels 被引量:1
3
作者 李兴财 王娟 +1 位作者 刘滢格 马鑫 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第8期296-303,共8页
Methods to remove dust deposits by high-speed airflow have significant potential applications,with optimal design of flow velocity being the core technology.In this paper,we discuss the wind speed required for particl... Methods to remove dust deposits by high-speed airflow have significant potential applications,with optimal design of flow velocity being the core technology.In this paper,we discuss the wind speed required for particle removal from photovoltaic(PV)panels by compressed air by analyzing the force exerted on the dust deposited on inclined photovoltaic panels,which also included different electrification mechanisms of dust while it is in contact with the PV panel.The results show that the effect of the particle charging mechanism in the electric field generated by the PV panel is greatly smaller than the effect of the Van der Waals force and gravity,but the effect of the particle charged by the contact electrification mechanism in the electrostatic field is very pronounced.The wind speed required for dust removal from the PV panel increases linearly with the PV panel electric field,so we suggest that the nighttime,when the PV electric field is relatively small,would be more appropriate time for dust removal.The above results are of great scientific importance for accurately grasping the dust distribution law and for achieving scientific removal of dust on PV panels. 展开更多
关键词 photovoltaic power generation dust removal electrostatic force required wind speed contact electrification
下载PDF
Numerical Simulation of Dust Removal in the Cyclone Collector of a Straw Crusher Based on a Discrete Phase Model
4
作者 Zhuang Wu Chang Su +1 位作者 Hua Xu Liu Wang 《Fluid Dynamics & Materials Processing》 EI 2023年第5期1143-1157,共15页
The cyclone dust collector is an important subsystem of straw crushers used in agriculture.In the present study,a new type of dust collector with involute morphology is proposed to obtain better dust removal efficienc... The cyclone dust collector is an important subsystem of straw crushers used in agriculture.In the present study,a new type of dust collector with involute morphology is proposed to obtain better dust removal efficiency with respect to that of classical tangential and spiral dust collectors.A discrete phase model(DPM)method is used in synergy with a turbulence model,and the SIMPLE algorithm to simulate the flow field inside the dust collector and the related particle dynamics.It is shown that the internal flow field features a primary swirl,a secondary swirl and blockage effects.Moreover,for the involute dust collector,the tangential velocity in the initial stage and the pressure in the high-pressure area are larger than those obtained for the classical types.The dust removal efficiency is 37.11%,25.3%,and 16.37%for the involute type dust collector,the tangential type and the spiral type,respectively. 展开更多
关键词 Cyclone dust collector the involute type efficiency of dust removal numerical simulation
下载PDF
Dust removal efficiency of high pressure atomization in underground coal mine 被引量:9
5
作者 Pengfei Wang Xuanhao Tan +2 位作者 Weimin Cheng Gang Guo Ronghua Liu 《International Journal of Mining Science and Technology》 EI CSCD 2018年第4期677-682,共6页
To master theoretical calculation for dust removal efficiency of high pressure atomization in an underground coal mine, the corresponding atomization characteristics and dust removal efficiency were both comprehensive... To master theoretical calculation for dust removal efficiency of high pressure atomization in an underground coal mine, the corresponding atomization characteristics and dust removal efficiency were both comprehensively studied in theory by virtue of related theories of hydromechanics and aerosol.According to actual measurements of flow coefficients and atomization angles of X-type swirl nozzle,computational formula was derived for atomized particle sizes of such a nozzle in conjunction with relevant empirical equation. Moreover, a mathematical model for applying high pressure atomization to dust removal in underground coal mine was also established to deduce theoretical computation formula of fractional efficiency. Then, Matlab was adopted to portray the relation curve between fractional efficiency and influence factors. In addition, a theoretical formula was also set up for removal efficiency of respirable dust and total coal dust based on dust size and frequency distribution equations. In the end,impacts of dust characteristic parameters on various dust removal efficiencies were analyzed. 展开更多
关键词 Underground coal mine High pressure atomization Atomization characteristics dust removal efficiency
下载PDF
Water film area and dust removal efficiency of string grilles:a theoretical analysis
6
作者 Hua Guo Haiqiao Wang +1 位作者 Shiqiang Chen Zhirong Wu 《International Journal of Coal Science & Technology》 EI CAS CSCD 2021年第5期1015-1024,共10页
Based onmultiphase flowtheory and capillary mechanics,the dimensionless bond number expression of the influence of string grille wire spacing on droplet spreading is derived.Taking a liquid film formed by spreading dr... Based onmultiphase flowtheory and capillary mechanics,the dimensionless bond number expression of the influence of string grille wire spacing on droplet spreading is derived.Taking a liquid film formed by spreading droplets based on Kelvin correlation,the Young-Laplace equation,and the Hagen-Poiseuille law,an equation for calculating the thickness and height of the liquid film is established with temperature,relative humidity and molar volume of liquid phase as independent variables.According to the theory of string grille filtration and dust removal,a dust removal efficiency calculation model covering the wet string grille wire group is constructed based on the liquid film thickness,height,wire diameter,water film area,and vortex shedding frequency.Finally,a theoretical analysis of the influence of water film area on the efficiency of wet string grille dust removal is carried out based on the spray pressure and the ratio of string grille wire distance to wire diameter.It is found that the effect of spray pressure on water film area and dust removal efficiency is more significant than the string grille wire distance diameter ratio.Moreover,the optimized combination of wet string grille wire distance diameter ratio 0.84,wind speed 3m/s and spray pressure 0.8 MPa is found,which could provide an important reference for engineering applications. 展开更多
关键词 String grille Wetting mechanism Capillary action Water film area dust removal efficiency
下载PDF
An Automatic Dust Removal Device Based on SCM for Solar Panels
7
作者 Weishuo Zheng 《International Journal of Technology Management》 2013年第7期106-108,共3页
This paper introduces a set of automatic dust removal device for street lamp solar panels. The device realizes the automatic dust removal for street lamp solar panels by three steps consisting of data acquisition, aut... This paper introduces a set of automatic dust removal device for street lamp solar panels. The device realizes the automatic dust removal for street lamp solar panels by three steps consisting of data acquisition, automatic control and mechanical dust removal. Our scheme is as follows, according to the comparison between the actual power generation and the relatively ideal condition of power generation of solar panels, we selectively conduct dust removal operation to panels. The paper demonstrates the feasibiliW of the technology based on the example of street lamp solar panels (40w). According to the calculation, the solar panels equipped with our device will greatly improve the power generation efficiency of solar panels, which means there will be 32 more degrees generated every year. Extension and application of the technique device will be beneficial for the improvement of solar panels power generation efficiency and the extension of the service life of the panels. 展开更多
关键词 solar panels SCM automatic dust removal energy saving environmental protection
下载PDF
Mechanism of dust removal by a standing wave electric curtain 被引量:4
8
作者 SUN QiXia YANG NingNing +1 位作者 CAI XiaoBing HU GengKai 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS 2012年第6期1018-1025,共8页
In this paper,the mechanisms of particle movement on an electric curtain are examined.Intermittent bursts in which particles leaping from a surface of an electric curtain are demonstrated both by numerical simulation ... In this paper,the mechanisms of particle movement on an electric curtain are examined.Intermittent bursts in which particles leaping from a surface of an electric curtain are demonstrated both by numerical simulation and experimental observation.The hopping and surfing modes during particle removal are shown to depend on the particle electric charge and its initial position.The particles initially located on the top of electrode have a large electric charge tend to assume a hopping mode.Transverse movement of the particle initially located between the electrodes is analyzed,and the particle traps along the electric curtain surface are also observed. 展开更多
关键词 electrical curtain dust removal dielectrophoresis force particle dynamic simulation
原文传递
Design and implementation of a coal-dust removal device for heavy-haul railway tunnels 被引量:2
9
作者 Yuanjun Li Zhigang Meng 《Transportation Safety and Environment》 EI 2020年第4期283-291,共9页
The Daqin Railway is China’s first electrified double-track heavy-haul railway line dedicated to coal transportation.Over the years of operation,the tunnels have been covered with a thick layer of coal dust,which als... The Daqin Railway is China’s first electrified double-track heavy-haul railway line dedicated to coal transportation.Over the years of operation,the tunnels have been covered with a thick layer of coal dust,which also pervades in the air.Worse is that the coal dust has even buried the rail joints in some sections,making the repair and maintenance of the line difficult.This paper introduces a coal-dust removal device for railway tunnels that integrates pipeline transportation with dust-collection techniques.The device is mainly composed of a power system,a conveying system,a dust-filtration and collection system,and a control and protection system.The key technical elements of the system,such as the dust-extraction method and dust-filtration and collection parameters,are optimized based on the characteristics of the coal dust in the tunnel(obtained via field trials),which greatly enhances the adaptability of the device.Coal-dust removal efficiency reached over 20 t/h,which improves the working environment,reduces the intensity of manual work required and solves the problem of coal-dust removal from the most polluted area—within 500 m of the tunnel entrance. 展开更多
关键词 heavy-haul railway tunnel dust removal tunnel maintenance
原文传递
Experimental study of the dust-removal performance of a wet scrubber 被引量:1
10
作者 Shengyong Hu Yang Gao +3 位作者 Guorui Feng Fei Hu Changhe Liu Jihua Li 《International Journal of Coal Science & Technology》 EI CAS CSCD 2021年第2期228-239,共12页
A variety of dust control methods are often applied in coal mines,among which the application of wet scrubbers has proven to be an efficient technology for the removal of dust in airstreams,rather than diluting or con... A variety of dust control methods are often applied in coal mines,among which the application of wet scrubbers has proven to be an efficient technology for the removal of dust in airstreams,rather than diluting or confining the dust.In this paper,a wet scrubber design was developed.Based on a self-designed experimental test platform,the total dust concentration,respirable dust concentration,air volume,and average pressure drops of wet scrubbers with 12,16,20,and 24 blades were measured under different water intake conditions.The results show that the different water intake levels have only minimal effects on the air volume of the wet scrubbers.However,increased water intake had improved the dust removal efficiency of the wet scrubbers with the same number of blades.The wet scrubber with 16 blades was found to have the best dust removal efficiency at a water intake level of 1.35 m^(3)/h.Its total dust and respirable dust removal efficiency reached 96.81%and 95.59%,respectively.The air volume was 200.4 m^(3)/min,and the average pressure drop was determined to be 169.4 Pa.In addition,when the wet scrubber with 16 blades was applied in a coal preparation plant in China's Shanxi Province,it was observed that the total dust concentration had fallen below 8.1 mg/m^(3),and the respirable dust concentration had fallen below 5.9 mg/m^(3).Therefore,the results obtained in this research investigation provide important references for the use of wet scrubbers to improve coal production environmental conditions. 展开更多
关键词 Coal mine Coal dust dust removal Performance of wet scrubber
下载PDF
Mechanism of micro-wetting of highly hydrophobic coal dust in underground mining and new wetting agent development 被引量:5
11
作者 Mingzhong Gao Hongmei Li +5 位作者 Yun Zhao Yiting Liu Weiqi Zhou Luming Li Jing Xie Jie Deng 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2023年第1期31-46,共16页
The internal mechanism of the high hydrophobicity of the coal samples from the Pingdingshan mining area was studied through industrial,element,and surface functional group analysis.Laboratory testing and molecular dyn... The internal mechanism of the high hydrophobicity of the coal samples from the Pingdingshan mining area was studied through industrial,element,and surface functional group analysis.Laboratory testing and molecular dynamics simulations were employed to study the impact of three types of surfactants on the surface adsorption properties and wettability of highly hydrophobic bituminous coal.The results show that the surface of highly hydrophobic bituminous coal is compact,rich in inorganic minerals,and poorly wettable and that coal molecules are dominated by hydrophobic functional groups of aromatic rings and aliphatic structures.The wetting performance of surfactants as the intermediate carrier to connect coal and water molecules is largely determined by the interaction force between surfactants and coal(Fs-c)and the interaction force between surfactants and water(Fs-w),which effectively improve the wettability of modified coal dust via modifying its surface electrical properties and surface energy.A new type of wetting agent with a dust removal rate of 89%has been developed through discovery of a compound wetting agent solution with optimal wetting and settling performance.This paper provides theoretical and technical support for removing highly hydrophobic bituminous coal dust in underground mining. 展开更多
关键词 dust removal technology Bituminous coal dust New dust suppressant Mine safety Molecular dynamics
下载PDF
Theoretical and numerical analysis of coal dust separated by centrifugal force for working and heading faces 被引量:7
12
作者 Shiqiang Chen Haiqiao Wang +3 位作者 Yiqun Li Haijiao Cui Jie Zhao Xiaowei Zhang 《International Journal of Coal Science & Technology》 EI CAS 2014年第3期338-345,共8页
In order to meet engineering needs of Chinese underground coal mines,a new dust-collecting fan,a device of dust separated by centrifugal force in driven cyclone passageway(DCCP)was designed.In centrifugal dust removal... In order to meet engineering needs of Chinese underground coal mines,a new dust-collecting fan,a device of dust separated by centrifugal force in driven cyclone passageway(DCCP)was designed.In centrifugal dust removal section(CDRS)of DCCP,a general equation is derived from the principle of force equilibrium.According to CDRS structure parameters and fan running parameters,the general equation is simplified,and the simplest equation is calculated numerically by MATLAB.The calculation results illustrate that increasing quantity of air current is against dust removal,but it is beneficial to dust removal by increasing the radius of driven spiral blade and increasing the particle diameter of coal dust.The conclusions show that the dust-collecting structure parameters coupled with the fan running parameters is a novel optimization approach to dust-collection fan for working and heading faces,which is especially suitable for Chinese underground mines. 展开更多
关键词 Working and heading faces Coal dust removal Centrifugal separation-Driven spiral passageway
下载PDF
Effects of structural and operating parameters of ECP fan on dust particles removed in the transition flow regime 被引量:2
13
作者 Shiqiang Chen Youming Chen +2 位作者 Haiqiao Wang Ronghua Liu Haijiao Cui 《International Journal of Coal Science & Technology》 EI CAS 2014年第4期441-449,共9页
An enclosed cyclone passageway(ECP)dust-collecting fan is discussed.The ECP fan separates dust by centrifugal force originating from a driven spiral airflow,and its design takes the constraints of Chinese underground ... An enclosed cyclone passageway(ECP)dust-collecting fan is discussed.The ECP fan separates dust by centrifugal force originating from a driven spiral airflow,and its design takes the constraints of Chinese underground coal mines into consideration.Using the force equilibrium law,a general equation for dust removal in the centrifugal dust removal section(CDRS)of the ECP fan is deduced.This general equation is simplified using the CDRS structure and the fan operating parameters and is analysed numerically.The attractive results show that increases in the airflow rate of the fan,the structural ratio of the ECPs and the radius of the extended axis can improve the dust removal performance of the CDRS.Furthermore,the effects of the structural ratio and the radius on dust removal dominate over that of the flow rate,and the effect of the structural ratio is more significant than that of the radius. 展开更多
关键词 dust removal Driven spiral airflow Structural and operating parameters ECP fan
下载PDF
Design and Development of a High Efficiency Carbon- Granular Bed Filter in Industrial Scale
14
作者 张济宇 旷戈 林诚 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2004年第3期395-400,共6页
The new dust removal technical route using the carbon-granular bed filter, packed of carbon particles with appropriate grade derive from an online-process vibration sieve, to replace the traditional baggy filter had b... The new dust removal technical route using the carbon-granular bed filter, packed of carbon particles with appropriate grade derive from an online-process vibration sieve, to replace the traditional baggy filter had been developed successfully for capturing the micro-carbon dusts produced from pulverization of petroleum coke, and the green close loop of carbon materials is thus completed in the combined pulverizing and classifying system and pulverized carbon dust removal process. The high dust removal efficiency greater than 99%, low outlet dust concentration less than 100mg·m-3, low pressure drop through dust filtration chamber less than 980Pa, simple and easy design, and flexible and stable operation were achieved also with the carbon-granular bed filter in both bench and industrial scale operations. 展开更多
关键词 carbon-granular bed dust removal outlet dust concentration pressure drop
下载PDF
Enhancement of Cathode Dust Collection and its Application in Improving the Efficiency of Dry Electrostatic Precipitator
15
作者 Wei Wang Zhonghao Wu +1 位作者 Xunqing Xu Biao Xie 《Journal of Electronic Research and Application》 2020年第5期28-32,共5页
As the main equipment of flue gas dedusting in coal fired boiler,electrostatic precipitator(ESP)can meet the requirements of emission standard for air pollutants from coal-fired power plants through improving the effi... As the main equipment of flue gas dedusting in coal fired boiler,electrostatic precipitator(ESP)can meet the requirements of emission standard for air pollutants from coal-fired power plants through improving the efficiency of ESP and combining with desulfurization system while not installing wet ESP(WESP).This paper introduces the modifications of ESP cathode structure to improve the efficiency of dust collection by reducing the secondary dust loss at cathode.The application of cathode dust collection provides a reference for the improvement of ESP dust collection efficiency. 展开更多
关键词 ESP dust removal efficiency improvement Cathode dust collection
下载PDF
Diffusion and adoption of environmentally sound technology in China cement industry 被引量:1
16
作者 Cai Ning Economics Department, Zhejiang University, Hangzhou 310027, China 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1997年第3期68-75,共8页
From rapid growth of cement industry in China there is serious pollution of powdered dust. After general analysis on factors influencing adoption of environmentally sound technology(EST) as well as economic benefit ... From rapid growth of cement industry in China there is serious pollution of powdered dust. After general analysis on factors influencing adoption of environmentally sound technology(EST) as well as economic benefit from adoption of dust removing technology and capital ability of cement firms to invest, the conclusion that the obstacles to EST in China cement sector are different from ones in other sectors was drawn. And then, hindrances to diffusion and adoption of EST in China cement were discussion by empirical study. 展开更多
关键词 dust removing technology DIFFUSION hindrance cement industry.
下载PDF
The Application of Cold Banding Technology for Dust Removed From BOF Gas Using Dry Dedusting Technology
17
作者 Tang Weijun Zhang Yong Ma Gangping 《Meteorological and Environmental Research》 CAS 2015年第1期14-16,共3页
Firstly, physical and chemical properties of dust removed from BOF gas are analyzed, and then the cold banding technology of dust removed from BOF gas and its application are introduced. Tests have proved that using c... Firstly, physical and chemical properties of dust removed from BOF gas are analyzed, and then the cold banding technology of dust removed from BOF gas and its application are introduced. Tests have proved that using cooled agglomerated pellets made of the dust removed from BOF gas and small amounts of modified starch as a coolant and slagging agent in steel production can bring about considerable economic, social and environmental benefits. 展开更多
关键词 BOF gas dust removed from BOF gas using dry dedusting technology Cold banding Steelmaking China
下载PDF
Removal of dust from flue gas in magnetically stabilized fluidized bed 被引量:9
18
作者 Yinghui Wang Keting Gui +1 位作者 Mingheng Shi Changfeng Li 《Particuology》 SCIE EI CAS CSCD 2008年第2期116-119,共4页
A magnetically stabilized fluidized bed (MSFB,Ф 500mm×2100mm) was designed to study dust removal from flue gas. Based on the mechanism of dust removal in a fixed bed, the effects on collection efficiency of ma... A magnetically stabilized fluidized bed (MSFB,Ф 500mm×2100mm) was designed to study dust removal from flue gas. Based on the mechanism of dust removal in a fixed bed, the effects on collection efficiency of magnetic field intensity, ratio of flue gas velocity to minimum fluidization velocity, bed height, and particle average diameter, were investigated. Then feasible methods for MSFB to better remove dust were proposed. Over 95 % of dust removal with MSFB can be achieved, when stable fluidization is maintained and when magnetic particles are frequently renewed. 展开更多
关键词 Magnetically stabilized fluidized bed (MSFB) Stable fluidization dust removal Magnetic particles renewal
原文传递
Numerical simulation and experimental study of gas cyclone–liquid jet separator for fine particle separation
19
作者 Liwang Wang Erwen Chen +5 位作者 Liang Ma Zhanghuang Yang Zongzhe Li Weihui Yang Hualin Wang Yulong Chang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2022年第11期43-52,共10页
To address the shortcomings of existing particulate matter trapping technology,especially the low separation efficiency of fine particles,herein,a novel gas cyclone-liquid jet separator was developed to research fine ... To address the shortcomings of existing particulate matter trapping technology,especially the low separation efficiency of fine particles,herein,a novel gas cyclone-liquid jet separator was developed to research fine particle trapping.First,numerical simulation methods were used to investigate the flow field characteristics and dust removal efficiency of the separator under different working conditions,and to determined suitable experimental conditions for subsequent dust removal experiments.Afterward,the separation efficiency of the separator against five kinds of common particles,including g-C_(3)N_(4),TiO_(2),SiC,talc,and SiO_(2),was experimentally studied.A maximum separation efficiency of 99.48%was achieved for particles larger than 13.1μm,and 96.55%efficiency was achieved for particles larger than 2μm.The best crushing atomization effect was achieved for the separator when uGwas 10 m·s^(-1)and uLwas 3 m·s^(-1),while the best separation effect was achieved when uGwas 10 m·s^(-1)and uLwas 3.75 m·s^(-1).Studies have shown that the gas cyclone-liquid jet separator has excellent applicability in the separation of fine particles. 展开更多
关键词 Gas cyclone-liquid jet dust removal Fine particles Numerical simulation
下载PDF
An air cleaner for road tunnels
20
作者 雷玉勇 《Journal of Chongqing University》 CAS 2003年第1期13-16,共4页
an air cleaner employing pulse induced plasma chemical process to remove dust and carbon monoxide (CO) in road tunnels is presented, which is composed of mainly a precipitator, a reactor, a flow control system, a powe... an air cleaner employing pulse induced plasma chemical process to remove dust and carbon monoxide (CO) in road tunnels is presented, which is composed of mainly a precipitator, a reactor, a flow control system, a power supply and a measurement system. Its performances are studied in simulated air conditions. It is found that the rate of dust removal is dependent on the voltage of the pulse power, the distance between the two dust collecting plates of the electrostatic precipitator, the effective length of the precipitator and the air flow rate in the precipitator, and that of CO removal is affected by the voltage and frequency of the super pulse power, the air flow rate in the reactor and the relative humidity of air. Applying such an cleaner of a proper design to the treatment of polluted air at a flow rate of 7 m/s can achieve the rate of dust removal up to 93 % and that of CO removal up to 72.6 %, which efficiently controls the concentrations of CO and dust under allowable limits. It is implied that the proposed air cleaner is a potential solution to air control in road tunnels, and is prominent for its performances and saving the huge cost of longitudinal ventilation tunnel or vertical vent and ventilation facilities. 展开更多
关键词 air pollution air pollution control dust removal road tunnel CO removal
下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部