In the discharge of EAST tokamak, it is observed that (2, 1) neoclassical tearing mode (NTM) is triggered by mode coupling with a (1, 1) internal mode. Using singular value decomposition (SVD) method for soft ...In the discharge of EAST tokamak, it is observed that (2, 1) neoclassical tearing mode (NTM) is triggered by mode coupling with a (1, 1) internal mode. Using singular value decomposition (SVD) method for soft X-ray emission and for electron cyclotron emission (ECE), the coupling spatial structures and coupling process between these two modes are analyzed in detail. The results of SVD for ECE reveal that the phase difference between these two modes equals to zero. This is consistent with the perfect coupling condition. Finally, performing statistical analysis of r1/1, ξ1/1 and w2/1, we find that r1/1 more accurately represents the coupling strength than ξ1/1, and r1/1 is also strongly related to the (2, 1) NTM triggering, where r1/1 is the width of (1, 1) internal mode, ξ1/1 is the perturbed amplitude of (1, 1) internal mode, and w2/1 denotes the magnetic island width of (2, 1) NTM.展开更多
电厂电气监控系统(electrical control system,ECS)的发展高度依赖于通信组网技术,系统的实时性、可靠性、可维护性与ECS的组网模式及其与分散控制系统(distributed control system,DCS)的接入方式密切相关。文章介绍了ECS的一般组成,...电厂电气监控系统(electrical control system,ECS)的发展高度依赖于通信组网技术,系统的实时性、可靠性、可维护性与ECS的组网模式及其与分散控制系统(distributed control system,DCS)的接入方式密切相关。文章介绍了ECS的一般组成,分析对比了间隔层与通信管理层之间的2种不同组网模式,即面向电气间隔的组网模式和面向过程的组网模式。并比较了ECS与DCS的常用接入方式,指出面向电气间隔的组网模式以及ECS与DCS混合连接运行模式比其他模式更具优势。展开更多
基金supported by the National Magnetic Confinement Fusion Science Program of China(Nos.2014GB103000,2011GB101000 and2013GB102000)sponsored in part by National Natural Science Foundation of China(Nos.10725523,10990212 and 11205199)
文摘In the discharge of EAST tokamak, it is observed that (2, 1) neoclassical tearing mode (NTM) is triggered by mode coupling with a (1, 1) internal mode. Using singular value decomposition (SVD) method for soft X-ray emission and for electron cyclotron emission (ECE), the coupling spatial structures and coupling process between these two modes are analyzed in detail. The results of SVD for ECE reveal that the phase difference between these two modes equals to zero. This is consistent with the perfect coupling condition. Finally, performing statistical analysis of r1/1, ξ1/1 and w2/1, we find that r1/1 more accurately represents the coupling strength than ξ1/1, and r1/1 is also strongly related to the (2, 1) NTM triggering, where r1/1 is the width of (1, 1) internal mode, ξ1/1 is the perturbed amplitude of (1, 1) internal mode, and w2/1 denotes the magnetic island width of (2, 1) NTM.
文摘电厂电气监控系统(electrical control system,ECS)的发展高度依赖于通信组网技术,系统的实时性、可靠性、可维护性与ECS的组网模式及其与分散控制系统(distributed control system,DCS)的接入方式密切相关。文章介绍了ECS的一般组成,分析对比了间隔层与通信管理层之间的2种不同组网模式,即面向电气间隔的组网模式和面向过程的组网模式。并比较了ECS与DCS的常用接入方式,指出面向电气间隔的组网模式以及ECS与DCS混合连接运行模式比其他模式更具优势。