The first laboratory of electromagnetic compatibility in Chinais possessed of vivid characteristics in respect of design and configurationof testing equipment. It has successively completed some testing projectsand wi...The first laboratory of electromagnetic compatibility in Chinais possessed of vivid characteristics in respect of design and configurationof testing equipment. It has successively completed some testing projectsand will unfold a more extensive range of measurement and test works inthe days to come.[展开更多
In this paper, coupling the quasi-3D numerical simulation of electromagnetic field and the experiments of continuous casting with soft-contacted mould with some metals such as tin, aluminum, copper and steel, the elec...In this paper, coupling the quasi-3D numerical simulation of electromagnetic field and the experiments of continuous casting with soft-contacted mould with some metals such as tin, aluminum, copper and steel, the electromagnetic characteristics of continuous casting with soft-contacted mould is analyzed. It is shown that the electromagnetic pressure on the surface of billet is increasing with the rising of power frequency as a logarithmically parabolic function, with that of electric conductivity of billet as a power junction, and with that of the current in inductor as a parabolic junction.展开更多
Electromagnetic relay is a widely used apparatus which usually works in a magnetic disturbance environment. To evaluate its electromagnetic compatibility (EMC) in a static magnetic field, dynamic characteristics of a ...Electromagnetic relay is a widely used apparatus which usually works in a magnetic disturbance environment. To evaluate its electromagnetic compatibility (EMC) in a static magnetic field, dynamic characteristics of a clapper relay in a uniform static magnetic field situation based on the finite element method (FEM) is studied. Influences of the magnetic field on dynamic parameters (delay time, pick-up time, end pressure, and final velocity) as well as a situation in which the relay cannot function normally are analyzed. Simulation reveals that the external magnetic field which weakens the relay’s air-gap field has a greater influence on the relay’s dynamic parameters than the one strengthening the field. The validity of the simulation is verified by measured results of coil current and armature displacement.展开更多
This study deals with a new evaluation method of nuclear electromagnetic pulse (NEMP) vulnerability on cots electronic equipments. The method consists in comparing electromagnetic compatibility (EMC) test severiti...This study deals with a new evaluation method of nuclear electromagnetic pulse (NEMP) vulnerability on cots electronic equipments. The method consists in comparing electromagnetic compatibility (EMC) test severities to NEMP conducted stresses. The comparison uses five characteristic criteria of the induced stresses, calculated with an analytic method. The process is based on a software named "SUSIE" (in French: SUSceptibilite a I'IEMN "Impulsion ElectroMagnttique d'origine Nucl6aire Haute Altitude"). Today, only conducted stresses are analyzed. An evolution is planned in 2013 to determine the equivalent vulnerability of radiated stresses and to validate the software.展开更多
It is urgent to solve various problems in electromagnetic (EM) engineering under the increasingly complicated environment. Some expert systems (ES) come into being just to keep up with the demand for solving these...It is urgent to solve various problems in electromagnetic (EM) engineering under the increasingly complicated environment. Some expert systems (ES) come into being just to keep up with the demand for solving these problems. Combined with the analysis of development orES technology and the development trend of EM engineering software in recent years, the application orES technology in EM engineering is discussed, and especially the progress of complete ES in electromagnetic compatible (EMC) is introduced.展开更多
文摘The first laboratory of electromagnetic compatibility in Chinais possessed of vivid characteristics in respect of design and configurationof testing equipment. It has successively completed some testing projectsand will unfold a more extensive range of measurement and test works inthe days to come.[
文摘In this paper, coupling the quasi-3D numerical simulation of electromagnetic field and the experiments of continuous casting with soft-contacted mould with some metals such as tin, aluminum, copper and steel, the electromagnetic characteristics of continuous casting with soft-contacted mould is analyzed. It is shown that the electromagnetic pressure on the surface of billet is increasing with the rising of power frequency as a logarithmically parabolic function, with that of electric conductivity of billet as a power junction, and with that of the current in inductor as a parabolic junction.
基金Project (No. 513230502) supported by the PLA General ArmamentDepartment of China
文摘Electromagnetic relay is a widely used apparatus which usually works in a magnetic disturbance environment. To evaluate its electromagnetic compatibility (EMC) in a static magnetic field, dynamic characteristics of a clapper relay in a uniform static magnetic field situation based on the finite element method (FEM) is studied. Influences of the magnetic field on dynamic parameters (delay time, pick-up time, end pressure, and final velocity) as well as a situation in which the relay cannot function normally are analyzed. Simulation reveals that the external magnetic field which weakens the relay’s air-gap field has a greater influence on the relay’s dynamic parameters than the one strengthening the field. The validity of the simulation is verified by measured results of coil current and armature displacement.
文摘This study deals with a new evaluation method of nuclear electromagnetic pulse (NEMP) vulnerability on cots electronic equipments. The method consists in comparing electromagnetic compatibility (EMC) test severities to NEMP conducted stresses. The comparison uses five characteristic criteria of the induced stresses, calculated with an analytic method. The process is based on a software named "SUSIE" (in French: SUSceptibilite a I'IEMN "Impulsion ElectroMagnttique d'origine Nucl6aire Haute Altitude"). Today, only conducted stresses are analyzed. An evolution is planned in 2013 to determine the equivalent vulnerability of radiated stresses and to validate the software.
基金the Key Project of Chinese Ministry of Education (No. 104166)
文摘It is urgent to solve various problems in electromagnetic (EM) engineering under the increasingly complicated environment. Some expert systems (ES) come into being just to keep up with the demand for solving these problems. Combined with the analysis of development orES technology and the development trend of EM engineering software in recent years, the application orES technology in EM engineering is discussed, and especially the progress of complete ES in electromagnetic compatible (EMC) is introduced.