期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Management of multiple type II endoleaks detected by duplex ultrasound after endovascular abdominal aneurysm repair
1
作者 GUO Da-qiao LI Wei-miao JIANG Jun-hao SHI Zhen-yu WANG Yu-qi FU Wei-guo 《Chinese Medical Journal》 SCIE CAS CSCD 2012年第15期2781-2783,共3页
We reported a case of multiple type II endoleaks detected by duplex ultrasound after endovascular abdominal aneurysm repair. The patient was undergoing warfarin therapy. Duplex ultrasound was applied as the sole surve... We reported a case of multiple type II endoleaks detected by duplex ultrasound after endovascular abdominal aneurysm repair. The patient was undergoing warfarin therapy. Duplex ultrasound was applied as the sole surveillance method during follow-up and provided the concerned information for reintervention. The endoleaks were successfully repaired by coil embolization of the collaterals from the internal lilac artery feeding the fourth lumbar artery. 展开更多
关键词 multiple type H endoleaks duplex ultrasound endovascular abdominal aneurysm repair
原文传递
Contrast-enhanced Ultrasound in Detecting Endoleaks with Failed Computed Tomography Angiography Diagnosis after Endovascular Abdominal Aortic Aneurysm Repair 被引量:8
2
作者 Xiao Yang Yue-Xin Chen +5 位作者 Bo Zhang Yu-Xin Jiang Chang-Wei Liu Rui-Na Zhao Qiong Wu Da-Ming Zhang 《Chinese Medical Journal》 SCIE CAS CSCD 2015年第18期2491-2497,共7页
Background: Endovascular aneurysnl repair (EVAR) is one of the first-line therapies of abdominal aortic aneurysms. Postoperative endoleak is the most common complication of EVAR. Computed tomography angiography (... Background: Endovascular aneurysnl repair (EVAR) is one of the first-line therapies of abdominal aortic aneurysms. Postoperative endoleak is the most common complication of EVAR. Computed tomography angiography (CTA), which is routine for follow-up, has side effects (e.g., radiation) and also has a certain percentage of missed diagnosis. Preliminary studies on contrast-enhanced ultrasound (CEUS) have shown that the sensitivity of CEUS for detecting endoleak is no lower than that of CTA. To investigate the advantages of CEUS, we conducted CEUS examinations of post-EVAR cases in which CTA failed to detect endoleak or could not verify the type of endoleak. Methods: Post-EVAR patients, who were clinically considered to have endoleak and met the inclusion criteria were enrolled between March 2013 and November 2014. All of the patients underwent color Doppler flow imaging (CDFI) and a CEUS examination. Size, location, microbubble dispersion, and hemodynamic characteristics of leaks were recorded. Comparison between the diagnosis of CEUS and CDF1 was conducted using Fisher's exact test and clinical outcomes of all patients were followed up. Results: Sixteen patients were enrolled, and 12 (75%) had endoleaks with verified types by CEUS. Among 12 cases of endoleaks were positive by CEUS, 10 were CDFl-positive, and the four CEUS-negative cases were all negative by CDFI. The diagnostic values of CEUS and CDFI were statistically difl'erent (P = 0,008). Six patients with high-pressure endoleaks received endovascular re-intervention guided by CEUS results. One patient with type Ⅲ endoleak had open surgery when endovascular repair failed. Conclusions: C EUS is a new, safe, and effective means for detection ofendoleaks post-EVAR. This technique can be used as a supplement for routine CTA follow-up to provide more detailed information on endoleak and its category. 展开更多
关键词 Abdominal Aortic Aneurysnl: Color Doppler Flow Imaging Contrast-enhanced Ultrasound: Endoleak EndovascularAneurysm Repair
原文传递
Safety and Efficacy of Endovascular Aortic Repair for Abdominal Aortic Aneurysms with a Hostile Neck Anatomy
3
作者 Zun-xiang KE Ge-zheng CHEN +6 位作者 Ke HU Shan ZHANG Peng ZHOU Dian-xi CHEN Yi-qing LI Qin LI Chao YANG 《Current Medical Science》 SCIE CAS 2023年第6期1221-1228,共8页
Objective This study aimed to investigate the safety and efficacy of endovascular aortic repair(EVAR)for the treatment of an abdominal aortic aneurysm(AAA)with a hostile neck anatomy(HNA).Methods From January 1,2015 t... Objective This study aimed to investigate the safety and efficacy of endovascular aortic repair(EVAR)for the treatment of an abdominal aortic aneurysm(AAA)with a hostile neck anatomy(HNA).Methods From January 1,2015 to December 31,2019,a total of 259 patients diagnosed with an AAA who underwent EVAR were recruited into this study.Based on the morphological characteristics of the proximal neck anatomy,the patients were divided into the HNA group and the friendly neck anatomy(FNA)group.The patients were followed up for up to 4 years.Results The average follow-up time was 1056.1±535.5 days.Type I endoleak occurred in 4 patients in the HNA group,and 2 patients in the FNA group.Neither death nor intraoperative switch to open repair occurred in either group.The time of the operation was significantly longer in the HNA group(FNA vs.HNA,99.2±51.1 min vs.117.5±63.8 min,P=0.011).There were no significant differences in short-term clinical success rate(P=0.228)or midterm clinical success rate(P=0.889)between the two groups.The overall mortality rate was 10.4%,and Kaplan-Meier survival analysis indicated that the two groups had similar cumulative survival rates at the end of the follow-up period(P=0.889).Conclusion EVAR was feasible and safe in patients with an AAA with a proximal HNA.The early and midterm results were promising;however,further studies are needed to verify the long-term effectiveness of EVAR. 展开更多
关键词 abdominal aortic aneurysm hostile aneurysm neck endovascular aortic repair ENDOLEAK PROGNOSIS
下载PDF
Efficacy of Willis covered stent of intracranial pseudoaneurysms in the internal carotid artery: A systematic review and meta-analysis
4
作者 Li Lin Shao-Wei Xiang +8 位作者 Yan-Ling Sun Yuan Chen Zhe Wu Zhi-Feng Ning Ding-Wen Shen Xue-Qin Sima Qi-Qiang Wen Gui-Lai Wei Qing-Yong He 《Journal of Acute Disease》 2023年第5期173-178,共6页
Objective:To evaluate the efficacy of a novel coated stent in the treatment of intracranial pseudoaneurysm.Methods:MEDLINE,EMBASE,and PubMed databases were searched for literature published between 1990 and April 2022... Objective:To evaluate the efficacy of a novel coated stent in the treatment of intracranial pseudoaneurysm.Methods:MEDLINE,EMBASE,and PubMed databases were searched for literature published between 1990 and April 2022 according to PRISMA guidelines.All studies with≥10 patients reporting successful implantation of Willis covered stent,therapeutic effect,complications,and postoperative follow-up were included.The combined incidence and corresponding 95%confidence intervals were assessed using a generalized linear mixed method and random effects model.Results:Five studies(116 patients with pseudoaneurysms)were included.The experimental groups in the selected studies showed a combined technical success rate of 81.03%(OR=18.31,95%CI=9.39-35.69,I^(2)=79%,P<0.001).Clinical follow-up showed that the complete cure rate was as high as 94.4%after the follow-up(OR=106.81,95%CI=39.08-291.88,I^(2)=0%,P=0.71).Conclusions:Willis covered stent is feasible,safe,and effective in the treatment of intracranial pseudoaneurysm. 展开更多
关键词 Intracranial pseudoaneurysms Willis covered stent Systematic review META-ANALYSIS Internal carotid artery ENDOLEAK NEUROSURGERY
下载PDF
Endovascular treatment of paravisceral mycotic aneurysm: Chimmeny endovascular sealing the end of de road
5
作者 Martin Rabellino Pedro N Moltini +3 位作者 Vanesa G Di Caro Jose G Chas Ricardo Marenchino Ricardo D Garcia-Monaco 《World Journal of Cardiology》 CAS 2017年第7期629-633,共5页
Open surgery is the elective treatment for mycotic aneurysms of the aorta. This surgery consists of resection of the aneurysm, debridement and revascularization with an in situ or extra-anatomic bypass. Even when surg... Open surgery is the elective treatment for mycotic aneurysms of the aorta. This surgery consists of resection of the aneurysm, debridement and revascularization with an in situ or extra-anatomic bypass. Even when surgery has been successful, the morbimortality is raised and the endovascular treatment has become an alternative for specific patients. When mycotic aneurysms involved the visceral arteries, more complex techniques are necessary such as fenestrated endovascular aortic repair or chimmeny endovascular aortic repair and the most frequent complications of this are endoleaks and oclussion the visceral arteries. We present a case of a pacient with a paravisceral abdominal mycotic aneurysms that was result with 2 chimney technique(in the right renal and superior mesenteric arteries) and a single Nellix EVAS(Endologix, Irvine, Calif) of 12 cm long without evidence of endoleaks in the follow-up. 展开更多
关键词 Mycototic aneurysms Edovascular repair AORTA endoleaks Para visceral aneurysms
下载PDF
Transarterial Embolization versus Translumber Embolization for Type Ⅱ Endoleak after Endovascular Abdomi nal Aortic Aneurysm Repair:A Meta-Analysis 被引量:3
6
作者 Xu Zhang Lei Ji +2 位作者 Mengyin Chen Wei Wang Yuehong Zheng 《Chinese Medical Sciences Journal》 CAS CSCD 2020年第2期135-141,共7页
Objective Type II endoleak is the most common subtype of endoleak as a complication after endovascular aneurysm repair(EVAR).The efficacy of transarterial(TA)embolization and translumber(TL)embolization in the managem... Objective Type II endoleak is the most common subtype of endoleak as a complication after endovascular aneurysm repair(EVAR).The efficacy of transarterial(TA)embolization and translumber(TL)embolization in the management of type II endoleak remains equipoise.The aim of this study is to compare the technical and clinical success between TA embolization andTL embolization for type II endoleak after EVAR.Methods The protocol was registered(CRD 42018114453)and the electronic databases(Pubmed,Embase,Web of Science,and Cochrane)were systematically searched till March 2019.The search terms included EVAR,type II endoleak,and embolization.The articles were read and extracted by two authors independently to include randomized control trails and retrospective studies that compared TA embolization and TL embolization in patients who developed type II endoleak after EVAR.The technical and clinical success rates were metaanalyzed with random effect model.Results A total of 6 articles with 268 patients and 290 type II endoleaks were included.The pooled odds ratio(OR)of technical success rate for TA vs.TL was 0.56(95%C7,0.10-3.18;P=0.51)and the pooled OR of clinical success rate for TA vs.TL was 0.31(95%CI,0.07-1.29;P=0.11).As a limitation,6 articles were all retrospective studies which may lead to bias.Conclusion Both TA.andTL could be eflective procedure of embolizations to resolve the type II endoleak.The metaanalysis result indicated that TA embolization was not inferior toTL embolization in technical success and clinical success. 展开更多
关键词 ENDOLEAK endovascular aneurysm repair EMBOLIZATION abdominal aortic aneurysm META-ANALYSIS
下载PDF
Midterm results of periprosthetic coiling embolization in high-risk patients 被引量:4
7
作者 Xiantao Li Yanyan Huang Pingfan Guo 《Journal of Interventional Medicine》 2019年第4期160-163,共4页
Background:With increasing interest in the prevention of typeⅡendoleaks(EⅡ),the aim of this study was to report midterm results on the intraoperative coiling embolization of the periprosthetic aneurysmal sac in pati... Background:With increasing interest in the prevention of typeⅡendoleaks(EⅡ),the aim of this study was to report midterm results on the intraoperative coiling embolization of the periprosthetic aneurysmal sac in patients at high-risk of EⅡ.Methods:A retrospective review study was conducted with 124 patients with infrarenal abdominal aortic aneurysm who accorded with the inclusion criteria,including 66 patients who underwent standard endovascular aortic aneurysm repair(Group A)and 58 patients who underwent aneurysmal sac coiling embolization(Group B).Baseline data and follow-up results were analyzed.Results:A mean of 2.84±1.45 coils(range 1-9)were used in Group B.The general incidence of an EⅡwas 15.32%(19/124)at a mean follow-up time of 46.60±15.14 months,with 22.7%(15/66)in Group A and 6.9%(4/58)in Group B(χ~2=5.62;P=0.018).Logistic multivariate analysis revealed that the independent risk factors of an EII were no sac embolization and a sac volume≥128 cm^3.The Kaplan-Meier subgroup analysis showed no difference in regard to the rate of freedom from EⅡbetween the two groups either with a larger or smaller sac.Conclusions:These results suggest that periprosthetic coiling embolization in patients at high-risk of EⅡis safe and effective in the prevention of EⅡ.The preventive effect seemed to be weakened when the sac volumes were taken into consideration at midterm follow-up. 展开更多
关键词 Aortic ANEURYSM Abdominal Radiology INTERVENTIONAL ENDOLEAK Risk assessment
下载PDF
Endoleak management and postoperative surveillance following endovascular repair of internal carotid artery vascular diseases using Willis covered stent 被引量:1
8
作者 Lin Ma Shuo Yan +3 位作者 Hao Feng Jichong Xu Huaqiao Tan Chun Fang 《Journal of Interventional Medicine》 2021年第4期212-218,共7页
Background:To report the clinical results and experiences of endoleak management and postoperative surveillance following endovascular repair of internal carotid artery vascular diseases(ICAVDs)using Willis covered st... Background:To report the clinical results and experiences of endoleak management and postoperative surveillance following endovascular repair of internal carotid artery vascular diseases(ICAVDs)using Willis covered stents.METHODS:Seventy-three patients with ICAVD who received Willis covered stent implantation between November 2013 and September 2018 were retrospectively reviewed.The clinical data of endoleak management and postoperative surveillance were analyzed.RESULTS:Seventy-three cases with ICAVD,including 57 aneurysms,11 carotid-cavernous sinus fistulas(CCF),and 5 surgical injuries,were all successfully installed with covered stents.Total isolation of ICAVDs was achieved in 59 patients(80.8%),and endoleaks were observed in 14 patients(19.2%).Of the 14 patients with endoleaks,12 had type I endoleaks and 2 had type II;13 had aneurysms and one had CCF.10 patients with type I endoleaks received balloon dilatation,and 7 of them underwent a second stent-graft implantation after then.One patient with type II endoleak received embolization of the branch artery,and another one received follow-up observation.Endoleaks resolved in 6 patients and were minimal in 5 patients after balloon dilatation or the second stent implantation.During the follow-up period,minor endoleaks spontaneously resolved in 4 patients and minimal endoleaks were still demonstrated in 4 patients without enlargement of residual lumen and rupture.CONCLUSIONS:Endoleaks are the major complication after endovascular repair of ICAVDs and represent one of the limitations of this procedure.Improving the understanding and management of endoleaks can be beneficial in the clinical setting,including the popularization and application of this technique. 展开更多
关键词 Covered stent Endovascular repair Internal carotid artery ENDOLEAK
下载PDF
Rupture of an Infrarenal Aortic Aneurysm Due to a Secondary Type 1a Endoleak Following Endovascular Aneurysm Sealing with the Nellix<sup>&reg;</sup>Device
9
作者 Kudla Dorothea Uhl Christian +2 位作者 Zorger Niels Steinbauer Markus Topel Ingolf 《Surgical Science》 2019年第11期398-404,共7页
Purpose: The Nellix endovascular aneurysm sealing (EVAS) system was introduced in 2010 for infrarenal abdominal aortic aneurysm (AAA) repair. So far one secondary type 1a endoleak resulting in rupture of the aneurysm ... Purpose: The Nellix endovascular aneurysm sealing (EVAS) system was introduced in 2010 for infrarenal abdominal aortic aneurysm (AAA) repair. So far one secondary type 1a endoleak resulting in rupture of the aneurysm has been reported. Case report: We present a case of a rupture of an infrarenal aortic aneurysm due to a secondary type 1a endoleak caused by stent migration 14 months after endovascular aneurysm sealing with a Nellix system. Conclusion: Strict adherence to anatomical requirements given by the instructions for use during patient selection and thorough post interventional surveillance may reduce the probability of secondary type 1a endoleaks. Furthermore, device design changes, especially concerning the configuration of the proximal part of the stent graft, have to be considered. 展开更多
关键词 ENDOVASCULAR ANEURYSM SEALING SECONDARY Type 1a ENDOLEAK RUPTURE Abdominal Aortic ANEURYSM
下载PDF
Delayed type lllb endoleak using Anaconda^TM stent graft in abdominal aortic aneurysm repair
10
作者 WU Zi-heng Dieter Raithel QU Le-feng 《Chinese Medical Journal》 SCIE CAS CSCD 2010年第18期2623-2624,共2页
Endoleaks are defined as the persistence of blood flow outside the lumen of the endoluminal graft but within an aneurysm sac or the adjacent vascular segment being treated by the graft and classified into 5 categories.
关键词 type endoleak endovascular aortic aneurysm repair COMPLICATION fabric tears
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部