期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Apoptosis of rabbit retinal cell after eyeball rupture
1
作者 Xue-Min Tian Yu Zhu 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2013年第4期273-279,共7页
Objective:To establish rabbit eyeball rupture model by air gun in order to observe and analyze the early injury condition and reasons of retinal cell after eyeball rupture.Methods:Forty eight healthy rabbits were rand... Objective:To establish rabbit eyeball rupture model by air gun in order to observe and analyze the early injury condition and reasons of retinal cell after eyeball rupture.Methods:Forty eight healthy rabbits were randomly divided into control group and 1,3,6,12 and 24 h after injury groups.After anesthesia,the rabbit eyeball rupture model was established by air gun. Then the early pathological changes of rabbit retina were observed,and apoptotic index(Al), oncosis index(OI),the relationship between the expression amounts of apoptosis-related genes and Al were analyzed.Results:Obvious pathological lesion appeared in retina 6 h after injury. Irreversible damage occurred 12-24 h after injury.The results of AI and OI indicated that the OI peak appeared 6 h after injury and then gradually declined,while the AI increased with the prolongation of time,and the AI was higher than OI in 12 h after injury.Immunohistochemical results indicated that there was no obvious bcl-2 protein expression change.Compared with the control group and the 3,6,12 and 24 h after the injury groups,the expressions of p53 and Caspase-3 were significandy improved and peaked at 12 h(P【0.01).Positive correlation existed among p53,Caspase-3 expression amount and cell apoptosis amount.Conclusions:Apoptosis and oncosis of visual cells are the main reasons of retinal cell injury.p53 and Caspase-3 are the important factors in promoting the retinal cell apoptosis after eyeball rupture. 展开更多
关键词 RABBIT eyeball RUPTURE RETINOPATHY Cell APOPTOSIS bcl-2 p53 CASPASE-3
下载PDF
莎士比亚与英语词汇(33)
2
作者 杨俊峰 《英语知识》 2005年第9期26-27,共2页
关键词 莎士比亚 英语 词汇 eyeball farmhouse 词义 用法
下载PDF
Efficacy of intraorbital electroacupuncture for diabetic abducens nerve palsy: study protocol for a prospective single-center randomized controlled trial 被引量:9
3
作者 Ling-yun Zhou Xue-mei Li +5 位作者 Tie-juan Liu Xiao-jie Ji Ming Zhao Chang Su Ji-chao Liu Jiang-yun Sun 《Neural Regeneration Research》 SCIE CAS CSCD 2017年第5期826-830,共5页
Abducens nerve palsy(ANP) is commonly seen in patients with diabetes mellitus. The validity of acupuncture as a traditional Chinese medicine method in peripheral nerve repair is well established. However, its effica... Abducens nerve palsy(ANP) is commonly seen in patients with diabetes mellitus. The validity of acupuncture as a traditional Chinese medicine method in peripheral nerve repair is well established. However, its efficacy in randomized controlled trials remains unclear. Herein, we designed a protocol for a prospective, single-center, randomized controlled trial to investigate the effect of intraorbital electroacupuncture on diabetic ANP. We plan to recruit 60 patients with diabetic ANP, and randomly divide them into treatment and control groups. Patients in both groups will continue their glucose-lowering therapy. A neural nutrition drug will be given to both groups for six weeks. The treatment group will also receive intraorbital electroacupuncture therapy. We will assess efficacy of treatment, eyeball movement, diplopia deviation and the levels of fasting blood-glucose and glycosylated hemoglobin before treatment at 2, 4, and 6 weeks after treatment. The efficacy and recurrence will be investigated during follow-up(1 month after intervention). This protocol was registered at Chinese Clinical Trial Registry on 16 January 2015(Chi CTR-IPR-15005836). This study was approved by the Ethics Committee of First Affiliated Hospital of Harbin Medical University of China(approval number: 201452). All protocols will be in accordance with Declaration of Helsinki, formulated by the World Medical Association. Written informed consent will be provided by participants. We envisage that the results of this clinical trial will provide evidence for promoting clinical use of this new therapy for management of ANP. 展开更多
关键词 nerve regeneration sixth cranial nerve peripheral nerve injury ELECTROACUPUNCTURE diabetes mellitus eyeball movement DIPLOPIA rehabilitation ocular motility disorder intervention randomized controlled trail neural regeneration
下载PDF
Validity and reliability of the Ocular Motor Nerve Palsy Scale 被引量:5
4
作者 Ling-Yun Zhou Chang Su +1 位作者 Tie-Juan Liu Xue-Mei Li 《Neural Regeneration Research》 SCIE CAS CSCD 2018年第10期1851-1856,共6页
Objective and accurate assessment of the degree of ocular motor nerve palsy is helpful not only in the evaluation of prognosis, but also for the screening of treatment methods. However, there is currently no comprehen... Objective and accurate assessment of the degree of ocular motor nerve palsy is helpful not only in the evaluation of prognosis, but also for the screening of treatment methods. However, there is currently no comprehensive measure of its severity. In this study, we designed the Ocular Motor Nerve Palsy Scale and investigated its validity and reliability. Six experts were invited to grade and evaluate the scale. The study recruited 106 patients with a definite diagnosis of unilateral isolated ocular motor nerve palsy. Three physicians evaluated the patients using the scale. One of the three physicians evaluated the patients again after 24 hours. The content validity index(CVI) and factor analysis were used to analyze the scale's construct validity. The intraclass correlation coefficient and Cronbach's alpha were used to evaluate the inter-rater and test-retest reliability and the internal consistency. The CVI results(I-CVI = 1.0, S-CVI = 0.9, Pc = 0.016, K* = 1) indicated good content validity. Factor analysis extracted two common factors that accounted for 85.2% of the variance. Furthermore, the load value of each component was above 0.8, indicating good construct validity. The Ocular Motor Nerve Palsy Scale was found to be highly reliable, with an inter-rater reliability intraclass correlation coefficient of 0.965(P 0.01), a test-retest reliability intraclass correlation coefficient of 0.976(P 0.01), and Cronbach's alpha values of 0.63–0.70. In conclusion, the Ocular Motor Nerve Palsy Scale with good validity and reliability can be used to quantify the severity of ocular motor nerve palsy. This study was registered at Chinese Clinical Trial Registry(registration number: Chi CTR-OOC-17010702). 展开更多
关键词 nerve regeneration Ocular Motor Nerve Palsy Scale oculomotor nerve paralysis abducens nerve paralysis trochlear nerve paralysis validity reliability internal consistency diplopia eyeball movement disorder ptosis neural regeneration
下载PDF
Health benefits of black rice——A review 被引量:7
5
作者 Balasubramaniam Jaya Prasad Pazhaniyandi Subramania Sharavanan Rengaraj Sivaraj 《Grain & Oil Science and Technology》 2019年第4期109-113,共5页
Rice has been a staple food across the globe since time immemorial.Generally,different types of rice,such as white,purple,red,brown,and black rice,are named following the physical appearance of the rice bran.The color... Rice has been a staple food across the globe since time immemorial.Generally,different types of rice,such as white,purple,red,brown,and black rice,are named following the physical appearance of the rice bran.The color of the rice bran differs due to the presence of pigments in the rice varieties.Apart from general uses like cooking and fodder for cattle,rice has also been extensively involved in the field of medicine,some of which have been scientifically addressed.Although pigmented rice varieties have a history of heritage and are admired all over the world,awareness concerning the benefits of consuming these types of rice is limited.The main theme of this research article is to define the scientifically proven medicinal properties of black rice.The health properties of black rice are experimentally renowned,and gathered empirical data regarding the physiological and pharmacological activity of black rice remarkably supports the use of black rice in nutritional therapy. 展开更多
关键词 Black rice Cyanidin-3-O-glucoside DIABETES Dragon eyeball 100 Insulin resistance Oryza sativa
下载PDF
双栈网络下返回最优解析结果的DNS机制 被引量:1
6
作者 董晓军 《中国新通信》 2020年第21期49-50,共2页
在IPv4&IPv6双协议网络下返回最优解析结果的DNS(Domain Name System,域名系统)解析服务具有对重点域名的智能解析、择优返回解析结果、提升客户端访问重点域名所在服务器访问速度、减少网络资源浪费等优势,在当前客户端广泛应用了H... 在IPv4&IPv6双协议网络下返回最优解析结果的DNS(Domain Name System,域名系统)解析服务具有对重点域名的智能解析、择优返回解析结果、提升客户端访问重点域名所在服务器访问速度、减少网络资源浪费等优势,在当前客户端广泛应用了Happy Eyeballs算法,且IPv6网络的建设尚不健全的背景下,具有广泛的应用前景。返回最优解析结果机制依附于DNS服务的缓存,在非DNS解析层面进一步提升了客户端访问服务器的速度,从整个互联网架构角度,提升用户的上网体验。 展开更多
关键词 双栈网络 DNS 服务质量最优结果 Happy eyeballs算法
下载PDF
Prognostic values of optic nerve sheath diameter for comatose patients with acute stroke:An observational study 被引量:1
7
作者 Sha Zhu Chao Cheng +3 位作者 Liu-Liu Wang Dian-Jiang Zhao Yuan-Li Zhao Xian-Zeng Liu 《World Journal of Clinical Cases》 SCIE 2022年第33期12175-12183,共9页
BACKGROUND Optic nerve sheath diameter(ONSD)measurement is one of the non-invasive methods recommended for increased intracranial pressure(ICP)monitoring.AIM This study aimed to evaluate the roles of optic nerve sheat... BACKGROUND Optic nerve sheath diameter(ONSD)measurement is one of the non-invasive methods recommended for increased intracranial pressure(ICP)monitoring.AIM This study aimed to evaluate the roles of optic nerve sheath diameter(ONSD)and ONSD/eyeball transverse diameter(ETD)ratio in predicting prognosis of death in comatose patients with acute stroke during their hospitalization.METHODS A total of 67 comatose patients with acute stroke were retrospectively recruited.The ONSD and ETD were measured by cranial computed tomography(CT)scan.All patients underwent cranial CT scan within 24 h after coma onset.Patients were divided into death group and survival group according to their survival status at discharge.The differences of the ONSD and ONSD/ETD ratio between the two groups and their prognostic values were compared.RESULTS The ONSD and ONSD/ETD ratio were 6.07±0.72 mm and 0.27±0.03 in the comatose patients,respectively.The ONSD was significantly greater in the death group than that in the survival group(6.32±0.67 mm vs 5.65±0.62 mm,t=4.078,P<0.0001).The ONSD/ETD ratio was significantly higher in the death group than that in the survival group(0.28±0.03 vs 0.25±0.02,t=4.625,P<0.0001).The area under the receiver operating characteristic curve was 0.760(95%CI:0.637-0.882,P<0.0001)for the ONSD and 0.808(95%CI:0.696-0.920,P<0.0001)for the ONSD/ETD ratio.CONCLUSION The mortality increased in comatose patients with acute stroke when the ONSD was>5.7 mm or the ONSD/ETD ratio was>0.25.Both indexes could be used as prognostic tools for comatose patients with acute stroke.The ONSD/ETD ratio was more stable than the ONSD alone,which would be preferred in clinical practice. 展开更多
关键词 Optic nerve sheath diameter eyeball transverse diameter COMA Intracranial pressure STROKE PROGNOSIS
下载PDF
Mechanics of bioinspired imaging systems 被引量:1
8
作者 Zhengwei Li Yu Wang Jianliang Xiao 《Theoretical & Applied Mechanics Letters》 CAS CSCD 2016年第1期11-20,共10页
Imaging systems in nature have attracted a lot of research interest due to their superior optical and imaging characteristics, Recent advancements in materials science, mechanics, and stretchable electronics have led ... Imaging systems in nature have attracted a lot of research interest due to their superior optical and imaging characteristics, Recent advancements in materials science, mechanics, and stretchable electronics have led to successful development of bioinspired cameras that resemble the structures and functions of biological light-sensing organs. In this review, we discuss some recent progresses in mechanics of bioinspired imaging systems, including tunable hemispherical eyeball camera and artificial compound eye camera. The mechanics models and results reviewed in this article can provide efficient tools for design and optimization of such systems, as well as other related optoelectronic systems that combine rigid elements with soft substrates. 展开更多
关键词 Mechanics Bioinspired imaging system eyeball camera Compound eye camera Stretchable electronics
下载PDF
Intra-Arterial Chemotherapy for Retinoblastoma
9
作者 Hanan M. Makhdoum Shatha A. Albadawi Haneen H. Almuhammadi 《Open Journal of Ophthalmology》 2022年第1期91-106,共16页
The management of retinoblastoma is challenging and complex. Preservation of the eyeball as well as vision, with minimum morbidity, is the aim in the initial stages. This has been made possible by the use of chemother... The management of retinoblastoma is challenging and complex. Preservation of the eyeball as well as vision, with minimum morbidity, is the aim in the initial stages. This has been made possible by the use of chemotherapy that is targeted to the eye in the form of selective intravitreal and intra-arterial chemotherapy which has shown promising results. The efficacy and safety of intra- arterial chemotherapy have been reported by many specialized centers. The aim of this article was to review the role of intraarterial chemotherapy in the management of retinoblastoma and its clinical outcomes. In addition, we will review the possible complications of the procedure. We were able to collect articles relevant to our research objectives by reviewing the title and abstract of each article. Irrelevant articles and those that did not meet the inclusion criteria were excluded. This yielded a total of 19 studies. The results indicated that intraarterial chemotherapy is an effective and new modality of treatment for retinoblastoma to salvage the eyeball and helps in the prevention of enucleation with minimal local and systemic complications that are mostly transient. For future work, we recommend conducting more prospective studies with large samples and the long duration of follow-up. Also, we recommend future studies focusing on assessing visual acuity, as most of the currently available studies did not assess the visual acuity, making the judgment on vision preservation with IAC difficult. 展开更多
关键词 RETINOBLASTOMA Intra-Arterial Chemotherapy Intravitreal Chemotherapy eyeball Salvage
下载PDF
Effects of Intraorbital Electroacupuncture on Diabetic Abducens Nerve Palsy 被引量:8
10
作者 Ling-Yun Zhou Tie-Juan Liu +2 位作者 Xue-Mei Li Chang Su Jin Zhou 《Chinese Medical Journal》 SCIE CAS CSCD 2017年第14期1741-1742,共2页
Diabetic abducens nerve palsy main symptoms include ocular motility disorders and diplopia.This disease is mainly caused by severe vascular degeneration.It is a serious impact on patient's quality of life and mental ... Diabetic abducens nerve palsy main symptoms include ocular motility disorders and diplopia.This disease is mainly caused by severe vascular degeneration.It is a serious impact on patient's quality of life and mental health.Currently,there is no effective means of intervention for eye movement disorders and diplopia,the patients could only expect for neural self-repair.[1] Our team invented intraorbital electroacupuncture (IEA) therapy to repair abducens nerve affected by diabetes.In the meantime,we applied it into clinical practice and achieved great success. 展开更多
关键词 ACUPUNCTURE Diabetic Abducens Nerve Palsy Diplopia Deviation eyeball Movement
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部