期刊文献+
共找到118篇文章
< 1 2 6 >
每页显示 20 50 100
Differential diagnosis of pancreatic cancer by single-shot echo-planar imaging diffusion-weighted imaging 被引量:5
1
作者 Ben-Zu Hong Xin-Feng Li Jian-Qing Lin 《World Journal of Gastroenterology》 SCIE CAS 2015年第20期6374-6380,共7页
AIM: To investigate the diagnostic ability of single-shot echo-planar imaging(EPI) diffusion-weighted imaging (DWI) to differentiate between malignant and benign pancreatic lesions. METHODS: A computerized search was ... AIM: To investigate the diagnostic ability of single-shot echo-planar imaging(EPI) diffusion-weighted imaging (DWI) to differentiate between malignant and benign pancreatic lesions. METHODS: A computerized search was performed on Pub Med, MEDLINE and EMBASE up to August 2014. Nine studies(10 sets of data) with a total of 304 malignant pancreatic lesions and 188 benign pancreatic lesions were included. The characteristics of each study included the study name, year of publication, magnetic resonance modalities used, patient population, strength of field, pulse time, repetition time, echo time(TE), maximum b factor, mean age, mean body weight, fat suppression, number of benign and malignant lesions, and true positive, true negative, false positive and false negative results. All analyses were performed using Meta-Di Sc and Stata 11.0.RESULTS: The pooled sensitivity and specificity of singleshot EPI DWI were 0.83(95%CI: 0.79-0.87) and 0.77(95%CI: 0.70-0.83), respectively. The positive likelihood ratio and negative likelihood ratio were 5.09(95%CI: 2.19-11.84) and 0.23(95%CI: 0.15-0.36), respectively. The P value for the χ2 heterogeneity for all pooled estimates was < 0.05. From the fitted summary receiver operating characteristic curve, the area under the curve and Q* index were 0.89 and 0.82, respectively. Publication bias was not present(t = 0.58, P = 0.58). Meta-regression analysis indicated that fat suppression, mean age, TE, and maximum b factor were not sources of heterogeneity(all P > 0.05). CONCLUSION: Single-shot EPI DWI is useful to differentiate between malignant and benign pancreatic lesions. Lesion size ≥ 2 cm is the limit for the diagnosis of early lesions. 展开更多
关键词 Meta-analysis Single-shot echo-planarimaging DIFFUSION-WEIGHTED imaging PANCREATIC cancer Differential diagnosis
下载PDF
MAGiC技术诊断新生儿高胆红素血症
2
作者 刘畅 闫瑞芳 +4 位作者 谢北辰 任继鹏 段金辉 崔静威 翟晓阳 《中国医学影像技术》 CSCD 北大核心 2024年第4期508-513,共6页
目的 观察MAGiC技术诊断新生儿高胆红素血症(NHB)的价值。方法 前瞻性纳入33例NHB新生儿作为NHB组,以30名正常新生儿为对照组;行MAGiC序列颅脑MR扫描,记录苍白球、壳核及丘脑ROI定量值,包括T1、T2弛豫值及质子密度(PD)值,并计算苍白球/... 目的 观察MAGiC技术诊断新生儿高胆红素血症(NHB)的价值。方法 前瞻性纳入33例NHB新生儿作为NHB组,以30名正常新生儿为对照组;行MAGiC序列颅脑MR扫描,记录苍白球、壳核及丘脑ROI定量值,包括T1、T2弛豫值及质子密度(PD)值,并计算苍白球/壳核定量比值。比较组间各脑区定量值及定量比值,绘制受试者工作特征曲线,计算曲线下面积(AUC)以评估诊断效能,并以Pearson相关性分析评估血清总胆红素(TSB)水平与各脑区定量值及定量比值的相关性。结果 组间各脑区T1、T2及PD值差异均无统计学意义(P均>0.05);NHB组苍白球/壳核T1值比值、T2值比值均小于对照组(P均<0.05)。苍白球/壳核T1值比值诊断NHB的AUC为0.79(P<0.05);而苍白球/壳核T2值比值诊断NHB的效能低(AUC=0.63,P>0.05)。TSB与苍白球T2值(r=-0.299,P<0.05)、苍白球/壳核T1值比值(r=-0.480,P<0.05)及苍白球/壳核T2值比值(r=-0.328,P<0.05)均呈负相关。结论 以MAGiC技术获取苍白球/壳核T1值比值对于诊断NHB具有一定价值。 展开更多
关键词 高胆红素血症 新生儿 回波平面成像
下载PDF
基于压缩感知EPI的ASL技术在健康志愿者脑灌注成像中的应用研究
3
作者 卞红丽 王建伟 +1 位作者 王敏 刘俊 《中国医疗设备》 2024年第5期133-136,154,共5页
目的探讨基于联合压缩感知(Compressed Sensing,CS)平面回波成像(Echo Planer Imaging,EPI)的动脉自旋标记(Arterial Spin Labeling,ASL)技术,即EPICS-ASL序列在脑灌注成像中的应用价值,并与传统EPI-ASL序列进行比较。方法前瞻性收集30... 目的探讨基于联合压缩感知(Compressed Sensing,CS)平面回波成像(Echo Planer Imaging,EPI)的动脉自旋标记(Arterial Spin Labeling,ASL)技术,即EPICS-ASL序列在脑灌注成像中的应用价值,并与传统EPI-ASL序列进行比较。方法前瞻性收集30例志愿者行EPICS-ASL和传统EPI-ASL序列扫描。在ASL原始图上选取基底节、灰质、白质、脑干和小脑作为感兴趣区(Region of Interest,ROI),测量并计算各ROI的信噪比(Signal to Noise Ratio,SNR)和灰质/白质对比噪声比(Contrast to Noise Ratio,CNR灰质/白质);2名医师独立双盲采用4分法主观评估两组图像质量。采用配对t检验比较两组图像的SNR和CNR灰质/白质,采用秩和检验比较两组图像主观评分结果。结果客观评价,EPICS-ASL组各ROI的SNR和CNR灰质/白质均优于EPI-ASL组各ROI的SNR和CNR灰质/白质(均P<0.001);主观评价,EPICS-ASL组的图像质量评分也优于EPI-ASL组(均P<0.001)。结论EPICS-ASL序列显著优于传统EPI-ASL序列的图像SNR和CNR,图像质量更高,具有进一步临床应用的潜力。 展开更多
关键词 动脉自旋标记 压缩感知 平面回波序列 敏感度编码技术
下载PDF
MRI三维容积式插入法屏气检查对胰腺癌的诊断价值及对可切除性的评估价值
4
作者 杨达 刘亚南 +3 位作者 李倩 陈彦君 任月勤 张萍 《癌症进展》 2024年第1期84-87,共4页
目的探讨MRI三维容积式插入法屏气检查(3D-VIBE)对胰腺癌的诊断价值及对可切除性的评估价值。方法选取120例胰腺癌患者,均进行自旋回波-回波平面成像(SE-EPI)与3D-VIBE序列MRI检查。以手术后的病理检查结果作为金标准,分析SE-EPI与3D-V... 目的探讨MRI三维容积式插入法屏气检查(3D-VIBE)对胰腺癌的诊断价值及对可切除性的评估价值。方法选取120例胰腺癌患者,均进行自旋回波-回波平面成像(SE-EPI)与3D-VIBE序列MRI检查。以手术后的病理检查结果作为金标准,分析SE-EPI与3D-VIBE序列诊断胰腺癌T分期与术后病理T分期的一致性。采用受试者工作特征曲线(ROC)分析SE-EPI与3D-VIBE序列对胰腺癌的诊断价值。比较胰腺癌患者SE-EPI和3D-VIBE序列扫描的强化特征。以手术实际切除为标准,分析SE-EPI与3D-VIBE序列对胰腺癌可切除性的评估价值。结果SE-EPI与3D-VIBE序列诊断胰腺癌T分期与术后病理T分期的一致性均较好(Kappa=0.875、0.850,P﹤0.01)。ROC曲线显示,3D-VIBE序列诊断胰腺癌的灵敏度和曲线下面积(AUC)均高于SE-EPI序列。3D-VIBE序列的动脉早期信噪比(SNR)、动脉晚期SNR、动脉早期对比度噪声(CNR)、动脉晚期CNR均明显高于SE-EPI序列,差异均有统计学意义(P﹤0.01)。SE-EPI与3D-VIBE序列评估胰腺癌可切除性与手术实际切除的一致性均较好(Kappa=0.967、0.992,P﹤0.01)。结论MRI 3D-VIBE序列对胰腺癌及其T分期具有较高的诊断价值,且对其可切除性具有较高的评估价值。 展开更多
关键词 自旋回波-回波平面成像 三维容积式插入法屏气检查 胰腺癌 可切除性
下载PDF
同时多层采集技术结合分段读出平面回波成像序列弥散加权成像评估直肠腺癌病理分化程度 被引量:2
5
作者 罗明芳 周蜜 +2 位作者 李方 何岳丰 黄红云 《中国介入影像与治疗学》 北大核心 2023年第8期483-487,共5页
目的观察不同层加速因子同时多层(SMS)采集技术结合分段读出平面回波成像序列(rs-EPI)弥散加权成像(DWI)评估直肠腺癌病理分化程度的可行性。方法回顾性分析59例经术后病理证实的直肠腺癌患者,均接受直肠常规rs-EPI序列(DWI_(1))、层加... 目的观察不同层加速因子同时多层(SMS)采集技术结合分段读出平面回波成像序列(rs-EPI)弥散加权成像(DWI)评估直肠腺癌病理分化程度的可行性。方法回顾性分析59例经术后病理证实的直肠腺癌患者,均接受直肠常规rs-EPI序列(DWI_(1))、层加速因子为2的SMS技术结合rs-EPI序列(DWI2)及层加速因子为3的SMS技术结合rs-EPI序列(DWI_(3))DWI检查,采集时间分别为137、60、51 s,获得相应表观弥散系数(ADC)。根据术后组织病理学所见将病灶分为高、中、低分化,比较不同分化程度直肠腺癌之间ADC,以及相同分化程度内ADC的差异,分析ADC与直肠腺癌分化程度的相关性。结果高、中分化与低分化直肠腺癌间ADC_(1)、ADC_(2)、ADC_(3)差异均有统计学意义(P均<0.05);高、中分化直肠腺癌间ADC差异均无统计学意义(P均>0.05)。高分化直肠腺癌ADC_(1)、ADC_(2)及ADC_(3)总体差异无统计学意义(P=0.08);中、低分化直肠腺癌ADC_(3)值均低于ADC_(1)及ADC_(2)(P均<0.01),ADC_(1)与ADC_(2)差异均无统计学意义(P均>0.05)。直肠腺癌病理分化程度与ADC_(1)(r_(s)=0.49,P<0.01)、ADC_(2)(r_(s)=0.51,P<0.01)及ADC_(3)(r_(s)=0.40,P<0.05)均呈正相关。结论以层加速因子为2的SMS技术结合rs-EPI采集的DWI可用于评估直肠腺癌病理分化程度。 展开更多
关键词 直肠肿瘤 磁共振成像 弥散 分段读出平面回波成像 同时多层采集技术 病理分化
下载PDF
女性盆腔全视野和小视野弥散加权成像图像质量研究
6
作者 吴超 吕富荣 +2 位作者 肖智博 陆云峰 万承鑫 《中国医学计算机成像杂志》 CSCD 北大核心 2023年第5期541-545,共5页
目的:对比分析全视野(fFOV)和小视野(rFOV)弥散加权成像(DWI)序列在女性盆腔检查中的图像质量。方法:纳入2020年4月—8月在重庆医科大学附属第一医院行盆腔MRI检查的无盆腔疾病女性46例,扫描序列包括T2WI、fFOV-DWI和rFOV-DWI,采用Liker... 目的:对比分析全视野(fFOV)和小视野(rFOV)弥散加权成像(DWI)序列在女性盆腔检查中的图像质量。方法:纳入2020年4月—8月在重庆医科大学附属第一医院行盆腔MRI检查的无盆腔疾病女性46例,扫描序列包括T2WI、fFOV-DWI和rFOV-DWI,采用Likert-type量表5级评分法对DWI图像进行主观质量评价,采用信噪比(SNR)和对比度噪声比(CNR)对DWI图像进行客观质量评价。结果:rFOV-DWI序列的SNR (P=0.001)、CNR (P=0.008)、伪影评分(P=0.000)解剖结构识别评分(P=0.000)均高于fFOV-DWI序列。结论:与fFOV-DWI序列相比,rFOV-DWI序列可减少女性盆腔图像伪影,且SNR和CNR显著提高,利于图像识别,为盆腔疾病的诊断提供新方法,可作为fFOV-DWI序列替代选择。 展开更多
关键词 妇科检查 弥散加权成像 回波平面成像 信噪比
下载PDF
SE-EPI与IR-EPI序列在3.0 T胎儿颅脑磁共振扩散加权成像中的对比研究
7
作者 李鸿恩 谢汉民 +3 位作者 吕培锋 袁灿桃 刘春花 曾益辉 《影像诊断与介入放射学》 2023年第5期353-358,共6页
目的研究自旋回波-平面回波成像(SE-EPI)与短时反转恢复-平面回波成像(IR-EPI)序列在3.0 T胎儿颅脑磁共振扩散加权成像(DWI)中图像质量及表观扩散系数(ADC)值差异。方法前瞻性分析47例因产前超声可疑胎儿颅脑异常行3.0 T磁共振检查资料... 目的研究自旋回波-平面回波成像(SE-EPI)与短时反转恢复-平面回波成像(IR-EPI)序列在3.0 T胎儿颅脑磁共振扩散加权成像(DWI)中图像质量及表观扩散系数(ADC)值差异。方法前瞻性分析47例因产前超声可疑胎儿颅脑异常行3.0 T磁共振检查资料。分别采集SE-EPI-DWI和IR-EPI-DWI序列图像,对两组图像质量进行主观及客观评估。主观评估由两名具有5年以上经验丰富副主任医师根据Likert 7分评分系统对图像磁敏感伪影、图像整体质量进行评分并分析,采用Wilcoxon符号秩和检验进行图像质量评分差异性分析,采用Spearman等级相关检验进行两名医师之间相关性分析。客观评估分别测量计算两组DWI图像的信噪比(SNR)、对比噪声比(CNR)、正常ADC值及特异吸收率(SAR)值差异,并进行统计学分析。结果47例胎儿成像主观评价一致性分析提示:阅者1和阅者2评分结果显示SE-EPI序列图像优于IR-EPI序列图像,SE-EPI有效降低图像伪影、提高图像整体质量(P均=0.000);两名阅者之间相关性评分图像伪影、图像整体质量呈高度正相关(r=0.939、0.925,P=0.000、0.000)。客观评价:IR-EPI-DWI序列组额叶白质区及侧脑室后角区SNR高于SE-EPI-DWI序列组(F=0.037、1.386,P=0.847、0.242),差异无统计学意义;SE-EPI-DWI序列组CNR高于IR-EPI-DWI序列组(F=0.550,P=0.460),差异无统计学意义;额叶白质区ADC值两组序列差异无统计学意义(F=2.386,P=0.126),侧脑室后角区ADC值两组序列差异无统计学意义(F=0.615,P=0.435);SAR值两组序列对比,差异具有显著统计学意义(P=0.000)。结论3.0 T胎儿颅脑磁共振SE-EPI-DWI序列采集速度快、图像伪影小、检查成功率高,可作为常规胎儿头颅磁共振检查首选序列,IR-EPI-DWI的SNR稍高于SE-EPI-DWI序列图像,可作为SE-EPI-DWI序列外的补充序列。 展开更多
关键词 磁共振成像 扩散加权成像 平面回波成像 胎儿 图像质量
下载PDF
任意路径航行的水下航行器回波特征研究
8
作者 韩林江 陆金铭 +1 位作者 刘进伟 彭子龙 《舰船科学技术》 北大核心 2023年第9期51-55,共5页
本文阐述基于频域间接法的板块元基本原理,建立水下航行器三维网格模型,提出以任意路径运动的水下航行器回波特征预报方法。通过开展1:20缩比的Benchmark潜艇回波特性水下声散射试验,验证了上述预报方法的准确性。研究表明,预报方法能... 本文阐述基于频域间接法的板块元基本原理,建立水下航行器三维网格模型,提出以任意路径运动的水下航行器回波特征预报方法。通过开展1:20缩比的Benchmark潜艇回波特性水下声散射试验,验证了上述预报方法的准确性。研究表明,预报方法能够预测水下航行器以任意路径航行的回波特征,对水下运动目标的探测与识别有一定意义。 展开更多
关键词 水下航行器 回波特征 板块元 任意路径
下载PDF
Diffusion weighted imaging for the detection and evaluation of cholesteatoma 被引量:8
9
作者 Benjamin Henninger Christian Kremser 《World Journal of Radiology》 CAS 2017年第5期217-222,共6页
Cholesteatoma is a collection of keratinous debris and stratified squamous epithelium.It is trapped in the middle ear and can lead to bony erosion.The disease is treated surgically often followed by a second-look proc... Cholesteatoma is a collection of keratinous debris and stratified squamous epithelium.It is trapped in the middle ear and can lead to bony erosion.The disease is treated surgically often followed by a second-look procedure to check for residual tissue or recurrence.Cholesteatoma has specific signal-intensity characteristics on magnetic resonance imaging with very high signal intensity on diffusion weighted imaging(DWI).Various DWI techniques exist:Echo-planar imaging(EPI)-based and non-EPI-based techniques as well as new approaches like multi-shot EPI DWI.This article summarizes all techniques,discusses the significance in detecting cholesteatoma and mentions actual studies.Further recommendations for daily clinical practise are provided. 展开更多
关键词 CHOLESTEATOMA Diffusion weighted imaging Computed tomography Magnetic resonance imaging echo-planar imaging Non-echo-planar imaging
下载PDF
乳腺肿瘤表观弥散系数与组织细胞密度相关性研究 被引量:68
10
作者 郭勇 王辅林 +2 位作者 蔡幼铨 蔡祖龙 高元桂 《中国医学影像学杂志》 CSCD 2002年第4期241-243,共3页
目的 :评估组织细胞密度在良恶性乳腺病变弥散系数 (ApparentDiffusionCoefficients ,ADC)不同中所起的作用。材料和方法 :对经手术病理证实的 46例乳腺病变 (恶性肿瘤 2 6例 ,良性病变 2 0例 )进行磁共振弥散加权成像 (DiffusionWeight... 目的 :评估组织细胞密度在良恶性乳腺病变弥散系数 (ApparentDiffusionCoefficients ,ADC)不同中所起的作用。材料和方法 :对经手术病理证实的 46例乳腺病变 (恶性肿瘤 2 6例 ,良性病变 2 0例 )进行磁共振弥散加权成像 (DiffusionWeightedImaging ,DWI)检查 ,并计算病变的ADC值。用AdobePhotoshop 4.0software软件分析乳腺病变病理切片的细胞密度。统计分析ADC值与细胞密度的相关性。结果 :恶性肿瘤平均ADC值为 ( 0 .96 0 8± 0 .2 0 43)× 10 -3mm2 /s ,明显小于良性病变组 ( 1.5 934± 0 .2 0 84)× 10 -3mm2 /s ;P <0 .0 0 1)。恶性肿瘤平均细胞密度为 ( 14 .5 9± 4.35 ) % ,明显大于良性病变组 ( 10 .2 0± 4.32 % ;P <0 .0 5 )。乳腺病变ADC值与细胞密度的相关性很好 (r =-0 .5 42 )。结论 :在乳腺良恶性肿瘤ADC不同中 ,细胞密度起了重要作用。通过测量肿瘤ADC鉴别乳腺良恶性病变是一个有效的方法 ,但仍有其局限性。 展开更多
关键词 乳腺肿瘤 磁共振成像 回波平面成像 细胞密度 ADC 表观弥散系数
下载PDF
颈髓软化扩散张量成像的初步研究 被引量:18
11
作者 郑奎宏 马林 +2 位作者 郭勇 郭行高 梁丽 《中国医学影像技术》 CSCD 北大核心 2005年第7期1003-1005,共3页
目的探讨颈髓软化扩散张量成像的可行性及临床应用价值。方法采用平面回波成像技术对12例颈髓软化患者和36例健康志愿者行扩散张量成像(DTI)检查,并测量其表观扩散系数(ADC)值、各向异性分数(FA)值、第1本征值(λ1)、第2本征值(λ2)以及... 目的探讨颈髓软化扩散张量成像的可行性及临床应用价值。方法采用平面回波成像技术对12例颈髓软化患者和36例健康志愿者行扩散张量成像(DTI)检查,并测量其表观扩散系数(ADC)值、各向异性分数(FA)值、第1本征值(λ1)、第2本征值(λ2)以及第3本征值(λ3)。结果ADC图与FA图均能显示颈髓软化区之异常信号,其ADC值为(1512.44±450.16)×10-6mm2/s,FA值为(407.81±86.14)×10-3,λ1值为(2229.31±417.19)×10-6mm2/s,λ2值为(1416.01±379.05)×10-6mm2/s,λ3值为(1401.48±589.18)×10-6mm2/s,2λ1/(λ2+λ3)值为1.67±0.23。颈髓软化患者病变区的ADC、λ1、λ2、λ3值明显高于正常组(P<0.05),其FA值与2λ1/(λ2+λ3)值明显低于正常组(P<0.05),λ1与λ2、λ3值之间有显著性差异(P<0.05),λ1大于λ2与λ3。结论DTI是一种显示颈髓软化的可靠检查手段,软化灶的各向同性扩散明显增高,其各向异性扩散明显减低。 展开更多
关键词 脊髓疾病 磁共振成像 扩散 平面回波成像
下载PDF
表观扩散系数在乳腺病变诊断中的应用价值 被引量:22
12
作者 张静 程流泉 +2 位作者 安宁豫 蔡幼铨 郭勇 《中国医学影像学杂志》 CSCD 北大核心 2010年第6期485-491,共7页
目的:对比乳腺良、恶性病变的表观扩散系数(apparent diffusion coefficient,ADC),探讨DWI在乳腺病变中的诊断价值。材料和方法:搜集术前行MR检查并经病理证实的236例乳腺病变,采用平面回波-扩散加权成像序列(EPI-DWI);测量病变区和对... 目的:对比乳腺良、恶性病变的表观扩散系数(apparent diffusion coefficient,ADC),探讨DWI在乳腺病变中的诊断价值。材料和方法:搜集术前行MR检查并经病理证实的236例乳腺病变,采用平面回波-扩散加权成像序列(EPI-DWI);测量病变区和对侧正常乳腺腺体的ADC值,应用t检验比较良、恶性病变及正常腺体ADC值的差异,采用接收者工作特征曲线(receiver operating characteristic curve,ROC)确定良、恶性病变的ADC界值;根据BI-RADSMRI将乳腺病变分为肿块性病变和非肿块性病变,比较ADC值在两组病变中定性诊断效能。结果:236例乳腺病变中,恶性病变ADC值[(1.08±0.32)×10-3mm2/s]显著低于良性病变[(1.48±0.35)×10-3mm2/s],差异有统计学意义(P=0.01);根据ROC曲线确定ADC界值为1.25×10-3mm2/s,诊断敏感性和特异性分别为78.2%和77.5%。肿块性病变良、恶性ADC界值为1.15×10-3mm2/s(敏感性和特异性分别为79.8%和81.8%),非肿块性病变良、恶性ADC界值为1.35×10-3mm2/s(敏感性和特异性分别为78%和72%)。结论:根据ADC界值可以鉴别乳腺良、恶性病变;对肿块性病变和非肿块性病变应采用不同的ADC界值;DWI对肿块性病变的诊断效能优于非肿块性病变。 展开更多
关键词 乳腺肿瘤 磁共振成像 弥散 回波平面成像
下载PDF
磁共振成像中抑制伪影技术的研究进展 被引量:8
13
作者 陈春晓 陶华 +1 位作者 王世杰 罗立民 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2007年第2期457-459,共3页
磁共振成像可对人体各部位多角度、多平面成像,具有高组织分辨力、空间分辨力、无硬性伪迹及无放射损伤等优点,在医学上得到了广泛的应用。然而,磁共振成像中所产生的伪影会严重影响MRI的质量及对病灶的精确定位。我们主要介绍了近年来... 磁共振成像可对人体各部位多角度、多平面成像,具有高组织分辨力、空间分辨力、无硬性伪迹及无放射损伤等优点,在医学上得到了广泛的应用。然而,磁共振成像中所产生的伪影会严重影响MRI的质量及对病灶的精确定位。我们主要介绍了近年来抑制自旋回波平面成像技术中所产生的伪影及自主性运动伪影的研究进展。大量研究表明,怎样快速有效地抑制各种原因产生的伪影,仍然是研究人员所面临的一个非常棘手的问题。因此,还需不断寻求新的方法及思路来解决这一难题。 展开更多
关键词 磁共振成像 伪影 回波平面成像
下载PDF
Rs-EPI与Ss-EPI在头及膝关节3T弥散成像中的对照研究 被引量:14
14
作者 郗艳 刘慧 +1 位作者 姚伟武 李梅 《中国医学计算机成像杂志》 CSCD 北大核心 2016年第1期49-54,共6页
目的:同常规Ss-EPI-DWI序列对照,探讨读出方向分段采样序列RESOLVE序列(即Rs-EPIDWI序列)在头颅和膝关节3T弥散成像中的优势与可行性。方法:收集15例健康志愿者的头颅和膝关节Ss-EPI、Rs-EPI序列图像,由两名5年以上工作经验的放射科医... 目的:同常规Ss-EPI-DWI序列对照,探讨读出方向分段采样序列RESOLVE序列(即Rs-EPIDWI序列)在头颅和膝关节3T弥散成像中的优势与可行性。方法:收集15例健康志愿者的头颅和膝关节Ss-EPI、Rs-EPI序列图像,由两名5年以上工作经验的放射科医生根据Likert 7分评分系统对图像磁敏感畸变伪影、运动伪影、模糊效应、图像整体质量进行评分并记录。图像质量评分差异性采用Wilcoxon符号秩和检验,两名阅片者之间相关性采用Spearman等级相关检验。结果:Rs-EPI序列图像的磁敏感畸变伪影、运动伪影、模糊效应和图像整体质量明显优于Ss-EPI弥散图像(P<0.01),除头颅畸变伪影相关性(r=0.50,P=0.06)无统计学意义外,两名阅片者的其他评分呈密切正相关(r=0.65-0.89,P<0.01)。结论:RESOLVE序列可提高DWI图像质量,降低畸变伪影、运动伪影及模糊效应。RESOLVE改善头颅畸变伪影在阅片医师间存在差异。 展开更多
关键词 分段采样 弥散加权成像 平面回波成像 伪影
下载PDF
嗅觉脑功能磁共振成像中提高磁敏感性脑区信噪比的参数优化研究 被引量:5
15
作者 伍建林 鄂亚军 +2 位作者 张清 魏海峰 苗延巍 《中国医学影像技术》 CSCD 北大核心 2007年第12期1764-1768,共5页
目的探讨人脑嗅觉fMRI实验中改变和优化层厚及回波时间(TE)参数对降低磁敏感性伪影和提高信噪比(SNR)的价值。方法10例健康志愿者,使用GESigna1.5TMR成像仪,标准正交头线圈。采用GRE-EPI序列分别对不同层厚(2、3、4、5、6mm)和固... 目的探讨人脑嗅觉fMRI实验中改变和优化层厚及回波时间(TE)参数对降低磁敏感性伪影和提高信噪比(SNR)的价值。方法10例健康志愿者,使用GESigna1.5TMR成像仪,标准正交头线圈。采用GRE-EPI序列分别对不同层厚(2、3、4、5、6mm)和固定层厚为6mm与2mm,同时改变不同回波时间(20、25、30、35、40、45、50、55、60ms)而进行脑功能成像扫描,以观察扫描参数的变化对图像信噪比(SNR)的影响。数据处理应用MATLAB5.3与AFNI软件。在额叶底部、右侧海马区及左枕叶划定感兴趣区(后者为对照),SNR值=兴趣区信号强度(SI)/颅外空间噪声标准差(SD)。结果①改变扫描层厚时,磁敏感性脑区额叶底部及海马区SNR值随层厚的增加呈明显下降趋势(r1=-0.994,P〈0.01,r2=-0.999,P〈0.01),而非磁敏感性脑区左枕叶区SNR值呈轻度上升趋势(无统计学意义)。②改变回波时间时,绝大多数被试磁敏感区(额叶底部与海马区)的SNR值在层厚为6mm时较层厚为2mm时明显下降;同时,当层厚为2mm时,SNR值随TE时间的延长呈轻度升高或无明显变化;当层厚为6mm时,SNR值随TE时间的延长而下降。结论在嗅觉fMRI实验中,可通过优化改变层厚与TE来降低磁敏感性伪影和提高SNR;层厚及TE对SNR的影响是相互影响、相互制约的,选择2mm层厚和TE30~40ms可获得理想的功能图像质量。 展开更多
关键词 嗅觉 磁共振成像 磁敏感性伪影 平面回波成像 成像参数
下载PDF
MR灌注成像在评价脑内胶质瘤残留或复发方面的价值 被引量:6
16
作者 郑斐群 余永强 +3 位作者 钱银锋 柏亚 张诚 潘发明 《临床放射学杂志》 CSCD 北大核心 2006年第6期493-496,共4页
目的用受试者操作特性(ROC)分析方法评价常规MR和灌注成像(PWI)对脑内胶质瘤术后早期残存与复发的诊断价值。资料与方法回顾性分析经手术与病理证实的脑内胶质瘤86例,其中术后残留或复发50例,均经二次手术证实;其余36例术后随诊18个月... 目的用受试者操作特性(ROC)分析方法评价常规MR和灌注成像(PWI)对脑内胶质瘤术后早期残存与复发的诊断价值。资料与方法回顾性分析经手术与病理证实的脑内胶质瘤86例,其中术后残留或复发50例,均经二次手术证实;其余36例术后随诊18个月以上无复发表现。所有患者均行常规MRI和PWI,获得相对脑血流容积彩图,并计算肿瘤相对血容积比值。采用Windows98版ROCKIT软件进行ROC分析,使用微软Excel2000软件绘制ROC曲线图。结果86例胶质瘤术后的影像资料经ROC分析显示,常规MR曲线的a值(截距)为0.12,b值(斜率)为0.95,Az为0.5343;结合PWI的方法a值为0.56,b值为1.23,Az为0.6370。两种方法ROC曲线的Az差异有统计学意义(P=0.0001,<0.01)。在胶质瘤术后残存或复发的诊断方面,结合PWI的MRI诊断方法明显优于常规MRI。结论在术后早期,对胶质瘤残存与复发的监测方面,常规MRI结合PWI能明显提高特异性和敏感性。 展开更多
关键词 神经胶质瘤 磁共振成像 灌注成像 平面回波成像 受试者操作特征曲线
下载PDF
3TMRI腰骶部脊神经根扩散张量成像在腰椎间盘突出症中的应用价值 被引量:6
17
作者 王庆征 李传亭 +2 位作者 惠毅毅 刘传梅 张红 《医学影像学杂志》 2012年第10期1742-1745,共4页
目的探索扩散张量成像(diffusion tensor imaging,DTI)和纤维示踪成像(fibre tracking,FT)显示腰骶脊神经根的可行性,并评估椎间盘突出症患者L4及L5脊神经根各向异性分数(fractional anisotropy,FA)和表观扩散系数(apparent diffusion c... 目的探索扩散张量成像(diffusion tensor imaging,DTI)和纤维示踪成像(fibre tracking,FT)显示腰骶脊神经根的可行性,并评估椎间盘突出症患者L4及L5脊神经根各向异性分数(fractional anisotropy,FA)和表观扩散系数(apparent diffusion coefficient,ADC)值的差别。方法 20例由于后外侧或椎间孔椎间盘突出引起单侧坐骨神经痛的患者和20例健康志愿者纳入研究。所有检查均在Philips Achieve 3.0TTX MRI上进行,纤维示踪成像参数:FA阈值=0.15;最小纤维束长度=10mm;最大角度=27°。应用横轴位T2解剖融合图像序列评估重建图像的相关性。对所有被检者的L4、L5和S1脊神经根行扩散张量和纤维示踪成像,并在FA图和ADC图上测量L4和L5脊神经根的平均FA值和ADC值。结果腰椎间盘突出症患者和健康志愿者腰骶部脊神经根纤维束成像在T2解剖融合图像上完全匹配。在纤维示踪图像上可以清晰地辨别腰骶部脊神经根受压位置。所有患者和健康志愿者的FA值和ADC值可以从FA图和ADC图上获得。受压侧脊神经根的FA值显著低于对侧神经根(P<0.01)和健康志愿者的(P<0.01);ADC值显著高于对侧神经根(P<0.01)和健康志愿者的(P<0.01)。结论 3T MRI腰骶部脊神经根扩散张量和纤维示踪成像是可行的。腰椎间盘突出症患者受压L4和L5脊神经根的FA值和ADC值有显著性的变化。 展开更多
关键词 磁共振成像 平面回波成像 扩散张量成像 椎间盘突出
下载PDF
磁共振肾灌注成像技术 被引量:5
18
作者 肖志军 李英 +2 位作者 黄勃源 池琛 刘怀军 《临床放射学杂志》 CSCD 北大核心 2002年第6期436-438,共3页
目的 探讨磁共振肾灌注成像 (PWI)技术的价值。资料与方法 在应用平面回波成像 (EPI)技术的基础上 ,采用PWI技术 ,对 12例单侧上尿路梗阻患者进行肾功能损害的测定。结果 肾灌注成像曲线呈反抛物线形 ,正常两侧的肾灌注曲线几乎是重... 目的 探讨磁共振肾灌注成像 (PWI)技术的价值。资料与方法 在应用平面回波成像 (EPI)技术的基础上 ,采用PWI技术 ,对 12例单侧上尿路梗阻患者进行肾功能损害的测定。结果 肾灌注成像曲线呈反抛物线形 ,正常两侧的肾灌注曲线几乎是重叠的 ,病肾与正常肾灌注曲线相比 ,波始时间、达波谷时间均延长 ,经t检验 ,有显著差异 (P <0 .0 0 1) ,并且病肾的波幅小于正常肾。结论 在应用EPI基础上 ,采用PWI技术 。 展开更多
关键词 平面回波成像技术 磁共振肾灌注成像 肾病 尿路梗阻
下载PDF
声呐目标回声特性预报的板块元方法 被引量:50
19
作者 范军 汤渭霖 卓琳凯 《船舶力学》 EI 北大核心 2012年第1期171-180,共10页
将计算雷达散射截面的板块元方法引入到声呐目标强度计算中。在应用Kirchhoff近似计算水中目标散射声场时,用一组平面板块元近似复杂形状目标曲面,所有板块元的散射声场的和就是总散射声场的近似值。通过将单个板块元的积分化为代数和... 将计算雷达散射截面的板块元方法引入到声呐目标强度计算中。在应用Kirchhoff近似计算水中目标散射声场时,用一组平面板块元近似复杂形状目标曲面,所有板块元的散射声场的和就是总散射声场的近似值。通过将单个板块元的积分化为代数和避免了面积分运算,使得板块元法比通常的面元积分法计算速度提高许多倍。针对声呐的情况将此方法推广到目标近场和非刚性表面回声特性预报。用这种方法解决了多种声呐目标的回声计算并开发了专用软件,能够快速计算各种形状声呐目标的目标强度。 展开更多
关键词 声呐 回声特性 板块元方法
下载PDF
四种序列1.5T磁共振成像口腔金属冠引起伪影程度的对比 被引量:4
20
作者 高岚 廉云敏 +2 位作者 崔彩霞 肖铁朋 陈磊 《中国全科医学》 CAS CSCD 北大核心 2014年第18期2164-2167,共4页
目的探讨在有金属冠存在的情况下,1.5 T磁共振成像T2*/梯度回波序列(GRE)、T2W/反转恢复自旋回波(IR)、T2W/快速自旋回波序列(FSE)、T1W/自旋回波序列(SE)4种序列产生伪影的程度。方法给实验犬依次佩戴钴铬合金、镍铬合金、低钛合金、... 目的探讨在有金属冠存在的情况下,1.5 T磁共振成像T2*/梯度回波序列(GRE)、T2W/反转恢复自旋回波(IR)、T2W/快速自旋回波序列(FSE)、T1W/自旋回波序列(SE)4种序列产生伪影的程度。方法给实验犬依次佩戴钴铬合金、镍铬合金、低钛合金、纯钛金属4种金属冠,按序进行4种序列常规1.5 T磁共振成像的颅脑扫描,分别测量4种序列在4种金属冠存在下所产生伪影的最大面积并计数金属伪影涉及图像的层数,对测量结果进行统计分析。结果各金属冠在1.5 T磁共振成像4种序列均产生了伪影。4种序列钴铬合金、镍铬合金、低钛合金、纯钛金属伪影最大面积比较,差异有统计学意义(P<0.05);其中T2W/IR组、T2W/FSE组、T1W/SE组较T2*/GRE组均降低(P<0.05)。结论金属冠引起T2*/GRE序列伪影最大,其他3种序列产生伪影程度相近。 展开更多
关键词 磁共振成像 回波平面成像 牙冠(假体)
下载PDF
上一页 1 2 6 下一页 到第
使用帮助 返回顶部