Evaluation of Atrial Septal Defect Using Real-time Three-dimensional Echocardiography:Comparison with Surgical Findings 被引量:2
1
作者 Saumu Tobbi Mweri 邓又斌 +12 位作者 程佩萱 林汉华 王宏伟 Ommari Baaliy Mkangara 夏治 胡秀芬 毕小军 伍玉晗 Mustaafa Bapumiia 申屠伟慧 刘蓉 刘娅妮 朱美华 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第2期257-259,共3页
The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical find... The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was performed in 26 patients with atrial septal defect, and the echocardiographic data were compared with the surgical findings. Significant correlation was found between defect diameter by RT3DE and that measured during surgery (r=0.77, P〈0.001). The defect area changed significantly during cardiac cycle. Percentage change in defect size during cardiac cycle ranged from 6%-70%. Our study showed that the size and morphology of atrial septal defect obtained with RT3DE correlate well with surgical findings. Therefore, RT3DE is a feasible and accurate non-invasive imaging tool for assessment of atrial septal size and dynamic changes. 展开更多
关键词 real-time three-dimensional echocardiography atrial septal defect two dimensional echocardiography
下载PDF
Assessment of Left Atrial Function by Full Volume Real-time Three-dimensional Echocardiography and Left Atrial Tracking in Essential Hypertension Patients with Different Patterns of Left Ventricular Geometric Models 被引量:9
2
作者 Yang Wang Lin Gao +1 位作者 Jian-bai Li Chao Yu 《Chinese Medical Sciences Journal》 CAS CSCD 2013年第3期152-158,共7页
Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography (RT-3DE) and left atrial tra... Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography (RT-3DE) and left atrial tracking (EAT). 展开更多
关键词 essential hypertension left atrial function three-dimensional echocardiography left atrial tracking
下载PDF
Evaluation of Right Ventricular Volume and Systolic Function by Real-time Three-dimensional Echocardiography 被引量:4
3
作者 王静 王新房 +4 位作者 谢明星 杨娅 吕清 杨颖 王良玉 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2005年第1期94-96,99,共4页
The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function... The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function was assessed. RV “Full volume” images were acquired by RT3DE in 22 healthy subjects. RV end-diastolic volumes (RVEDV) and end-systolic volumes (RVESV) were outlined using apical biplane, 4-plane, 8-plane, 16-plane offline separately. RVSV and RVEF were calculated. Meanwhile tricuspid annual systolic excursion (TASE) was measured by M-mode echo. LVSV was outlined by 2-D echo according to the biplane Simpson's rule. The results showed: (1) There was a good correlation between RVSV measured from series planes and LVSV from 2-D echo (r=0.73; r=0.69; r=0.63; r=0.66, P<0.25—0.0025); (2) There were significant differences between RVEDV in biplane and those in 4-, 8-, 16-plane (P<0.001). There was also difference between RV volume in 4-plane and that in 8-plane (P<0.05), but there was no significant difference between RV volume in 8-plane and that in 16-plane (P>0.05); (3) Inter-observers and intro-observers variability analysis showed that there were close agreements and relations for RV volumes (r=0.986, P<0.001; r=0.93, P<0.001); (4) There was a significantly positive correlation of TASE to RVSV and RVEF from RT3DE (r=0.83; r=0.90). So RV volume measures with RT3DE are rapid, accurate and reproducible. In view of RV's complex shape, apical 8-plane method is better in clinical use. It may allow early detection of RV systolic function. 展开更多
关键词 real-time three-dimensional echocardiography right ventricular volume apical 8-plane right ventricular systolic function
下载PDF
Evaluation of Biventricular Volume and Systolic Function in Children with Ventricular Septal Defect and Moderate to Severe Pulmonary Hypertension Using Real-Time Three-Dimensional Echocardiography
4
作者 Huan Zhou Jin Kang +5 位作者 Jun Gao Xiaoyuan Feng Li Zhou Xia Xiao Zhengliang Meng Chengwen Guo 《Congenital Heart Disease》 SCIE 2022年第6期697-707,共11页
Background: Real-time three-dimensional echocardiography (RT-3DE) could obtain ventricular volume andejection fraction rapidly and non-invasively without relying on ventricular morphology. This study aims to useRT-3DE... Background: Real-time three-dimensional echocardiography (RT-3DE) could obtain ventricular volume andejection fraction rapidly and non-invasively without relying on ventricular morphology. This study aims to useRT-3DE to evaluate the changes in biventricular volume and systolic function in children with ventricular septaldefect (VSD) and moderate to severe pulmonary hypertension (PH) before surgery. Methods: In this study18 children with VSD and moderate to severe PH (VSD + PH Group) and 18 healthy children of the sameage (Control Group) were recruited. Biventricular volume and systolic function were evaluated by RT-3DE.The measurements included: left and right ventricular volume indexed to body surface area (BSA), stroke volume(SV) indexed to BSA, and ejection fraction (EF). Results: The results showed left and right ventricular volumeindexed to BSA and SV indexed to BSA were significantly increased in VSD + PH Group (VSD + PH Groupvs. Control Group), LVEDV/BSA (ml/m2): 48.67 ± 21.46 vs. 25.59 ± 6.96, RVEDV/BSA (ml/m2): 55.98 ±15.35 vs. 27.69 ± 4.37, LVSV/BSA (ml/m2): 24.08 ± 9.30 vs. 15.14 ± 4.29, RVSV/BSA (ml/m2): 26.02 ± 8.87 vs.14.11 ± 2.89, (P < 0.05). While for EF in VSD + PH Group decreased (VSD + PH Group vs. Control Group),LVEF: 50.93 ± 7.50% vs. 59.38 ± 7.24%, RVEF: 45.84 ± 7.71% vs. 51.05 ± 6.90% (P < 0.05). Conclusion: Inchildren with VSD and moderate to severe PH, increased biventricular volume and decreased systolic functionwere observed with RT-3DE, but biventricular systolic function remained within acceptable limits. The childrenin this study recovered well after surgery without serious perioperative complications, suggesting that biventricularsystolic function may help facilitate the surgical decision-making process in children with VSD and moderate-toseverePH. 展开更多
关键词 real-time three-dimensional echocardiography ventricular septal defect pulmonary hypertension CHILDREN
下载PDF
REAL-TIME THREE-DIMENSIONAL ECHOCARDIOGRAPHY FOR QUANTIFYING LEFT VENTRICULAR MASS 被引量:4
5
作者 Hong-wenFei Xin-fangWang +5 位作者 Ming-xingXie LeiZhuang Li-xinChen Run-qingHuang YingYang JingWang 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第3期230-232,共3页
To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phanto... To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phantoms made of two rubber-bursas, ten excised canine hearts underwent RT3DE and two-dimensional echocardiography (2DE). In RT3DE "full volume" imaging, the myocardial volume was mea-sured using 2,4,8, and 16-plane method with the analysis software of RT3DE. Mass was then calculated by multiplying the resulting myocardial volume by specific density of myocardial tissue. In 2DE the masses were measured by area-length meth-od. The true LV wall phantom mass was measured by water displacement and the canine LVM was weighed by anatomy, which served as a reference standard. We compared RT3DE or 2DE with true mass. Results In LV wall phantoms, RT3DE correlated with true masses strongly (r = 0.813-0.994) and weakly correlated between 2DE and true masses (r = 0.628). In excised canine hearts, there is an excellent correlation between RT3DE and true masses (r = 0.764-0.991), while 2DE value showed a lesser correlation (r = 0.514). There are no difference between RT-3DE and true masses (P > 0.05) but different between 2DE and true masses (P < 0.05). In different planes, there was no difference between 8-plane and 16-plane (P > 0.05) but different between 8-plane and 2, 4-plane (P < 0.05). Conclusion RT3DE can accurately quantify LVM and provide a new tool to evaluate LV function. For LVM by RT3DE, 8-plane measurement method is the best choice for accuracy and convenience. 展开更多
关键词 real-time three-dimensional echocardiography left ventricular mass
下载PDF
Real-time three-dimensional echocardiography predicts cardiotoxicity induced by postoperative chemotherapy in breast cancer patients 被引量:3
6
作者 Fang Zhou Lin Niu +2 位作者 Min Zhao Wei-Xing Ni Jian Liu 《World Journal of Clinical Cases》 SCIE 2020年第12期2542-2553,共12页
BACKGROUND The anthracycline chemotherapeutic drugs are cardiotoxic.Studies have found some indicators related to cardiotoxicity.However,there is currently no accurate indicator that can predict cardiac toxicity early... BACKGROUND The anthracycline chemotherapeutic drugs are cardiotoxic.Studies have found some indicators related to cardiotoxicity.However,there is currently no accurate indicator that can predict cardiac toxicity early.AIM To explore the diagnostic value of real-time three-dimensional echocardiography(RT3DE)in predicting cardiac toxicity in breast cancer patients undergoing chemotherapy.METHODS Female breast cancer patients who underwent radical mastectomy and postoperative chemotherapy at the Affiliated Hanzhou First People’s Hospital,Zhejiang University School of Medicine were recruited.All patients were routinely administered with chemotherapy for four cycles(T1-T4)after surgery.Two-dimensional(2D)echocardiography,RT3DE,and serological examinations were performed after each cycle of chemotherapy.Patients were divided into a toxic group and a non-toxic group based on whether patients hadΔleft ventricular ejection fraction>10%after one year of chemotherapy.Repeated measurement analysis of variance was used to compare the changes in 2D echocardiographic indicators,serological indicators,and RT3DE indicators before independent predictive indicators for cardiac toxicity in postoperative chemotherapy patients.Receiver operating characteristics(ROC)curve analysis was performed to analyze the diagnostic value of potential indicators in the diagnosis of cardiotoxicity.RESULTS A total of 107 female breast cancer patients were included in the study.T4 maximum peak velocity in early diastole(E peak)/mitral annulus lateral tissue Doppler(e'peak)(E/e'),serological indicators[T4 cardiac troponin I(cTnI)and T4 pro-brain natriuretic peptide(Pro-BNP)],T3 minimum left atrial volume(LAV),T4 LAVmin,T3 LAV before the start of the P wave(LAVprep),and T4 LAVprep in the toxicity group were significantly higher than those in the nontoxic group.Multivariate logistic regression found that T4 cTnI,T4 Pro-BNP,T3 LAVmin,T4 LAVmin,T3 LAVprep,and T4 LAVprep had potential predictive value for cardiac toxicity(P<0.05).ROC results showed that T4 LAVmin had the highest accuracy for diagnosing cardiac toxicity[area under the curve(AUC)=0.947;sensitivity=78.57%;specificity=94.62%],followed by T4 LAVprep(AUC=0.899;sensitivity=100%;specificity=66.67%).The accuracies of LAVprep and LAVprep in predicting cardiac toxicity were higher than those of T3 LAVmin and T3 LAVprep.CONCLUSION RT3DE of left atrial volume can be used to predict the cardiotoxicity caused by chemotherapy,and it is expected to guide the clinical adjustment of dose and schedule in time. 展开更多
关键词 Atrial volume CHEMOTHERAPY Breast cancer Cardiac toxicity real-time three-dimensional echocardiography ANTHRACYCLINES
下载PDF
QUANTITATIVE ASSESSMENT OF MYOCARDIAL PERFUSION DEFECTS WITH REAL-TIME THREE-DIMENSIONAL MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY 被引量:2
7
作者 Lei Zhuang Ming-xing Xie +2 位作者 Wei-juan Wang Xiang-xin Yang Tao Liu 《Chinese Medical Sciences Journal》 CAS CSCD 2006年第3期135-139,共5页
Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed... Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed in 21 open-chest mongrel dogs undergoing acute ligation of the left anterior descending artery (LAD, n=14) or distal branch of the left circumflex artery (LCX, n=7). A perfluorocarbon microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with Philips Sonos-7500 ultrasound system. Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. In vitro anatomic measurement of myocardial mass after removal of the animal’s heart was regarded as the control. Blinded off-line calculation of left ventricular mass and perfusion defect mass from RT3DE images were performed using an interactive aided-manual tracing technique.Results Total left ventricular (LV) myocardial mass ranged from 38.9 to 78.5 (mean±SD: 60.0±10.1) g. The mass of perfusion defect ranged from 0 to 21.4 (mean±SD: 12.0±5.0) g or 0 to 27% of total LV mass (mean±SD: 19%±6%). The RT3DE estimation of total LV mass (mean±SD: 59.8±9.9 g) strongly correlated with the anatomic measurement (r=0.98; y=2.01+0.96x). The CE-RT3DE calculation of the mass of underperfused myocardium (mean±SD: 12.3±5.3 g) also strongly correlated with the anatomic measurement (r=0.96; y=-0.10+1.04x) and when expressed as percentage of total LV mass (r=0.95; y=-0.20+1.04x). Conclusions RT3DE with myocardial contrast opacification could accurately estimate underperfused myocardial mass in dogs of acute coronary occlusion and would play an important role in quantitative assessment of myocardial perfusion defects in patients with coronary artery disease. 展开更多
关键词 real-time three-dimensional echocardiography CONTRAST perfusion defects myocardial infarction
下载PDF
Role of real-time three-dimensional transesophageal echocardiography in mitral valve repair 被引量:1
8
作者 Cuizhen Pan~1 Xianhong Shu~1 Qiling Cao~2 Chunsheng Wang~1 Wenjun Ding~1 Haozhu Chen~1 1 Department of Echocardiography, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China, 2 Rush University Medical Center, Chicago, USA 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2008年第3期137-141,共5页
Background and objective Pre-operative assessment of mitral valve (MV) anatomy is essential to surgical design in patients undergoing MV repair.Although 2-dimensional (2D) echocardiography provides precise information... Background and objective Pre-operative assessment of mitral valve (MV) anatomy is essential to surgical design in patients undergoing MV repair.Although 2-dimensional (2D) echocardiography provides precise information regarding MV anatomy,RT-3D TEE could increase the understanding of MV apparatus and individual scallop identification.We aimed to investigate the value of RT- 3DTEE in MV repair.Methods RT-3DTEE was performed in six patients with mitral valve prolapse (MVP) by using Philips 1E33 with X7-2t probe.Preoperative RT-3DTEE studies were compared with surgical findings in patients undergoing surgical mitral valve repair,and quantitative evaluation was performed by QLab 6.0 software before and after surgical mitral valve repair.Results RT- 3DTEE could display dynamic morphology of MV,the location of prolapse,and spatial relation to the surrounding tissue.It could provide surgical views of the valves and the valvular apparatus.These results were consistent with surgical findings.The quantitative evaluation before and after surgical MV repair indicated that anterolateral to posteromedial diameter of annulus,anterior to posterior diameter of annulus,perimeter of annulus,and area of annulus in projection plane were significantly smaller after operation compared with those before operation (P【0.05).The length of posterior leaflet,the area of anterior and posterior leaflet,the maximal prolapse height,the volume of leaflet prolapse and the length of coaptation in projection plane were significantly reduced after operation (P【0. 05).Conclusion RT-3DTEE is a unique new modality for rapid and accurate evaluation ofmitral valve prolapse and mitral valve repair. 展开更多
关键词 echocardiography real-time transeophageal MITRAL VALVE REPAIR
下载PDF
Real-time Three-dimensional Echocardiography in Assessment of Left Ventricular and Right Ventricular Volumes
9
作者 YingYang Xin-fangWang Ming-xingXie JingWang 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第3期236-236,共1页
关键词 ADULT echocardiography three-dimensional Heart Ventricles Humans Stroke Volume Ventricular Function Left Ventricular Function Right
下载PDF
Real-time Three-dimensional Echocardiography in Assessment of Congenital Double Orifice Mitral Valve
10
作者 吕清 卢晓芳 +7 位作者 谢明星 王新房 王静 杨亚利 袁莉 贺林 刘夏天 付曼丽 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第5期625-628,共4页
The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiograp... The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiography (2DE) and RT 3DE. The spatial morphology of malformed mitral valve and its change in hemodynamics were observed. DOMV associated with partial atrioventricular septal defect was found in 3 cases (in which 2 cases had cleft mitral valve) and isolated DOMV in 2 cases; and moderate to severe mitral regurgitation was detected in 3 cases, and mild mitral regurgitation in 1, and no regurgitation in 1 case; 1 case had complicated rhumatic heart disease. Three cases were preoperatively discovered by 2DE, while 2 missed (1 case was discovered postoperatively). Four cases were diagnosed by RT 3DE preoperatively, and 1 case was diagnosed postoperatively (not examined by RT 3DE preoperatively). It was suggested that RT 3DE is a reliable technique in the diagnosis of DOMV; it permitted comprehensive and noninvasive assessment of mitral valve and may supplement 2D TTE in the assessment of DOMV. 展开更多
关键词 double orifice mitral valve echocardiography real-time three-dimensional
下载PDF
Catheter ablation of atrial fibrillation facilitated by preprocedural three-dimensional transesophageal echocardiography: Long-term outcome 被引量:3
11
作者 Klaus Kettering Felix Gramley Stephan von Bardeleben 《World Journal of Cardiology》 CAS 2017年第6期539-546,共8页
AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echo... AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echocardiography(3D TEE) was performed immediately prior to an ablation procedure(paroxysmal AF: 30 patients, persistent AF: 20 patients). The images were available throughout the ablation procedure. Two different ablation strategies were used. In most of the patients with paroxysmal AF, the cryoablation technique was used(Arctic Front Balloon, Cryo Cath Technologies/Medtronic; group A2). In the other patients, a circumferential pulmonary vein ablation was performed using the CARTO system [Biosense Webster; group A1(paroxysmal AF), group B(persistent AF)]. Success rates and complication rates were analysed at 4-year follow-up.RESULTS A 3D TEE could be performed successfully in all patients prior to the ablation procedure and all four pulmonaryvein ostia could be evaluated in 84% of patients. The image quality was excellent in the majority of patients and several variations of the pulmonary vein anatomy could be visualized precisely(e.g., common pulmonary vein ostia, accessory pulmonary veins, varying diameter of the left atrial appendage and its distance to the left superior pulmonary vein). All ablation procedures could be performed as planned and almost all pulmonary veins could be isolated successfully. At 48-mo followup, 68.0% of all patients were free from an arrhythmia recurrence(group A1: 72.7%, group A2: 73.7%, group B: 60.0%). There were no major complications.CONCLUSION3 D TEE provides an excellent overview over the left atrial anatomy prior to AF ablation procedures and these procedures are associated with a favourable long-term outcome. 展开更多
关键词 Pulmonary veins Catheter ablation Atrial fibrillation Transesophageal echocardiography three-dimensional echocardiography
下载PDF
Incremental value of three-dimensional and contrast echocardiography in the evaluation of endocardial fibroelastosis and multiple cardiovascular thrombi: A case report 被引量:1
12
作者 Li-Juan Sun Ying Li +2 位作者 Wei Qiao Jia-Hui Yu Wei-Dong Ren 《World Journal of Clinical Cases》 SCIE 2021年第14期3365-3371,共7页
BACKGROUND Endocardial fibroelastosis(EFE)is a rare heart disease characterized by thickening of the endocardium caused by massive proliferation of collagenous and elastic tissue,usually leading to impaired cardiac fu... BACKGROUND Endocardial fibroelastosis(EFE)is a rare heart disease characterized by thickening of the endocardium caused by massive proliferation of collagenous and elastic tissue,usually leading to impaired cardiac function.Multimodality cardiovascular imaging for the evaluation of EFE with thrombi is even rarer.CASE SUMMARY We report a rare case of EFE associated with multiple cardiovascular thrombi.Three-dimensional(3D)and contrast echocardiography(CE)were used to assess ventricular thrombi.Anticoagulant therapy was administered to eliminate the thrombi.The peripheral contrast-enhanced thrombi with the highest risk were dissolved with anticoagulant therapy at the time of reexamination,which was consistent with the presumption of fresh loose thrombi.CONCLUSION This new echocardiography technique has a great advantage in the diagnosis and treatment of EFE.On the basis of conventional echocardiography,3D echocardiography is used to display the position,shape,and narrow base of the thrombus.CE does not only help to confirm the diagnosis of thrombus,but also determines its risk. 展开更多
关键词 Endocardial fibroelastosis three-dimensional echocardiography Contrast echocardiography THROMBOSIS Left ventricle Case report
下载PDF
Assessment of left ventricular systolic synchronicity by real-time three-dimensional echocardiography in patients with dilated cardiomyopathy 被引量:16
13
作者 ZENG Xin SHU Xian-hong +4 位作者 PAN Cui-zhen CHEN Rui-zhen CHENG Kuan LIU Shi-zhen CHEN Hao-zhu 《Chinese Medical Journal》 SCIE CAS CSCD 2006年第11期919-924,共6页
Background Recent advances in real-time three-dimensional echocardiography (RT3DE) offer the potential to assess the left ventricular (LV) dyssynchrony simultaneously by analyzing the 17 segments time-volume curve... Background Recent advances in real-time three-dimensional echocardiography (RT3DE) offer the potential to assess the left ventricular (LV) dyssynchrony simultaneously by analyzing the 17 segments time-volume curves. The purpose of this study was to test the feasibility and accuracy of RT3DE for quantitative evaluation of left ventricular systolic synchronicity. Methods Twenty-four patients with dilated cardiomyopathy (DCM) and twenty-ftve healthy volunteers were enrolled in this study. Full volume RT3DE was performed by using Philips IE33 with X3-1 probe. The global and 17-segmental time-volume curves were obtained by the on-line Qlab software (version 4.2). The time to minimal systolic volume in each segment (Tmsv) was taken to derive the following indexes of systolic asynchrony: Tmsv 16-SD, Tmsv 16-Dif, Tmsv 12-SD, Tmsv 12-Dif, Tmsv 6-SD and Tmsv 6-Dif, which meant the standard deviation or the maximal difference of Tmsv among the 16, 12 and 6 segments of the left ventricle respectively. The software also provided with each of the above parameters as a percentage of the cardiac cycle. Results Tmsv 16-SD, Tmsv 12-SD and Tmsv 6-SD were all significantly larger in the DCM group than those of the control group [Tmsv 16-SD: (52.9±40.6) ms vs (8.8±6.2) ms; Tmsv 12-SD: (29.5+30.8) ms vs (6.9±4.0) ms; Tmsv 6-SD: (28.9±34.6) ms vs (7.0±4.7)ms, all P≤0.001]. Tmsv 16-Dif, Tmsv 12-Dif and Tmsv 6-Dif were also significantly larger in the DCM group. There were close negative relations between the LVEF determined by RT3DE and each of the indexes of systolic asynchrony, among which the indexes of Tmsv-16-SD% and Tmsv-16-Dif% correlated most closely (r=-0.703 and r=-0.701, respectively). The DCM patients had significantly larger EDV and ESV, with significantly reduced LVEF compared with the healthy subjects. Conclusion RT3DE provides a simple, useful and unique approach to assess the systolic synchronicity of all the left ventricular segments simultaneously. 展开更多
关键词 echocardiography real-time three-dimensional left ventricular function myocardial contraction cardiac resynchronization therapy
原文传递
Validation of real-time three-dimensional echocardiography for quantifying left and right ventricular volumes:an experimental study 被引量:38
14
作者 费洪文 王新房 +5 位作者 谢明星 庄磊 陈立新 杨颖 黄润青 王静 《Chinese Medical Journal》 SCIE CAS CSCD 2004年第5期695-699,共5页
Background Assessment of the left ventricular (LV) and the right ventricular (RV) volumes and their functions is important for prognostic prediction and clinical decision making. We compared the accuracy for quantify... Background Assessment of the left ventricular (LV) and the right ventricular (RV) volumes and their functions is important for prognostic prediction and clinical decision making. We compared the accuracy for quantifying the LV and the RV volumes in vitro between conventional two-dimensional echocardiography (2DE) and real-time three-dimensional echocardiography (RT3DE) Methods The volumes of 37 rubber-models (10 regularly shaped to simulate normal LV, 7 shaped to simulate LV with symmetric aneurysm, 8 shaped to simulate LV with asymmetric aneurysm, and 12 irregularly shaped to simulate normal RV) and 10 excised canine hearts were measured by RT3DE and 2DE On RT3DE 'full volume' imaging, the inner-surfaces of the rubber-models and canine LV and RV were outlined and the volumes were measured using 2-, 4-, 8- and 16-plane methods with the RT3DE analysis software On 2DE imaging, the volumes were measured by the Simpson method The LV and RV volumes measured by drained water were served as reference values, with which we compared RT3DE and 2DE data Results In rubber models mimicking normal LV and LV with symmetric aneurysms, RT3DE results were strongly correlated with reference values ( r =0 795-0 998) and there was a good correlation between 2DE estimates and reference values ( r =0 715-0 729) There were no significant differences between RT3DE estimates, 2DE results and reference values ( P >0 05) In rubber models mimicking the RV and LV with asymmetric aneurysm, RT3DE strongly correlated with reference values ( r =0 765-0 988), but 2DE weakly correlated with reference values ( r =0 518-0 592) There were no differences between RT3DE and reference values ( P >0 05), but a significant difference between 2DE and reference values occurred ( P <0 05) For excised canine hearts, there was a strong correlation between RT3DE and reference values ( r =0 728-0 914), while 2DE showed a less obvious correlation ( r =0 502-0 615) Again, there were no significant differences between RT3DE and reference values ( P >0 05), but there was a significant difference between 2DE and reference values ( P <0 05) Conclusions RT3DE can accurately quantify LV and RV volumes and provides a new tool to evaluate LV and RV function For LV and RV measurements by RT3DE, 8-plane strategy is the optimum choice for accuracy and convenience 展开更多
关键词 real-time three-dimensional echocardiography · two-dimensional echocardiography · left ventricular volume · right ventricular volume
原文传递
Value of left ventricular regional ejection fraction determined by real-time three-dimensional echocardiography in diagnosis of aneurysm: compared with left ventriculography 被引量:13
15
作者 LI Xiu-chang YAN Cheng-jun +3 位作者 YAO Gui-hua ZHANG Mei LI Ji-fu ZHANG Yun 《Chinese Medical Journal》 SCIE CAS CSCD 2009年第24期2981-2984,共4页
Background Regional ejection fraction (EFR) measured by real-time three-dimensional echocardiography (RT-3DE) provides a novel method for quantifying left-ventricular (LV) regional systolic function. We aimed to... Background Regional ejection fraction (EFR) measured by real-time three-dimensional echocardiography (RT-3DE) provides a novel method for quantifying left-ventricular (LV) regional systolic function. We aimed to explore the diagnostic value of regional ejection fraction (EFR) derived from RT-3DE in detecting LV aneurysms in patients with myocardial infarction. Methods Thirty-eight patients with myocardial infarction were prospectively enrolled and underwent electrocardiography (ECG), two-dimensional echocardiography (2-DE), RT-3DE and left ventriculography (LVG). Subjects with a negative EFR in at least one segment on RT-3DE were considered as having a ventricular aneurysm. We compared the sensitivity, specificity, Youden's index, and positive and negative predictive values of ECG, 2-DE and RT-3DE in determining LV aneurysm with detection by LVG. Results On LVG an LV aneurysm was diagnosed in 16 (42.1%) patients. The sensitivity and specificity were 62.5% and 86.4% for ECG, 81.2% and 95.4% for 2-DE, and 100.0% and 90.9% for RT-3DE in diagnosing LV aneurysm. Youden's indexes for ECG, 2-DE and RT-3DE were 0.49, 0.77 and 0.91, respectively. Positive and negative predictive values were 76.9% and 76.0% for ECG, 92.9% and 87.5% for 2-DE, and 88.9% and 100.0% for RT-3DE. Conclusions RT-3DE-derived EFR provides a novel, reliable index in the diagnosis of LV aneurysm and has excellent sensitivity and specificity. 展开更多
关键词 three-dimensional echocardiography ANEURYSM left ventricle regional ejection fraction
原文传递
Left atrial minimum volume by real-time three-dimensional echocardiography as an indicator of diastolic dysfunction 被引量:6
16
作者 LIN Qiong-wen WANG Wu-gang WU Wei-chun WANG Hao 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第22期4227-4231,共5页
Background Left atrial (LA) maximum volume is becoming a prognostic biomarker for left ventricular (LV) diastolic dysfunction. However, we assessed LV diastolic function by measuring LA phasic volumes using real-t... Background Left atrial (LA) maximum volume is becoming a prognostic biomarker for left ventricular (LV) diastolic dysfunction. However, we assessed LV diastolic function by measuring LA phasic volumes using real-time threedimensional echocardiography (RT3DE) in patients with stable coronary artery disease (CAD). Methods Sixty-five stable CAD patients with normal LV ejection fraction (LVEF) were divided into three groups according to degree of coronary stenosis: control (n=15) with 〈50% stenosis as control group, mildS (n=25) with mild stenosis (50%- 70%) and severeS (n=25) with 〉70% stenosis. LA phasic volumes and function were evaluated and compared using RT3DE and two dimensional echocardiography (2DE). N-terminal pro-B-type natriuretic peptide (NT-proBNP) levels were examined. The correlations of RT3DE-derived parameters with other conventional indices were analyzed. Results Significant correlations between RT3DE and 2DE for LA volume measurements were: control, r=0.93; mildS, 1=0.94; severeS, r=0.90 (all P 〈0.05). Patients with severe coronary stenosis presented higher NT-proBNP level, indices of LA minimum volume and volume before atrial contraction, but lower LA total emptying fraction (LAEF) and LAEFpass^ve. Significant correlations of RT3DE derived LA volume indices with E/E' (r=0.695) and NF-proBNP (r=0.630) level were found. Conclusions RT3DE derived, LA indices correlate well with NT-proBNP level and may be superior to 2DE measurements for the evaluation of LV diastolic dysfunction. Enlargement of LA minimum volume in stable CAD patients without systolic dysfunction appears earlier and may be better correlated with LV diastolic function than that of LA maximum volume. 展开更多
关键词 real-time three-dimensional echocardiography left atrial volume diastolic dysfunction coronary arterydisease N terminal pro B type natriuretic peptide
原文传递
Evaluation of Left Ventricular Function by Three-Dimensional Speckle-Tracking Echocardiography in Patients with Chronic Kidney Failure 被引量:4
17
作者 Yu-bo WANG Hui HUANG +4 位作者 Shan LIN Mei-jia HAO Lu-jiao HE Kun LIU Xiao-jun BI 《Current Medical Science》 SCIE CAS 2022年第4期895-901,共7页
Objective:To establish a quantitative evaluation of the left ventricle's systolic function in patients with chronic kidney failure(CKF)by three-dimensional speckle-tracking echocardiography.Methods:Two-dimensional... Objective:To establish a quantitative evaluation of the left ventricle's systolic function in patients with chronic kidney failure(CKF)by three-dimensional speckle-tracking echocardiography.Methods:Two-dimensional and three-dimensional transthoracic echocardiography was performed on 30 patients with CKF.The ejection fraction,mass and global peak longitudinal strain,global circumferential strain,global area strain,and global radial strain of the left ventricle were calculated.Results:The ejection fraction,mass and global peak longitudinal strain(GLS),global circumferential strain(GCS),global area strain(GAS),and global radial strain(GRS)in the CKF group were significantly lower than those in the control group.Simultaneously,the GLS,GCS,GAS and GRS were well correlated with the ejection fraction.For patients with normal ejection fraction in the CKF group,the GLS,GCS,GAS and GRS were lower than those in the control group,while the left ventricular mass was significantly higher in CKF patients than in the control group.For patients with hypertension in the CKF group,ejection fraction,GLS,GCS,GAS and GRS calculated using three-dimensional echocardiography were significantly lower than those in patients with normal blood pressure;however,the myocardial mass was higher.Conclusions:The parameters(GLS,GCS,GAS and GRS)calculated using three-dimensional speckle-tracking software were lower in the CKF group.Simultaneously,the left ventricular mass was higher in CFK patients than in the control group,thus showing that the myocardial contraction function was impaired and that myocardial remodeling had occurred. 展开更多
关键词 three-dimensional speckle-tracking echocardiography left ventricle ejection fraction STRAIN chronic kidney failure
下载PDF
Clinical Value of Stereoscopic Three-dimensional Echocardiography in Assessment of Atrial Septal Defects: Feasibility and Efficiency 被引量:1
18
作者 王静 王新房 +3 位作者 谢明星 贺林 吕清 王蕾 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第6期791-794,共4页
Stereoscopic three-dimensional echocardiography(S-3DE) is a novel displaying technol-ogy based on real-time 3-dimensional echocardiography (RT-3DE). Our study was to evaluate the feasibility and efficiency of S-3D... Stereoscopic three-dimensional echocardiography(S-3DE) is a novel displaying technol-ogy based on real-time 3-dimensional echocardiography (RT-3DE). Our study was to evaluate the feasibility and efficiency of S-3DE in the diagnosis of atrial septal defect (ASD) and its use in the guidance for transcatheter ASD occlusion. Twelve patients with secundum ASD underwent RT-3DE examination and 9 of the 12 were subjected to transcatheter closure of ASD. Stereoscopic vision was generated with a high-performance volume renderer with red-green stereoscopic glasses. S-3DE was compared with standard RT-3D display for the assessment of the shape, size, and the surrounding tis-sues of ASD and for the guidance of ASD occlusion. The appearance rate of coronary sinus and the mean formation time of the IVC, SVC were compared. Our results showed that S-3DE could measure the diameter of ASD accurately and there was no significant difference in the measurements between S-3DE and standard 3D display (2.89±0.73 cm vs 2.85±0.72 cm, P〉0.05; r=0.96, P〈0.05). The appearance of coronary sinus for S-3DE was higher as compared with the standard 3D display (93.3% vs 100%). The mean time of the IVC, SVC for S-3DE monitor was slightly shorter than that of the standard 3D display (11.0±3.8 s vs 10.3±3.6 s, P〉0.05). The mean completion time of interven-tional procedure was shortened with S-3DE display as compared with standard 3D display (17.3±3.1 min vs 23.0±3.9 min, P〈0.05). Stereoscopic three-dimensional echocardiography could improve the visualization of three-dimensional echocardiography, facilitate the identification of the adjacent structures, decrease the time required for interventional manipulation. It may be a feasible, safe, and efficient tool for guiding transcatheter septal occlusion or the surgical interventions. 展开更多
关键词 echocardiography stereoscopic vision real time three-dimension atrial septal defect OCCLUSION
下载PDF
Evaluation of the Left Ventricular Remodeling in Patients with Myocardial Infarction after Revascularization with Intravenous Real-time Myocardial Contrast Echocardiography 被引量:1
19
作者 毕小军 邓又斌 +4 位作者 申屠伟慧 熊莉 张芸 余芬 黄润青 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2008年第3期287-290,共4页
In order to evaluate the left ventricular remodeling in patients with myocardial infarction after revascularization with intravenous real-time myocardial contrast echocardiography (RT-MCE), intravenous RT-MCE was pe... In order to evaluate the left ventricular remodeling in patients with myocardial infarction after revascularization with intravenous real-time myocardial contrast echocardiography (RT-MCE), intravenous RT-MCE was performed on 20 patients with myocardial infarction before coronary revascularization. Follow-up echocardiography was performed 3 months after coronary revascularization. Segmental wall motion was assessed using 18-segment LV model and classified as normal, hypokinesis, akinesis and dyskinesis. Myocardial perfusion was assessed by visual interpretation and divided into 3 conditions: homogeneous opacification=l; partial or reduced opaciflcation or subendocardial contrast defect=2; constrast defect=3. Myocardial perfusion score index (MPSI) was calculated by dividing the total sum of contrast score by the total number of segments with abnormal wall motion. Twenty patients were classified into 2 groups according to the MPSI: MPSI≤I.5 as good myocardial perfusion, MPSI〉1.5 as poor myocardial perfusion. To assess the left ventricular remodeling, the following comparisons were carried out: (1) Comparisons of left ventricular ejection fraction (LVEF), left ventricular end-systolic volume (LVESV) and left ventricular end-diastolic volume (LVEDV) before and 3 months after revascularization in two groups;(2) Comparisons of LVEF, LVESV and LVEDV pre-revascularization between two groups and comparisons of these 3 months post-revascularization between two groups; (3) Comparisons of the differences in LVEF, LVESV and LVEDV between 3 months post-and pre-revascularization (ALVEF, ALVESV and ALVEDV) between two groups; (4) The linear regression analysis between ALVEF, ALVESV, ALVEDV and MPSI. The results showed that the LVEF obtained 3 months after revascularization in patients with MPSI〉1.5 was obviously lower than that in those with MPSI〈1.5. The LVEDV obtained 3 months post-revascularization in patients with MPSI〉1.5 was obviously larger than that in those with MPSI≤1.5 (P=0.002 and 0.04). The differences in ALVEF and ALVEDV between patients with MPSI〉I.5 and those with MPSI≤1.5 were significant (P=0.002 and 0.001, respectively). Linear regression analysis revealed that MPSI had a negative correlation with ALVEF and a positive correlation with ALVESV, ALVEDV (P=0.004, 0.008, and 0.016, respectively). It was concluded that RT-MCE could accurately evaluate the left ventricular remodeling in patients with myocardial infarction after revascularization. 展开更多
关键词 real-time myocardial contrast echocardiography myocardial infarction left ventricularremodeling REVASCULARIZATION
下载PDF
Left Ventricular Systolic Strain of the Cardiac Allograft Evaluated with Three-dimensional Speckle Tracking Echocardiography 被引量:1
20
作者 刘红云 邓又斌 +5 位作者 刘琨 李阳 汤乔颖 魏翔 昌盛 卢峡 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2013年第5期765-769,共5页
Three-dimensional speckle tracking echocardiography was employed to evaluate the changes of left ventricular systolic strain in 23 heart transplant recipients at 1 st, 3rd, 6th and 12th month after heart transplantati... Three-dimensional speckle tracking echocardiography was employed to evaluate the changes of left ventricular systolic strain in 23 heart transplant recipients at 1 st, 3rd, 6th and 12th month after heart transplantation, and 23 healthy subjects served as controls. The three-dimensional full-volume echocardiographic images of left ventricle were recorded and then were analyzed using EchoPAC software. The strain curves and peak systolic strain values for each segment and overall left ventricular wall were obtained. Left ventricular global peak longitudinal strain (GPSL), global peak radial strain (GPSR), global peak circumferential strain (GPSC) and global peak area strain (GPSA) were measured and then statistically analyzed. There were no significant differences in left ventricular ejection fraction (LVEF) and cardiac output (CO) between heart transplant recipients and controls. The GPSL in heart transplant recipients at 1st month after surgery was significantly lower than that in controls, but close to the normal value at 3rd month after surgery and later. The GPSC, GPSA and GPSR were significantly lower in heart transplant recipients at 1 st, 3rd, 6th and 12th month after surgery than those in controls. It is suggested that three-dimensional speckle tracking echocardiography can be used for monitoring changes of left ventricular systolic strains and evaluating left ventricular systolic function in cardiac allograft. 展开更多
关键词 three-dimensional echocardiography speckle tracking imaging heart transplantation